    @boylarga3705 3 года назад +2

    great job. i dont have problem yet with my inverter. but just in case this would be great help to me. thank you

  • @eyad.alnoun
    @eyad.alnoun 6 месяцев назад

    مشكور صديقي عمل رائع . والسؤال هنا . هل يمكنني ان اغذي الانفرتر من بور سبلاي 5 امبير 48 فولط اثناء التجريب . او حصرا اجربه عالبطاريات . وشكرا لكم

  • @gtasanambrus
    @gtasanambrus 10 месяцев назад

    Thank you! This fixed the code. But now the inverter does not detect the panels. When I connect the panels, the voltage drops to 0V. When I disconnect, it reads 400V.

  • @irfanshafiqueelctronics5257
    @irfanshafiqueelctronics5257 8 месяцев назад +1

    Sir exelint information video good work super

  • @distrimarlimitada1184
    @distrimarlimitada1184 2 года назад +1

    Dear query, I have the same inverter, it does not charge my battery after 3 hours of work.
    everything works fine and after a few hours of work the light on the screen panel turns off.
    I tested power input to the reverse and all good. Raul Chile

  • @thebasicconcepts2110
    @thebasicconcepts2110 2 года назад +1

    U have done a great job...

  • @lululili3246
    @lululili3246 3 года назад +2

    hi i have a problem with a 3kw hybrid inverter when I turn it on after 1min it turns off, do you repair them? thank you to you and good luck you have talent

  • @shahfahad8623
    @shahfahad8623 3 года назад +1

    Please upload more on 09 fault. I am also going to repair 5kv which have burnt irf4115 and 60h65 igpt

  • @icetroll734
    @icetroll734 3 года назад +2

    Hi! Great video, thanks!
    Can you let us know how to fix a ERR53 soft start fail on this inverter?
    Great work!

  • @dama054
    @dama054 3 года назад +1

    really good videos keep up loading them they are a great help thanks

  • @sahermakeupstudio1093
    @sahermakeupstudio1093 3 года назад +2

    Bro can you help me in some issues of 5 kw inverter .
    My inverter can not oprate in normal condition. His output side( F T) . Give me 5.0 reading but actually came 11.7 than inverter drive noraml run bettriy or wapda. So help me bro.

  • @khanmujeeb2747
    @khanmujeeb2747 3 года назад +1

    Nice vadio sir

  • @johannesdippenaar7789
    @johannesdippenaar7789 2 года назад

    Good quality repair and video.

  • @sebastianbrauer8150
    @sebastianbrauer8150 Год назад +1

    Hello what kind of circuit board is that at minute 21? we have 2 inverters, one with this board and one without this board. thanks for an answer.

    • @ALayoubiMaintenanceCenter
      @ALayoubiMaintenanceCenter  Год назад

      You are welcome dear friend
      Please join our channel to contact our technical team via whatsapp
      ruclips.net/video/a8uRXPejtvo/видео.html

    • @AtifAtif-gu2bj
      @AtifAtif-gu2bj Год назад

      ​@@ALayoubiMaintenanceCenterhow can I join your channel

  • @Alaouirachid1986
    @Alaouirachid1986 2 года назад +1

    bonjour j'ai un petit probleme j'ai une tension de 24v a la nuit au niveau d'entré panneau solaire de Steca .pouvez me dir d'ouvien cette tension merci .

  • @wisamalnajjar1501
    @wisamalnajjar1501 4 года назад +2

    Waw super ، Wirklich toll

  • @mohammedjehad1061
    @mohammedjehad1061 2 года назад +1

    ماشاء الله .هل انتم بالإمارات؟.ولكن هل تنطفئ الكهرباء عندكم😄
    نتعلم منكم الكثير شكرا لكم

    • @ALayoubiMaintenanceCenter
      @ALayoubiMaintenanceCenter  2 года назад

      يا هلا اخي الكريم..
      الامارات لا تحتاجنا..
      نحنا موجودون في بلدنا..الذي يحتاجنا..
      شكرا لكلماتك اللطيفة..

  • @darryljosephsmith2725
    @darryljosephsmith2725 2 года назад +1

    I want to know where i can get my mother board fixed because the installer cause the board to pop and now . I dnt have a working inverter. How much will it cost to fix?

  • @42FaLLeNAnGeL24
    @42FaLLeNAnGeL24 3 года назад +1

    hey i have a 2424msxe in parts i am only missing the screen and case, am i on a hunt for such. do know when i can get this? by chance do you have any? or do you have any 24v mpp solar cases i might be able to modify to fit?

