Это видео недоступно.
Сожалеем об этом.
200 Amp elbow termination
- Добавить в
- Мой плейлист
- Посмотреть позже
- Поделиться
Поделиться
HTML-код
Размер видео:
- Опубликовано: 30 мар 2020
- 200 amp elbow termination Edmondson
Комментарии • 54
Следующие
Автовоспроизведение
What's a "Parking stand" ??Bobsdecline - Lineman blogger
Просмотров 37 тыс.
Why is there more than 200 A worth of breakers inside of a 200 amp panel?!Electrician U
Просмотров 583 тыс.
15kv 200amp load break elbow installationJacob Young
Просмотров 72 тыс.
Inside Lil Baby’s Stylish Atlanta Oasis | Open Door | Architectural DigestArchitectural Digest
Просмотров 2 млн
Rhea Ripley, Liv Morgan, Dominik Mysterio Talk Things Out | WWE Raw Highlights 8/12/24 | WWE on USAWWE on USA
Просмотров 873 тыс.
Men's 100 Meter Finals Were HISTORIC || Noah Lyles VS. Kishane Thompson - Paris Olympics 2024Total Running Productions
Просмотров 2,9 млн
Club América vs. St. Louis CITY SC | Leagues Cup | 6-Goal Thriller! | August 13, 2024Major League Soccer
Просмотров 137 тыс.
35kv elbowBarry Grounds
Просмотров 12 тыс.
Second Points of ContactNorthwest Lineman College
Просмотров 47 тыс.
How to install 200A loadbreak elbows | Maddox TransformerMaddox Transformer
Просмотров 3 тыс.
What's a bayonet fuse !?Bobsdecline - Lineman blogger
Просмотров 18 тыс.
Professor Has HAD ENOUGH Of “Woke” Double StandardsThe Based Conservative
Просмотров 1,5 млн
Four Steps to Flawless Wire Joints (How to Solder)Will Donaldson
Просмотров 187 тыс.
200A Loadbreak Elbow Installation - Hubbell Power SystemsHubbell Power Systems
Просмотров 73 тыс.
How To Dig The Perfect Post HoleSWI Fence
Просмотров 424 тыс.
Underground SpliceT&D World
Просмотров 190 тыс.
ВОТ ПОЧЕМУ Я ПЕРЕЕХАЛ В ОБЛАСТЬ И БОЛЬШЕ НЕ ВЕРНУСЬ В ГОРОД.AcademeG DailyStream
Просмотров 299 тыс.
За что Сергея Доренко уволили с Первого каналавДудь Shorts
Просмотров 221 тыс.
В Курскую область перебрасывают срочников. ВСУ наступают. В России грядет мобилизация. Атака дроновРадио Свобода
Просмотров 791 тыс.
Первый гол Килиана Мбаппе за «Реал» #shortsOkko Спорт
Просмотров 119 тыс.
would you eat this? #shortsZach Choi ASMR
Просмотров 370 тыс.
@ Zhindong Da Fei Xin (O2546321517)# Old Iron Alopecia Rescue PlanWang's Funny Videos
Просмотров 2,2 млн
YouTube и Точка. Жуткий баг ютуба выдающий странные роликиMysteryForce
Просмотров 1,2 млн
People like you really make RUclips a valuable tool. Thanks for taking the time so share your knowledge.
Always nice to see how other places to it. We do ours a little different. We strip the outer jacket until a few inches above the conduit. But a water seal around it and that cable is so much more flexible. Also we twist the bleeder wire on to the concentric and wrap it going up the elbow before landing it. Solid video. Always wondered how these elbows differ from other styles.
Well done, 2 things that got in my mind during the video. First, the press fittings that I know had to be started all the way back and than the second, third, fourth towards the lug. In that way you'll force the conductor into the press fitting and create additional contact area at the conductor face. It might not be important on small connectors like this, but definitely on 1000+ amps. Second thing the grease/clay inhibitor, you want to have the full amount of it inside the press fitting to guide heat out of the core and transfer it into the lug. Beside the temperature thing you also make sure that humidity has no chance to enter even if the outer isolation fails over the years.
Just started off as a UG apprentice very informative video. Thank you sir.
