HOW TO ADD R404A REFRIGERANT INTO UPRIGHT FREEZER

Поделиться
HTML-код
  • Опубликовано: 19 сен 2024
  • A step by step troubleshooting ice built up on evaporator and adding refrigerant is hereby detailed here and adjusting defrost settings of dixell digital control:👇
    R404A IDEAL CHARGING FOR COMMERCIAL REFRIGERATORS:
    CHILLER 30-40 PSI
    FREEZER 20-25 PSI
    COLD/COOL ROOM 20 PSI
    Idf - 3 hrs (defrost interval) change to 5 hrs
    Mdf-30 mins (lenght of defrost) change to 20mi
    #R404aRefrigerant
    #OCTTV
    #HVACR
    The author is a top notcher in Consumer Electronics and in Refrigeration and Air-conditioning, a certified welder (smaw),
    Auto diesel Mechanic, Cellular Phone Technician and an Experienced Computer Technician.
    My RAC tutorial videos:
    • Tutorials on Refrigera...
    My Dixell programming and pcb repairs:
    • Aircon & Refrigeration...
    My Basic electronics tutorials:
    • Basic electronics
    My photovoltaics solar tutorials:
    • PHOTOVOLTAIC SOLAR SYSTEM
    Funniest Comedy Videos
    • Playlist

Комментарии • 117

  • @masterangel1255
    @masterangel1255 2 года назад +1

    new subscriber ako sir malaking tulong ito para sa aming mga baguhan maraming salamat po

    • @THEMULTISKILLEDTECH
      @THEMULTISKILLEDTECH  2 года назад +1

      Your welcome po sir...Salamat sa Dios din po sa pag subscribe sa channel ko🥰

  • @hailuassefa
    @hailuassefa 2 года назад

    Clear and claver information

  • @joelbengco5344
    @joelbengco5344 2 года назад +2

    Sir, thank you for your very informative video. May I ask your help. I have a 4 door upright freezer with R404 refrigerant. I changed the filter dryer and capillary. I have another access valve before the filter dryer. Is it ok to charge liquid R404a before the filter dryer side or vapour on the low side? Thank you and more power.

    • @THEMULTISKILLEDTECH
      @THEMULTISKILLEDTECH  2 года назад +1

      Try it sir since that procedures are discussed in our refrigeration books. In walk in freezer/chiller we charge liquid in low side the reason is refrigerant goes easily into the system.

    • @joelbengco5344
      @joelbengco5344 2 года назад

      @@THEMULTISKILLEDTECH Thank you for the response sir. More power!

  • @John-yd5ve
    @John-yd5ve 6 месяцев назад

    ❤ thanks 😊

  • @JaykeSapalaran-iq3qs
    @JaykeSapalaran-iq3qs Год назад

    Great video information 👍❤ thank you for sharing your knowledge and experience 🫡🇵🇭

  • @wasiuadewale9781
    @wasiuadewale9781 Год назад

    Thanks a lot for your video. I want to ask if I can charge r404 to r22 compressor after changing the txv to 404.

    • @THEMULTISKILLEDTECH
      @THEMULTISKILLEDTECH  Год назад

      Yea sir can, just observe your txv. I've done that on our old walk in freeze lr w/o changing expansion valve and commercial refrigerator.

  • @jorgeLopez-xn9uy
    @jorgeLopez-xn9uy Год назад

    Great video. Question I have a freezer that calls for 24oz of r404a. Around what psi should a freezer be at.and do I need to charge in liquid or gas?

    • @THEMULTISKILLEDTECH
      @THEMULTISKILLEDTECH  Год назад +1

      18 - 25 psi sir, and don't charge it in liquid unless your unit is walk in freezer and the compressor is between 5 -20 ton

    • @jorgeLopez-xn9uy
      @jorgeLopez-xn9uy Год назад

      Thank you

    • @jorgeLopez-xn9uy
      @jorgeLopez-xn9uy Год назад

      ​@@THEMULTISKILLEDTECH thank you brother. Here an update I add the 24oz and it left me at 15psi the freezer got to the set temperature at -5 and shut down. I did notice a little frost built up once it hit -2° do you think I should add freon until it get to 18psi?

    • @THEMULTISKILLEDTECH
      @THEMULTISKILLEDTECH  Год назад

      Use clamp meter too sir and try to reach the rated amps stated to the freezer label. Is your unit operated by digital control ?

