Inverter Refrigerator R600a Gas Charging ! How To Charge R 600a In Inverter Refrigerator ! गैस चार्ज
HTML-код
- Опубликовано: 7 ноя 2024
- Inverter Refrigerator R600a Gas Charging ! How To Charge R 600a In Inverter Refrigerator ! गैस चार्ज
Hi Friends,
I am Ismail Khan and all of you are most welcome in my RUclips Channel Ideal For Technical
In this video I have Explained about R 600a Gas Charging In Inverter Refrigerator,
I have Explained completely about gas Charging such as brazing of pipe in system, vacuum the refrigerator by vacuum pump and charged the R 600a gas without weighing scale
In this video I have charged the refrigerant in refrigerator by its standing pressure and back Pressure
By this video every one can learn A To Z about gas Charging in refrigerator or Inverter Refrigerator and also in deep freezer , bottle cooler and Water cooler.
In this video I have Explained that how to charge R 600a Refrigerant In Samsung Digital Inverter Refrigerator.
It is very important to charge the gas or Refrigerant by weight in Inverter Refrigerator But You Can Charge Any Refrigerant or gas In Inverter Refrigerator without weighing scale by Following some Important Tips and tricks.
Queries Solved:-
1 Inverter Refrigerator Gas Charging R 600a
2 Gas Charging In Inverter Refrigerator R 600a
3 R 600a Gas Charging In Inverter Refrigerator
4 Inverter Refrigerator Gas Charging
5 R 600a Gas Charging In Refrigerator
6 Gas Charging R 600a In Refrigerator
7 How To Repair Inverter Refrigerator
8 Inverter Fridge Repairing
9 Repair Inverter Refrigerator
10 Gas Charging In Convertable Inverter Refrigerator
To know more about important tips and tricks please watch this video
Hope you understand and enjoy this video
Thanks
About The Channel:-
Dosto Mere RUclips Channel Ideal For Technical Ke zariye Refrigeration And Air conditioning, Electricals, Electronics, Mobile, RUclips Channel Aur Computer Se Related Technical Knowledge, Tips And Tricks Ke Saath Social Welfare Se Related Video Upload Kiye Jaate Hai
Videos Ko Dekh Kar Comment Zaroor Kijiyega
Song/Music :-
Song/Music Attribution Not Required Provided By RUclips Library
Disclaimer :-
Copyright Disclaimer Under Section 107 Of The Copyright Act 1976,
Allowance Is Made for " Fair Use " for Purposes such as Criticism, Comment, News Reporting, Teaching, Scholarship And Research, Fair Use Is A Use Permitted By Copyright Statue That Might Otherwise Be Infringing
Nonprofit, Educational Or Personal Use Tips The Balance In Favour Of Fair Use.
Thank You So Much
#inverterrefrigeratorgascharging
#r600acharging
#idealfortechnical
Contact For Business Inquiries :-
ismail05ideal@gmail.com
गुड वर्क सर जी माशा अल्लाह आपके समझाने का तरीका बहुत ही सटीक बहुत ही आसान रहता है अल्लाह आपको लंबी उम्र से नवाजे आमीन सुम्मा आमीन
Masha Allah sir apka video pura samajh me aa jata hai
Jazak Allah boat achay sai bataya ap nay zabardast. From Pakistan.
Shukriya 🌹👍
Keep Watching 👍
Very nice and informative vido Thanks
Welcome 👌👍👍
Maja aa gaya sir ji mast video🎥🎥🎥 your best👍👍👍👍👍💯💯
Thank You So Much 🌹👌
Bahut ache se samajh aaya hai sir
Bahot accha trik bataya hai ostase👌👨💼👨🔧🇮🇳
Another very useful video for learner's to learn how to do work in professional way, Thanks
Your Welcome 👌
Thanks for Appreciation 👌👍
Very good sir
Sabse badhiya video thank u sir
Bahut Shukriya 👌
app ne ekdam propar video bnai h sir g thanks ❤
Thanks 👍🌹
Please Share It As Much As Possible 👍
Thank you sir full video upload kiya👍🏻👍🏻👌🏻
👍👍
Important knowledge de diya sir ji
Sir ye bataiye single door me bhi 0 se thora kam rakna hai pressure ko
Single aur double door se matlab nahi hota
Kisi bhi refrigerator me R600a charge hogi to yahi back pressure rahega 👌
Nice Question 👍
@@IdealForTechnical thank you sir
बहुत अच्छा बेरी गुड भाई +सर आप ने बहुत अच्छी तरहा समझाया
Apka Bahut Shukriya 👌
बहुत बहुत धन्यवाद गुरूजी 🙏🙏
Bhut sahi hai guru ji
Thanks 👍
Good 👍 job bro
Thank you so much 🌹🌹
Very helpful video sir ❤
Very nice, shukriya Bhai.
