Sir ap engineers k liye video banate hai ya aam admi k lie?? Imp jaga skip karke ja rahe hai ...Hum fresher engineers apka channel dekke sikhte hai lekin ap to important jaga skip karke ja rahe hai
hello ser. ser ager hamara 3 site par ollradi bana hoa ho to ager ham apna plot ka fondition ka colum sainter Mai rakha ya sait ma barber wala pilot sai mila ka .?
अगर bedrock जमीन है, यानी पूरी तरह चट्टानों वाली जमीन पर किस तरह से फुटिंग,प्लिंथ ,बीम कॉलम बनाने हैं इस पर शार्ट में जवाब दीजिए,, क्योकि मुझे ऐसी जमीन पर फेक्ट्री ओर घर का कंस्ट्रक्शन करनी है
9/12 inches sahi rahega kya sir 3 story ke liye???i provided 10/12 inches but i have read that as per IS code the coloumn size should be 1 ft by 1 ft.so confused hu sir
Sirji, Hamne 2010 mai Ghar banaya Ground + 3 floor, Building me dikkat ye hay ki Bajuwale ki diwar aur hamare building ki diwar ke bich dhire dhire gap badh rahay hay to iska solution kya hoga.. Please guide kijiye aur solution bataiye..
Hi... I need some suggestion for the construction of my house... My house is half constructed and at the front side we have 4 rooms including slab everything is done and in the back side foundation is done for another 4 rooms.. But i want to increase the height in back side... Becz road level got higher and in future there will be problem... Wat you think about this
Hello sir, you said that the height of cuboid should not be less than 150mm/6inch, how can we determine the heights of cuboid and truncated-pyramid of the trapezoidal footing in different storey buildings, specifically for 5 storey building with footing of l x b x depth = 7' x 7' x 7.5' ? thank u :)
Why halve the sbc? It's already a fraction of UBC and it's safe to assume and as far 10 percent increase for column load is not necessary as service loads are already 1.5 times the working load. Rest is all good.
Bahut acha explain kya. Sir aup ke sath learning karna ka maja kuch alag hai. 😅
Sir ap engineers k liye video banate hai ya aam admi k lie??
Imp jaga skip karke ja rahe hai ...Hum fresher engineers apka channel dekke sikhte hai lekin ap to important jaga skip karke ja rahe hai
Footing Area kam karke depth increase kar sakte hai kya? Aur column bhi 9" x 14" le sakte hai kya
Sahi sahi jankari di
sir trapezoidal footing ki dimensions par video banao jo 4 storey building ki ho
Nice im from Nepal
Very nice information sir.
hello ser. ser ager hamara 3 site par ollradi bana hoa ho to ager ham apna plot ka fondition ka colum sainter Mai rakha ya sait ma barber wala pilot sai mila ka .?
Try to explain always with example of the site. It is just like tuition class
Very useful video for Freshers...🤝
Sir exposed ground k liye footing suggest kar dijiye
Love u from Pakistan.
Very informative Video Sir...🙏🙏🙏
Sir solitude education ka packege 45 days wala kaisa hai
Sir axieal load 1200 kiu ..assume karna Chahiye usse vi Jada ya kaam nhe Kar sakte kya
Neck column ke liye bituman ka use karna chaiye.
Moisture se bachane ke liye.
Aap aise hi fill karwa rahe ho.
Sir column ke starting se brick work kare ya 3feet upper se kare
Maja aa gaya dekhne main sir...thank you so much sir
G+ 2 k liye depth 9 ft rakhi hai, Pune mein ghar bana rahe hai,rock land hai,ye sahi hai? Please bataye 🙏
Sir ji 3 storey house ke liye agar 9*12 ka colom diya gaya hi to floor beam ka kya size dena hi thumb rule ke hisab se
अगर bedrock जमीन है, यानी पूरी तरह चट्टानों वाली जमीन पर किस तरह से फुटिंग,प्लिंथ ,बीम कॉलम बनाने हैं इस पर शार्ट में जवाब दीजिए,, क्योकि मुझे ऐसी जमीन पर फेक्ट्री ओर घर का कंस्ट्रक्शन करनी है
Hard gamin hai 3fit se 4fit tak 5story bana sakte hai kya sar 9y15 9y12 colam sige sahi hai kya sar
two story ky liyh column ka ka steel center m 16mm ky 2 or corner py 12 mm rakh sakty hi
VERY GOOD SIR JI.
nice video sir from Nepal jay nepal jay hind sir
Thank you bro...
Nice information.,
Sir footing me main bar kha rkhna h longar span par ya shotar span par
Super sir👍👍👍👍👍
Three story building ko aur upar banane ka plan hai . Foundation kaise restrength kare ? Pls bata an.
ye 1200kn kaha se aaya, ye to theoratical concept lagra actual laoad on footing kaise nikale
घर बनाने हेतु 30×50 साइज़
कितने काॅलम बनाने चाहिए
एक कालम में कितना खर्चा आएगा
इसकी जानकारी हो तो बताओ सर
Hiii
Civil site visit.
Why we provide ' L' on Footing Mat.
Sir hamara Ghar 6 Marla mein hai gali 4 feet rasta hai purne makaan ko kaise renovate karen.kuch Samajh nhi aa raha hai pl guide karen.
