Thank you! This fixed the code. But now the inverter does not detect the panels. When I connect the panels, the voltage drops to 0V. When I disconnect, it reads 400V.
Dear query, I have the same inverter, it does not charge my battery after 3 hours of work. everything works fine and after a few hours of work the light on the screen panel turns off. I tested power input to the reverse and all good. Raul Chile
hi i have a problem with a 3kw hybrid inverter when I turn it on after 1min it turns off, do you repair them? thank you to you and good luck you have talent
Bro can you help me in some issues of 5 kw inverter . My inverter can not oprate in normal condition. His output side( F T) . Give me 5.0 reading but actually came 11.7 than inverter drive noraml run bettriy or wapda. So help me bro.
bonjour j'ai un petit probleme j'ai une tension de 24v a la nuit au niveau d'entré panneau solaire de Steca .pouvez me dir d'ouvien cette tension merci .
I want to know where i can get my mother board fixed because the installer cause the board to pop and now . I dnt have a working inverter. How much will it cost to fix?
hey i have a 2424msxe in parts i am only missing the screen and case, am i on a hunt for such. do know when i can get this? by chance do you have any? or do you have any 24v mpp solar cases i might be able to modify to fit?
Good morning I have a 5 kw Edison MKII inverter due to touch screwdriver between positive panel clamp and casing, it sparked and went out, I disassembled and found 5 shorted mosfets, I replaced it now it turns on but it gives me error 09, what else can i check? at sight there are no exploded components, the mosfets are K100E08N1 now measuring by comparison they all seem working, I'm desperate, if you have any advice thank you
I see a lot of these chinese inverters share the same fault codes, could it be they all got a common ancestor like it happened with stolen ELM327 firmware? If so I'd very much like to get my hands on the schematic diagram because I got a PH1800 5.5KW to play with, the goal is to use 96V or 192V Li-Ion instead of standard 48V battery. As a very general guess, replacing all DC mosfets, capacitors and transformer with appropriate voltage ratings and adding dividers to voltage senses could possibly work?
my dear sir.. i have hybrid 2k inverter.there is have some problem.please help me..it's normally working but when i switch off the inverter that time coming on display input voltage (404v).after again switch on the inverter error (06) showing and continue bep sound.please can you tell me how can i repair it
Can some one help me out? I have 3KVA inverter. was working well. due to bad weather the voltage of utility was fluctuating. the inverter was using battery power and at the battery was fully discharged. next morning i noticed that the inverter showing utility and battery source but not showing PV panels and connection, although there is current in the wires from PV.
great sir, but i have question.. i got error 9 , then replace some burn mosfet into new one, after that got still error 9 , can u help me to solve this
good day please am trying to resolve error code 09 which means battery soft start failed on my 5kv steca inverter charger please i need help from you all
This is impressive! Good job. I have a similar inverter charger, do you know why my batteries are not charging with ac input? I see the ac logo blinking only, not charging and I have grid like priority.
@@ALayoubiMaintenanceCenter lifepo4 80ah. My inverter charge my battery only with solar, for some reason doesn’t accept ac input from generator (223v 52hz ) I tried all the different settings, and for some reason ac logo in screen is always blinking, only a second is charging from ac
@@ALayoubiMaintenanceCenter thank you so much! I tried that 2 settings today and I haven’t seen any changes, maybe the output of my generator is not stable and just got rejected by the inverter, thanks for helping me.
The situation is where one of my high frequency inverter is faulty and was taken to repair, after it was brought back. Will the parallel still be automatically synchronized? Because I had an experience with one inverter, they were paralleled to give 15kva single phase, after the repair we tried to connect it back. It showed error code 71 and NE intermidiately. But works fine as a single inverter. But when parallel it shows the above error I mentioned. Sometimes it sends fault signal to the other 2 working in parallel with it before and they'll show error code 80 or 60.
great job. i dont have problem yet with my inverter. but just in case this would be great help to me. thank you
مشكور صديقي عمل رائع . والسؤال هنا . هل يمكنني ان اغذي الانفرتر من بور سبلاي 5 امبير 48 فولط اثناء التجريب . او حصرا اجربه عالبطاريات . وشكرا لكم
Thank you! This fixed the code. But now the inverter does not detect the panels. When I connect the panels, the voltage drops to 0V. When I disconnect, it reads 400V.
Sir exelint information video good work super
Dear query, I have the same inverter, it does not charge my battery after 3 hours of work.
everything works fine and after a few hours of work the light on the screen panel turns off.
