Split AC Installation Guide|| Ac को लगाने का तरीका। LG 1.5 TON 5 STAR DUAL INVERTER AC

Поделиться
HTML-код
  • Опубликовано: 28 ноя 2024

Комментарии • 768

  • @Ranjan.75_adda
    @Ranjan.75_adda Месяц назад +3

    Bahut hi achcha video tha
    Bina bakwas ke aapane sidha kam ka baat bataya
    Thank you😊

  • @kk86869
    @kk86869 Год назад +11

    Thank you bhai mere 1200 rs bacha liye Aapne instillation charge

  • @Dil43STL
    @Dil43STL Год назад +8

    Bahut hi Accha samjha te hai koi bhi samajh jayega Very Happy

  • @khajawasiuddin9885
    @khajawasiuddin9885 2 года назад +41

    Jab Outdoor ooper lagana ho toh .
    Indoor ka pipe baahar se seedhe ooper na len.1 fit left ya Right ko mod de.thoda neeche ki taraf rakhe or Outdoor ko connect karen.Baarish ka paani pipe ke zariye andar nahi aayega.
    Or baahar se white cement lagaakar hole bhi band karden..
    Gas reliese karne se pahle achi tarha valcume karen.(Approx 15..to..20 minut )

    • @zahidtechmech1013
      @zahidtechmech1013 2 года назад

      Vacuum kitne pressure par karte hai?

    • @rajtera3103
      @rajtera3103 Год назад +1

      Bhai LG ke ac achhe hote hai kya cooling thik krte hai kya and durable hai ya nhi

    • @chesta197
      @chesta197 Год назад

      ​@@rajtera3103 Daikin ac best window lo ya fir spilt

    • @mazharkhan8189
      @mazharkhan8189 Год назад +1

      Right bahar direct connector nhi nikalna chahiye kyun waale bande ka mood kharab ho jaaye agar lequage hoga to cooling coil ka kaam hua to😂😂😂😂

  • @MohsinShaikh-yo7bw
    @MohsinShaikh-yo7bw Год назад +4

    Ji Aap ne kaam to kiya lekin proper tarike se neahi kiya conection bahar nikal diye or teping bhi proper karni thi or men Vaccum ❤

  • @Vivektechnician
    @Vivektechnician 2 месяца назад +3

    Thanks for 280 subscribers complete ❤🙏

  • @bonishkhan6931
    @bonishkhan6931 Год назад +3

    Me to Panasonic ac installation karta hu but pyaar se samjhya logo thanks 🥰

    • @Stoicbaba
      @Stoicbaba 8 месяцев назад

      Plz ye batao agar direct peeche hole na karna ho toh kya ghumaake duur lejaake hole possible hai

    • @rukshanakhatoon8314
      @rukshanakhatoon8314 3 месяца назад

      TECNECIAN se bat kare kripya karke you tube univercity se kam badhaye kare​@@Stoicbaba

  • @thehawk...bijannandi2640
    @thehawk...bijannandi2640 Год назад +1

    Great... installation....I like it...and also hope your next installation and mervelous technique....

  • @vjsoni3344
    @vjsoni3344 2 года назад +14

    Earth wire is very important
    And vaqqum जरूरी h

    • @rajtera3103
      @rajtera3103 Год назад +1

      Vacuum hoti kaise hai pipe me

  • @biswas7773
    @biswas7773 2 года назад +24

    No tapeloon, no vacuum, no earthing, leakage check at 50psi
    Who are you?

    • @rvaircon
      @rvaircon 2 года назад +2

      50 KA PLEASURE dal Kar usko Vacuum bhi nahi Kiya,Kam se Kam flush Vacuum to Kar lete.
      New Installation Mai Pressure Dalnai ki sayad tumhe jarurat nahi padni chahiye, Jab tumahari paas Completely Sab kuch nya ho.
      In bhai sahab ko Working conditions mai dena tha kya keval, Jo ho gya.

    • @rohitchopra8911
      @rohitchopra8911 2 года назад

      Inho ne sasti traning le h 😂

    • @AkashKumar4u
      @AkashKumar4u 2 года назад

      Jaahil installer and misleading RUclipsr. Yahi hota hai India me. Vaccuming & earthing is very important.