Beautiful place
Thanks 👍
How Arch can decide the depth of footing, it is purely depends on soil condition and it Bearing capacity
Sir 06 manjil ka video banaye
Sir I want a job civil .👷♂️
Civil guruji ka palana kuch costly lag raha as compare to solitude education se
Aapne solitude education ka ya civil guruji ka course liya hai ?
Bhai lootne ka tarika h Guru ji ka
Lu le
@@shariquejamal82, ,
Civil guruji is worst channel
I prefer this channel coz most of faculty of civil guruji has very shallow or less knowledge than this guy
Aaj kal Trapezoidal footing hi dete hai har jagah agr g+3 building hai toh
Thanks to you it's very helpful
Sir mera ghar aak manjila hai flight footing diya hai aage koi dikkt to nhi aayegi sir
9/12 inches sahi rahega kya sir 3 story ke liye???i provided 10/12 inches but i have read that as per IS code the coloumn size should be 1 ft by 1 ft.so confused hu sir
Where is the link for soil bearing capacity video
Can v contruct house on single column i.e. 500 sq.yds. Single or double story
Thank you Sir
Beautiful vediio
thank you
Awesome
Plot k edge par footing kese design karte hai .??????
Aisa video chaiye sir
I see some stripus in column
There is no provide hook in 135 deegee
Saath me hi pcc b bta dete mesh k niche BTW thanx
Brother load kaise consider kiya
Sir Make a video for size of a beam
Sir screen shot Leno ko mauka dijiyega please sir❤️❤️
Column me 6 nos. Of 12 mm rod laga sakte hein kya...
Steped footing me size kiya hoti hai aur de sakte he kiya
How to calculate the load?
Trapezoidal footing ka volume kyasy nikaley
Footing size kitna by kitna long or widh khodenge samaj nahi paye sir
kitni storey
hai
area kitna hai
ruclips.net/video/4Poc8glgHx4/видео.html
ruclips.net/video/hfLhPPdCHe8/видео.html
Thank you so much sir.
Bhai load 3 storey ka calculate kaise karein wo batana - 1200 KN KAHA SE AAYA 😅
Sir..dead and live load kaise nikalen..
Sir 9"×9" column mai konsa dia mm use karnese best hai ak slab ka ghar hai. ak column mai kittana kharash ayega please batadijie ?
12
Bhai apne calculate karke dikhani chahiye na ki approx 5- 6 "" feet directly nahi kehna tha 😅
How to calculate load on footing?
Load of total building/ number of column,, or total footing area
Sirji, Hamne 2010 mai Ghar banaya Ground + 3 floor, Building me dikkat ye hay ki Bajuwale ki diwar aur hamare building ki diwar ke bich dhire dhire gap badh rahay hay to iska solution kya hoga.. Please guide kijiye aur solution bataiye..
Sir contractor ka Kam Karna Hai , Kaise kare
Hi... I need some suggestion for the construction of my house... My house is half constructed and at the front side we have 4 rooms including slab everything is done and in the back side foundation is done for another 4 rooms.. But i want to increase the height in back side... Becz road level got higher and in future there will be problem... Wat you think about this
बांधकामात स्टील ऐवजी बांबू वापरणं योग्य आहे का?
वापरा.
Give me your zone video link ??
10 fut tak kali mitti ho to kya kre.
How much nos of cloum
Gross area ka matlab ??
अपने पेन से बड़े बड़े अक्षर लिखे हैं जिससे साफ दिखाई दे .वीडियो छोटा बनाया और धीरे-धीरे समझा कर बताएं .
Bhai engineer no to 16 k 4 hi enough he
Or middle me 16 k 6
Load kaise pata chalega yah batao pahle???
tq
sir 6sq.m = 2 * 3 size le sakte hai kya footing me.
Ha
Is the Height H1 and H2 which is 150mm and 450mm irrespective depth of the Footing will be same or it varies?
कमरे के कोने मे कोलम देखाई देता है किया बाहर किया जा सकता है
Ok sir
Ek aacha pen lena chahiye tha.
सर फुट या इंच में बताया करो , अब ये बताएं कि 2.449 *2.449 मीटर कितना फुट होगा ?🙄
8 ft
Jamin ke niche
m25 concrete ratio or 8mm 12mm dia me 3rd floor building taiyar hoti hai sare builder yahi kar rahe hai ye galt hai
plz sir tell in feet or inch
Hello sir, you said that the height of cuboid should not be less than 150mm/6inch, how can we determine the heights of cuboid and truncated-pyramid of the trapezoidal footing in different storey buildings, specifically for 5 storey building with footing of l x b x depth = 7' x 7' x 7.5' ? thank u :)
Is design se bane hue column se kya padoshi ke ghar me ghus kar foundation banaoge
M30 grade is very much over design. Very costly project.
Why halve the sbc? It's already a fraction of UBC and it's safe to assume and as far 10 percent increase for column load is not necessary as service loads are already 1.5 times the working load. Rest is all good.
Load kese pata chlega
Sir help me plz plzzz
Sir, 2.449 meters means 8 feets for footing, is it correct
3 storey ka mtlb G+3 hota h?
G+2
plz tell in fit
Wrong method .
It is used for short column
3:58 🤣🤣150 mm hota hai 6 inch
Yeh eise yeh eiseh isko hogia. Yeh bi eiseh yeh eise isko bi hogia nikalgia dekho. Ghar eiseh nikalgia dekho. Yeh Eiseh andar jata ghar me dekho hogia ghar. Mera brain tissue merako yeh eise gali dia. Hum eiseh faint hogia.😂😂