Any tips? I’ve been doing underground for a few years but my company wouldn’t put ug guys through apprenticeship only guys in the building. Going to do it on my own
@@GageDunnbar be persistent, if you want to get into a apprenticeship program find contractors that offer an apprenticeship program as a benefit. I work for a tier one contractor for a major north Texas co-op. Also, don’t be discouraged to start off using a shovel again.
The V part of that probe tool is used so the wire sets it’s self along the wire and you can use a ratchet motion to strip back that jacketed neutral!!
All good but one tip for those working in a hot tx. Make sure to keep those concentric away from anything that ain't equipotential to ground.
This was very informative. Loved it
Solid videos dude. A lot of good pointers 👍🏻
Thank you for posting this.
AWESOME helpful video!
Great work!
follow the instructions in the elbow package ...can't go wrong ...
Great video but I’m pretty sure you have to measure your 6 7/8 after you have already pressed your copper top.
He is not using an electrician's back reading folding rule? Okay. I used to let those banana peelers and spiral cutters fall on the ground and just score it with a prep knife. After the 500th termination you have it dialed in pretty well. Heating that mess up with the weed burner make it lots easier to work with too. Aluminum oxidizes immediately when it contacts air. If you score into the insulation you can sand or file the scored part back smooth. My oldest stress cone tools are made like Vise Grips with a pull handle on one jaw and blades that cut a square cut and drag a parallel cut like the banana peelers. Those are some really OLD tools. They served me very well, if I bothered to use them.
You should press the lug on before you make the 6 7/8” measurement. That also is the only measurement that has to be precise. After you should use SAP tape from the jacket to the elbow before you connect the bleeder wire to eliminate the possibility of water getting into the elbow.
Work that looks good works good
You installed your silicone grease from your semi-con over the exposed insulation, if you were working for me, you would be cleaning that again and doing it over. Also, with a little a practice, and experience you can make all your scores and cuts with a sharp knife with more accuracy. When you ring cut the cable jacket, "break" the score with 2 hands and remove the jacket toward your butt cut and there is no need to worry about bird caging the concentric.
How do you make a solid ring cut in with the bananna peeler
Why not use a regular splicing knife, you don’t need all those fancy stripping tools.
Because I like using them.
Yes you do. Just try getting that semi-con off without the special tool. It is incredibly difficult.
@@ethanbrush4932 Not really, if you know how to use a knife.
@@jarredcorby7170 yes I know how to use a knife. Been doing this a long time. Maybe the semi-con you get is more cooperative. The stuff I get is extremely difficult to remove without the proper tool.
I agree 100%, faster and more accurate.
Hello, what chamfering tool is that? the one that is made for that cable alone?
Why wipe off the inhibitor? It's there for a reason.....
No robo presses? Wow. Do you use ratchet cutters still? And that’s xlp cable. That isn’t used anymore where I work.
What is the brand and part number for the pre-determined chamfer tool ?
To be honest I couldn’t tell ya sorry bud
Where did you get the chamfering tool at?
Excelencia y más
you work at abb?
comme chez nous en france
Checks out
Great video!! They are called Linesman pliers not Kleins. Klein makes them. Just busting balls.
They are called Klein's, 9's. and side cutter's. LOL
5:12 Don’t take off your PPE 😂
Pretty dangerous putting on some tape. 🤓
Whenever you start doing nonessential tasks for the sole purpose of aesthetics then you have strayed from the path of a competent installer. "Gee Bob, look how much time Mr. Smith wasted making this elbow look a certain way even though it made no difference in performance or safety." Good thing most linemen work for the public where they are not held accountable for their productivity.
Listen here Tommy… Real closely! I can’t terminate anything I’m sure faster than you with the highest quality of craftsmanship. I’ve been a lineman for 18 years dude and worked with them all. Number 1 is efficiency and second close is quality of work. I’m not cocky but a comment like this usually means you do really scab quality work.
Nonsense. A nice clean and orderly installation is important. Makes it easier to see what's going on and make changes or additions in the future. Imagine working with a rat's nest and checking things over.
Just a little hard to watch.
Then don’t
where are your PPE steel toe boots ?
I didn’t tell ya?
@@allanedmondson641 not once XD
@@SgtStarSlayer because it’s none ya damn business. 🤘🏻
@@allanedmondson641 lawls, when Osha says otherwise and shut that site down. You will moaning even harder.
Hold. The. Phone. HORIZONTALLY. For the love of god.
Vertical video is a sin. Repent...