Ash handling system power plant dome valve dome seal pneumatic cylinder SOV live ash handling system

Поделиться
HTML-код
  • Опубликовано: 20 окт 2024
  • About this video
    Ash handling system
    power plant ash handling system
    pneumatic ash handling system
    power cylinder of ash handling system
    limit switch of ash handling system
    SOV of ash handling system
    pressure switch of ash handling system
    free ka gayan by dilipsahani
    If you want to know about any think about ash handling system you must need to watch this video at the end.
    also you can ask me if you have any doubts about ash handling system.
    I show you live working of ash handling system.
    if you want any other information about power plant or regarding this ash handling system must be comment in it I will try to give your answer as fast as possible.

Комментарии • 213

  • @ParmodKumar-tj8dm
    @ParmodKumar-tj8dm 3 года назад +1

    Aapke smjhane K trika bhut acha h Sir very thankful video aagye mere dost v daikhengye shaire kr diye h nc no contact kaise bnte h instrument level jaise K presser switch practically

  • @abhinav.rathore
    @abhinav.rathore 3 года назад +1

    Bhai aap ka video content mast hai...keep it up..aur v video banao.

  • @radha-k3d
    @radha-k3d 3 года назад +2

    Valuable work ...... impressive ❤️

  • @ayubansari9634
    @ayubansari9634 3 года назад +1

    Thankyou bahu अच्छा वीडियो h siR

  • @Amit4-Q-4
    @Amit4-Q-4 3 года назад +3

    Thanks sir for this information
    pressure switch ke connection aur kaise kaam karta hai btaye pls

    • @eidilipsahani6800
      @eidilipsahani6800  3 года назад

      Bhai pressure switch ke connection wo drawing se mil jayega and kam kaise karta hai wo same as other pressure switch karta hai woise hi hai woise me us pe bhi video banauga with practical application.

  • @sukhdevsharma4211
    @sukhdevsharma4211 3 года назад +1

    Jabardast mere bhai.....thank u 🙏🙏🙏🙏🙏🙏.....brother master and slave and different selection of mode.....kaise karte usape bhi video banaoo please

    • @eidilipsahani6800
      @eidilipsahani6800  3 года назад +1

      Sure buddy give me some time I will definitely make some videos on it.

  • @ParmodKumar-tj8dm
    @ParmodKumar-tj8dm 3 года назад +1

    Sir 1hi video h aapka jo sbse best h aur v bnaye sir instrument realated I'd fd pa

    • @eidilipsahani6800
      @eidilipsahani6800  3 года назад

      Thanks bhai plant Me kam jayada hai projects chal rahe hai time milte aur upload karta hu.

  • @tanveerrahmat5866
    @tanveerrahmat5866 3 года назад +1

    Nice work and congratulations for the channel nice informative video about APH.....keep it up👍👍👍

  • @kiniandaligang
    @kiniandaligang 5 месяцев назад

    Nice. Good job 👍

  • @AnkitSingh-ln8eg
    @AnkitSingh-ln8eg 3 года назад +1

    I think a good video for education purpose.👍

  • @RakeshKumar-yl3ff
    @RakeshKumar-yl3ff Месяц назад

    Very nice sir

  • @amirulislam7147
    @amirulislam7147 2 месяца назад

    Thank you so much

  • @ushachaudhary2294
    @ushachaudhary2294 3 года назад +1

    Good for knowledge

  • @akashnarlawar7461
    @akashnarlawar7461 3 года назад +1

    good information sir
    Ash handling system prr interview questions banao

    • @eidilipsahani6800
      @eidilipsahani6800  3 года назад

      No one can ask of it but if u want to prepare it's details like size and capacity which are mention in your manual

  • @souravde6322
    @souravde6322 9 месяцев назад

    Nice explanation

  • @sra1649
    @sra1649 3 года назад +1

    Nice explanation.

  • @jituchaudhary2516
    @jituchaudhary2516 3 года назад

    Achha video hai air banao👍

  • @officialdishant3226
    @officialdishant3226 3 года назад +1

    Good keep it up👍

  • @jaysoni4385
    @jaysoni4385 2 года назад

    Valuable knowledge ❤️sir

  • @pratushkumar5253
    @pratushkumar5253 3 года назад +1

    very nice keep continues 🙏

  • @sabirali-ts8ji
    @sabirali-ts8ji 3 года назад +1

    Please prepare vedios regarding supercritical boiler operations.
    Regards,

  • @lalitajit5252
    @lalitajit5252 3 года назад +1

    ESP ke d pump related video bhi Bana ke upload kariye.