I tested power input to the reverse and all good. Raul Chile
Dear friend
Please join our channel
To contact the technical team
U have done a great job...
hi i have a problem with a 3kw hybrid inverter when I turn it on after 1min it turns off, do you repair them? thank you to you and good luck you have talent
Please upload more on 09 fault. I am also going to repair 5kv which have burnt irf4115 and 60h65 igpt
Hi! Great video, thanks!
Can you let us know how to fix a ERR53 soft start fail on this inverter?
Great work!
really good videos keep up loading them they are a great help thanks
A lot of thanks for your kindly words
@@ALayoubiMaintenanceCenter thank you for sharing your knowledge
We are going on upload more and more benifit tube as we can
Bro can you help me in some issues of 5 kw inverter .
My inverter can not oprate in normal condition. His output side( F T) . Give me 5.0 reading but actually came 11.7 than inverter drive noraml run bettriy or wapda. So help me bro.
Nice vadio sir
Thanks..
💐💐💐
Good quality repair and video.
Thaanks dear friend💐💐
@@ALayoubiMaintenanceCenter where are you based
Hello what kind of circuit board is that at minute 21? we have 2 inverters, one with this board and one without this board. thanks for an answer.
You are welcome dear friend
Please join our channel to contact our technical team via whatsapp
ruclips.net/video/a8uRXPejtvo/видео.html
@@ALayoubiMaintenanceCenterhow can I join your channel
bonjour j'ai un petit probleme j'ai une tension de 24v a la nuit au niveau d'entré panneau solaire de Steca .pouvez me dir d'ouvien cette tension merci .
Waw super ، Wirklich toll
Thanks dear
ماشاء الله .هل انتم بالإمارات؟.ولكن هل تنطفئ الكهرباء عندكم😄
نتعلم منكم الكثير شكرا لكم
يا هلا اخي الكريم..
الامارات لا تحتاجنا..
نحنا موجودون في بلدنا..الذي يحتاجنا..
شكرا لكلماتك اللطيفة..
I want to know where i can get my mother board fixed because the installer cause the board to pop and now . I dnt have a working inverter. How much will it cost to fix?
Its a 5kw solar inverter 48v .
hey i have a 2424msxe in parts i am only missing the screen and case, am i on a hunt for such. do know when i can get this? by chance do you have any? or do you have any 24v mpp solar cases i might be able to modify to fit?
welcome
we are sorry
We only repair damaged parts.
Good job sir
Thank you very much, we are at your service
Good morning I have a 5 kw Edison MKII inverter due to touch screwdriver between positive panel clamp and casing, it sparked and went out, I disassembled and found 5 shorted mosfets, I replaced it now it turns on but it gives me error 09, what else can i check? at sight there are no exploded components, the mosfets are K100E08N1 now measuring by comparison they all seem working, I'm desperate, if you have any advice thank you
Well my friend, I'll check and tell you and excuse me for being late because we're so busy
Woooow nice work
Thanks for watching
I got error code 03. battery overcharged. why would the unit over charge my battery and then tell me it's done it. very strange.
بالتوفيق يا رب
Thank you very much ❤️
I see a lot of these chinese inverters share the same fault codes, could it be they all got a common ancestor like it happened with stolen ELM327 firmware?
If so I'd very much like to get my hands on the schematic diagram because I got a PH1800 5.5KW to play with, the goal is to use 96V or 192V Li-Ion instead of standard 48V battery.
As a very general guess, replacing all DC mosfets, capacitors and transformer with appropriate voltage ratings and adding dividers to voltage senses could possibly work?
Sir what is soft start failure error 53 occurred and how we will prevent it from this fault ?
Nice Job. Please can you help with error code 01 or 02 fan not working
Ok
Code 01
One of the fans needs replace..
And 02 is over temptreture
Suggest to my problems, DC bus suply is ok but 220v not out......?
Hello bro, if the inverex inverter is not charging battery efficiently from the mains, which sections and components should we check. Please help.
Welcome,
Please join our channel to contact our technical team
@@ALayoubiMaintenanceCenter ok bro I have joined your channel
Now you have our whatsapp number..
