Ye battery jo ags ki hn inme normal cell yani flat cell use hue hn na ke tubular cell tbhi inki setting ko normal lead acid battery ki trhan rakhen na ke tubular wali phir sahi chalegi
Yes Mera bhi nitrox 6KW system tha, 4 normal lead acid batteries thi Osaka ki 180AH wali, But by default nitrox ki battery charging voltage settings were at much higher voltages ( float, equalization and absorption ) So I changed the voltages values recommended for normal lead acid batteries i.e 54V for Float voltage, 56V for equalization & 57V for absorption. Alhamdulillah batteries are running perfect now without heat up or boiling. I am myself an engineer so I changed the values myself
I have ags 75ah batter which i use directly to run ac dc fan. I want to know what should be the cutoff voltage of battery to protect it from deep discharge. Or what is the dod of my battery? I didn't find any information regarding this on batter box and leaflet.
Or ek bt ap log price kem hone ki wja se ye battery na len ye tubular battery jitni life nh deti h mne shuru me kafi jga lgai h ye battery jisko me pichle 6 month phle. Tk bukatta rha hoon
Equalization ki wajah sey boil ho raha ho shayad. After set number of days inverter charges batteries higher to equalize them. Series mein lagi hoyi hain because so sab ko overcharge/boil kara kay voltage balance karta hai. Warna aik battery constantly low rahay gi tou overall battery bank ki backup capacity low miley gi.
Salam sir bhai Jan 3kw nitrox system ha phonenix tx1800 4 battery lagai ha kia settings karay zayada ter wapda sa he charged kartay ha hum ku k sat on grid b system laga howa ha
Salam, ur videos r informative. Keep it up. Ags tubular batteries ka experience kaisa raha, iam using phoenix from last 4 years no complain, ab ags tubular se change karna cha raha hoon. Tell us about ur experience abt ags
🔰 30Amp Maximum Charging From Solar and Wapda لیکن اگر آپ ایک ہی وقت میں واپڈا اور سولر دونوں سے چارج کروا رہے ہیں SNU رکھ کر تو پھر 20 + 20 ایمپئر سیٹ کریں۔ اگر CSO کی سیٹنگ ہے تب ویڈیو میں بتائی گئی سیٹنگ رکھیں۔
@@AGradeSolarKarachi Cso par hai Max Charging 30a per hai or wapda charging 20a hai bulk charging 29.2v hai or float charging 27v hai low battery cut off 21v hai SBU per 12 no setting 22.5 or 13 no full hai kaya yeh ok hai.
Mere pass fronus pv 2200 inverter hai us k sath mene ags sp tall 2500 battery connect kri hai backup bht km de rhi hai mene charge bhi krwa li lekin wohi masla hai gravity bhi ok hai charging bhi ok hai but 100 watt ka load dal rha hu phr bhi just 1 ghnty ka backup de rhi hai battery
میںنے اپنی بیٹری یو پی ایسپر لگای ھوی ھے ایک سال چار ماہ کے بعد گرم ھو رہی ھے یو پی ایس چککرایا بیٹری چک کرای دونوں ٹیک ھیں اخری پوانٹ ورق کرتارہتاھے ٹریپ نہیں ھوتا کیاحل ھے شکریہ
I am from Sialkot 230ah ki phoenix ki do batteries hain. Facing no issue . For safety purposes please suggest me battery setting even complete 3kw nitrox setting. Thanks
For Tubular Battery Maximum Charging Voltage 14.2 Flot 14.3 Equlization.14.4 In Ideal Conditions on.New Battery After 1 year Maximum 14 Flot 14 Equlization 14.2 per battery
Bhai mere pas Inverex 3.2 Kw 2 saal phlay lia tha us mai bi settings hoti hai es trah agar hai to kindly suggest me mere battery 3 saal Baad fail ho gye hai
Sir Layman Nehin Jan Sekta it is dufficult to explain - as per weather condition u can get 75-80% of output againt 100% of solar input in ideal weather condition u may get 90% also- on the other hand stock lot and non documented panels will give you 50% - 60% generation and it will further decline day after day.
Battery Manuals kay mutabiq 25 Amp ki charging ka kaha hota ha ...ap 60Amp rakh dety hain...acha hova kay waqat par aqal aa gae ...ismay AGS walo ka masla nahi, masla installers ka ha,,,,settings ka pta nahi hota aur bs lagy hotey hain system install karne...
Ye battery jo ags ki hn inme normal cell yani flat cell use hue hn na ke tubular cell tbhi inki setting ko normal lead acid battery ki trhan rakhen na ke tubular wali phir sahi chalegi
Sir kmal ki videos hoti han app ki
Mianwali say slam
Sir he battery ups me sirf 2 panky solar k sirf 2 ganty chalati ziyada time nai deti he b new
Aapny btaya nai k ye settings kamiyab rahi ya nai?
