Boiling of water with an initial vapor bubble by Ansys fluent

Поделиться
HTML-код
  • Опубликовано: 11 сен 2024

Комментарии • 5

  • @SamiaSadaf-ct2bv
    @SamiaSadaf-ct2bv 7 месяцев назад

    Thanks for the video...what if the container is horizontal and flow is from left to right.. should we have to give gravity as -9.81m/s2 ?

    • @tech_study_bhr1463
      @tech_study_bhr1463  7 месяцев назад

      If want to take care of gravitational force into account then you must have to take gravity as -9.81 m/s2.

  • @SamiaSadaf-ct2bv
    @SamiaSadaf-ct2bv 7 месяцев назад

    why you have given the temperature as 375.15K as initial values while initializing whereas you have taken the temperature at inlet as 390K?

    • @easyhack5859
      @easyhack5859 6 месяцев назад

      Yes this is what I couldn't understand

    • @easyhack5859
      @easyhack5859 6 месяцев назад

      As for my knowledge is concerned that in the whole field the intial temperature was kept as 375 k while inlet temperature was 390 k and atmosphere temperature was kept as 275 k. Bottom or inlet Wall temperature is always higher than internal fluid domain temperature that's why there is difference of temperature.