Комментарии •

  • @FactualCivilEngineering
    @FactualCivilEngineering 5 лет назад +4

    If any questions, please comment below.

    • @vishvendrasinghchoudhary9369
      @vishvendrasinghchoudhary9369 5 лет назад +1

      Sir hieght wali bat code m nhi h

    • @ankushnowal
      @ankushnowal 4 года назад

      Sir column ki shuttering kis height tak ayegi?

    • @rajivsingh9012
      @rajivsingh9012 4 года назад

      sir when we take measurements in running meter.if its less than 200 mm or 150 mm

    • @arnabpatra52
      @arnabpatra52 3 года назад

      Single layer scaffolding ER schedule rate Kaya ha..

    • @kaushikc235
      @kaushikc235 7 месяцев назад

      Is 100 mm Pcc shuttering payable?

  • @kamalmishra3628
    @kamalmishra3628 4 года назад +1

    Sir column ki shuttering slab bottom tak consider karenge ?

  • @ImperfectBelievers
    @ImperfectBelievers 4 года назад

    Good Work Sir... keep posting such informative videos

  • @MrGovarathana
    @MrGovarathana 5 лет назад +2

    Sir,
    One doubt
    In over head tank
    RC wall inner side another wall continues then inner side shuttering shall we deduct or not..

  • @rainbow9649
    @rainbow9649 2 года назад

    Bhai pasand nhi bhot pasand aai aap ki video
    Thanks

  • @highwayguidecivilwalk
    @highwayguidecivilwalk 5 лет назад

    Very knowledgeable video thanks a lot

  • @kaushikc235
    @kaushikc235 6 месяцев назад

    Is PCC shuttering quantity to be consider in billing as per IS 1200?

  • @MrGovarathana
    @MrGovarathana 5 лет назад +1

    Sir,
    Please tell how to measure Staging measurement.
    Wheatger we will give staging measurement for both
    1.Concrete
    2.Reinforcement.
    Or one time it's enough..

  • @atulkanawade9859
    @atulkanawade9859 2 года назад +1

    Dear Sir..
    In the Case form work
    Opening upto 0.4 SQM is not deducted..
    But in the Case of Opening if Column Cross section more than 0.4 SQM is deducted or not ..
    Opening is not mentioned ...
    My Client deducted opening of Colum from Slab Shuttering...
    Please Guide

    • @kabeermeerahlawat8476
      @kabeermeerahlawat8476 Год назад

      column cross section area will be deduction from the slab area its site rules (ultra tech cement Ltd Tadipatri, APCW line project)

  • @wonderingcivil8808
    @wonderingcivil8808 Год назад

    Thanks

  • @gaganap6603
    @gaganap6603 2 года назад

    Great

  • @MeghnaBiswas-o5h
    @MeghnaBiswas-o5h 8 месяцев назад

    Ek cover area billing video banaye sir

  • @modassariqbal306
    @modassariqbal306 5 лет назад

    Sir Rcc slab me kaun kaun s openings area and kain Kaun s duct deduct hota hai contractor k Area nikal kr bill dene ko sir...

  • @harshalgadhia
    @harshalgadhia 3 года назад

    Nice sir

  • @jtgeete
    @jtgeete 6 лет назад

    Very knowledgeable video

  • @adarshkumar-qx8cp
    @adarshkumar-qx8cp 3 месяца назад

    Nice

  • @civiltechwithap7144
    @civiltechwithap7144 4 года назад

    sir,
    plz suggest me which book is best for QS and Billing engineer which book can use by experienced person.

  • @mdnakiullah4079
    @mdnakiullah4079 7 месяцев назад

    Sir can we take shuttering qty for PCC side face?

  • @Deepakkumar-812
    @Deepakkumar-812 5 лет назад

    Amazing video sir

  • @kumararvind8357
    @kumararvind8357 4 года назад

    मेरा दो सवाल है,
    1॥डबल height shuttering me सिर्फ कॉलम की height क्लेम होती है या और भी कुछ.
    2.agar slab का thickness 200mm से ज़्यादा है तो एक्सट्रा item के तौर पे हम क्या क्लेम कर सकते हैं

  • @waitwaititsdp1791
    @waitwaititsdp1791 6 лет назад

    Factual knowledge ....good one

  • @MrGovarathana
    @MrGovarathana 5 лет назад +2

    In shuttering
    Labour bill
    Tie rod measurement?
    1.In RC wall both inner and outer tie rod fixed.
    One plywood - 8Tie rods connected.
    How many nos we will give measurement
    8 nos or 16 Nos

  • @hjadav57
    @hjadav57 4 года назад

    Sir mera 1 sawal he ki mera water tank kam chalo he 12mm ka steel he 150c/c he jo niche me lag gaya he upper lep karna to khatam hogaya he but mere pass only 8 mm ka steel he to me ushka lep ketna c/c karo kg b mech karna he steel ka ye wall k leye poch raha hu PL answer jaror dena sir.

