Sir ups ki inveter sait ki 3fet ki value nh ban rahi he drive card bhi cheng karilya he or 220 smd or 49 k smd bhi check karily he sir in ke elwa kis me masila hosakita he sir
Hi friend! Meray inverex aerox 2.2kva Kay battery terminals short show Kar raha hay aur ups on bhi nahien hota. Chzzzz ki sound bhi aa rahi hay. What could be the problem? Plz help
Nice video mara ups battery or wapda dono par fault zero show karta ha ,wapda in wire ka pass jo chota sa transformer laga hota ha wo nh ha,,iska hal kya ha ji
Shmraiz sir nice video. Sir mera ups ka b yhi fault tha or me na bilkul Asa he repair Kia h ap ki is video ki help se pr ab wo lcd pa overload show krta rahta h jabka koi load nai lagaia hoa me na bhi kuch is Bara me ap bta dain comment section me he
sallm bhai g mara ups h jo sab worak par h 7 waats ki led par backup bettey pr work krta h bettey chrage b krta h lekan jab load zeda krn jasy fan ya or ak light zeda on krn to fuolt 0 par chla jata h
@@engineershamraiz thanks, men nay fan change kr k dekha hai laken wi he issue hai, jaisay he ups ko wapda men lgata hon ups par random load show hona shru ho jata hai jb k output ka plug b nikala hota hai, aur jaisay he wapda ka switch nikal deta hon batteries par theek chalta hai.
@@engineershamraiz I have checked the voltages, 100 watt k bulb k sath output voltages 195 volts aty hen DMM par aur without 100 watt bulb 185 volts aty hen. Ups model is hexa 2004
@@engineershamraiz jb k ups ki screen par output voltages 227 say 230 k darmian show ho rhy hotay aur dmm par output voltages 185 without load abd 195 with load show hotay hen.
Dear sir mery pas homage ky purany wale model ky 5 ups ha jo kh bekul Dead ha us my Kiya fault huskta ha tura guide Karen please muhy tura sa idea den thanx
ap ki vedeo buhat helpfully hai
Agr ye fets thik hun to kis me masla hoga.. jab k fault 0 hi aa rha hai
intahai Fazool video hai
Kuch samjh nai a raha
Sir ups ki inveter sait ki 3fet ki value nh ban rahi he drive card bhi cheng karilya he or 220 smd or 49 k smd bhi check karily he sir in ke elwa kis me masila hosakita he sir
Very nice and good video sir thanks
Rahim
Sir ye problem shop wala kitny peso me karleta hey... Matlab jaiz isper kitna kharcha ataa hey??
Rauf DC booster ki output aur inverter side k fet check kren ager ok hen to output relay change kren
Sir g hamara ups phase change krata hạn. Jab bijli jate hạn tu phase chang karta hạn. Ye kia masla hosakta hain?
Hi friend! Meray inverex aerox 2.2kva Kay battery terminals short show Kar raha hay aur ups on bhi nahien hota. Chzzzz ki sound bhi aa rahi hay. What could be the problem? Plz help
fan auto chalyga
ya chalta rahyga
fault 0 muramat karne par
Nice video mara ups battery or wapda dono par fault zero show karta ha ,wapda in wire ka pass jo chota sa transformer laga hota ha wo nh ha,,iska hal kya ha ji
Fault 3 ko kasy solve krogy...
Plzzz ans me...
Solar inverter omega company Wala
What is the price of FT?
Ap ya beh bata dya karin k y folt thek karny k amount kitna hon gy
Salam sir.. Homage inverter hai kabi 0 fault aata hai kabi nai aata ye kia fault hoskta hai.. Plz reply.
Main bijli pr thek hai charging b krta hai.. Battery Load pr kabi 0 fault deta hai or kbi nai.
