G120P Siemens drive Hindi, Siemens g120 drive hindi
HTML-код
- Опубликовано: 7 сен 2024
- आप सभी Viewers और सब्सक्राइबर का तहे दिल से स्वागत है @Dharmendragiri21
आप सभी अब इसी तरह अपना प्यार और सहयोग हम पर बनाए रखें
एक बार फिर से आप सभी का धन्यवाद!
प्लीज एक बार इस प्लेलिस्ट को जरूर चेक करें
• Life In UAE
आप लोग हमसे फेसबुक इंस्टाग्राम के द्वारा भी जुड़ सकते हैं जिन के लिंक नीचे दिए गए हैं
Facebook :- / 100002593928639
Instagram :- / dharmendra_giri__
Good information
Nice video Sir. Please explain in practically with the motor. Thanks
Sir S120 drive ka upload & download & Auyo tuning par complete video banaye Sir with laptop
here i got full knowledge of Siemens drive 👍👍👍
well said !
Sir S120 Auto Tuning par bhi video banayiye with laptop
Thx
Sir S120 Auto tuning par bhi video banayiye Sir mai besabri se intezaar kar rha hu
Nice explaination
First thing i will appreciate that your display is bright so people can see .. thanks ..
Sir ID run ( Auto Tuning) par bhi video banayiyega please 🙏 with laptop 💻 🙏.
Wow
Very nice best in u tube .. thanks .
You take care of viewers requirement
good sir aise hi video or banate rho
thanks
👍 thanks
Good job sir
Vip
thank u sir
Dear Sir
G120 Drive Current is Fluctuations.
So we Checked Motor Found Okay and Motor Replacement also done but same Fluctuations.
So we replaced Drive and Checked Found Same Fluctuations.
And drive Input and output chokes Replaced same Fluctuations.
After this all replacement only one common Issue Current Fluctuations.
Motor Rating 75 KW
Full Load Current 131 Amps.
So kindly request you please suggest me as soon as possible.
In drive what I need to be Checked?
good learning vedio sir. !!
make a vedio for copy parameters
Good knowledge you are sharing.I need to replace drive.I copied parameters by bop and after replacing drive again transfer the par from bop to drive.ready sign is green but its showing bf red.how i can set profibus address or i have to set as you shown by setup procedure.
sir eska manual ki ek Video banao
Sir Do/Do and Ai/Ao kaise assign krte h drive parameters me like p840
Uska ek video bnaao yaa btaa do masg through
G120c drive
Old setting Dekh Nahi sakte kya
Bhai Sahab Siemens single motor module aur double motor module kaise work krti hai ....vedio bnaiye plz
6ra80 dc drive ke bare me btaye sir
Plz make a vdo about relay operating parameters of g120 vfd's
Dear Sir
Drive is Started but Drive Output Voltage is 0 And Current Also 0 Amps .
What is the reason for this Issue ?
Remote control wiring kese karte hai
S120 commissioning kaise karna hai share kijiye. For servo motor(ball screw)
Please sir link for communication software.
Hi .sir thanks for video...
I have one drive same but the parameter meaby delete..
We have memory card.. how we can to agine to put parameter from memory card to drive..
?
Thanks
En español
How to check . Tuning is failed
G120 drive for this drive which motors used also please provide technical details
Sir f7800 error why it came, how to solve the issue
How to change Motor Rotation from Control Unit?
The voltage near the drive is 395 and the motor has 435 in between 200 and 200.
Dear sir, Siemens Micromaster 440 75KW.(Box size F)
BOP display does not come after input line (L1,L2&L3) 400 volt AC?
please help me.
Sinamic power module 240 not running while no fault
Siemens micromaster 440 (75kw) that run is possible without profibus ?
Yes it can run without Profibus
sir muje gs120 drive digital input se fwd rev and multi speed chlne ki liye parameter
how to run with two speed and forward rivers
How to take backup of parameters in BOP before reset
No need to take backup, u can understand all parameter and why they require
Sar aapka nabro milsktaa ha
Hello sir G120C 132 kw me motor heat ho ra hai input voltage 416 vfd Ka out put voltage 275 input ampare 6 output ampare 95 open load hai load me input ampare 95 output ampare 143 drive our motor Dono heat ho ra ha hai 4se 5 hour me trip kar band ho ra hai
I have g 120- 250 cu-s drive pls tell inpit parameter their
Sir DI DO AI AO KA PARAMETER BATAO AUR HAME 2 PLACE SE
CONTROL KARNA HAI DI AUR AI SE
Sir motor seating keshka karta ha
I am getting red led indication drive not ready and BF what to do in G120P vfd
BF means bus fault, may be some problems in communication
Can you able to run drive hand mode
Parameter available hai
Sir
How I get vfd trip indication from vfd
Dear sir, Siemens Micromaster 440 75KW.(Box size F)
Supply voltage 400 then BOP display doted line blinking (- - - - - ).
But display parameter not showing?
please help me.
May be bop not connected properly or faulty
This BOP display .75kw/1HP inverter connicting time ok.
But 75kw inverter connecting time BOP display doted line blinking (- - - - - ).
mosharof hossen
Can you sand me pictures
Dharmendragiri21@gmail.com
sir incodar bypass paramitar kya he
Sinamics drive me jab power on/ off hone k bad p10 =1 change kyo ho jata h
Aap hindi me vidio banao incodar seting incodar baypass paramitar kya he
F7800 led is red wats the problem
Drive not ready
sir Drive mai fault dikha raha hai 30027 rdy light billing kar rahi hi pls help me
Why not turn on Hand Mode?
Sir please share me programing manual vfd
Sir can I talk to you
Reverse kaise karte DI 1 SE
pls explain parameters
when i release the push button g120 drive gets off
Plz help me
200 MTR ka different hai
bekar drive hai danfoss is better
Good job sir