  • @mbpowersalutionkasur1889
    @mbpowersalutionkasur1889 3 года назад +1

    Good job sir

  • @ziobit5177
    @ziobit5177 3 года назад +1

    Good morning I have a 5 kw Edison MKII inverter due to touch screwdriver between positive panel clamp and casing, it sparked and went out, I disassembled and found 5 shorted mosfets, I replaced it now it turns on but it gives me error 09, what else can i check? at sight there are no exploded components, the mosfets are K100E08N1 now measuring by comparison they all seem working, I'm desperate, if you have any advice thank you

    • @ALayoubiMaintenanceCenter
      @ALayoubiMaintenanceCenter  3 года назад +1

      Well my friend, I'll check and tell you and excuse me for being late because we're so busy

  • @محمدناصيف-ف9ف
    @محمدناصيف-ف9ف 4 года назад +1

    Woooow nice work

  • @Swenser
    @Swenser 2 года назад +2

    I got error code 03. battery overcharged. why would the unit over charge my battery and then tell me it's done it. very strange.

  • @سهادالأيوبي
    @سهادالأيوبي 4 года назад +1

    بالتوفيق يا رب

  • @yunodiewtf
    @yunodiewtf 10 месяцев назад

    I see a lot of these chinese inverters share the same fault codes, could it be they all got a common ancestor like it happened with stolen ELM327 firmware?
    If so I'd very much like to get my hands on the schematic diagram because I got a PH1800 5.5KW to play with, the goal is to use 96V or 192V Li-Ion instead of standard 48V battery.
    As a very general guess, replacing all DC mosfets, capacitors and transformer with appropriate voltage ratings and adding dividers to voltage senses could possibly work?

  • @soumyaaswaraajmoharana
    @soumyaaswaraajmoharana 3 года назад +2

    Sir what is soft start failure error 53 occurred and how we will prevent it from this fault ?

  • @kareemm.ateiza8202
    @kareemm.ateiza8202 3 года назад +1

    Nice Job. Please can you help with error code 01 or 02 fan not working

  • @indianbrijmohan8957
    @indianbrijmohan8957 3 года назад

    Suggest to my problems, DC bus suply is ok but 220v not out......?

  • @mowaisshahid
    @mowaisshahid 2 года назад +1

    Hello bro, if the inverex inverter is not charging battery efficiently from the mains, which sections and components should we check. Please help.

  • @usttadismaeel3529
    @usttadismaeel3529 4 года назад +1

    Good sir g

  • @Mored_4u
    @Mored_4u Год назад

    Can U fix error 9 for Powmr parallel hybrid inverter 5500w

  • @rmmlakshan3895
    @rmmlakshan3895 4 года назад +1

    my dear sir.. i have hybrid 2k inverter.there is have some problem.please help me..it's normally working but when i switch off the inverter that time coming on display input voltage (404v).after again switch on the inverter error (06) showing and continue bep sound.please can you tell me how can i repair it

    • @rmmlakshan3895
      @rmmlakshan3895 4 года назад +1

      ok sir..thank you very much..i'll send some video and photos..sir this is my whatsapp number +94758369965

  • @emmanueloffiong4652
    @emmanueloffiong4652 3 года назад +1

    Please can you help me on how to fixe error53 problem?

  • @Babarswat
    @Babarswat 3 года назад +1

    Can some one help me out? I have 3KVA inverter. was working well. due to bad weather the voltage of utility was fluctuating. the inverter was using battery power and at the battery was fully discharged. next morning i noticed that the inverter showing utility and battery source but not showing PV panels and connection, although there is current in the wires from PV.

  • @junjicapoquian9494
    @junjicapoquian9494 3 года назад +1

    Hello good day! Can I ask how to repair Code 02 for Voltronic vmii
    Thanks!

  • @lloydmurahwe2191
    @lloydmurahwe2191 3 года назад +1

    Nice video but needs audio explanation

  • @AsefHoseini66
    @AsefHoseini66 3 года назад +1

    Hi my friend, I have an inverter charger, the output of the device turns on for a few moments and then shuts down. What do you think is the problem?

    • @AsefHoseini66
      @AsefHoseini66 3 года назад +1

      @@ALayoubiMaintenanceCenter Thank you my friend🙏

  • @tatosaad1
    @tatosaad1 4 года назад +1

    فنان ...

  • @pedroresolve
    @pedroresolve Год назад +1

    Hello my inversor apresent the error08
    Can you help me?

  • @alexanderlehanofficial9611
    @alexanderlehanofficial9611 3 года назад +1

    My newly arrived hybrid power inverter fuse blow up everytime I ON it. Anybody can help pls?

  • @sidrasaeed269
    @sidrasaeed269 2 года назад +2

    Maintanance cost???

  • @kamlesankhia2430
    @kamlesankhia2430 3 года назад +1

    Good luck

  • @michaeljahbuikem6956
    @michaeljahbuikem6956 3 года назад +1

    I have a 3kva of same type but is not switching the relay

  • @mickeysherman4268
    @mickeysherman4268 3 года назад +1

    I have 3kva 24volts of this same type it has a fault code 06, how can I repair it? Please help???

  • @kenmaobi7300
    @kenmaobi7300 2 года назад +1

    Hello ALayoubi Maintenance Center, is there any way we can work with with you for inverter repairs and maintenance , especially for hybrid inverters

    • @kenmaobi7300
      @kenmaobi7300 2 года назад

      Can I have your email address

  • @naeemak63
    @naeemak63 3 года назад +1

    From where I can get spares ? in Islamabad/ Rawalpindi

  • @ladoscuropelis
    @ladoscuropelis 2 года назад

    good day Do you know what the error 99 slow boot failure means?