  • @rex_montis2125
    @rex_montis2125 Год назад

    What is height of column taken in formwork if slab height floor to floor 3.6 m and slab thickness is 0.15m.

  • @mayanksharma9007
    @mayanksharma9007 3 года назад

    Sir Billing Engineer k liye koi course launch kijiyega Plz.. Sir How i can contact you

  • @456895421
    @456895421 4 года назад

    Dear,
    I need bs and us standards.
    Also Redbook and Fidic.
    Regards
    Alphyn P

  • @VenuGopal-po7wj
    @VenuGopal-po7wj 4 года назад +1

    Sir if I take slab area for shuttering,if columns opening area less than 0.4 m2 ,there will be no deduction for column area sir

  • @govindsingh8168
    @govindsingh8168 4 года назад

    🙏 🇮🇳 👍 😍

  • @ManojKumar-vj7kx
    @ManojKumar-vj7kx 5 лет назад

    Agar column ka size 2.0 m ka hai or Beam ka size 1.0m X 1.5m hai to kya deduction nahi hoga

  • @MrShaikhzaid
    @MrShaikhzaid 4 года назад +1

    Kya slab thickness deduct hoga? In case of inner side column shuttering. IS code m yeh baat nhi di hui hai. Pls reply.

    • @FactualCivilEngineering
      @FactualCivilEngineering 4 года назад

      Di hui h, column should be measured upto bottom of slab

    • @MrShaikhzaid
      @MrShaikhzaid 4 года назад

      @@FactualCivilEngineering Thanks Sir. Also explain reason behind that.

  • @mukeshmani2003
    @mukeshmani2003 4 года назад

    spacing between two props under the beam and slab both.

  • @aashishsharma6964
    @aashishsharma6964 4 года назад

    Sir
    Edge of slab and breaks in floor and wall ki measurement kaise lenge.

  • @mayanksharma9007
    @mayanksharma9007 5 лет назад

    Sir ydi secondry beam m aakr koi dusri secondry beam judti hai.. To us conditions m seondry beam ki side se jo beam ka jo cutout area bnta hai... Vo minus hoga ya nhi... Reply plz...

  • @biting.scorpio
    @biting.scorpio 6 лет назад

    Very good

  • @shafatali1627
    @shafatali1627 6 лет назад

    sir apnay antitermite aur backfilling ka video ni upload kiya.

  • @shafatali1627
    @shafatali1627 6 лет назад

    sir edges of slab jo hoti h usko running metre may measure krtay h ki ni . sir generally shuttering square metre may krtay h pr kaha kaha pr running metre may krtay h . plz reply me.

    • @FactualCivilEngineering
      @FactualCivilEngineering 6 лет назад

      Shafat Ali All kind of shuttering / form work measured in sqm as per IS Code, and Only touch of concrete area measured for payment in footing, column, slab, beam etc.

    • @shafatali1627
      @shafatali1627 6 лет назад

      sir BOQ may diya h usmay muje 1 doubt h.

    • @FactualCivilEngineering
      @FactualCivilEngineering 6 лет назад

      If it is described in BOQ item than we meaured in running meters,

  • @Bharatinfra02
    @Bharatinfra02 3 года назад

    Sir column waala point fir se samjha dijiye

  • @kamalmishra3628
    @kamalmishra3628 4 года назад

    Sir 3mm thick polycarbonate sheet ka rate analysis karna hai DAR me nhi mil raha labour and material ka sheet ka price 70 rs per sqft hai

    • @FactualCivilEngineering
      @FactualCivilEngineering 4 года назад +1

      Ok, i will prepare for it

    • @kamalmishra3628
      @kamalmishra3628 4 года назад

      @@FactualCivilEngineering thanku sir
      Sir maine apko mail kiya tha kal cash flow ki sheet ke liye sir mail kardenge to help ho jayegi meri thodi

  • @vishvendrasinghchoudhary9369
    @vishvendrasinghchoudhary9369 5 лет назад

    Sir extra iteam ke lie konsa is code kahta

  • @shahulhameed9261
    @shahulhameed9261 6 лет назад

    Is there any mode of measurements for solids concrete block work

    • @FactualCivilEngineering
      @FactualCivilEngineering 6 лет назад

      Shahul Hameed its depend on work order BOQ Item, generally its measured in sqm for 100mm & 200mm thick block works

    • @shafishaikh1281
      @shafishaikh1281 4 года назад +1

      @@FactualCivilEngineering sometimes it is only measured in sqmt for 100mm and more than that can be measured in M3.