    • @jorgeLopez-xn9uy
      @jorgeLopez-xn9uy Год назад

      ​@@THEMULTISKILLEDTECH yes it a digital thermostat. Meter is reading 6amps

  • @tahiyya5913
    @tahiyya5913 Год назад

    Hello
    I changed the compressor of open door freezer..I charged the gas 404a up to 20..But the temperature not reaching below 7°c ..I need below 0..Can you please tell the actual problem..And let me know the actual running pressure of refrigerant r404a

    • @THEMULTISKILLEDTECH
      @THEMULTISKILLEDTECH  Год назад

      Can you tell me your setppint value in you digital control please?

  • @joshuarondero6105
    @joshuarondero6105 8 месяцев назад

    Hi good day sir Regarding on open Display meat chiller sa suction pressure same lang din po ba 25-40 psi and let be considered the ambient temperature of the area? Thank you in advance

    • @THEMULTISKILLEDTECH
      @THEMULTISKILLEDTECH  8 месяцев назад

      Best practice sir is follow manufacturer's recommendations sa unit nila. Mga chart available online are guides lang natin. May unit kaming r404a na 45, 60, 40, 25, 16 psi ang karga . Ang gulo di po ba? As what im saying, follow the manufacturer's recommendations

  • @adcruz5983
    @adcruz5983 9 месяцев назад

    Sir what is the problem of freezer compressor which has moisture/cold on the top of compressor. What is the solution?

    • @THEMULTISKILLEDTECH
      @THEMULTISKILLEDTECH  9 месяцев назад

      Are having an ice built on evaporator? If no, then its normal reaction

  • @John-yd5ve
    @John-yd5ve Год назад

    ❤🎉

  • @shahbakhtiar7607
    @shahbakhtiar7607 2 года назад

    Sir..i have question.i have a machine which is must go at least -30..but after change new compressor , filter drier and capillary..it only goes to -20...what should i check...im already increase the liquid r404a ..but it seem didnt work until frost on ..what should i check ? Low pressure only go to 10 psi..thanks

    • @THEMULTISKILLEDTECH
      @THEMULTISKILLEDTECH  2 года назад

      Try to add more refrigerant sir, just pay attention to your compressor amperage

  • @chuanshan3582
    @chuanshan3582 Год назад

    Hi Sir, if the refrigerator says R-404A 4lbs max, what psi should it be at? thank you!!!

    • @gabdgraieb
      @gabdgraieb Год назад

      Use subcooling and superheat reading🎉

  • @GorosaurusEditz
    @GorosaurusEditz 20 дней назад

    Sir pwdi ba mgVid ka mgRefill ng freon sa water dispenser?

    • @THEMULTISKILLEDTECH
      @THEMULTISKILLEDTECH  20 дней назад

      Sir wala po kasi kaming water dispenser, pero watch ka ng video kung paano magkarga ng 134a sa ref, same po yan sa water dispenser. Charge mo ng 6 psi lang. Sa mga bago unit ay wala pa po yang access valve, need lagyan at hanapin ang leak kung naubos na freon nya sir.

  • @anatalioambosjr1792
    @anatalioambosjr1792 2 года назад +1

    Hello sir, ask ko lang sana kung parehas lang ba ang karga ng 404a freon sa compressor na 1/2hp- 3/4hp, at 1 hp,at ilang psi charge sa low side ang minimum to maximum nya? Thanks

    • @THEMULTISKILLEDTECH
      @THEMULTISKILLEDTECH  2 года назад +2

      R404 between 20-25 psi lang sir for freezer. Pwede ka din magbase sa ampere sir, before ka magcharge check Muna run capacitor if less than 80% n ng value nya change na.
      If 1 HP change with 1 HP, if 3/4 HP, change with 3/4... Gaya ng sinabi ko sir base ka SA ampere at di ka maliligaw

    • @anatalioambosjr1792
      @anatalioambosjr1792 2 года назад

      @@THEMULTISKILLEDTECH thanks sir sa info. At sana madami pa kayong matulungan.

    • @THEMULTISKILLEDTECH
      @THEMULTISKILLEDTECH  2 года назад

      Sa label sir mayroon din pong nakalagay na kilograms ng refrigerant nya. If mayroon Kang timbangan use it sir.
      Welcome sir, update ka lng dito anytime sir.

    • @anatalioambosjr1792
      @anatalioambosjr1792 2 года назад

      @@THEMULTISKILLEDTECH thanks sir sa idea.

