I have watched many videos illustrating Aspen Hysys, but this is the first one I enjoyed because your manner and because you mixed basic things with intermediate and advanced tips, which make me feel I'm not too far away from being a good user and I'm learning new pieces of information Thanks a lot
thank you so much Jefferson! It had been a while since I didn´t use HYSYS and this video was very helpful to recall. Excellent teaching and explaining, Thanks again!
Very informative session.I was a little confused if it is necessary to input and define the energy stream in such hydraulic cases where there are no significant involvement of heat transfer?
In Aspen hysys you always need to attach a energy stream to the pipe segment. If there is no heat transfer, or it is negligible, you just need to set energy stream as zero.
Hi Juan, yes it is. there are some different ways to do that. You can go to: Files => Options => Units Of Measure => scrolldown up to Variable format => Select Molar Fraction (for instance) => click on Format and define the numbers of fixed decimals you need. It is possible to show up to 9 decimals.
thank you for the video, but can you help me, because i don't know how to add a new component for example cineol in hysys, cos there isnt cineol in my aspen hysys, and i really need that component
Hi @Min Hyo Shin, to add 1,8-Cineole to your components list, you must add a Component List sourced at Aspen Properties. As per standard, Aspen HYSYS uses HYSYS Databank. You need to add Fluid Package based on Aspen Properties also.
Hlw Jeff...I am having difficulty in adding TEG makeup in the mixer operation...with my dehydration model in Aspen hysys...any help...can you give some steps to follow?what to include in TEG Makeup stream and how to get it...
Olá! Muito interessante os vídeos! Estou usando um outro software em um trabalho. Pesquisei sobre o Hysys no começo também. Você sabe informar em quanto está o custo do software e se tem uma versão para estudante? Obrigado!
Olá Henrique, o Aspen Hysys está na cas dos 20k~40k USD dolares/ano. Não existe versão de estudante para o público geral. Você vai ter que acessar via instituição de ensino, empresa ou via cópia não autorizada do AspenOne Engineering disponível na internet.
Why have we selected line sizing for stream 1 whereas we need to size line 2 which runs from pump discharge to vessel B inlet having a length of 400 m?
Because in this case, volumetric flow is basically the same as water is a incompressible fluid. In any case, it is better t always use the stream you are dealing with to guarantee the correct results.
Hi Jeferson, thanks for your tutorials!Appreciate! I just have one question about the pipe sizing attachments you used. In my HYSYS V11 i don't have the option to choose to calculate the pressure drop or the diameter, but under calculation type i have DESIGN or RATING, and this funcion in attachments tab is not called pipe sizing as yours, but "line sizing manager", and as said it won't allow me to choose calculating between diameter or pressure drop, but between DESIGN and RATING. What that mean? And it doesn't show me all the informations shown by you (for example it doesn't show the reynolds number). Could you please help me? Thank you very much
Hi Luca, many people ask me about this difference. It is time to I record a video to clarify this :) I will ask for your patience, but to give an answer, consider pipe sizing = line sizing. V11 has more options for preliminary sizing than V10.
@@jefersoncostaengineer thank you to you for your patient! I had understood that pipe size=line size tool, but they looks different. Pipe size tool seems to me easier to use. So, we're waiting for you! Cheers
Hello sir good day. In aspen hysys v11, there is no pipe sizing option in the analysis of each material stream. However, line sizing manager is present in aspen hysys v11. How can i find pipe sizing sir using v11 in order to add pressure gradient?
Hi Elhassen, yes you can. Follow the same procedure, however the interface in a little bit different than previous Aspen Hysys. You can set pipe size based on fluid velocity, pipe pressure drop or max Rho. Just go to Settings tab.
hi, I tried to do simulation on production of butadiene but it couldn't be solved. can you please do hysys tutorial on two reactants and 2 products reaction in plug flow reactor? thank you so much.
Hi, AutoCad is a very useful CAD software for P&ID development. As chemical process engineer in plant design, it is a great side skill to add to the resume, in my point of view :)
I have watched many videos illustrating Aspen Hysys, but this is the first one I enjoyed because your manner and because you mixed basic things with intermediate and advanced tips, which make me feel I'm not too far away from being a good user and I'm learning new pieces of information
Thanks a lot
😍 Thanks for your kind feedback Alrawi 😄
I want to learn full process design.