  • @AshishhP1209
    @AshishhP1209 8 месяцев назад

    Main aur secondary beam wala agar dimension consider krke smjhate toh aur jyada clear hota, smjh mei aaya hi nahi.
    Main beam
    length 5m width 0.3
    Secondary beam
    Length 4m width 0.3
    Then
    Shuttering will be
    5*0.3=1.5 sqm
    4*0.3=1.2 sqm
    Cutout wala smjh nhi aaya

  • @shafatali1627
    @shafatali1627 6 лет назад +1

    sir 1200 k aur Bhi part upload kryay. plz

    • @FactualCivilEngineering
      @FactualCivilEngineering 6 лет назад +1

      Please send your mail id, i will send you SP27 book for all IS 1200

    • @amitsaini1145
      @amitsaini1145 3 года назад

      @@FactualCivilEngineering pls s nd me SP 27

  • @kumararvind8357
    @kumararvind8357 4 года назад

    Arch का shuttering and concrete Qty का फॉर्मूला क्या है

  • @rajatmehta7682
    @rajatmehta7682 4 года назад +1

    In case we claim shuttering extra for height more than 3.5 mtr. Can you let me know how to claim for height of 6 mtrs. Plan area can be considered 100 sq mtrs. Please do reply

    • @FactualCivilEngineering
      @FactualCivilEngineering 4 года назад

      6 - 3.5 = 2.5 mean 3 times of plan area (3 x 100 Sqm) for a seperate rate of extra height for per metre height

  • @shafatali1627
    @shafatali1627 6 лет назад

    Good morning sir, sir IS1200 part 5 k page no 7 pr (m) serial no h usmay jo likha h edges of slab and breaks in floor and walls . sir yeah point smja diyay muje.

    • @FactualCivilEngineering
      @FactualCivilEngineering 6 лет назад

      Yes you are right End edges of slabs / balcony are measured in running meters upto 200mm thickness, but practically end of edges merged in outer side of beamand most of BOQ items of measured in sqm due to various thikness of slabs,

    • @mayanksharma9007
      @mayanksharma9007 5 лет назад

      Sir ye ab bhi clr nhi hua ho ske to ek sketch bna kr dal dijiyegaa... Ki end edge kaise running meter m nape... Kyoki hm to balcony slav ko bhi area m napte hai

    • @FactualCivilEngineering
      @FactualCivilEngineering 5 лет назад +1

      Dear Mayank, its only horizontal for slab fins case

  • @princesharma-cg6sc
    @princesharma-cg6sc 6 лет назад

    Please uplaod all parts

  • @AmitKumar-fj2ih
    @AmitKumar-fj2ih 6 лет назад

    Sir plywood ka density kya hota hai..

    • @FactualCivilEngineering
      @FactualCivilEngineering 6 лет назад

      According to IS 875 Part 1 ( Page No. 16) density of plywood should be 700kg / cum minimim, used for construction works, also you can watch my video Density of Building Material

  • @kumararvind8357
    @kumararvind8357 4 года назад

    गोल calumn की shuttering निकलने का फॉर्मूला क्या है

  • @ramkumar-rt9oi
    @ramkumar-rt9oi 5 лет назад

    Kindly tell me scaffolding measurement

    • @FactualCivilEngineering
      @FactualCivilEngineering 5 лет назад

      Dear Ram, Scaffolding measured in two types Sqm OR Cum, as 1. paint, plaster, masonry, vertical surface works in Sqm and 2. Under shuttering case for slab supports in cum

    • @sukumarn4830
      @sukumarn4830 5 лет назад

      @@FactualCivilEngineering I tnk cum not come.
      =(L+b)*h
      Like this come this also comes under sqm

  • @vishvendrasinghchoudhary9369
    @vishvendrasinghchoudhary9369 5 лет назад

    Sir ye hieght wali bat to code m h hi nhi

  • @visheshmittal5287
    @visheshmittal5287 3 года назад

    Thanks