  • @devilmichael01
    @devilmichael01 Год назад +2

    I am also AC technician
    Single phase ,three phase and package AC alrounder ❤

  • @ganeshrajput7756
    @ganeshrajput7756 2 года назад +2

    Good moring bhaiya

  • @taufiqkhan9250
    @taufiqkhan9250 3 месяца назад

    Very nice video bhai 👍😄👍😄👍👍😊😊❤❤❤

  • @sinvlogs1
    @sinvlogs1 Год назад +5

    green wire very important bhai.... vo earthing ke kam me ati hai.... Bijali ke jhatse bachati hai usko bhi lagado bhai

  • @satyaprakashsahu1604
    @satyaprakashsahu1604 2 года назад +2

    Good video dear sir all the best thank you so much.

  • @mdfarhanraza7279
    @mdfarhanraza7279 Год назад

    Aur ha sir aap ko mahngi lagegi kaam lekin kaam good hoga aur aap happy honge aur me company se is liye kah rha hu ac lagwane ko kiu ke aap ki ac agr demege nikla ya fhir koyi bhi issu ho use hm return karwa sakte hai but aap ka ac agr bahr wala lagata hai to oo garanty nahi lega me parsonal bhi kaam karta hu kabhi karwa ke dekhna bro ok thankyou somch

  • @himanshubhandari3751
    @himanshubhandari3751 2 года назад +31

    We need to vaccum it first for better and long run cooling without gas problem. Then release the gas from outdoor unit ...

  • @Nx_blaster_gaming
    @Nx_blaster_gaming 5 месяцев назад

    Achha hua bhai tera video ekha to ab ac thik se laga dunga varna itne din mene sahi ac lagaye hi nahi

  • @asu54874
    @asu54874 2 года назад +2

    10 min. Me installation, tum hi kr skte ho bhai, well done👍.

    • @Sigma.com07
      @Sigma.com07 2 года назад +5

      kam se kam 2 se 3 ghante lagte hai bhai

    • @a.k.birdsbusiness7
      @a.k.birdsbusiness7 7 месяцев назад

      10 min me Sikh jaoge bola h na installation ka

  • @learnme7312
    @learnme7312 Год назад

    Congratulations 🎉🎉🎉

  • @SantoshHajara-en3fc
    @SantoshHajara-en3fc Месяц назад

    Bhahut Bariaa

  • @ranajitmallick3154
    @ranajitmallick3154 10 месяцев назад +1

    1. Pipe direct bahar nehi nikal na chahiye, pipe hamesha left se hoke jayega agar akdam jaga nehi hai to hi aisa karna chahiye, technician shortcut mar diya,
    2.pipe bahar nikalne ke bad thora sa niche u band hoke phir upar utna chiye,is se barish ka pani ander jane ka change 99% kam ho jate hai ,
    3. Vacuum is absolutely necessary, with vacuum apka ac ka cooling 5 to 10% kam ho jata hai,
    4.ap ko kisne bataya ki green wire ki kohi kam nehi,

  • @anzalkhan0012
    @anzalkhan0012 Год назад

    Bhout achha video bro❤

  • @lancydsouza1326
    @lancydsouza1326 2 года назад +1

    Jo supply cable mein se yellow/green (ground) wire tumne katke fenkdiya, bahut badiya baat hai. Jisne bhi lagaya tha, ek number ka gadha tha. Vacuum bolne ki cheez tumhare dictionary mein tho hai nahin. Bahut badiya seekhne ko mila tumse. Aage ki santan ko bahut acha sikha rahe ho.

  • @Asr129
    @Asr129 Год назад

    Iska outdoor part stairs k neeche laga sakte h jo ki room se bahar hai, kyuki ghar ke chaaro side koi jagah nahi chhora gya hai, main gate bhi 3 ft open h only jo ki 90 ft packed gali hai with no proper sunlight

  • @islamunstoppable2204
    @islamunstoppable2204 Год назад +1

    Indoor ka stand fit krne ke liye jo hole kiye jate hain wo kitne no. Ki bit se kiye jate hain ?

