Femoral Artery Doppler Ultrasound Normal Vs Abnormal | Stenosis/Occlusion/Pseudoaneurysm/AVF USG
HTML-код
- Опубликовано: 7 июл 2024
- Femoral Artery Doppler Ultrasound Normal Vs Abnormal | Stenosis/Occlusion/Pseudoaneurysm/AVF USG
*Timestamps
Intro - 0:00
Normal Common Femoral Artery/Superficial & Deep Femoral Arteries - 0:08
Femoral Artery Stenosis (less than 50%) - 1:28
Superficial Femoral Artery Stenosis - 2:33
Femoral Artery Stenosis (greater than 70%) - 4:40
Femoral Artery Occlusion - 5:43
Femoral Artery Chronic Occlusion - 6:03
Femoral Artery Pseudoaneurysm - 6:23
Arteriovenous Fistula - 7:34
Related: color, spectral, yin yang sign, waveform, tardus parvus, imaging, images, cases, scans, radiology, diseases, vascular, ultrasonography, sonography, medical
Watch More Ultrasound Videos:
Gynecological Ultrasound: ruclips.net/p/PL4cRFWfjMmf-J4vhXPWZbx5uRIwq77EBd
Obstetric Ultrasound: ruclips.net/p/PL4cRFWfjMmf-M-IH-Bq-LY-07LeEFdi5T
Abdominal Ultrasound: ruclips.net/p/PL4cRFWfjMmf_8Rxbgv4Ru77mxhAE9mN2L
All Videos: : ruclips.net/p/PL4cRFWfjMmf_P02uIGRTFiYNozGKuILAX
Thank you Dr..Sam...for nice presentation..
Most Welcome!
0:36 TRIPHASIC FLOW, HIGH RESISTANCE FLOW 1:31 FEMORAL ARTERY STENOSIS 1:55 BIPHASIC FLOW 2:34 SUPERFICIAL FEMORAL ARTERY STENOSIS 4:10 TARDUS PARVUS WAFEFORM 4:38 CRITERIA FOR MORE THAN 70 % STENOSIS 6:47 PSEUDOANEURYSM 6:58 YIN YANG PATTERN 7:33 ARTERIOVENOUS FISTULA
Thank you dr Sam so much
Most Welcome!
Hello, dr. Sam, again from Romania. Please, show us a little bit vascular anatomy of the lower limb. I'm also interested in the carotidian index intimate-medium. Thank you very much.
Thank you so much for watching! Yes, it will be uploaded in the future.
Thank you so much,🙏👍
Most Welcome!
This video is informative. Thanks
Most Welcome and Thanks for watching!
So nice,thanks a lot
Most Welcome and thanks for watching!
Please upload more vascular USG videos anatomy and pathology ! 👍
Thanks for watching! Yes, more videos will be uploaded in the future!
Thanks alot ..
Most Welcome!
Thank you sir
Most Welcome!
thanks
Welcome!
Thank you dr sam videos are amazing helping me a lot after vascular can you upload msk videos and neonatal brain usg
Thank you so much for watching! Yes, they will be uploaded in the future!
Best..sir plz upload popliteal n ant tibial n post tibial and peroneal n dorsalis pedis artery ...normal n abnormal....how to start Doppler arterial in lower limb techniques....
Thank you so much for watching! Yes, they will be uploaded in the future.
Mister Sam why the color box in the Lt image towards the head and in the Rt image is towards the feets? Please explain to us this point
It is done to keep the doppler angle away from being perpendicular to the vessel. It does not matter whether the color box is directed towards the head or feet. That is random. We just need a sufficient doppler angle (60/45 degrees) to evaluate blood flow.
Hello doctor please do make one probe orientation vdo on lower limb Doppler if it's possible .
Yes, it will be uploaded in the future. Thanks for watching!
Common femoral artery:
Peak Systolic Velocity - what is a good number with triphasic flow
Generally, PSV below 100cm/s is considered normal with triphasic flow
thanks sir
Most Welcome!