Thank u Janab, good explanation. Next time tell us IPM fault finding.
R134A vs R600 . Konsi gas new hai and konsi gas ki cooling best hai
R 600a
Thank you sir ❤️❤️
Welcome 👍👍👌👌
Sir app ne 600gas Friz me fleshing krna nhi btaya kya Esme flexing jruri nhi hai krpya app hme btaye kaiSe krte hai
Answer
What cfm is your vacuum pump and what micron is your vacuum in system
1.8 CFM And 500 Microns which is about 29.9 Inches Hg
Sokryaa jonab...assalamoalaikom 🌷
Walaikum Assalam
👌👌👌👌
Sir r600gas ko charge karke kya ham pin balb ki jagah pe ham punc karke brijing nahi kar sakte kya??
Kar sakte hai agar ap charging line ko perfectly Punch kar de to
Lekin kyuki R 600a Flammable gas hai isliye Pin Valve best option hai
@@IdealForTechnical ok thank-you sir
Your Welcome 👍
Please Share This Video As Much As Possible 👌
Very nice sir ji
Thank you sir.God bless you
Thanks 👍🌹
Super explanation
R 600 ki Bajay Hydrocarbon Charge krenge to kya Problem hogi sir
Hydrocarbon Charge kar sakte hai 👍
Assalamu Alaikum Ismayil sir, godrej single door gas R134a. Body condenser both side heat he, filter bhi heat he. Lekin freezer frost nahi. Halka cooling he. Freezer mem hissing awaz he.
केप्लैरी choking problem hai bhai
Choking ho gaya hai
Good VEDIO sir
Complete video dekha apne Naim Saheb
Sir ji falashing ka jaruri nie kya.
Flushing bahut zaroori na ho to nahi karna chahiye
Kyunki flushing se bahar ki Air ke saath system me Moisture bhi chala jata hai
Ye best tarika hai
👌👍
Thanks for video
Nice video sir thanks
Welcome 👌
Share it Please
Assalamualaikum Khan saab standing pressure bhar ne k baad jab fridge ON karte hain toh gauge ki needle neeche nahi ati kya problem hosakti hai
Inverter compressor thoda lime le sakta hai,
Kaun sa compressor hai aur ap kitni der me check kar rahe hai
@@IdealForTechnical compressor toh ON hota hai lekin needle 45 hi rahta hai neeche nahi ata
@@syedrahman7391 Compressor Ki Pumping Fail Hai
Good video sir
Good video sir
And
How to flashing video karo plz sir
Ok 👌
Hello
Sir
Inverter Fridge mai compressor on kar ke pressure chack par sakte hai..... ya flush kar sakte hai....
Sir jaisa apne bataya maine ek freedge me 25 minute vaccume karke gas charging kiya 00.3 amp show kar raha hai lagbhag 10 minute chalke compressor off ho jata hai lg ka INVERTER compressor hai maine 8 se 10 ka jo compressor start hone ka timing hai usko kit se jaldi start hone ke liye thermostat ka feedback ko bypass karke jaldi se compressor ko on karwata hu isi se aisa to nahi ho rha hai help me
Thank you vidiyo ❤️👍
Your Welcome 👍👌👌
Very good bhai sahab very good work
Bahut Bahut Shukriya 👌🌹
Good job sir
Thanks 👍
What type of micron gauge you are using
Very informative video for me
Keep Watching 👌🌹
Subscribe my channel 👍
Excellent
Thanks 👍🌹
Compound gauge is having 2 meters
One red and one blue what is the use of the red one please explain
Actually it is called as manifold gauge set which has two gauges
Blue colour gauge is compound gauge because it has two readings below zero to -30 for vacuum and above zero to 150 psi for low pressure or back pressure
The red one is high pressure gauge to check high pressure of the system
A good idea is to fill the compressor with water before regassing. Then there is no need to vacuum
Thanks sir
DONPER AZ110WY1A compressor क्या कॉपर वाइंडिंग आता है ???
