I Drill BETTER Than Artisan!- Ev Charger

Поделиться
HTML-код
  • Опубликовано: 19 фев 2024
  • come and join me and Mitch installing my first zappi charger
    Get 10% off Rhino Trade Insurance using code BUNDY10 at www.rhinotradeinsurance.com/quote
    Ansell gloves i wear ruclips.net/user/redirect?even...
    Use code BUNDY25 at unilite.co.uk/product-categor... for 25% off
    Use code BUNDY10 at www.expertelectrical.co.uk for 10% discount
    Join this channel to get access to perks:
    / @nbundyelectrical
    This video is for entertainment purposes only and is in no way intended as a guide or 'how to'.
  • РазвлеченияРазвлечения

Комментарии • 108

  • @NBundyElectrical
    @NBundyElectrical  3 месяца назад +4

    youtube.com/@brightsparkmid?si=kZyz5_FmffTQct4D mitches channel, go show him some love and get him to 1K

  • @ukprometheus
    @ukprometheus 3 месяца назад +31

    You keep mentioning Adams mum, i think its about time to get a picture posted up so we all can judge :)

    • @justme5384
      @justme5384 3 месяца назад +5

      Maybe she's like Howard's mom, always heard and talked about but never seen

    • @harnoorsingh1809
      @harnoorsingh1809 3 месяца назад

      Fair enough 😂 ​@@justme5384

  • @Dave_MacG
    @Dave_MacG 3 месяца назад +7

    Loving the bants between you and Mitch. You seem a lot happier now that you are working along side someone again 👍🏻

  • @buzzyphantom
    @buzzyphantom 3 месяца назад +4

    You don't need to use the screwdriver in the release when you are connecting it up, the release is for getting the cable out. Which is why you were struggling to get the screwdriver into the release, also the label is because some sparks were pushing the cable into the release slot and not the cable slot, so the terminals were burning out.
    Nice bit of rear entry and angle drilling! Bet you were over the moon when you missed the metal tie 🙂

  • @simonthug7866
    @simonthug7866 3 месяца назад +2

    Nice to see some EV work!

  • @Malandrin
    @Malandrin 3 месяца назад +7

    for one moment I thought I was watching a video from artisan 🤣🤣 jordan loves that ev charger

    • @stuartandrews4344
      @stuartandrews4344 3 месяца назад

      Zappi, superb charger, my EV charger of choice.

  • @sergiofernandez3725
    @sergiofernandez3725 3 месяца назад +2

    On the depth of that cable in the ground I think the 600mm comes from the cable layed in the street at the incoming service. Same for water mains. I do agree that the patio slab does offer some protection and it is clear with the cables either side.
    If it were SWA in a cultivated feild it would be minimum 1000mm it a 2396 Electrical Design question.

  • @artisanelectrics
    @artisanelectrics 3 месяца назад +3

    Haha you wish mate...

  • @richrowley8355
    @richrowley8355 3 месяца назад +1

    Nice one Nick.

  • @electrician247
    @electrician247 3 месяца назад

    Nice job fellas, enjoyed that!

  • @gsdevme
    @gsdevme 3 месяца назад +1

    You should keep that silica gel pack inside the Zappi as per the install instructions not discard it just FYI. helps keep things dry if there is any moisture creeping in slightly.

  • @mylesie8078
    @mylesie8078 3 месяца назад +2

    You guys sounding like Dave Savery and Mr Marsh...good laugh...carry on 😊

  • @TheChipmunk2008
    @TheChipmunk2008 3 месяца назад

    The Bright Bundy Drilling Co... shades of 90s simpsons

  • @Gjbsecurityandalarms
    @Gjbsecurityandalarms 3 месяца назад +1

    Do you know how good it is to see you joking and happy mate. I know you’ve been through a lot and I’m happy your happy hears to a great year ahead

    • @brightsparkmid
      @brightsparkmid 3 месяца назад +1

      Nothing better than some positive comments like that to brighten a blokes day ❤

  • @sergiofernandez3725
    @sergiofernandez3725 3 месяца назад +1

    Good stuff Nick.
    Get a few t-shirts made up. BrightBundy Angle Drilling and wear on a video for a laugh.