  • @ahirsunil1914
    @ahirsunil1914 3 года назад +1

    Nice sir...

  • @koknisnehal7473
    @koknisnehal7473 3 года назад +1

    Plc ar dcs ka es system ka video bhi banaye

  • @pkentertainer4824
    @pkentertainer4824 3 года назад +1

    Very informative sir.
    Too too good.
    What should minimum pressure of seal and conveying in ash handeling system.

  • @RajnishKumar-tn7if
    @RajnishKumar-tn7if 2 года назад

    Thank you 💕😊💕

  • @Ram-sx5mv
    @Ram-sx5mv 3 года назад +1

    Mster slave p video bnao sr🙏🙏

  • @amankamble4689
    @amankamble4689 Год назад

    Thank you sir ❤

  • @abhishekrai6006
    @abhishekrai6006 Год назад

    Sir! We need more Videos....

    • @eidilipsahani6800
      @eidilipsahani6800  Год назад

      Thanks for the comment champ but due to work load i am not able to make a videos right now.

  • @VinodSingh-yw5rr
    @VinodSingh-yw5rr 10 месяцев назад

    Aph system me seal pressure gauge me so karne ke liye alag se sov lagane ki jarurat padati hai sir ji

    • @eidilipsahani6800
      @eidilipsahani6800  8 месяцев назад

      Already diya rehta hai gauge which I already discussed in my this video at panel area kindly visit and check out one more time

  • @sureshanna6686
    @sureshanna6686 3 года назад +1

    Nice

  • @rahulmeshram2212
    @rahulmeshram2212 3 года назад +1

    Nice sir

  • @Cricketing692
    @Cricketing692 Год назад

    Liw k bare me v bataiye

  • @dinabandhumahato6581
    @dinabandhumahato6581 2 года назад

    Control valve and mov ka vedio banaye sir please

  • @rahulprajapati9053
    @rahulprajapati9053 8 месяцев назад

    Sir please master or slave ke bare me bhi ak video bna dijaye

  • @Engineer24105
    @Engineer24105 2 года назад

    Thanks 🙏🙏🙏 bro

  • @suparintenar5265
    @suparintenar5265 3 года назад +1

    Nice video

    • @SanjayKumar-wi7lp
      @SanjayKumar-wi7lp 3 года назад +1

      Ser dom seal bar bar kat jata hai to kya karen

    • @eidilipsahani6800
      @eidilipsahani6800  3 года назад

      Cause kya hai wo pehle find out karo apka problems solve ho jayega

    • @VinodSingh-yw5rr
      @VinodSingh-yw5rr 3 года назад

      Sir Ji aap jo equipment lage hai use or details me video banaiye and uski jarurat kyo hai ye bataiye

  • @jainendragaikwad5295
    @jainendragaikwad5295 3 года назад +1

    Seal foult problem occurred frequently in my system pls suggest for 500mw unit

    • @eidilipsahani6800
      @eidilipsahani6800  3 года назад

      If you are provide some details like seal pressure set, dome is ok or it's created some edge?

  • @dancewithhimani7586
    @dancewithhimani7586 Год назад

    What is the reason if command goes to third field switch valve during second field conveying time.

    • @eidilipsahani6800
      @eidilipsahani6800  8 месяцев назад

      Must be check your plc or DCS connection and logics for this kind of issues

  • @akashasutkar6318
    @akashasutkar6318 3 года назад

    more information about ash handling ..

  • @ravinagar2367
    @ravinagar2367 2 года назад +1

    And one more question
    What is the difference between Instrument air and conveying air?
    (I mean that conveying ke liye instrument air ka use kyu ni karte hai?)

    • @eidilipsahani6800
      @eidilipsahani6800  2 года назад +1

      Instrument air ka cost badh jata hai because of dryer n all so we can't use in company our first priority to minimize the cost.