यह compressor कैसा है ?
इस की quality कैसी है ??
मैं एक फ़्रिज लेना चाहता हूँ उस मे यह compressor लगा है, क्या फ़्रिज ले लेना चाहिए ??
Weight karke barabar 27 grms R600a gas single door godrej mem charge kiya . freezer full frosting hogaya, but suction line compressor body thak frosting aarahahe. Phir bhi gas kamthi kamthi karke bhi sweating aarahahe. Tho ye weight karke bhi kyom aise.
Abhi compressor ki speed full hogi isliye suction par Frost àa raha
Kuch der chalne dijiye jab compressor ki speed normal hogi to ye theek ho jayega
Abhi apka compressor 0.5 se zyada ampere le raha hoga jab speed normal hogi to ampere aur kam hoga
@@IdealForTechnical inverter type nahi, normal godrej single door non inverter he.
@@coolstaracworks7068 Gas thodi si kam kijiye
Back Pressureaur Ampere kitna hai
@@IdealForTechnical unit sticker same 0.8 amp. Running time mem 0 or -1 thodi time ke bhad -10. Freezer full frosting. Suction line over cooling and sweating gas kam karneki bhad bhi. Freezer change kiya same godrej original.
thank s sir g
Good
Thanks 👍👍
Good Sir Pressures in Hindi and English also
Sir ji jinti vi gans hoty hai uska bike presor detail Mai likh kr btaey kitna hota hai
Ok Sir 👍
Awesome👍
Keep Watching 👍
👌👌👌👌👍
🌹🌹👍
Sar Mera double door inverter fridge hai ismein Maine 15 din pahle gas bharvai thi gas bharwane ke 2 din bad se hi Na kuchh Ajeeb si chemical ki smell a rahi hai meri fridge mein jo ki mere rakhe hue khane mein bhi Ho jaati hai to kya mere fridge mein kya problem hai mujhe bataen
Kya apki fridge me cooling ho rahi hai
Bahut Laajwaab guidance 🌷🌹🌺👍
Thanks 👍🌹
Sir Maine non inverter 600a fridge me gas charge kiya to uska back presar thik h lekin idel 15 bta rha h aur secsan line me ice bhi bhut a rhi a kya karan h
Back pressure kitna hai,
Mujhe lag raha gas over charge hai
Vacuum pump kon sa or kesa lena chiya
Two Stage Rotary Vacuum Pump, Kisi bhi Brand ka
Nice
Thanks
Your Welcome 👍👌
Sir R-410 back Presar kitna chaiye
110 PSI ke aas pass
Inverter compressors ka discharge pressure kitna hona chahiye sir
Where are you from sir.
I am from U P India and You
@@IdealForTechnical sir M.P
Sir ek invator freze hai coling bhi krra hai lekin uska comprassor kabhi kbar awaj karta hai gas mene 45 gram dali hai
Thank kyu 🙏
Your Welcome 👌
Please Share It 👍
👌👍🙏🙏🙏
Thanks 👍👍
Pin wall likage karega tab kiya Karna h sir
😂 Pin Valve Change Karna hoga 😂👌
Wonderful bro 💐
Thanks a lot 👍
Back ground my please sound Nikal do bhai
Bhai gas r600 60g refilling and filter/dryer changing.. kitna genuine amount hona chaiye??
Cost pooch rahe hai ya technicians ka charge pooch rahe hai
@@IdealForTechnical,bhai total kharcha alag karke batana??
@@manujain93 technicians 1200 se 1800₹ charge karte hai
@@IdealForTechnical samsung inverter double door h kitna Dena chaiye?