  • @alanbaltic
    @alanbaltic 3 месяца назад +1

    Missed opportunity in Spit firing that huge Spider! 😢

  • @TheChipmunk2008
    @TheChipmunk2008 3 месяца назад

    4 channels? We had 3 channels and we liked it!

  • @samuelprowse6708
    @samuelprowse6708 3 месяца назад

    That spider was humongous

  • @MarcusNailor
    @MarcusNailor 3 месяца назад +1

    Wonder if anyone makes black tray, could look pretty badass if you made it part of the decor in part of the house 👀

  • @jgrange6705
    @jgrange6705 3 месяца назад

    What work trousers do you wear?! Thanks love the channel😊

  • @estelle6660
    @estelle6660 2 месяца назад

    Ziet er netjes uit. Kunnen sommige installateurs nog een voorbeeld aan nemen!

  • @AndrewStrydomBRP
    @AndrewStrydomBRP 3 месяца назад

    Honestly the size of the Zappi looks like it would be so much easier to terminate, and with rear or bottom entry whereas some of the smaller chargers only allow bottom entry

  • @jd2515
    @jd2515 3 месяца назад +1

    Mate you have fast become one of my favorite RUclipsr! If you do Northwest id like to hire you to do a board Change at my property!

  • @williamyates2794
    @williamyates2794 3 месяца назад +1

    How does installing a zappi pay for 2 sparks 🤔 curious

  • @markwestwood2016
    @markwestwood2016 3 месяца назад +1

    service cable for national grid only goes in at 450....

  • @delspark
    @delspark 3 месяца назад

    could of used the next size up for the d-line if installed correctly look great no 10mm hole like the linian clips

  • @66johnpaul
    @66johnpaul 3 месяца назад

    Although not required to be 600 deep, some cables can be damaged by frost / constant moisture etc if in shallow ground...think it may be down to manufacturer reccomendations. 👍
    Tidy job though, have your tools got DSES on them 😂

  • @trojanhawrs4613
    @trojanhawrs4613 3 месяца назад +3

    I'd prefer to use armour when burying, agree about being safe enough under slab though. Probably wouldn't have bothered with the kopex, ideally you want anything metal like that earthed. Cable should be RCD protected anyway unless it's armoured or clipped direct.

    • @brightsparkmid
      @brightsparkmid 3 месяца назад +1

      It has 30ma rcd protection at the board end
      Kotors is insulated too

    • @trojanhawrs4613
      @trojanhawrs4613 3 месяца назад +1

      @@brightsparkmid I know, armour is insulated too I'd still rather earth it. I did assume you'd RCD'd it, I prefer running chargers straight off a breaker as the charger has an RCD already - better selectivity and easier for the user to reset.
      Still a good install though, everyone does things differently! I liked your method of using the 10mm tails on the last video, I hadn't considered that but will be doing it from now on with standalone boards.

    • @alanbaltic
      @alanbaltic 3 месяца назад

      @@trojanhawrs4613 Please read and understand regulation 722.531.3
      A type A RCD should be fitted upstream of the charger regardless if there is an RCM device module built into the charger.

    • @trojanhawrs4613
      @trojanhawrs4613 3 месяца назад

      ​@@alanbalticThe Zappi has its own type A RCD so need not be fed by one. If the regulation stated that all circuits supplying a charge point had to have RCD protection, that would be different.

