Sir thank u so much for this kind of vidio on drives......your explanation is very clean and easy to understand......specially i like to listen "theeek hai n" from u after every sent.....😍😍😍😍😍......nd sir plz make a vidio on master slave drive configuration......how we can operate two drive as master slave .......once agian thankxxxx......
Sir my ABB 550 drive take a lot of time for start and stop ..tell me parameter for rectification..is this problem on acceleration and deacceleration time
Undervoltage during deceleration may be due to excessive braking current if DC braking is used or dynamic braking parameters are not set properly.if parameters are okay then there may be problem in braking IGBT of DBR.
Sir my 250 kw ABB ACS-850 Drive is tripping on DC over voltage on every minor voltage flauctuation. What is parameter for auto restart for ABB acs 850 ? Even others sinamics vfds of same rating doesn't tripped.
drive me 2.acceleration time rahta hai use jab chaho select kar sakte ho ek digital input deke ya plc se digital input deke bhi.application k according selection kar sakte hain.
DC BUS OVERVOLTAGE NICE EXPLAIN
Thanks sir 🙏
Bahut badiya samjaya
Nice explain sir ji
Nice video sir is video s muje bhut fault clear hu h thanks
thanks for watching, keep in touch brother
Very good information in this video sir
Superb teaching.
Superb explanation sir.
thanks surendra
It’s really use full content thanks you 👍
Sir servo motor explain karo ,, position accuracy kaise achieve karte hai and usme acceleeation time jyada hota hai yo kya effect hota hai position pe
goooooooooooood and niceeeeeeeeeeeeeeeeeeeeeeeeeee.
Well done sir....I understood
thanks and watch all the videos they'll be helpful for you
@@aforautomation yes sir
very good video. Much appreciated .Thik hai na 50 times
Hahaha. thanks brother
Sir please make a video of harmonics and why we use more 6, 12 or 24 pulse drive
Sir, can you please make a video about of regeneration braking
nice bro
Thanks sir. push battom se friquency slowly and firstly com jada kayse karsakta hey
Push button se 2 DI connect karo aur DI k function me MOP inc aur decrease set karo, speed reference source ko terminal set karo,ho jayega
Sir,Good explanation
Esa drive ke bare me or parameters ke bare me or vi topic me video banaiye plz
Good job sir
Thanks
Thanks Sir 👍
Sir thank u so much for this kind of vidio on drives......your explanation is very clean and easy to understand......specially i like to listen "theeek hai n" from u after every sent.....😍😍😍😍😍......nd sir plz make a vidio on master slave drive configuration......how we can operate two drive as master slave .......once agian thankxxxx......
😁😊😊 welcome brother
Voltage increase karenge toh current increase hoga ,and speed achived hoga toh current Kam kaise hot hai ??
Sir our drive tripping of crane application DC link overvoltage..we have applied dbr unit ..still sometime
increase de-acceleration time or tune motor with drive.You can use DC braking for better performance.
Sir my ABB 550 drive take a lot of time for start and stop ..tell me parameter for rectification..is this problem on acceleration and deacceleration time
yes its due to Acceleration and deceleration time but if you reduce time DBR will be required otherwise drive will trip on overvoltage fault.
Thanks for the brilliant video. What is the cause undervoltage during deceleration..
Undervoltage during deceleration may be due to excessive braking current if DC braking is used or dynamic braking parameters are not set properly.if parameters are okay then there may be problem in braking IGBT of DBR.
Sir my 250 kw ABB ACS-850 Drive is tripping on DC over voltage on every minor voltage flauctuation. What is parameter for auto restart for ABB acs 850 ? Even others sinamics vfds of same rating doesn't tripped.
Have you connected brake resistor to drive if yes then enable par 48.01.
if not then enable par 47.01
to auto reset the overvoltage fault bit number 1 of par 32.01 shoul be 1
Sir please abb dvire ki parameter ke manual per video upload karna jaise kaise number me kaisa perameter set Kiya jata hai
okay i will make
nice explanation
V good sir
Sir thank you so much
Nice
thanks brother. please view all videos they'll help you.
please share with your friends who need this type of videos.
if english subtitle, then i think your video will be see many many people
Sir please give us a class of scalar mode vs dtc mode of a drive.
next video will be vector control concept
A For Automation ok..sir
Sir drive mein two or more aacleration and deceleration time q diya rehta hai
drive me 2.acceleration time rahta hai use jab chaho select kar sakte ho ek digital input deke ya plc se digital input deke bhi.application k according selection kar sakte hain.
Sir vfd me lvd and lva error atta he how to solve
kon sa drive hai?
Vfd cx
AC drive
Sir kindle help us in translation to English
V/f value in drive
Nice