Please call us
ruclips.net/video/a8uRXPejtvo/видео.html
Good sir g
Can U fix error 9 for Powmr parallel hybrid inverter 5500w
my dear sir.. i have hybrid 2k inverter.there is have some problem.please help me..it's normally working but when i switch off the inverter that time coming on display input voltage (404v).after again switch on the inverter error (06) showing and continue bep sound.please can you tell me how can i repair it
ok sir..thank you very much..i'll send some video and photos..sir this is my whatsapp number +94758369965
Please can you help me on how to fixe error53 problem?
Can some one help me out? I have 3KVA inverter. was working well. due to bad weather the voltage of utility was fluctuating. the inverter was using battery power and at the battery was fully discharged. next morning i noticed that the inverter showing utility and battery source but not showing PV panels and connection, although there is current in the wires from PV.
Hello good day! Can I ask how to repair Code 02 for Voltronic vmii
Thanks!
Please check
temp sensor or temp sensor circuit
Nice video but needs audio explanation
Hi my friend, I have an inverter charger, the output of the device turns on for a few moments and then shuts down. What do you think is the problem?
@@ALayoubiMaintenanceCenter Thank you my friend🙏
فنان ...
Thank you 😊
Hello my inversor apresent the error08
Can you help me?
Dear friend
We have 2 videos in our channel
Please join to get them
My newly arrived hybrid power inverter fuse blow up everytime I ON it. Anybody can help pls?
Maintanance cost???
Good luck
Thank you..
We will do as we can..
I have a 3kva of same type but is not switching the relay
I have 3kva 24volts of this same type it has a fault code 06, how can I repair it? Please help???
Hello Mickey
@@ALayoubiMaintenanceCenter thanks! I will send you message on WhatsApp soon...
Hello ALayoubi Maintenance Center, is there any way we can work with with you for inverter repairs and maintenance , especially for hybrid inverters
Can I have your email address
From where I can get spares ? in Islamabad/ Rawalpindi
good day Do you know what the error 99 slow boot failure means?
great sir, but i have question.. i got error 9 , then replace some burn mosfet into new one, after that got still error 9 , can u help me to solve this
Did you finally get it fixed
3kv inverter fault out put Blanking solution ?please can't find the why it always flashes the exit
Hi dear,
Can you explain more
Does the error occur when operating on batteries?
@@ALayoubiMaintenanceCenter thank you, it was the problem of programming
good day please am trying to resolve error code 09 which means battery soft start failed on my 5kv steca inverter charger please i need help from you all
Hello dear.can you share me guide book for check part that damage
شو سبب هذا العطل ممكن جواب
may be
short in output
reverse elec in the output
weak components by time
This is impressive! Good job.
I have a similar inverter charger, do you know why my batteries are not charging with ac input? I see the ac logo blinking only, not charging and I have grid like priority.
What is your battery type (gel..fld..etc)?
@@ALayoubiMaintenanceCenter lifepo4 80ah.
My inverter charge my battery only with solar, for some reason doesn’t accept ac input from generator (223v 52hz )
I tried all the different settings, and for some reason ac logo in screen is always blinking, only a second is charging from ac
Ok
Try to check Setting programs
(03 program)
Try to put it
APL
Insted of UPS
...
If didnot improve
You must improve and repair your generator (50 hz)
@@ALayoubiMaintenanceCenter thank you so much! I tried that 2 settings today and I haven’t seen any changes, maybe the output of my generator is not stable and just got rejected by the inverter, thanks for helping me.
You are welcome..
👍🏻👍🏻👍🏻
How about fault 08 sir?
How to repair error code 08.
Sir please more videos
Sir fault error 56
5kw mks
do you know a solution for error code 51?
yes
@@ALayoubiMaintenanceCenter can you tell us error 51?
Please help me what could it be wrong with mine,error 51 occasionally???
Please am trying to resolve error code 71 NE on one of my parallel inverter. Any idea?
Can send more information about this error ? inverter model ?
The situation is where one of my high frequency inverter is faulty and was taken to repair, after it was brought back. Will the parallel still be automatically synchronized? Because I had an experience with one inverter, they were paralleled to give 15kva single phase, after the repair we tried to connect it back. It showed error code 71 and NE intermidiately. But works fine as a single inverter. But when parallel it shows the above error I mentioned.
Sometimes it sends fault signal to the other 2 working in parallel with it before and they'll show error code 80 or 60.
I will see and tell you
@@ALayoubiMaintenanceCenter ok sir.....I can't send video. Would've shown you.
To solve your problem
Tell me the reason of fiest maintenance
Do You know a solution for error code 55?
yes