    • @alanbaltic
      @alanbaltic 3 месяца назад

      @@trojanhawrs4613 Hi Trojan, yes the regulation does stipulate this in amendment 2. If you speak to myenergi they themself will confirm that you will need to fit an RCD/RCBO upstream of the charger.
      Are RCDs required to supply a car charger?
      Yes, regulation 722.531.3 requires that an RCD (Max 30mA) supplies a car charger and the RCD shall disconnect all live conductors. This includes the Neutral therefore the single-pole RCBOs should not be used for this application. Amendment 2 also introduced the requirement to individually protect the car charger with an RCD so this RCD should not serve circuits in addition to the car charger
      Some car charger manufacturers quote an RDC-DD, what is this?
      An RDC-DD is a ‘Residual Direct Current - Detecting Device’. This is often built within the car charger equipment to monitor and if necessary disconnect should any DC problems appear on the AC side of the installation, which could affect the operation of RCDs
      If a car charger does not have any RDC-DD then what type of RCD is required?
      If the car charger does not have any RDC-DD then you will need a Type B RCD supplying the car charger. This is because Type B can detect this DC, still work and disconnect if required.
      What type of RCD should be used if the car charger has an RDC-DD that will detect and disconnect any DC issues above 6mA?
      In this case, a Type A RCD can be used. This is because Type A can still work correctly up to a level of 6mA DC. Over 6mA however, this Type-A device could be affected and possibly blinded and potentially stop working. This is the preferred option as Type A are now very common and lowest price. Therefore most car charger manufacturers have a 6mA RDC-DD built-in.
      Hope that helps.

  • @johnwarwick4105
    @johnwarwick4105 3 месяца назад

    Wouldn’t use that steel flexible conduit in that situation it will be rotted away in a few years. From experience has a very short life external. Can’t remember what it is called but you used to be able to get some really tough plastic copex type stuff. Super tough can’t cut it with a knife.

  • @Russell900
    @Russell900 3 месяца назад

    Whats the name of that cable? I've never seen 6sq power and data together before. I've only installed a Zappi with SWA and a Harvi monitor device so no need to wire the CT all the way to the charger but this looks like a great alternative.

    • @TheRCBiker
      @TheRCBiker 3 месяца назад +3

      It’s EV Ultra cable from Doncaster cables I believe

  • @ForTheBirbs
    @ForTheBirbs 4 месяца назад +9

    Arti.....who? Lol. Cheers Nick

  • @firsteerr
    @firsteerr 3 месяца назад +1

    you may have drilled better but did you use three tubes of silicone to glue it to the wall , all artisaned up in an afternoon

  • @AndyK.1
    @AndyK.1 3 месяца назад

    I think we said you should have moved the CU Nick 😂

  • @alexacb63
    @alexacb63 3 месяца назад

    I'm wondering which test, if any, would have shown the N/E reverse (or did you notice before testing), as assuming no upstream RCD from the one built in to the Zappi (so no trip there), on a PME system the Zs would have looked fine, and IR you'd likely have the charger disconnected anyway...

    • @NBundyElectrical
      @NBundyElectrical  3 месяца назад +1

      Mitch saw it before testing mate, god knows why they put the terminals in that order 🙃

    • @tonywatson1412
      @tonywatson1412 3 месяца назад

      Assume nothing.....like logic . for instance​@@NBundyElectrical

    • @tonywatson1412
      @tonywatson1412 3 месяца назад

      Ah.... assume nothing/ eg. Logic

  • @sward86
    @sward86 3 месяца назад +1

    Just a tip, as the EV Ultra cable has a data cable in it, and you only use one of the pairs as CTs, you can use another two pairs to make a 100 Mb data cable to hardwire the charger rather than using WiFi (provided the other end is close to the router)

    • @brightsparkmid
      @brightsparkmid 3 месяца назад

      We use 2 core data not the normal 4 pair

    • @sward86
      @sward86 3 месяца назад

      @brightsparkmid The data cable inside the EV Ultra cable has 4 pairs tho?