  • @yogishattri4590
    @yogishattri4590 3 года назад

    Stacker recklmer ke baare mein batayen

  • @SurprisedCake-ml2tq
    @SurprisedCake-ml2tq 9 месяцев назад

    Sir our basic knowledge

  • @kuwarkhandelwal3485
    @kuwarkhandelwal3485 2 года назад

    Vessel pressure bhi hota h ? Iske baare m btayiye

    • @eidilipsahani6800
      @eidilipsahani6800  2 года назад

      Ap sayad back pressure ke bare me bat kar rahe hai or seal pressure and conveying pressure hota hai ap thoda details me bataye to me ap ki kuchh help kar saku.

  • @worldinstrumentationengineer
    @worldinstrumentationengineer 2 года назад

    BAHUT ASSA VI
    MASTER SLAV KE BADI ME

  • @souravdey3878
    @souravdey3878 2 года назад

    Sir oo jo 3 pressure switch he, usme 1 seal pressure and 2 back pressure keliye he. So plz mujhe yeh bolia ki 2 pressure switch hum back pressure keliye q use karte he.

    • @eidilipsahani6800
      @eidilipsahani6800  2 года назад

      Kabhi kabhi system ko ye bhi pata hona chahiye ke conveying air pressure healthy hai ke nahi to uske liye ek aur pressure switch hai

  • @ramgurjar6124
    @ramgurjar6124 2 года назад

    Silo plant ki A to Z jankari bta do sar ji

  • @you-can-treading
    @you-can-treading 3 года назад

    sil pressure nahi aa raha hai sir... sab chek kar liya n sab sahi hai

  • @santoshkumarbareth5883
    @santoshkumarbareth5883 3 года назад

    Sir ji namaskr.. Ash handing start karte h to pahle preser kaun sa kholenge 1inch wala ya 1.5 inch presser plz clear me.. Ok

  • @bhuwansahu8470
    @bhuwansahu8470 2 года назад

    Sir meko ye achhe se janna hai I'm a instrument technician jayaswal Neco

  • @MANOJYADAV-oc8hr
    @MANOJYADAV-oc8hr 4 месяца назад

    Line change kaise karte h, aur image ke sath allpart ka name bataye

  • @ajaysharma-xz5kz
    @ajaysharma-xz5kz 3 года назад +1

    Sir limit switch kis company ka hai or wo only air se kaam kr raha hai kya

    • @eidilipsahani6800
      @eidilipsahani6800  3 года назад

      Bhai limit switch Duncan make hai and ha wo sirf air se kam kare wohi application ke liye hai yaha par.

  • @selva9637
    @selva9637 3 года назад +1

    👌

  • @surendragupta3564
    @surendragupta3564 2 года назад

    Dense Phase & Line Phase please explanation .

  • @birendranaik7618
    @birendranaik7618 Год назад

    Kese seal pressure check karte hain practicali bataie

    • @eidilipsahani6800
      @eidilipsahani6800  8 месяцев назад

      Ap gauge me dekhiye show karega seal pressure pls check in my video 😊

  • @bharatmali8002
    @bharatmali8002 2 года назад

    Sir ash handling system me air pressure ki puri cycle bataye ki air kaha se kaha jati he
    Aur panel me seal pressure nahi aata to kya kar na he

    • @eidilipsahani6800
      @eidilipsahani6800  2 года назад

      Sab to likhna possible nahi hai pur seal pressure na aye to direct pipe laga ke check kar lena chahiye ke air pressure utne bar ka hai ya nahi agar hai to dome seal replace kare agar nahi hai to air ko maintain kare

  • @matholiyatasvin37matholiya7
    @matholiyatasvin37matholiya7 3 года назад

    Hi sir
    Mera dome seal or dome dono fail huva tha mene new seal and dome install Kya fir bhi second day seal break ho gya to ape reason bata sakte he.
    Sytem dome seal pressure:-5.5 -6 kg/cm2 rahta he
    Minimize ke liye koy idea 💡 bata do

