Sir ek video bnaiye sac , sba aur mb pe....jisme sb detail se explanation ho...resin k bare me bhi aur reaction k baare me bhi aur outlet water parameter k baare me bhi....regeneration k baare me bhi....
Good morning Sir mera question hai Acf ki media kab change karna chahiye Mera drinking water ka ro plant hai Acf ke inlet me 1ppm clorine value & ACF outlet me 0.8 ppm clorine value to media change karna chahiye ya nahi
Sir, please iron filer ke mechanism aur uske media cleaning process pe ek video banaiye. Bulk level pe. Hamaare Jharkhand me villege me bahut saara laga hai, bt koi servicing abhi tk nahi ho paayi hai.
Pable size & level ok I understand but vesal size kya hona chaye ? size aur design ke according media feeling hoti he jitna muje pata he. & OBR kya hota he ? please do need full 🙂
Sir aapka bhut bhut dhanyawad
Ki aap itni informative vedeos banate ho
Sir apki video se bahut help mil rahe h knowledge k liye
You are super teacher in power plant
Aapke Next class ka besabri se intzaar rehega sir
Excellent Bhai, Simply Superb. You are one of the reason I cleared my BOE Exam. Love You Bro
Congratulations dear
Very helpful vedio
Sir ek video bnaiye sac , sba aur mb pe....jisme sb detail se explanation ho...resin k bare me bhi aur reaction k baare me bhi aur outlet water parameter k baare me bhi....regeneration k baare me bhi....
Chandan Sir , ur video helps me lot, Thank u sir
Lovely sir ji
Very good suggestion
Informative video hai sir 🤗🥰
Great sir
Bahut achha sir
Good morning ji 🙏 thank u so Mach
Best post
Fantastic video
Great. Thank you very much for your video.
Sir very very Good sir ji
आपके पास D. M. प्लांट है सर?
Thank u sir Nice explanation 🙏🙏
Well explain sir .....
Sir ap ki sabhi vedio best he but Sir se request he ki ap jaldi hi icx digester se sambandhit vedio bheje
Sir cartridge filter ke bare me bhi btaiye ye kis type ki impurities ko remove krta h
Mast sir ji
Nice information, dual media filter & pressure sand filter var video banava, I am waiting
Sure I'll upload soon
Thanks sir nice sharing👍👍👍
Nice 👍
Make video on chilling plant .. ammonia as a refrigent
Sure I'll make
Sir chiller system pr v jankari de please 🙏🙏🙏🙏🙏
Sure dear I'll make
Best explanation ever 👍👍
Bhai backwashing aur rinsing procedure aur kitne time par kiya jata hai ispar bhi vedio banaye
DMF per bhi vidio banaiye sir..
Corbon ki id kya hoti hai kya tds kam hone par kam id ka corbon use karna chahiye veodio plz
U r so great sir 🙏👌🙏
Sir welding, bearing ,coupling, shaft alignment ka details with symbols ka video banaiyega sir please
Sure I'll make
@@PowerPlantDiscussion thank you sir you are great teacher
Pls make video on vapour compression refrigeration system
Sure
Thanks sir🙏🙏🙏
Good morning Sir mera question hai Acf ki media kab change karna chahiye
Mera drinking water ka ro plant hai Acf ke inlet me 1ppm clorine value & ACF outlet me 0.8 ppm clorine value to media change karna chahiye ya nahi
Anaya oru katione mein se donon koi ak discharge Ho jaaye to kya hoga
Sir, please iron filer ke mechanism aur uske media cleaning process pe ek video banaiye. Bulk level pe. Hamaare Jharkhand me villege me bahut saara laga hai, bt koi servicing abhi tk nahi ho paayi hai.
Sir please ak Daf process ke bare me video bana dijiye
Daf working principle kya h bata dijiye
Sir ekbar chlorination ke bare me btaye sir
Link provided in description
#THANKS
Sir ek bar acf filter installed ho gya uske baad uska carbon kitne din tk active rhta hai?? Backwash krne se acf ka poures clear ho jaata hai kya?
Ha
Sir MB ki bare me ek video banaye.
Sure dear I'll make
RO plant me energy recovery devices PX and tarbo ka workings principal please sir
Nice explanation 👌
Nice sir ji
Sir I'm work in DM plant... In our plant pressure sand filter install after acti flo and psf outlet is UF inlet
Nice
Sir turbine ko start krne se pahle heating kyo krte h
If turbine starsts directly then what happened
May be thermal shock can damage. That is why we preheat.
Sir aage ki video kb banayenge agr video banaye hi to mil.nhi rha hai
Sir, 50 m3/hr ka side stream filter bnana hai. Kese banaye kripya calculation bataaye 🙏🏻🙏🏻🙏🏻
Pable size & level ok I understand but vesal size kya hona chaye ? size aur design ke according media feeling hoti he jitna muje pata he. & OBR kya hota he ? please do need full 🙂
Sir... ye sab equipment jo sab organic impurities ko remove karenge, iska used ka remaining time kya hota hai...
Sir, kaise samjhenge mgf, acf ,dmf ka media change karna hya
Sir power plant job available ke baare me bhi bataiye
Or videos banao sir DM plant par
Yes
....we want to know more
Sir activated carbon filter ka density kya hota hai please answer me..?
Pahle to send filter aaega na Sar uska process bataiye
Dear sir
CPU ke bare main jankari chahiye
CPU ka resin transfer ke bare bhi bataiye
Very soon I'll make on CPU please wait for the video
excellent explanation. need your help on mixed bed ion exchangers . if u have a presentation then please forward me the link
Digester me VFA control kese karte he
Backwash and rinse ka time pe ACF se air knue nikala jata hai??
Kya?
Please explain tubesettler
Plz tell about degree of super heat
Temperature above saturation
Activated carbon ki iodine value kitani hoti hai sir?
500 to 1000
Sir , very Good video .
One question.
For 1 m3 per water flow rate , how can we calculate the amount of carbon.
Volume of tank : 1m3 .
Please.
Sir how to know ACF is not working properly.. and needs treatment.. pls
Check FRC at outlet of ACF
@@PowerPlantDiscussion what it means .. free chlorine in outlet.. how much FRC limit is acceptable... Pls
In Which playlist is this lecture added?? I can not find this lecture in any playlist....plz confirm...
How to calculate ACF capacity and activated carbon?
Please sir discussion it.
Advance thanks to you
Sir how much carbon to filled in filter give example plz with numbers
beg filtr penal ko chalane ke smjaye
Activated carbon filter increase condensate parameter what is the problem
Sludge volume kese brhate he
Pahle send filter per A9 cricket9 FIR mix bed
Sir cpu ka video banao plz
Dear are talking about condensate polishing unit
Yes sir condensate polishing unit mai resign transfer kaise karte hai
Sure dear I'll make for this topic
U r stunning
Please sir mixed bed vedio make
Vader Condensat kya he
Vafer
Ebct?
Acf outlet Drinking water
Bhai address milega aapka
Please sir Jagdish bheje
Agar kisko ya pant cahiye to mere commet pr kare
Bhai koi contact number mil skta h mje class leni h apse
Number mil jaaye aapka
Contact me powerplantdiscussion@gmail.com
गुजराती में समझाओ गुजराती गुजराती भाषा में समझाओ
Bhakt
Sacendry clarifier kese kam karta he