    • @brightsparkmid
      @brightsparkmid 3 месяца назад

      @@sward86 nah you can get one that has just one pair, it’s ev ultra high tuff

    • @sward86
      @sward86 3 месяца назад

      @brightsparkmid Orite, assumed it was the same stuff Artisan uses, which does have 4 pairs

    • @brightsparkmid
      @brightsparkmid 3 месяца назад

      Ye so Doncaster do a few variations of the cable, to reduce costs and be competitive we use the high tuff with a single pair inside, it all depends on what you actually need it to do I guess

  • @Cablesmith
    @Cablesmith 3 месяца назад

    Mitch is balling, clocked that 2k belcher on his wrist 👀

    • @NBundyElectrical
      @NBundyElectrical  3 месяца назад

      I had no idea. Might go missing if you’ve got a buyer 👀

    • @Cablesmith
      @Cablesmith 3 месяца назад

      @@NBundyElectrical you know me mate. I’ve got a buyer for absolutely anything 👌🏼😂

  • @neilpowell9312
    @neilpowell9312 3 месяца назад

    D-line clips? Much prefer the Linian clips for the Ev-ultra cable.

    • @brightsparkmid
      @brightsparkmid 3 месяца назад

      Same, as we both said, ideal for in wood etc where linians are not do great but much prefer the finished product with linian clips

  • @electricalservicesmaroc
    @electricalservicesmaroc 3 месяца назад

    Great 🎉🎉🎉🎉

  • @cluez3946
    @cluez3946 3 месяца назад

    these jobs must take so much longer when filming 😅

  • @user-nd8fq6ce3y
    @user-nd8fq6ce3y 3 месяца назад +1

    What laser you using. Mine never seems that bright

    • @brightsparkmid
      @brightsparkmid 3 месяца назад +1

      Nick had his DIY bosh green line one out, I used a professional Dewalt Green line, the Dewalt can seem dim when batteries are low

    • @user-nd8fq6ce3y
      @user-nd8fq6ce3y 3 месяца назад

      Thanks.

  • @thattoolguy9432
    @thattoolguy9432 3 месяца назад

    I remember that board move vid..the meter tails one really made me cringe... i coined the term "doing a bundy" on site ..youre still the flexicon king bud #Bundycon for 10% off

  • @johnmotson5063
    @johnmotson5063 3 месяца назад

    Nice beard where you get that from?

  • @11jeopardy11
    @11jeopardy11 3 месяца назад

    Using Bosch and DeWalt? I thought you were sparkies

  • @mrrobot9538
    @mrrobot9538 3 месяца назад

    least you don't need a laser level to drill straight lmao

  • @paulblundell8033
    @paulblundell8033 3 месяца назад

    But would Artisan wear safety glasses when drilling the brickwork when mounting the charger 🤔

    • @brightsparkmid
      @brightsparkmid 3 месяца назад +1

      Saftey squint for the win

    • @NBundyElectrical
      @NBundyElectrical  3 месяца назад +2

      Maybe if he was in the country

    • @paulblundell8033
      @paulblundell8033 3 месяца назад

      @@NBundyElectrical you were probably not able to wear anything after crying over the camera that fell over. You took that very well !
      His theme tune should be Holiday by Madonna 😁

  • @BustyMc69
    @BustyMc69 3 месяца назад +1

    Drilling is really hard too, well done lovely job. Not straight forward at all 👍🏼

  • @edglue6138
    @edglue6138 3 месяца назад

    Hydro

  • @svdleer
    @svdleer 3 месяца назад

    Frustrating that they did not put an extra conduit from the fuseboard, so ugly that the cables run over outside walls on a newbuilt.

    • @brightsparkmid
      @brightsparkmid 3 месяца назад

      Not much else we could do, I just don’t get why house builders are not installing a larger supply to garages for this reason

    • @svdleer
      @svdleer 3 месяца назад

      @@brightsparkmidYes i understand you have to do it what you have, but i just don't get builders (with newbuilds) don't think about one extra conduit if they are already laying one. Great video btw.

  • @user-mw6en2eq8p
    @user-mw6en2eq8p 3 месяца назад

    Personally cleats are neater and quicker given all of the fannying around.

