COD Analysis Procedure, cod testing procedures.

Поделиться
HTML-код
  • Опубликовано: 25 ноя 2024

Комментарии • 50

  • @saritasharma6884
    @saritasharma6884 2 года назад +3

    Understand completely, thanks for sharing

  • @tarunsharma-xd4jh
    @tarunsharma-xd4jh 2 года назад +1

    Satisfied with the Information

  • @mustaquealam2388
    @mustaquealam2388 2 года назад +1

    Good knowledge .
    Deeply explain

  • @fayazahmadmir9026
    @fayazahmadmir9026 Год назад +4

    Please tell you have mentioned that burette reading of blank as 11.1 and burette reading of sample 10.5.The fact is that higher burette reading means higher COD.
    When Burette reading of blank is high it means its COD is high,which in turn means blank sample has higher organic content and incubated sample has low burette reading and low COD

    • @arvindthakur8840
      @arvindthakur8840 Год назад +3

      This is for your clearance: - please note that this is kind of back titration method. suppose you have some organic matter in the sample which shall be completely digested by some amount of K2Cr2O7, and surplus Potassium Dichromate shall be titrated with the FAS for calculation. Now in blank sample there is no impurity which means whole Potassium Dichromate is to be titrated with FAS and consumed more in Blank. that's why Blank reference is also considered in in the testing.
      hope this will help you.

  • @tdsontrack6241
    @tdsontrack6241 2 года назад +1

    Thanks for this video sir. 🙏

  • @sainanamrangcharai6611
    @sainanamrangcharai6611 Год назад

    Nice concept sir Ji 🙏

  • @दिलसेपहाड़ी-ध9ल

    Sir have a question . Your Burrett reading is approx 10 to 11 how can possible this in two different normality of solutions 0.25 and 0.1N.

  • @jayantanaik4583
    @jayantanaik4583 2 года назад

    Very helpful.

  • @ShamaParveen-zo4hp
    @ShamaParveen-zo4hp 2 года назад

    Understandcompletely
    Thanks

  • @angelneha9651
    @angelneha9651 2 года назад

    Good knowledge 👍

  • @IndianCurrywithNeha
    @IndianCurrywithNeha 2 года назад

    Nice explanation sir

  • @maditetiontimenittu2869
    @maditetiontimenittu2869 2 года назад +1

    Sir BOD,TDS,PH,DO,etc test ka video pura with regent and calculation ka banaye

    • @bhanu_sangita
      @bhanu_sangita 2 года назад

      Bilkul sir aapka video bahut hi helpful hai.
      Plz above topic pe bhi video banaiye.

  • @ajayawara5221
    @ajayawara5221 2 года назад

    Nice video

  • @pankajkumar2210
    @pankajkumar2210 2 года назад

    Thanks 🙏👍🙏👍

  • @haripatel9468
    @haripatel9468 2 года назад

    Thank you sir !

  • @arushupadhyay2894
    @arushupadhyay2894 Год назад +1

    Audio is very low please solve this

  • @thakurduttsharma705
    @thakurduttsharma705 2 года назад

    Each single point understand clearly

  • @sokunlehakeem
    @sokunlehakeem 2 месяца назад

    Can it be done in English? Also is it compulsory to digest the sample? Why can't we titrate it direct

  • @shivamdiwakar4610
    @shivamdiwakar4610 Год назад +1

    Good morning sir, mere pass pure sulphuric acid hai ,mujhe 98% concentrated sulphuric acid bnana hai kaise bnaye ,plz help me sir or anyone

    • @aquazoneengineering3556
      @aquazoneengineering3556  Год назад +1

      Purity of Sulphuric acid is 98%, you don't have to do anything. It is already 98% concentrated.

    • @shivamdiwakar4610
      @shivamdiwakar4610 Год назад

      @@aquazoneengineering3556 okey thank you so very much sir

    • @shivamdiwakar4610
      @shivamdiwakar4610 Год назад

      Sir stp me COD ke liye 150 temp rkhte h for 2 hour but hmare COD digester me 100 tk hi temp h toh kitna temp rakhe ham

  • @Digital_Guidance
    @Digital_Guidance Год назад +1

    Dm water kya hota hai sir ne bataya tha 3:30 seconds par koi batayega?

    • @aquazoneengineering3556
      @aquazoneengineering3556  Год назад

      De-mineralised water, aisa water jisme TDS less than 0.9 ho. And conductivity 1.2 .

  • @shikhajha4035
    @shikhajha4035 Год назад

    Sir is there no need of COD digestor for the process to occur

  • @chukwumaonyeka29
    @chukwumaonyeka29 Год назад

    Please, how is sample dilution 10?

  • @oumnourhadj4221
    @oumnourhadj4221 Год назад

    thank you so much ,but measure of sécurité out , normalement sous haute chimique il y'a un risque pour votre santé

  • @bhavikamehta1434
    @bhavikamehta1434 7 месяцев назад

    Kya iske reference ka link bhi upload kar sakte hain please?

  • @bhanu_sangita
    @bhanu_sangita 2 года назад

    USBR technology ka video upload kijiye sir

  • @zishan396
    @zishan396 Год назад

    My sample titration always exceeds blank sample by this method. Y this error occurs

  • @sheshnishad9803
    @sheshnishad9803 2 года назад

    Sir Benzyle salicylate acid value
    Method and farmula

  • @chakrigollapalli6062
    @chakrigollapalli6062 Год назад +1

    8000 is f.a s factor sir

  • @mrmaniar1555
    @mrmaniar1555 2 года назад +1

    What if we don't heat for 2 hour so the results will be higher or lower than actual results

    • @aquazoneengineering3556
      @aquazoneengineering3556  2 года назад +1

      Could be any of them, most of the time it may show higher then actual, because digestion would not take place properly.

    • @mrmaniar1555
      @mrmaniar1555 2 года назад

      @@aquazoneengineering3556 thanks bro I have doubt now cleared basically I am ETP and ro incharge what about u

  • @dartahir6090
    @dartahir6090 2 года назад

    Sir can you tell me which sop followed for COD determination , I want to know that sop

  • @chavdaharesh-vo5mv
    @chavdaharesh-vo5mv Год назад

    Blenk 24.25 no vche Avu jove evu kaik hoi chhe

  • @sandeepatiketi1268
    @sandeepatiketi1268 6 месяцев назад

    Why ...we take 8000....what is it's mean

  • @dhananjayk130
    @dhananjayk130 Год назад

    5 ml potassium dichromate Pipette se kyu nahi dala

  • @rakeshbeniwal6505
    @rakeshbeniwal6505 2 года назад

    Complete test BOD parameter video uploaded sir

  • @dilipparihar279
    @dilipparihar279 5 месяцев назад

    Mughe sikhna h

  • @chavdaharesh-vo5mv
    @chavdaharesh-vo5mv Год назад

    Hi

  • @hiddenstr4098
    @hiddenstr4098 Год назад +1

    aap 98% h2so4 without hand gloves addition kar rahe ho or pure video me aapne kaha bhi hand gloves nahi pehna.
    #safetyfirst
    aapko lab safety ke bare me padhne ki jarurat hai..
    ye video ko dekh ke lab chemists per galat impact aa sakta hai.