Av worked with Avs 30 and men this thing can save you big time wen it comes to electonic repairs caused by spikes,surges etc and mark you the gadget is not that expensive compaired to changing ur motherboard of ur Android tv or fridge compressor,thanks bro continue teaching us💪
Nice content, thank you for this. I have a question, i have been using my AVS, but recently i had to relocate it to another house, after connecting it, i discovered that it simply comes on anytime the power is on, it doesn't stop the power with the timer as it did in the past. Please what could be the problem?
Does it reduce the voltage when it's too high? Am having a constant high voltage of 300 which burns my appliances. I need what will step the voltage down to 220volts
we have a pump which was set on 220v which warns under and over voltage and our power is fluctuating 220-251v so will that avs produce strictly 220 as out put thanks
NO......If your power is available but fluctuates quite often then what you need is A STABILIZER... it will give you the same value whether the voltage is high or low. What AVS does protects your circuit by switching it off if power fluctuate BELOW or HIGH value that you set in the Device.
Awesome content,was looking for the next video on how to connect the 3phase AVS with the contactor
Av worked with Avs 30 and men this thing can save you big time wen it comes to electonic repairs caused by spikes,surges etc and mark you the gadget is not that expensive compaired to changing ur motherboard of ur Android tv or fridge compressor,thanks bro continue teaching us💪
Nice content, thank you for this. I have a question, i have been using my AVS, but recently i had to relocate it to another house, after connecting it, i discovered that it simply comes on anytime the power is on, it doesn't stop the power with the timer as it did in the past. Please what could be the problem?
A very informative video😮
Very educative video,thanks alot
Bro you have helped me alot
Am glad your helped........and thanks for watching
Great job
Does it reduce the voltage when it's too high? Am having a constant high voltage of 300 which burns my appliances. I need what will step the voltage down to 220volts
Hi..can you use a contactor in the single phase AVS when you have a big load
Yes...…. so the AVS will control while the contactor carry the load.
Have connected 3 cables from contactor to the avs3p and then 3 wires output to the load but the avs is just off what might be the fault
Can I set the low below 180 maybe 170 is it advisable the current is very bad where I am
Avs3p have waited for the connection haven't seen
we have a pump which was set on 220v which warns under and over voltage and our power is fluctuating 220-251v so will that avs produce strictly 220 as out put thanks
NO......If your power is available but fluctuates quite often then what you need is A STABILIZER... it will give you the same value whether the voltage is high or low.
What AVS does protects your circuit by switching it off if power fluctuate BELOW or HIGH value that you set in the Device.
So what is the difference between using a phase failure and avs in three phase system
Phase failure protects the circuit from under voltage,over-voltage, and single phasing.
AVR primarily protects circuits from Power surges and spikes.
Thanks
HI Kindly show a wiring diagram how the AVS 30 can be connected from a Consumer Unit and the Circuit Breaker for Load ( say sockets)
ok let me work on that
Super super
Domingosfoiafeca tecnico de Frio
Please sir can I used avs 30 to control a three phase air-conditioning system like 5hp standing ac
Have connected 3 cables from contactor to the avs3p and then 3 wires output to the load but the avs is just off what might be the fault