Wiring check krwaen ups ki
Fan smooth chalta he ya sound krta he
Thanks for reply.. Sir fan b smooth hai nd wiring mein problem nai hai q k dusra homage inverter lagaya hai wo thek kam kr raha hai
Aoa
Bhai jan
Mery pass homage ka inverter ka ups hi load per 0 falut show krta hi
Us main kia problem hi plz guide me
Good tiching karte hai 👍👌👍👍👌👌👍
Bhai apki shop kidhar hay? I want to get my UPS repaired
Islamabad
Barma town
Sir Mera homage ups sirf wapda pay fault 0 day raha kya Karon battery pay OK hai
Shmraiz sir nice video. Sir mera ups ka b yhi fault tha or me na bilkul Asa he repair Kia h ap ki is video ki help se pr ab wo lcd pa overload show krta rahta h jabka koi load nai lagaia hoa me na bhi kuch is Bara me ap bta dain comment section me he
sallm bhai g mara ups h jo sab worak par h 7 waats ki led par backup bettey pr work krta h bettey chrage b krta h lekan jab load zeda krn jasy fan ya or ak light zeda on krn to fuolt 0 par chla jata h
Sir high volt ka baad 0 falt ha iska solution
جزإک اللہ
Sir very nice informission and thank u so mch for guid us sir
Very nice video thanks sir
bhai nice video.mere paas primus p-1200 ups hai baaqi ok ha battery charging 13.50v se uper nahi kerta please telme
Us me selection ho GI battery voltage ki
Pic send kren
WhatsApp per
0334 6562265
Sir mere pas apollo ka ha fault 0 show kr rha ha 740 b sb ok bta rha ha phr or kia problem ho skta ha plz guide
3205 check kren
@@engineershamraiz wo b thk hen check kr lia
Sir mai ne homage tron due 800w lia hai.. 1 to wo late on hota hai or 0 fault show kar rha hai..
Kitna time k baad?
2 din se chala rha hon.. Or masla hal hua q k battery 8.v pr tha usko charge kar k lagya to ups on hua phir se.. Thanks for reply
Maray pas homage ka inverter hai wo battery par theek kaam krta hai jaisay wapda ka switch lgatay hen fault 0 any lag jata hai
Fan change Kar k check kren
@@engineershamraiz thanks, men nay fan change kr k dekha hai laken wi he issue hai, jaisay he ups ko wapda men lgata hon ups par random load show hona shru ho jata hai jb k output ka plug b nikala hota hai, aur jaisay he wapda ka switch nikal deta hon batteries par theek chalta hai.
@@iparvaizahmad
Battery per on Kar k output voltage measure kren and load Chala Kar phir output voltage measure kren
@@engineershamraiz I have checked the voltages, 100 watt k bulb k sath output voltages 195 volts aty hen DMM par aur without 100 watt bulb 185 volts aty hen. Ups model is hexa 2004
@@engineershamraiz jb k ups ki screen par output voltages 227 say 230 k darmian show ho rhy hotay aur dmm par output voltages 185 without load abd 195 with load show hotay hen.
Shamraiz sir
Homage ups m fault 3 ka kia mtlb hta h aur usko kaisay repair kia jae.??
Inverter side ki fet faulty ho GI
Irf 740 check kar k replace kren
@@engineershamraiz
Boht mehirbani
nyc
Mr E&E HD homage ups ka zero fault ki video
Dear sir mery pas homage ky purany wale model ky 5 ups ha jo kh bekul Dead ha us my Kiya fault huskta ha tura guide Karen please muhy tura sa idea den thanx
Konsa ups he vision 1000 ya 2000 he apke pass
Bohat ache ups hen WO
Dead se Murad bilkul b on nahi hote matlab beep b nahi dete kiya?
1000 ka ha aor beep be nahi dy raha
@@engineershamraiz belkul on nahi huta
G belkul on nahi huta sir us my abi check kiya ak feet shot ha sir aghar Whatsapp number ha tu my us ke pic send kar dunga
Sir homage ma Lod dalny per falude 0 ata ha piz bata dy
Inverter FETs me fault he ya output relay kharab he
bhot shokreya
Sir mene bhi aisa kya pr load dene k baad phr se same problem show kr rha h
Sir ups ma fault 2 ka option aa rya ha fault 2 kaun sa fault ha
Bhai ups ka board check krne se hi pta chal sakta he
Mere NS ups mn wapda p fault zero aata h.. is Ka koi solution
Kiya battery per thek chalta he means k load uthata he?
Aur charging volt kitne hen
Kiya kabi kabi fault 0 ata he
Sir mera inverter wapda or battery dono pey beep or fault 0 dey bata raha hai kia masla hoga sir
Irf 740 check kiye hen ?
Ecostar ups py f0 a rha hai on hoty he 315v out put hotey hain f0 ajta hai
Charging section me fault he
Sir mera cyber power ka ups e18 ka code day raha hai or beep bhi day raha hai kia fault hoga sir isme
Ups open kar k check kren multimeter se
Fet booster and inverter side ki
Thanks sir
Homeage ups ki diagram mil sakti hy
Sorry
Thanks sir
Nice
thanks
Apny time ka behtreen ups tha ye model
exilent
Mare pass inverex xp 1500 error 00
Inverter section ka fault he
No entendí ni maíz
Sir, mera UPS bhi fault 0 deta hai, i have checked all FETs aur sab sahi hain, is ke ilawa kahan problem ho sakta hai?
Why put an English title and speak in durka durka?
F00 fault solve
Sic g men ic
Rahim