Are you making videos on this
Join the Chemical Process Engineer Journey Workshop at www.jefersoncosta.com and verify with your own eye Khan, how I can help you 😇
@@jefersoncostaengineer thanks sir
@@jefersoncostaengineer
Very much helpful. Keep doing your good work
Thanks for your a kind lecture of hysys.
🥰 Thanks for sharing your feedback
thank you so much Jefferson! It had been a while since I didn´t use HYSYS and this video was very helpful to recall. Excellent teaching and explaining, Thanks again!
Very informative session.I was a little confused if it is necessary to input and define the energy stream in such hydraulic cases where there are no significant involvement of heat transfer?
In Aspen hysys you always need to attach a energy stream to the pipe segment. If there is no heat transfer, or it is negligible, you just need to set energy stream as zero.
How to get this software (i'm beginner) I've tried many ways but I'm not sure what I'm looking for.
Very Informative. Can you please tell me sir where did you get the maximum allowable pressure drop of 0
.5 barg?
Thank you.
This is only an arbitrary number Subhradip. Max DP is a project specific and you can get some references in standards like API 14E. 😁
Okay thank you sir.
Thenk you for sharing information
Dear sir, can you make video on how to make P&ID?
Hi Mahek, you can start with this video ruclips.net/video/7iK0kmmsfrY/видео.html
Thank you it's helpful
Great video, it was really helpful, please can you make a video on how to add a distillation tower and a membrane unit.
Dear Jeferson,
It is possible to increase the decimal places from 4 to 6 in the Hysys composition in order to get the ppm results?
Best regards
Hi Juan, yes it is. there are some different ways to do that. You can go to: Files => Options => Units Of Measure => scrolldown up to Variable format => Select Molar Fraction (for instance) => click on Format and define the numbers of fixed decimals you need. It is possible to show up to 9 decimals.
@@jefersoncostaengineer . Thank you. Best regards
Sir can you please teach us how to work on Hysys?
Boss I need the software
Would the adjust function still work if we place more connections after the pipe segment such as elbows and valves?
Hi Ali, yes it will work because Adjust will be monitoring the process variable.
Hi Mr jeferson, thanks for the tutorial so far, how can one use HYSYS SIMULATION to predict hydrate formation conditions in gas pipeline
Yes, Vicent, you can. Use the stream analysis tool.
Great training stuff. Do you have any training for Hysys Dynamic??
Not yet Sam. i will add that soon to my Inprocess Booster 😇
Hi, i have HYSYS V11 and we have lin sizing manager instead of pipe sizing, and the pressur drop is black empty
Hi Merabet, try this video to clarify your questions :) ruclips.net/video/fdLQCNS5UYw/видео.html
thank you for the video, but can you help me, because i don't know how to add a new component for example cineol in hysys, cos there isnt cineol in my aspen hysys, and i really need that component
Hi @Min Hyo Shin, to add 1,8-Cineole to your components list, you must add a Component List sourced at Aspen Properties. As per standard, Aspen HYSYS uses HYSYS Databank. You need to add Fluid Package based on Aspen Properties also.
Do you have any things about optimizer?
Not yet Ali, I will consider that :)
successfully completed 3rd part...
Wow, you are doing great. Meet :)
Please if you don't mind, kindly hook me up with the hysis installation file(a safe download link or something). Thanks
Hlw Jeff...I am having difficulty in adding TEG makeup in the mixer operation...with my dehydration model in Aspen hysys...any help...can you give some steps to follow?what to include in TEG Makeup stream and how to get it...
Hi Emmanuel, I did not forget about you. I am verifying how I can cover this topic in a live session 😁
Olá! Muito interessante os vídeos! Estou usando um outro software em um trabalho. Pesquisei sobre o Hysys no começo também. Você sabe informar em quanto está o custo do software e se tem uma versão para estudante? Obrigado!
Olá Henrique, o Aspen Hysys está na cas dos 20k~40k USD dolares/ano. Não existe versão de estudante para o público geral. Você vai ter que acessar via instituição de ensino, empresa ou via cópia não autorizada do AspenOne Engineering disponível na internet.