  • @JoyAlonzo-n5c
    @JoyAlonzo-n5c 7 месяцев назад

    Hi good day sir sa walk in chiller bitzer anu po tamang suction pressure 35psi to 40 psi po ba? Thanks in advance

    • @THEMULTISKILLEDTECH
      @THEMULTISKILLEDTECH  7 месяцев назад

      Mga bitzer namin sir is 20 psi lang, pero ginawang 30 ng mga kasama ko sir. Pero better contact mga supplier nyo for warranty purposes sir

  • @iwbsl196978i
    @iwbsl196978i 2 года назад

    In this video sir I see you charging 404 .
    This type of Freon it should be charging liquid case.
    Can you explain??

    • @THEMULTISKILLEDTECH
      @THEMULTISKILLEDTECH  2 года назад +2

      R410A should always in liquid charging, but for R404A not at all. In big system like cold rooms it needs to be charge in liquid for the reason of easily charging. But for small units like 4 door freezer, chest freezer .....no need.

    • @iwbsl196978i
      @iwbsl196978i 2 года назад

      @@THEMULTISKILLEDTECH thank you I appreciate it👌👍

    • @THEMULTISKILLEDTECH
      @THEMULTISKILLEDTECH  2 года назад +1

      Welcome sir, take note we are in tropical county, if you live in icy county please practice accordingly.

    • @iwbsl196978i
      @iwbsl196978i 2 года назад

      @@THEMULTISKILLEDTECH I live in Kuwait the temperature is 50 c😉

    • @THEMULTISKILLEDTECH
      @THEMULTISKILLEDTECH  2 года назад +1

      But you have winter there sir right? Ok sir thank you for visiting my channel.

  • @wasimedoo7994
    @wasimedoo7994 11 месяцев назад

    My friend the best explaintion but i am working know on a coller like that one it was working with r134 freon on some one change it in to 404a compressor the system have a capillary i put in 25 to 30 psig of 404a an it not working the way it should can you give me some advice please god bless 👍

    • @THEMULTISKILLEDTECH
      @THEMULTISKILLEDTECH  11 месяцев назад

      You should replace the compressor oil my friend

    • @wasimedoo7994
      @wasimedoo7994 11 месяцев назад

      The compressor change 134a to 404a

  • @trending4you612
    @trending4you612 2 года назад

    Sir I have a question.
    I have a refrigerator which is horizontal laying down with 3 doors in silver metallic body
    And in this gas is 404a I charged gas and its working good but becoming very hot after some and because of over load stops working
    Plzzz tell how much gas i should charge at how much amps so the compressor will not get hot any more and cooling also be good
    And I need temperature of that chiller from +1 to +3 range
    Plz

    • @THEMULTISKILLEDTECH
      @THEMULTISKILLEDTECH  2 года назад

      Is your 3door chiller still have label sir? If so, a refrigerant in kilograms is stated therein. Over charging makes your compressor overheat and the overload will cut off the power to protect it.
      In my description I write there our R404A charging pressure and our units are for commercial use.

    • @trending4you612
      @trending4you612 2 года назад

      @@THEMULTISKILLEDTECH yes sir there is label

  • @AM-gi2ol
    @AM-gi2ol 2 года назад

    This refrigerant 404a charging for lliquid or vapour

    • @THEMULTISKILLEDTECH
      @THEMULTISKILLEDTECH  2 года назад

      Vapor sir if refrigerators, liquid if walk in.

    • @kwiz8848
      @kwiz8848 2 года назад

      I thought in every case you would charge as liquid? As 404a is blend of different refrigerants

  • @rafamirtech8920
    @rafamirtech8920 Год назад

    Can R404 be replaced with R134?

    • @THEMULTISKILLEDTECH
      @THEMULTISKILLEDTECH  Год назад

      Compressor 134a replace with 404a compressor can sir

    • @rafamirtech8920
      @rafamirtech8920 Год назад

      @@THEMULTISKILLEDTECH If refrigerant R404 is filled with refrigerant R134, can it or not, sir?

    • @THEMULTISKILLEDTECH
      @THEMULTISKILLEDTECH  Год назад

      We can't mix 2 types of refrigerant at the same time sir.

  • @blingmotions6996
    @blingmotions6996 10 месяцев назад

    Why didn't we use liquid from the 404a tank

    • @THEMULTISKILLEDTECH
      @THEMULTISKILLEDTECH  10 месяцев назад

      Don't refill if compressor is running, compressor pumps vapor not liquid.

