PV Solar installation I-V Curve tracer of photovoltaic strings and modules

Поделиться
HTML-код
  • Опубликовано: 13 сен 2024
  • New IV500w up to 1500V
    www.ht-instrume...
    I-V 400 is the ideal solution for the ordinary and scheduled maintenance of photovoltaic systems. With I-V 400, searching for possible failures and problems in systems is extremely rapid, efficient and intuitive. I-V 400 carries out the field measurement of the I-V characteristic and of the main characteristic parameters both of a single module and of module strings. The instrument measures, together with the I-V characteristic of the device being tested, also the values of its temperature and incident irradiation.
    The acquired data are then processed to extrapolate the I-V characteristic at standard test conditions (STC) in order to proceed with the comparison with the nominal data declared by the modules' manufacturer, thus immediately determining whether or not the string or the module being tested respects the characteristics declared by the manufacturer. Output current or voltage from the module or string is measured with the 4-terminal method, which allows extending the measurement cables without requiring any compensation for their resistance, thus always providing accurate and precise measures.
    In its internal memory, I-V 400 manages a database of photovoltaic modules, which can be updated at any time both via the management software and directly on the instrument. Together with the measurement of the I-V characteristic and the extrapolation of the characteristic at standard test conditions, I-V 400 compares the obtained values with the values declared by the manufacturer, immediately providing the OK / NO result of the test. The operator must not do any calculation, nor any difficult operation. The instrument carries out the comparison rapidly and automatically
    www.ht-instrume...
    Function
    •Measurement of output voltage from module/string up to 1000V DC
    •Measurement of output current from module/string up to 15A DC
    •Measurement of solar irradiation [W/m2] with reference cell
    •Measurement of temperature, automatic or by means of probe PT1000
    •Measurement of output DC and nominal power from module/string
    •Numerical and graphical display of I-V characteristic
    •Measurement of the resistance of photovoltaic module series
    •Mechanical inclinometer for incidence angle of solar irradiation
    •4-terminal measuring method
    •Comparison with standard conditions (STC 1000 W/m2, 25C)
    •Evaluation of testing result: OK / NO
    •Management of up to 30 types of modules in the internal database
    •Internal memory for data saving
    •Recalling results on the display
    •Optical/USB port for PC connection
    •Help on line on the display
  • НаукаНаука

Комментарии • 18

  • @1967gal
    @1967gal 14 лет назад

    Like it. just installed a 10 kilowatt array in Huntsville Ontario. Canada.
    Well shot and easy to understand.
    Good job on the video!

  • @Mr965274
    @Mr965274 12 лет назад

    Very easy to use, I tested hundreds of panels a day :)

  • @SimonLimon113
    @SimonLimon113 5 месяцев назад

    is there a new updated version of this unit?

  • @jim-elainestack5151
    @jim-elainestack5151 10 лет назад +2

    I'd be VERY CAREFUL connecting to the entire string, It has a high voltage and high current and can give you a bad burn. DC can really arc and make a nasty burn on you and the connectors!

  • @nadzmihakim841
    @nadzmihakim841 5 лет назад

    The DP max, as long as it is +, all panels are okay right? How about if the reading shows 0.95 ? Still normal?

  • @muhammadjafni5639
    @muhammadjafni5639 5 лет назад

    I want ask you something,why I test the HT,the erro is a unstable currently

  • @hafizsalmanishrat7940
    @hafizsalmanishrat7940 5 лет назад

    Please help me I test almost 100 module but in all test I am getting negative dp, Is any more setting I need to make

  • @erdoganyalcn9485
    @erdoganyalcn9485 4 года назад

    How do I reset the device to factory settings?

  • @CHANDANKUMAR-on8se
    @CHANDANKUMAR-on8se 5 лет назад

    Plz tell me about testing kit

  • @TomTubeUK
    @TomTubeUK 2 года назад +1

    Why is this guy ramming MC4 connectors into MC3 connectors? Lol 😂

  • @mahmoudgaber5347
    @mahmoudgaber5347 4 года назад

    what negative value is he talking about?.....DPmax?

  • @Mr965274
    @Mr965274 12 лет назад

    40MW Amherstburg ON

  • @romanali6559
    @romanali6559 8 месяцев назад

    Im work

  • @cordeliablakeslee7964
    @cordeliablakeslee7964 6 лет назад

    I made it with Avasva solutions.

  • @modestalacefield5770
    @modestalacefield5770 8 лет назад

    do it yourself , go to inplix page and learn how