Wonderful job man. Many thanks.
Sir, do you have biogas simulink model using anaerobic digestion?
Hi Vinay, I have seem some papers talking about that, but it is not of most use to my work. I use process simulation for Biogas upgrading.
@@jefersoncostaengineer sir, if possible you able to do that simulation?
please ,can you help me
How can I enter ejector in aspen hysys
It is necessary
thank you
Why have we selected line sizing for stream 1 whereas we need to size line 2 which runs from pump discharge to vessel B inlet having a length of 400 m?
Because in this case, volumetric flow is basically the same as water is a incompressible fluid. In any case, it is better t always use the stream you are dealing with to guarantee the correct results.
Please l need link for download aspen hysys v8
Hi Jeferson, thanks for your tutorials!Appreciate! I just have one question about the pipe sizing attachments you used. In my HYSYS V11 i don't have the option to choose to calculate the pressure drop or the diameter, but under calculation type i have DESIGN or RATING, and this funcion in attachments tab is not called pipe sizing as yours, but "line sizing manager", and as said it won't allow me to choose calculating between diameter or pressure drop, but between DESIGN and RATING. What that mean? And it doesn't show me all the informations shown by you (for example it doesn't show the reynolds number). Could you please help me? Thank you very much
Hi Luca, many people ask me about this difference. It is time to I record a video to clarify this :) I will ask for your patience, but to give an answer, consider pipe sizing = line sizing. V11 has more options for preliminary sizing than V10.
@@jefersoncostaengineer thank you to you for your patient! I had understood that pipe size=line size tool, but they looks different. Pipe size tool seems to me easier to use. So, we're waiting for you! Cheers
great
Hello sir good day. In aspen hysys v11, there is no pipe sizing option in the analysis of each material stream. However, line sizing manager is present in aspen hysys v11. How can i find pipe sizing sir using v11 in order to add pressure gradient?
Hi Stefan, they are the same 😅. I will add an audio in my telegram channel INPROCESS for better clarification 😇
www.jefersoncosta.com/inprocess
at 21:11 (Time in video) we can't find this in Aspen Hysys V 11 ?
Hi Elhassen, yes you can. Follow the same procedure, however the interface in a little bit different than previous Aspen Hysys. You can set pipe size based on fluid velocity, pipe pressure drop or max Rho. Just go to Settings tab.
Good sharing boss
I'm using Aspen Hysys V11 and I didn't find out the pipe sizing option in analytics section, how can I resolve this issue😟
Hi, in V11 this function is named Line Sizing Manager. In plant design point of view Line Sizing = Pipe Sizing. 😅 I hope it have helped you 😁
@@jefersoncostaengineer Thanks for giving clarity about my doubt😁
good
hi, I tried to do simulation on production of butadiene but it couldn't be solved. can you please do hysys tutorial on two reactants and 2 products reaction in plug flow reactor? thank you so much.
Are u talking about 1,3-butadiene?
What's your opinion about AutoCAD Plant 3D?
Hi, AutoCad is a very useful CAD software for P&ID development. As chemical process engineer in plant design, it is a great side skill to add to the resume, in my point of view :)
in hysys version 11 not able to change units of pressure. doesnt show a arrow next to pressure to flip units
Hi Daraj, there are many ways to change units in Aspen Hysys V11
Is it possible to model biomass through HYSYS?
Hi Ron, this is a job better performed by Aspen Plus. You can find some papers for this application with Aspen Plus.
Thanks 😊 it real helped me sir
Thanks for sharing with me Mohamed :)
I joined telegram channel but i did not find the problem pdf sir ???
Hi Moatasem, please take a look again on INPROCESS. See you :)
@@jefersoncostaengineer
Got it ..thanks ❤
Sir , could I get hysys software please!
google aspenone engineering
@@jefersoncostaengineer could u be more specific, I can't catch you well
You can look for that on Google searching for AspenOne Engineeering
Класс
👍👍👍
👍
geoo
thanks jeferson, please insert your telegram address.
Hi Elham, link to telegram channel t.me/chemicalprocessengineer
W।