    • @brightsparkmid
      @brightsparkmid 3 месяца назад

      Ye if we was in a factory where it’s common practise, personally I wouldn’t want a load of cleats attached to the side of my house, I see others do it and I think it looks like they have not got with the times.

  • @HAelec1
    @HAelec1 3 месяца назад

    There’s no depth stated in regs it’s down to engineering judgement. DNOs have requirements but not for us. Especially under slabs you’ve no issue there
    However the copex is a bit redundant as you haven’t earthed it so under fault conditions if the line conductor was shorting to the metal copex it wouldn’t trip. Just use SWA it would have been easier. I know it’s not your job so a bit difficult but still a good video and enjoyed watching it!
    And clearly you’re not happy about external CU and once again you clearly wouldn’t do it

  • @raymondburke1261
    @raymondburke1261 3 месяца назад

    Maybe adams mum should get a reward/ prise every time she’s mentioned in a video…chocolates or flowers maybe 🤷🏻‍♂️😉

  • @gctelectrical5555
    @gctelectrical5555 3 месяца назад

    Who's mitch?

  • @Jay369
    @Jay369 3 месяца назад

    Things Bundy does better than Artisan:
    Angle drilling
    Pricing
    Beard growing
    Adams mom jokes
    RUclips videos
    Rear entry
    ?
    ?
    ?

  • @pault4793
    @pault4793 3 месяца назад +1

    there is no regulation for 600mm deep

  • @ashleybignell2366
    @ashleybignell2366 3 месяца назад

    600mm deep is agricultural. Doesn’t apply to domestic, but must be deep enough not to be damaged through normal activity, shovel or tent pegs etc.

  • @anthonygray5581
    @anthonygray5581 3 месяца назад

    Ya loosing the plot nick😊😊

  • @Ant98986
    @Ant98986 3 месяца назад

    Adam’s got old

  • @MartinE63
    @MartinE63 3 месяца назад +1

    No problem with that cable run, the ends are clearly visible, the slabs are very suitable protection.
    At least you didn’t bury it less than 100mm in open ground, liable to be dug, with zero protection like tiles, just like another semi well known RUclips electrician did quite recently, and then when this was pointed out in a non-hostile way in the comments the spark claimed again it’s genuinely 600mm deep…despite very clear reference points like the house wall with standard size brick courses, a meter cupboard, and the 63mm duct itself in the very same footage.
    It’s embarrassing that rather than just say it was a mistake in the voiceover, or that the ground conditions didn’t allow it to be buried any deeper he just reiterated the 600mm line despite his own direct video evidence to the contrary, mindblowing attitude and it further erodes the low levels of trust the public has in many trades.

    • @jamiebourne8047
      @jamiebourne8047 3 месяца назад +1

      I thought it was way too shallow. Under a slab, I wouldn't go the full 600mm, probably 300-400 with marker tape about 100mm down. 600mm in a lawn though for sure👍

    • @NBundyElectrical
      @NBundyElectrical  3 месяца назад

      You got a link Martin ? I fancy having a look 👍

    • @timahad5165
      @timahad5165 3 месяца назад

      Who?

    • @tonywatson1412
      @tonywatson1412 3 месяца назад

      One doesn't like to point fingers ...at you tube sparkies.. BUT the bright spark in question, hadn't been seen for a while 😔

    • @TheRCBiker
      @TheRCBiker 3 месяца назад

      @@NBundyElectricalpossibly this one? ruclips.net/video/2Tk3zt9eDNg/видео.htmlsi=0QxmsUh1na__UtPD

  • @alimack5489
    @alimack5489 3 месяца назад +1

    Standard EV chargers customers who have double garages and can afford them. Along with the 50k car to go with it. Good job though mate 👍

    • @jvoric
      @jvoric 3 месяца назад +1

      What car(s) did they have ?

  • @brightsparkmid
    @brightsparkmid 3 месяца назад

    For all your angle 📐 drilling needs get in contact 😂 #brightbundydrilling