    • @blingmotions6996
      @blingmotions6996 10 месяцев назад

      So if it's a walkin freezer it could happen but a upright fridge no?

    • @THEMULTISKILLEDTECH
      @THEMULTISKILLEDTECH  10 месяцев назад +1

      @@blingmotions6996 You can do liquid charging as long as compressor is in off mode. For both upright and cold room. Top up in walk in freezer using vapor is, it takes time ( R22, 234a .. vapor charging; R404a ... liquid charging) what ever freon you use, do it in liquid charging

    • @blingmotions6996
      @blingmotions6996 10 месяцев назад

      @@THEMULTISKILLEDTECH
      Ok thanks

  • @melvinlabog8081
    @melvinlabog8081 3 года назад +1

    sir may tanong lng ako anon po ba standard psi sa 404a

    • @THEMULTISKILLEDTECH
      @THEMULTISKILLEDTECH  3 года назад

      Freezer po is 20-25 psi,
      Chiller po is 30-40 psi, commercial refrigerators po Ang mga iyan sir. Mayroon kami walk in freezer bitzer compressor 20 psi lng, meron Naman Electrolux walk in chiller design for 60 psi pag ginawa mong 45 psi nagyeyelo evaporator nya sir

  • @felixZ143
    @felixZ143 2 года назад

    Sir can i ask all of my unit is walk in freezer... At McDonald's 404a refrigerant..
    What is the advantages and disadvantages if i recharge it in liquid lowside and gas lowside sir.. thank you very much sir...

    • @THEMULTISKILLEDTECH
      @THEMULTISKILLEDTECH  2 года назад +1

      For walk in freezer sir charge it with liquid in low side, if gas charging it will not go into the system. No advantage and disadvantages sir. Its normal that's what we do

    • @felixZ143
      @felixZ143 2 года назад

      @@THEMULTISKILLEDTECH thank you so much sir... Now i know...

    • @felixZ143
      @felixZ143 2 года назад

      @@THEMULTISKILLEDTECH sir.. did walk in freezer and cabenet freezer.. has a deferent standard pressure or it still the same sir..? Like compressor horizontal and compressor vertical... Thank you sir..

    • @THEMULTISKILLEDTECH
      @THEMULTISKILLEDTECH  2 года назад +1

      R404a pressure for walk in freezer/chiller sir is 20 psi bitzer compressor sir. Cabinet or upright freezer pressure is between 20-25 psi sir.

    • @felixZ143
      @felixZ143 2 года назад

      @@THEMULTISKILLEDTECH Sir sorry i have a lot of questions just a beginner.. sir..
      When compressor running the pressure lowside is 25psi when it reach positive 3F° it drops to 14psi.. it is normal sir or not..?

  • @ahmad78ist
    @ahmad78ist 2 года назад

    kapag reach in freezer sir prehas lang din ng pressure para s r40a

  • @rahimahmad1563
    @rahimahmad1563 Год назад

    Can i convert gas r404 to r134a into compressor r404?

    • @THEMULTISKILLEDTECH
      @THEMULTISKILLEDTECH  Год назад

      Yes but bear in mind that 134a suit for medium/high temperature such as chiller while r404a for low temperature like freezer

    • @rahimahmad1563
      @rahimahmad1563 Год назад

      Means for upright freezer r134a are not suitable to used ?

    • @THEMULTISKILLEDTECH
      @THEMULTISKILLEDTECH  Год назад

      For commercial yes but for chest freezer on issue

  • @ryancaspillo7715
    @ryancaspillo7715 7 месяцев назад

    Hi Sir. Tanong ko lang sa cascade po na machine need ko po kase ng negative 75 degree celcius paano ko po kaya marereach yun

    • @THEMULTISKILLEDTECH
      @THEMULTISKILLEDTECH  7 месяцев назад

      Better contact mo supplier nya sir

    • @THEMULTISKILLEDTECH
      @THEMULTISKILLEDTECH  7 месяцев назад

      Try mo 16 psi at gawin mong -75 ang set point mo then watch mo ito sir 👇👇👇 kung dixell xr60cx ang controller mo ruclips.net/video/AXenafBcrzU/видео.htmlsi=FrfpULVIEgmkPV-8

  • @mariafernandez7337
    @mariafernandez7337 Год назад

    Sir Tanung lang ako kung magkano ang tamang psi sa R404 sa Walk-In Freezer

  • @sintiania4339
    @sintiania4339 2 года назад

    Good day sir, upright freezer 404a Hindi cia lumamig nakusulat sa specs. Amp. 3.5 amp. Charge ako ng 25 psi NASA 11°C temperature, Hindi lumamig tapos umiit compressor, ano Po ung purpose ng solinoid valve thanks po

    • @THEMULTISKILLEDTECH
      @THEMULTISKILLEDTECH  2 года назад +1

      Ang purpose nya is on and off nya po refrigerant flowing at ang supply nya is from compressor. If aandar ang compressor dapat magoopen Naman solenoid mo sir at pag nag off compressor dapat off din.