Yes Mera bhi nitrox 6KW system tha, 4 normal lead acid batteries thi Osaka ki 180AH wali,
But by default nitrox ki battery charging voltage settings were at much higher voltages ( float, equalization and absorption )
So I changed the voltages values recommended for normal lead acid batteries i.e 54V for Float voltage, 56V for equalization & 57V for absorption. Alhamdulillah batteries are running perfect now without heat up or boiling.
I am myself an engineer so I changed the values myself
What is idle self consumption of nitrox 6kw?
I have ags 75ah batter which i use directly to run ac dc fan. I want to know what should be the cutoff voltage of battery to protect it from deep discharge. Or what is the dod of my battery? I didn't find any information regarding this on batter box and leaflet.
Bhai ags tall 1800 k leye kya floot voltage hone chaye
Or ek bt ap log price kem hone ki wja se ye battery na len ye tubular battery jitni life nh deti h mne shuru me kafi jga lgai h ye battery jisko me pichle 6 month phle. Tk bukatta rha hoon
Assalam o alaikum bhai Mere pas 185 k 4 panels hn or battery he tabular 90 ampere ki AGS .. us ki setting bata den bhai
Very good information thank you so much 👍👌❤️
Equalization ki wajah sey boil ho raha ho shayad. After set number of days inverter charges batteries higher to equalize them. Series mein lagi hoyi hain because so sab ko overcharge/boil kara kay voltage balance karta hai. Warna aik battery constantly low rahay gi tou overall battery bank ki backup capacity low miley gi.
Equalization se battery boil nehin hoti - and equalization time is for 60Min only after 120 days
@@AGradeSolarKarachi Okay
Ager kisi ko yaqeen na aye to wo ek bar check krle
Salam sir bhai Jan 3kw nitrox system ha phonenix tx1800 4 battery lagai ha kia settings karay zayada ter wapda sa he charged kartay ha hum ku k sat on grid b system laga howa ha
🔰 Charging 50Amp + Volt Yehi Rehain Ge Maximum 28 - Flot 28.5 Eulization 29.2
Salam, ur videos r informative.
Keep it up.
Ags tubular batteries ka experience kaisa raha, iam using phoenix from last 4 years no complain, ab ags tubular se change karna cha raha hoon. Tell us about ur experience abt ags
Phoenix best hy
I need help I'm using PV 2200 without solar panels just wapda I have AGS 2500 please what's best settings
10 amp 11 number setting rakho aur 26 number 14.6 and 27 number 14.3 krdo battry fit rahay gi
Main ne bi apni phoenix ki max a charge 46A se 30A kr dya hai. Acha kia?
Jee aacha hai batteries Normal.Speed Mein.Charge hun gi to inki Life Achi Rehe ghi
Sir is battery ky fully charged volts kitny hn kindly reply krdyn
Maximum Charge Volts 13.8 Rekh Sekte Hain Ayp
Sir crown 8.2 kw ka sitting btao please
Sir Osaka TA-1800 ki maximum charging or utility charging kitni rakhtay hain.
🔰 30Amp Maximum Charging From Solar and Wapda
لیکن اگر آپ ایک ہی وقت میں واپڈا اور سولر دونوں سے چارج کروا رہے ہیں SNU رکھ کر تو پھر 20 + 20 ایمپئر سیٹ کریں۔ اگر CSO کی سیٹنگ ہے تب ویڈیو میں بتائی گئی سیٹنگ رکھیں۔
@@AGradeSolarKarachi Cso par hai Max Charging 30a per hai or wapda charging 20a hai bulk charging 29.2v hai or float charging 27v hai low battery cut off 21v hai SBU per 12 no setting 22.5 or 13 no full hai kaya yeh ok hai.
Mere pass fronus pv 2200 inverter hai us k sath mene ags sp tall 2500 battery connect kri hai backup bht km de rhi hai mene charge bhi krwa li lekin wohi masla hai gravity bhi ok hai charging bhi ok hai but 100 watt ka load dal rha hu phr bhi just 1 ghnty ka backup de rhi hai battery
Sir: Agar 48v lithium battery hay to Float aur Bulk kitna hona chahiye Fronus 6KW interver mai?