    • @eidilipsahani6800
      @eidilipsahani6800  3 года назад

      Use heavy duty dome seal i think your problems will solve

  • @santoshkumarmahto9973
    @santoshkumarmahto9973 3 года назад

    Ash handling & Esp ka detail..chahiyen with pratical sir....plz

    • @eidilipsahani6800
      @eidilipsahani6800  3 года назад

      Ash handling given by om engineering and esp by thermax

  • @VinodSingh-yw5rr
    @VinodSingh-yw5rr 10 месяцев назад

    Agar lagane ki jarurat ho to kaise laga sakte hai

  • @shivapathak66
    @shivapathak66 Год назад

    Full video banaiye na one by one

  • @ajaysharma-xz5kz
    @ajaysharma-xz5kz 3 года назад +1

    Sir 5/2 sov to double acting valve ke liye hai na fir aapne q single acting bola

  • @NIRMALSINGH-dw8dm
    @NIRMALSINGH-dw8dm 3 года назад

    Bhai isko ek ek cheej ko aur jyada elaborate karke batiye....aur Kya Kya problem aati hai aur u he rectify kaise karte hai plz

    • @eidilipsahani6800
      @eidilipsahani6800  3 года назад

      Ap ko jo bhi problem ati ho ap muje batao i will definitely try to solve your problems

    • @NIRMALSINGH-dw8dm
      @NIRMALSINGH-dw8dm 3 года назад

      @@eidilipsahani6800
      Sir
      1-Seal pressure, back pressure,aur conveying pressure Kya hote
      2- pressure switch se kiska kiska signal jaata hai PLC ko
      Aur PLC kisko kisko signal bhejti hai kis sequence me
      Plz ache se bataaye
      If it's possible then solve these problem through a video

    • @eidilipsahani6800
      @eidilipsahani6800  3 года назад

      1 seal pressure it is for sealing the dome valve
      2 Back pressure it is created when conveying line is jammed
      3 conveying pressure it is for conveying the ash from vessel to sylo
      4 ash handling plant working process.
      .Seal pressure is healthy then it's timmer will continue and operate the dome after that conveying is done and if line is jammed than back pressure form. In which total 2 sov and 3 pressure switches are use. Which I already told in this video also in this also you will get which singnal comming from PLC and to PLC.
      If you not getting then free to ask

  • @sachindixit4018
    @sachindixit4018 Год назад

    some times cylinder not operate properly( if it slightly t up manually then it open or close)
    What would reason?

    • @eidilipsahani6800
      @eidilipsahani6800  Год назад

      Check cylinder alignment

    • @sachindixit4018
      @sachindixit4018 Год назад

      Same wording used by ele.dept.but I thought there pressure issue(not proper pressure to cylinder )

    • @eidilipsahani6800
      @eidilipsahani6800  Год назад

      Pls explain all the issues if any parameters are abnormal etc so i can explain you mr dixit

    • @sachindixit4018
      @sachindixit4018 Год назад

      Primafaice issue that cylinder not operate but after electrical rectified it working normal so I want to know from mechanical point of view, because generally electrical blame to mechanical dept.that cylinder is faulty etc, seal pressure 3.8kg , dome and cylinder proper alignment

    • @eidilipsahani6800
      @eidilipsahani6800  Год назад +1

      There is no mechanical things i think im also from electrical instrumentation i can do all the things no need of mechanical in pneumatic systems

  • @ManojSahu-w9g
    @ManojSahu-w9g Месяц назад

    Plc me sys chal raha hai but field nahi chal raha problem solve please ji

  • @rahulprajapati9053
    @rahulprajapati9053 9 месяцев назад

    Sir isme kabhi pressure switch or sov kam nhi kr rhi he to kase check kare please reply me sir

    • @eidilipsahani6800
      @eidilipsahani6800  8 месяцев назад

      Agar pressure switch kam nahi jarega tab ap ka system healthy nahi batayega kyo ki no nc signal nahi milega and sov nahi kam kiya to ap ka system like power cylinder operate nahi hoga so ap easily identify kar sakte hai

  • @lokeshverma3674
    @lokeshverma3674 Год назад

    Coil ka cnecosion rile me kyse krte hai

  • @prameshpadhan1638
    @prameshpadhan1638 3 года назад +1

    Sir dome seal kaise change karte hai

    • @eidilipsahani6800
      @eidilipsahani6800  3 года назад

      Next time jab seal change hoga i will make practical video on it for you buddy

  • @nathramjangde4034
    @nathramjangde4034 3 года назад +1

    Dom sill katne ka karan kya hai

    • @eidilipsahani6800
      @eidilipsahani6800  3 года назад

      Air pressure bhi ho sakta hai
      Dome ka bhi isse ho sakta hai
      Normal operations ke badh wo thick ho jata hai wo bhi ho sakta hai
      Ap ko pehle wo pata karna padega