    • @THEMULTISKILLEDTECH
      @THEMULTISKILLEDTECH  2 года назад

      If good solenoid check mo run capacitor, filter drier, at expansion valve sir

  • @saturninoiiisaban3016
    @saturninoiiisaban3016 Месяц назад

    Sir pwede pa tulong ganyan din po ang problem ng freezer namin.
    Paano kita ma contact sir salamat😊

    • @THEMULTISKILLEDTECH
      @THEMULTISKILLEDTECH  Месяц назад +1

      Comment down lang ng tanong nyo sir. Di na ako naglalagay ng Cp number sa kadahilanang pati ibang lahi natawag. Buti sana kung di na kami nag tatrabaho sir, OFW po. After work mamalengke, luto, laba, video chat sa family, at vlog para may extra barya....Sana naunawan nyo po

  • @sherwinmirando3766
    @sherwinmirando3766 2 года назад

    Sir Kung Ang ref ko ay 134a gas at nag charge po ako at kinulang pwdi po mag add Ng 10/.percent na charge Ng 404 refrigerant gas

    • @THEMULTISKILLEDTECH
      @THEMULTISKILLEDTECH  2 года назад

      Di po pwede maghalo ang refrigerant sir. Bili na lng po kayo ng r134a

  • @yhanatv6184
    @yhanatv6184 8 месяцев назад

    Sir magkano mag pakabit ng freon

    • @THEMULTISKILLEDTECH
      @THEMULTISKILLEDTECH  8 месяцев назад

      Di po ako updated Philippines price, ofw now. Kung top up lang per kilo po yan, much better if hanapin po muna leak

  • @alembattlerealmsgamefowl6631
    @alembattlerealmsgamefowl6631 2 года назад

    gud am/pm sir tanung lang poh anu poh suction pressure ng 404a ,upright freezer rated current 3.7 amp, nagcharge na poh ako 26 psig ,ampere nya 3.3 amp palang at temperature nasa -1°c palang for 30 minutes na umaandar ,please reply thank anu tamang charges at ampere

    • @THEMULTISKILLEDTECH
      @THEMULTISKILLEDTECH  2 года назад +1

      Max nya 30 psi kabayan pero stay ka lang Muna sa 25 psi. Dapat 2 hours -18 and above kana

    • @alembattlerealmsgamefowl6631
      @alembattlerealmsgamefowl6631 2 года назад

      @@THEMULTISKILLEDTECH bagong palit poh ako ng filter at starting capacitor na 80mf ,nalinis narin system ,,charging nya poh ngyon is 25pisg ampere is 3.5 amp nah temperature nya -10 c 40 minutes

    • @THEMULTISKILLEDTECH
      @THEMULTISKILLEDTECH  2 года назад +1

      Check mo na din run cap sir

    • @alembattlerealmsgamefowl6631
      @alembattlerealmsgamefowl6631 2 года назад +1

      @@THEMULTISKILLEDTECH same poh bagong palit ng capacitor 80mf at isa 10mf ,bago na poh pagka hindi poh bumaba ng -18 in 2 hours ,pwede na isagad 30 psi charge ? ,unang beses ko kasi mag charges ng 404a ,, lagi kami Ammonia at r22 410 407 s mga Aircon unit ,

    • @THEMULTISKILLEDTECH
      @THEMULTISKILLEDTECH  2 года назад +1

      Bababa pa yan sir....wag po isagad kawawa si compressor. Kami babalikan din namin mayamaya kapapalit lng compressor ng combination freezer and chiller. Dito Muna kami ibang issue

  • @aiahamadumbayo7475
    @aiahamadumbayo7475 Год назад

    Sir what is the actual pressure for R404A

    • @THEMULTISKILLEDTECH
      @THEMULTISKILLEDTECH  Год назад +1

      Actual is stated in manufacturer's label stated in kilograms. R404a charging chart are only our references sir.