Battery Per Mentioned Hote Hain Normally Narada Wegra 54 Volt Charge 43 Cutoff
Nice, but dost iski best charging ampere 22 hone chahiye
Assalam o alykum sir mery pass inverex vyron 2 h jo bger battery per bhi chalta h kiya ap mujhye setiing btaskty h ags 2000 tall tublar k liye
Bhai ags tubular nai bnata tall hai sirf wo tubular samjh ker mat lena
میںنے اپنی بیٹری یو پی ایسپر لگای ھوی ھے ایک سال چار ماہ کے بعد گرم ھو رہی ھے یو پی ایس چککرایا بیٹری چک کرای دونوں ٹیک ھیں اخری پوانٹ ورق کرتارہتاھے ٹریپ نہیں ھوتا کیاحل ھے شکریہ
I am from Sialkot 230ah ki phoenix ki do batteries hain. Facing no issue . For safety purposes please suggest me battery setting even complete 3kw nitrox setting. Thanks
For Tubular Battery
Maximum Charging Voltage 14.2
Flot 14.3
Equlization.14.4
In Ideal Conditions on.New Battery
After 1 year
Maximum 14
Flot 14
Equlization
14.2 per battery
@@AGradeSolarKarachi thank you so much
Bhai mere pas Inverex 3.2 Kw 2 saal phlay lia tha us mai bi settings hoti hai es trah agar hai to kindly suggest me mere battery 3 saal Baad fail ho gye hai
@@jawad88230 3Y - Battery Life is Over
@@AGradeSolarKarachi Je Bhai
Ya Setting All Inverter k Lia Hain?
Tubular Battery Easi Complain Abhi Tak Nehin Aai - Koi Heraj Nehin Hai Yeh Setting Ayp Tubular Per Rekh Sekte Hain
بیٹری سیٹنگ میں کتنے ah پر سیٹ کرنے چاہیے اگر آپکے پاس 2 بیٹریاں 210 ah کی ہیں اور آپکا انورٹر 24 وولٹ کا ہے
For Ags Batteries 14 Volt and 30Amp
Aey mery piyare Allah mery piyare Wattan ko Imrando munafaq ke shar sy, pinkie pirini ke kaly jadoo sy becha lo
bro ye issue inverter ka bhi ho skta ha shayad k inverter zyada ampere se battery charging kr rha ho
This issue has come over multiple sites even with 30Amp.Charging - Main.Reason is that batteries was not in use in Winters
30 amp bhi zyada hain bro
sir 48v me b btayen ditails sy?
Double the voltage values .
Aik layman kese jaan sakta hai ke all Solar pannel working condition mein hain aur kitni output each panel de raha hai ?
Sir Layman Nehin Jan Sekta it is dufficult to explain - as per weather condition u can get 75-80% of output againt 100% of solar input in ideal weather condition u may get 90% also- on the other hand stock lot and non documented panels will give you 50% - 60% generation and it will further decline day after day.
To is main kasur kis ka hai ???
🔰 ابھی تو کمپلین کا حل نکالنے اور عوام کو خبردار کرنے کی کوشیش کر رہے ہیں قصور پھر کبھی نکالیں گے۔
Ags ka
Jasy ap tu bary allama han apko tu sb kuch pta ha chahy jo b apki field ha. Aik bnda logo ki help kr raha ha ap tanz kr rahy han. 😡
@@uniquesolar 🖕
bajwa ka
AoA. Bhai ags tall battery ko local ups charge kar sakta hay 1200 watt Wala 12 volt wala
Dead Drain Hone Per Issues Hote Hain Ager Normal Use Hai Aur LoadShetting Zeda Nehin Hai to Kam Chal Sekta Hai
Sir maximum charges 30 amp.
Float aur Bulk charges kitne rakhen AGS Tall battery mein wo bhi bata dijiye.
Kitne KW System Hai ???
@@AGradeSolarKarachi 6kw.
Nice and informative video
Instead of Acid water only use 0 TDS distilled water
Yes U Can
بھائی میرے پاد ہومیج کا یو پی ایس ہیے 1200 بیٹری ags 1200 ہے لیکن مجھے ایک گنٹھے سے زیادہ بیک اپ نہیں ملتا لوڈ 360 واٹ ہوتا ہیں
ماشاءاللہ
السلام علیکم ۔ براہ کرم آئندہ کی ویڈیوز میں کوئ ایک زبان منتخب کر لیں اگر انگریزی زیادہ اچھی لگتی ہے تو ساری ویڈیو ہی انگریزی میں بنا دیں۔
زبردست
Sp tall 1800 ki setting
Sir my agr 1800 battery boiling
Bahi ٹھنڈا Pani Daal Ker Normal Kerian aur Charging Voltage Low Kerian
Battery Manuals kay mutabiq 25 Amp ki charging ka kaha hota ha ...ap 60Amp rakh dety hain...acha hova kay waqat par aqal aa gae ...ismay AGS walo ka masla nahi, masla installers ka ha,,,,settings ka pta nahi hota aur bs lagy hotey hain system install karne...
Aoa bhai
Awesome 👍👍👍👍👍
AGS Ki Tubbler Battery Bakwase hin Bohit Zayada Shakayat Hy in min .Min my 2 Jagah System k sath Lage thi Nakam hohi hin In Ki Gravty hi Down Hoti hy
Nice
بیٹری اے جی ایس دوہزار ھے
AGS Tubular Battery nahi hai
No - its Tall Battery with Thick Plates
Assalam u alaikum sir please apna watsap numbr share kryn 1 problem hy please