  • @santoshkumarmahto9973
    @santoshkumarmahto9973 3 года назад

    Seal pressure.
    Healthy nhi hoga to kya nuksan hoga

  • @rajeshgarai2868
    @rajeshgarai2868 3 года назад +1

    Ballo Ka Kam Kaya Ha

    • @eidilipsahani6800
      @eidilipsahani6800  3 года назад

      Due to temperature line get expand so it will help and save the system

  • @sonulodha6324
    @sonulodha6324 2 года назад

    Sir plc control system samjaeye

  • @biswaranjanmohanty4996
    @biswaranjanmohanty4996 2 года назад

    What are the reason for continuosly dome valve seal and o ring damage

    • @eidilipsahani6800
      @eidilipsahani6800  2 года назад

      It's may be poor quality of dome seal you got or may be your seal pressure is not maintain or may be your seal pressure is lower then conveying pressure there is many reasons bro

  • @NayanPatil-vm3sq
    @NayanPatil-vm3sq Год назад

    Dome value not convingline solution?

    • @eidilipsahani6800
      @eidilipsahani6800  8 месяцев назад

      Kindly elaborate your issue so i can understand and give the solution pls

  • @sudhanshukumarsingh6267
    @sudhanshukumarsingh6267 2 года назад

    Sir c&i ka kya kam hai ash handling me kripya kar ke mujhe bataiye

  • @rohitkumar-zn1oe
    @rohitkumar-zn1oe Год назад

    Kis material ka hai plz name bhi btaiye

  • @sajedursojib453
    @sajedursojib453 3 года назад

    What is the purpose of this seal air? Why we have to maintain this pressure pls clarify?

    • @eidilipsahani6800
      @eidilipsahani6800  3 года назад

      Buddy I think you are need to study about this and if after that you have any Doubts you must be ask me.

    • @sajedursojib453
      @sajedursojib453 3 года назад

      @@eidilipsahani6800 ok. What is the purpose of ash vessel booster assembly pls clarify?

    • @eidilipsahani6800
      @eidilipsahani6800  3 года назад

      Are you working on it???

    • @sajedursojib453
      @sajedursojib453 3 года назад

      @@eidilipsahani6800 yes.

    • @eidilipsahani6800
      @eidilipsahani6800  3 года назад

      @@sajedursojib453 then why are you asking for purpose I think you better know that is it's use for and if you are facing any issue then I will give you suggestion buddy so must be reffer manual for its purpose

  • @Vijaykumar-zg2nz
    @Vijaykumar-zg2nz 3 года назад

    2 we on of valve se pressure drope ho rha hai kya kre sir plz

  • @nagbhushanbhushan8682
    @nagbhushanbhushan8682 3 года назад

    How to find it seal got damaged

    • @eidilipsahani6800
      @eidilipsahani6800  3 года назад

      Compare with input air pressure and seal pressure if it is below then you can get it it's seal are damaged simple

  • @avadheshshah8900
    @avadheshshah8900 2 года назад

    master and slave d pump ke bare share please

  • @rohitsingh-hh3vp
    @rohitsingh-hh3vp 11 месяцев назад

    Vessel pressure high h to kya matlb

    • @eidilipsahani6800
      @eidilipsahani6800  8 месяцев назад

      Vessel pressure high hone ka reason ash conveying line chocking hota hai so need to flush your ash conveying line and make back pressure less then 0.5 bar

  • @surajyadav-nk2zm
    @surajyadav-nk2zm 2 года назад

    Sir mujhe pressure switch ke bare me janna hai

  • @ParmodKumar-tj8dm
    @ParmodKumar-tj8dm 3 года назад

    Iska connection jo dcs aaya h o btaye

    • @eidilipsahani6800
      @eidilipsahani6800  3 года назад

      Mere yaha seperate PLC panel hai so i can't show you dcs connection but both are same there are IO and you have to select chanel and io in dcs also need to create logics in programing for ash handling system.