  • @imannwadinlatip
    @imannwadinlatip 2 года назад

    great sir, but i have question.. i got error 9 , then replace some burn mosfet into new one, after that got still error 9 , can u help me to solve this

  • @abdellahechakouki9134
    @abdellahechakouki9134 4 года назад +1

    3kv inverter fault out put Blanking solution ?please can't find the why it always flashes the exit

    • @ALayoubiMaintenanceCenter
      @ALayoubiMaintenanceCenter  4 года назад

      Hi dear,
      Can you explain more
      Does the error occur when operating on batteries?

    • @abdellahechakouki9134
      @abdellahechakouki9134 4 года назад

      @@ALayoubiMaintenanceCenter thank you, it was the problem of programming

  • @emmanueltaiwo801
    @emmanueltaiwo801 3 года назад +3

    good day please am trying to resolve error code 09 which means battery soft start failed on my 5kv steca inverter charger please i need help from you all

  • @electricalalnalysis5253
    @electricalalnalysis5253 3 года назад

    Hello dear.can you share me guide book for check part that damage

  • @alizaiter8726
    @alizaiter8726 2 года назад +1

    شو سبب هذا العطل ممكن جواب

  • @B4nan0n
    @B4nan0n 3 года назад

    This is impressive! Good job.
    I have a similar inverter charger, do you know why my batteries are not charging with ac input? I see the ac logo blinking only, not charging and I have grid like priority.

    • @ALayoubiMaintenanceCenter
      @ALayoubiMaintenanceCenter  3 года назад +1

      What is your battery type (gel..fld..etc)?

    • @B4nan0n
      @B4nan0n 3 года назад

      @@ALayoubiMaintenanceCenter lifepo4 80ah.
      My inverter charge my battery only with solar, for some reason doesn’t accept ac input from generator (223v 52hz )
      I tried all the different settings, and for some reason ac logo in screen is always blinking, only a second is charging from ac

    • @ALayoubiMaintenanceCenter
      @ALayoubiMaintenanceCenter  3 года назад +1

      Ok
      Try to check Setting programs
      (03 program)
      Try to put it
      APL
      Insted of UPS
      ...
      If didnot improve
      You must improve and repair your generator (50 hz)

    • @B4nan0n
      @B4nan0n 3 года назад +1

      @@ALayoubiMaintenanceCenter thank you so much! I tried that 2 settings today and I haven’t seen any changes, maybe the output of my generator is not stable and just got rejected by the inverter, thanks for helping me.

    • @ALayoubiMaintenanceCenter
      @ALayoubiMaintenanceCenter  3 года назад

      You are welcome..

  • @omarhawara5143
    @omarhawara5143 3 года назад +1

    👍🏻👍🏻👍🏻

  • @mathiasphiri722
    @mathiasphiri722 3 года назад +1

    How about fault 08 sir?

  • @awaisahmad1516
    @awaisahmad1516 3 года назад +1

    How to repair error code 08.

  • @kamlesankhia2430
    @kamlesankhia2430 3 года назад +2

    Sir please more videos

  • @abdulsattarrajakhaskhaily175
    @abdulsattarrajakhaskhaily175 3 года назад +1

    Sir fault error 56
    5kw mks

  • @praguesb
    @praguesb 3 года назад +1

    do you know a solution for error code 51?

  • @georgigeorgiev1379
    @georgigeorgiev1379 2 года назад

    Please help me what could it be wrong with mine,error 51 occasionally???

  • @picassoudemba1514
    @picassoudemba1514 3 года назад +1

    Please am trying to resolve error code 71 NE on one of my parallel inverter. Any idea?

    • @ALayoubiMaintenanceCenter
      @ALayoubiMaintenanceCenter  3 года назад

      Can send more information about this error ? inverter model ?

    • @picassoudemba1514
      @picassoudemba1514 3 года назад +2

      The situation is where one of my high frequency inverter is faulty and was taken to repair, after it was brought back. Will the parallel still be automatically synchronized? Because I had an experience with one inverter, they were paralleled to give 15kva single phase, after the repair we tried to connect it back. It showed error code 71 and NE intermidiately. But works fine as a single inverter. But when parallel it shows the above error I mentioned.
      Sometimes it sends fault signal to the other 2 working in parallel with it before and they'll show error code 80 or 60.

    • @ALayoubiMaintenanceCenter
      @ALayoubiMaintenanceCenter  3 года назад

      I will see and tell you

    • @picassoudemba1514
      @picassoudemba1514 3 года назад

      @@ALayoubiMaintenanceCenter ok sir.....I can't send video. Would've shown you.

    • @ALayoubiMaintenanceCenter
      @ALayoubiMaintenanceCenter  3 года назад

      To solve your problem
      Tell me the reason of fiest maintenance

  • @ndresz4239
    @ndresz4239 3 года назад +1

    Do You know a solution for error code 55?