Sir Sucation line ace kyu hota hai please🙏 replay
Gas over charge hone par aisa hota hai
Ur koie karan hai
Please🙏 reply
@@MR.ABHIJIT6196 Aap Refrigerator ke Baare me pooch rahe hain to ye problem gas over charge hone se hoti hai
👍👍🏆
🌹👌
DC compressor hum kase pehachan ne ge
Resistance check kijiye,
Teeno terminals par same resistance hoga
Sir gais kit kaise chenge kre please help me
Sir ji withaut vaccum R600 gas kese charge kare
Is video ko complete dekhiye
Is video me yahi to samjhaya hai
Sir yahe modle ka filter chok hai kaise theek kre
Filter change kijiye
Gas charge ke time filter zaroor change kar diya kijiye
R-134 gas ka back presar 10-12 rakna chaiye!
Mausam ke hisab se kuch up down ho sakta hai
Pls batao aur Chouk hone se kaise bache
Ab bath he ke gas kyu leak huvva sir
ruclips.net/video/Z1mdo3ptis8/видео.html
Ye video dekhiye
Sir jab ye likh tha tab iski koi lahite biling kar rhi thi kya sir😭
Nahi
@@IdealForTechnical ok thanks sir
Sir mere refrigerator me bhattt Bhatt ki awaj aati chalta thoda band ho jata please help
runing.pressure.kitna.honaa.chaahiye.back.pressure.kitna.hona.chahiye.
Running aur back pressure ek hi hota hai jo R600a ke liye 1 se -1 ke aas pass rahta hai
Iska standing pressure 40 psi ke aas pass rahta hai
Caplry size bata dijiye sir😢😢😢
🙏
,,👌🙏
Sir एम्पियर कितना लेगा
Ye inverter model hai to iska ampere fluctuate karta hai
0.1 se 0.7 ampere tak
No inverter hai to sir कितना एम्पियर
Sir frizer bar bar chouk kyu hota hai gas charge karte samai
System me thoda sa bhi chok ho to zaroor flush kijiye
Tab chok nahi hoga
Flash nahi capiliry change ya proper vacuum karay
@@jugalkr.pandey" Flash"
Nahi Flush hota hai
Fridge Mein gas top pop ho sakti hai
Ji haa,
Agar charging line me jagah ho to
Sir mera vi D girkar ka cooling nahi ho raha hai
आपने गैस माइनस दो रखी या जीरो ये तो बताया ही नहीं....
Inverter compressor ki speed fluctuate karti rahti hai isliye ye fix nahi ho paata
-2 pe rakhna hai back pressor
Fix nahi rahta
Compressor ki speed ke hisab se fluctuate karta hai
To firr exactly kitna rakhna hoga invetor or non invetor 600 me back pressor
@@skhanzalori957 Non Inverter me ( -2 se 0 )
Inverter me fix nahi rahta ( +2 bhi Ho sakta hai
Due to Fluctuation of Compressor Speed
Ok sir 👍 thx
@@skhanzalori957 Your Welcome 🌹
Hii
Aap mechanic nahi hai condenser plus ne kiya cooling,coilll plus ne kiya direct gass,charge kar rahe ho
Sir per apne flushing nhi kya😅
Leak kon cheq karega
Un professional work chicha weight karke gas charge karo vacuum bhi sahi se karo
Lagta hai Complete Video Apne Nahi Dekha
Vacuum bhi proper hai aur Weight ke mutallik maine clearly explain kiya hai
@@IdealForTechnical pura video dekhchukha aaptho andaze se gas charge kar rahe ho aur nrv valve bhi nhi lagana aur two side se vacuum kijiye videos aap banare tho professional technician ke jaisa banaiye aur new technicians ku kuch Acha knowledge milsake
NRV nahi Lagana To Kya Karna hai, kya sabhi ke paas lockring tools hota hai
Mai kisi fully equipped workshop ke hisab se nahi explain kar raha hoo
Maine clearly kaha ki best tareeka kya hai par aap is tarah se bhi kar sakte hai
Isiliye maine apko kaha ki apne video complete nahi dekha
Waise comments karna bahut asaan hota hai 😂
Thanks For Suggession 👍
@@IdealForTechnical mera yeh matlab yeh nhi aap samjhate Acha magar usme quality work nhi hai r600 refrigerant proper tarikhe se karna padhtha gas charge tools rakhiye waise tools mahnege nhi hai weighing scale hai aur pinching plier bas aapko uthna kum hai aapki video mei
Aap ka naam aur kahan se ho aap?
Kya gas ki bottal full hai aap ne tin ko ulta karke gas charge nahi kiyaa