  • @rameshpaigwar2707
    @rameshpaigwar2707 2 года назад

    Sir mere ko pura tubing bataye ki kaise kare

    • @eidilipsahani6800
      @eidilipsahani6800  2 года назад

      Tubes ke bare me janna hai to ap ko uski manual padhni chahiye fir bhi na samjhe to ap mujse puchho me ap ko bataunga

  • @krushnathpatankar6079
    @krushnathpatankar6079 3 года назад

    ऐश हांडलींग के कितने प्रकार होते है

  • @ravinagar2367
    @ravinagar2367 2 года назад

    Sir can u tell me that why does we speak master vessel to master? I mean master vessel ko master hi kyo bolte hai, aisa konse components hote hai ya aisa konsa design hota hai uska? Please tell me in detail.

    • @eidilipsahani6800
      @eidilipsahani6800  2 года назад

      Time milte hi master and slave pe video banauga bhai

  • @ravinaik4085
    @ravinaik4085 2 года назад

    Sir inst and service airline connection explain in esp line

    • @eidilipsahani6800
      @eidilipsahani6800  2 года назад

      For seal pressure used instrument air and for conveying we used service air

  • @विनोदचौहान-म1फ

    Mastr dom ketne prkar ke fart rhte hi

  • @RajnishKumar-tn7if
    @RajnishKumar-tn7if 2 года назад

    Sir

  • @Rameshkumar-qy2wh
    @Rameshkumar-qy2wh 2 года назад

    Ash handling yer Pressure kya hona

    • @eidilipsahani6800
      @eidilipsahani6800  2 года назад

      Tum ko kiska air pressure hona instrument air or conveying air pressure

  • @MrRee-mt3gp
    @MrRee-mt3gp 2 года назад

    Poppet vavle dismental Kar k Ripering and full name pepper vavle pats

  • @akashasutkar6318
    @akashasutkar6318 3 года назад

    seal pre.is not showing healthy then which types of prb.are created ..nd that time hows chek seal pre.

    • @eidilipsahani6800
      @eidilipsahani6800  3 года назад

      Already told in comment if it is not healthy then too system are running then its dome n its assembly may get damage and you can Easley check ok gauge

  • @nirmalruidas3243
    @nirmalruidas3243 2 года назад

    Sir hamara system PE roj sil likes hojarahahe

    • @eidilipsahani6800
      @eidilipsahani6800  2 года назад

      Seal pressure and conveying pressure kitna hai and seal konsa use kar rahe ho?

  • @birjbhushansharma1347
    @birjbhushansharma1347 Год назад

    SUV Mein oil a raha hai air filter se

  • @ameersohail456shaik2
    @ameersohail456shaik2 2 года назад

    Plz tell mi Master Slave operation

  • @sukhendughara2533
    @sukhendughara2533 5 месяцев назад

    AAP ka awaz sahi Nehi hai

  • @madansidar9346
    @madansidar9346 2 года назад

    PS 1 PS2 PS3 ka matalab kya hai

  • @starngeer12345
    @starngeer12345 3 года назад

    2:55😢cylinder close hai aur aap usko open bol rahe ho ,3:00 mai open huwa hai toh aap close bata rahe ho

  • @potipireddynaidu1272
    @potipireddynaidu1272 Год назад

    Voice quality not good

    • @eidilipsahani6800
      @eidilipsahani6800  8 месяцев назад

      If you working in power plant this much noise are present all the time and i was make this video live so voice quality not maintained that time but thanks for your observation i will take care for next video

  • @rohitmaurya3590
    @rohitmaurya3590 2 года назад

    Bar bar Dom sil fat Raha he

    • @eidilipsahani6800
      @eidilipsahani6800  2 года назад

      Neoprene ka lo nahi fatega and also maintain your all parameters

    • @eidilipsahani6800
      @eidilipsahani6800  2 года назад

      Neoprene ka lo nahi fatega and also maintain your all parameters

  • @mouneshb8278
    @mouneshb8278 11 месяцев назад

    App ka cantact number dedo. Pls

    • @eidilipsahani6800
      @eidilipsahani6800  8 месяцев назад

      Koi issue ho ap comments kare i will try to solve you problem