Solinoid valve. RO unit switch off la irukumbothu water reject la vanthutu irukum.. so pump run agumbothu matum water flow irukanunu than sv use panrathu..
Ro membrane product water slow va drop drop ah water varuthu bro...wat is the problem...new membrane potalum work agalA bro...pumb water pressure it's also good... waste out water 450 pressure problem vandha kuda edhumathuri aguma bro
RO booster pump heads come in different sizes based on the brand and model. Common sizes are 1/4 HP and 1/2 HP. They may not fit all systems, so it's best to check your pump's specifications or ask a supplier for compatibility.
I am change me around, spunfilter,and, post carbon filter,sediment filter,,precarben filter but water taste not good what problem my ro system ple comend,
TDS (Total Dissolved Solids) refers to the total amount of dissolved substances like minerals, salts, and metals in water, measured in parts per million (ppm). It helps assess water purity
Bro na ella filteryum mathiten membranyum mathiten ana ipa reject water romba slow VA varuthu protect water line LA athikama varuthu athum bore la vara tds alavaye varthu reject water um atheya tds tha varthu ena problem MA iruku line la correct ah tha koduthureken
Bro today 13/08/2020 Nan membrane inlet filter and sv change pannen but pure water slow va varuthu reject water athigama varuthu one cup pure water varathuku 4 cup reject water varuthu Ithuku Nan ena seiyanum idea sollavum 9865535346
Beautiful explanation bro.
Super bro sema idea
Yenna ro systemla rejected water nalla varudhu, but product water verum drop drop than varudhu... Yenna problema irukkum?
May be low pressure from the booster pump or the membrane may have damaged
Its very useful anna
Super bro good technical knowledge
bro filters enga vanguradhu nalla irukum.onlinela vangalama.vera enga kidaikum
Ro filter tank evlo narathil full again vandum
Brooo, New membrone change panniyachi but waste water varuthu product water varala... Enna bro seivathu... Pls solution
First, check the pressure of the booster pump. If it's okay, then check the flow restrictor (FR). The problem will definitely be in one of these two.
Super thala kalikkittel poonga
Anna RO la sv ethuku ?
Solinoid valve. RO unit switch off la irukumbothu water reject la vanthutu irukum.. so pump run agumbothu matum water flow irukanunu than sv use panrathu..
@@r2_tech_tamil thanks anna
Hi bro I'm using livpure pep pro ++ taste enhancer... Yearly filter cost
Tds check pandrathu ethuku brother?
result of water..
Ro membrane product water slow va drop drop ah water varuthu bro...wat is the problem...new membrane potalum work agalA bro...pumb water pressure it's also good... waste out water 450 pressure problem vandha kuda edhumathuri aguma bro
Fr 450 problem vandha... product water slow va erukuma bro
no pump than work agala.. pressure kedaikala.. change panunga
Bro low pressure switch price?
Exelent.
Tds level 132×10 how to originally water tds.? 1320 is correct?
Yes.
@@r2_tech_tamil thanks🙏
Intha video la antha RO taste varumma
Super,
any ro booster motor head are same size head please tell me
RO booster pump heads come in different sizes based on the brand and model. Common sizes are 1/4 HP and 1/2 HP. They may not fit all systems, so it's best to check your pump's specifications or ask a supplier for compatibility.
I am change me around, spunfilter,and, post carbon filter,sediment filter,,precarben filter but water taste not good what problem my ro system ple comend,
First check the TDs of the product water..
If TDs is above 100 maybe membrane or pump issues there
@@r2_tech_tamil thank u very much
Anna can u explain about tds pls
TDS (Total Dissolved Solids) refers to the total amount of dissolved substances like minerals, salts, and metals in water, measured in parts per million (ppm). It helps assess water purity
Bro can we able to check RO taste by connecting directly RO membrane without other filters. Is that possible Apdi na antha video podunga
உங்க சேனல் எனக்கு ரொம்ப பிடிக்கும் நிறைய வீடியோ போடுங்க உங்க போன் நம்பர் சொல்லுங்க ஜி..
Super sir
Product watter dast illa enna matthanum
All filters change pananum.
G carbon, sediment ithu ellam thane unga name number kodunga my number 8883566697
Enna bro ipdilam videos potta epdi bro ro engineer lam work pannamudium mathavangalaium yosinga bro seriya
அடிக்கடி membrane போக காரணம் என்ன
Bro na ella filteryum mathiten membranyum mathiten ana ipa reject water romba slow VA varuthu protect water line LA athikama varuthu athum bore la vara tds alavaye varthu reject water um atheya tds tha varthu ena problem MA iruku line la correct ah tha koduthureken
Membran housing change panni parunga illana input output water Mari irukum membrane housing la
Livepure membrane neegah use pana housing la set agum ah. And evolo varuthu new membrane housing .
600+
Dow use pannuinga
👍👌
TDs 500 kil erukakudathunu sluranga
Solranga.. But inum 4 months time ketrukanga.. So aghukula ena venunalum nadakalam.. Even ithanala can water business full.ah washout agidum..
👍🏾
Fr fault ta eruku bro
Water coming very slow
Bro today 13/08/2020 Nan membrane inlet filter and sv change pannen but pure water slow va varuthu reject water athigama varuthu one cup pure water varathuku 4 cup reject water varuthu Ithuku Nan ena seiyanum idea sollavum 9865535346
normally ratio 1:3 or 1:4 than.. TDs high.a iruntha ipdi varalam. romba slow.a vanthathuna maybe pump pressure low.ah irukalam. check panathan confirm panamudium
Bro unga whats app number kodunga