  • @RizwanKhan-tg3xq
    @RizwanKhan-tg3xq 11 месяцев назад

    Nice information👍

  • @MdIrfan-ez3wb
    @MdIrfan-ez3wb Год назад

    So beautiful video

  • @newgilltruckbodypatran
    @newgilltruckbodypatran 2 года назад +22

    Bhai agar leakage hogi v to 50 ke pressure pe samne nai ayegi,kam se kam 200 ke pressure pe samne ayegi,koi faida nai 50 pe check karne ka

    • @Abdul-u3l9c
      @Abdul-u3l9c 2 года назад +2

      hame 110 ke pressure. pe chaik karte hai

    • @Mr.bd_HVAC
      @Mr.bd_HVAC 2 года назад +2

      Mea compressor k jarye 250 psi par lick check karte hai

    • @gkairconditioner9858
      @gkairconditioner9858 2 года назад +2

      Hame450 psi pr check krte hai

    • @Friendscoolingsystemjasola
      @Friendscoolingsystemjasola 2 года назад +2

      Bhai likiz 10 pr bhi dikti h phle usko bdiya se heet kr lo fir saaf krke chek kro kitni bhi choti likiz ho khud dikh jayegi aur zyda tr zyda srf ka use kro pani chikhna hona chahiye ok bro

    • @jakirhusain5610
      @jakirhusain5610 2 года назад

      Use ye to pta nhi pipe ka size kya h.wo bolra mota mote me ptla ptle me 🤣🤣🤣

  • @gajendrasinghchoudhary4460
    @gajendrasinghchoudhary4460 Год назад

    10 by 5 ki gallary hai 11.50 feet height hai usme ek outdoor and ek cooler laga hua hai..cooler ki cooling affect hogi

  • @hem5647
    @hem5647 4 месяца назад

    bhai tum uttrakhand se ho kya?

  • @bawababbar4857
    @bawababbar4857 11 месяцев назад

    superb bro

  • @ranjansinha5119
    @ranjansinha5119 Год назад

    Great video

  • @heerkamalsingh9
    @heerkamalsingh9 8 месяцев назад

    Bro im mechanic we install ac in 1 hour 👏

  • @manoharnagdev1616
    @manoharnagdev1616 Год назад +1

    Only काम कि बात no bkwass...!!! 👍👍👍

  • @Mikekl5778
    @Mikekl5778 8 месяцев назад

    Hello sir.. Really need help from u. Lg technician came and service my split lg ac but afterward the water from drain pipe stopped coming and even my outdoor unit fan got jam. Is it possible the technician has spoiled my Ac. Kindly need ur advice on this.

  • @rakeshdey9056
    @rakeshdey9056 Год назад +3

    Green wire is for earthing it's important

  • @SunilKumar-rk8st
    @SunilKumar-rk8st 2 года назад +154

    Brother I m a technician 10 mint me ac install.... impossible

    • @VISHALKUMAR-gk6qr
      @VISHALKUMAR-gk6qr 2 года назад +16

      He said you learn in 10 mint . That how to install split

    • @VinodKumar-ri3qf
      @VinodKumar-ri3qf 2 года назад +5

      Vedo hai forward fast edit hai

    • @mohdzaki8362
      @mohdzaki8362 2 года назад +3

      Ya bro agar pakki eat ki diwaar aa gayi to 15 min to hole hi me maan lo
      Baaki customer ko demo dekar pura satisfied karna

    • @amirpubgkamina9410
      @amirpubgkamina9410 Год назад

      Yes impossibal 👍

    • @amirpubgkamina9410
      @amirpubgkamina9410 Год назад

      @@krushnarajsinhlimbola4544 hai.!

  • @MuhammadSaboor
    @MuhammadSaboor Год назад +2

    صلی اللہ علیہ وآلہ وسلمI LOVE ALLAH AND RASOOL S.W THE PROPHET MUHAMMAD S.W THE LAST NABI OF ALLAH KIYA AJ APNE HAZRAT MUHAMMAD S.W PR DAROOD E PAK PARHA ?

    • @maheshpawar9281
      @maheshpawar9281 6 месяцев назад

      बीच में ये क्या है बे

  • @comedy11651
    @comedy11651 6 месяцев назад

    Thank u sar thankyou thankyou thankyou

  • @vivekshisave8312
    @vivekshisave8312 4 месяца назад

    बगर व्याक्युम के बगर ही एसी इन्स्टॉलेशन करते हो क्या

  • @Surajbisht_
    @Surajbisht_ Год назад

    Kya kya samaan lgta h ac install k liye ...jaise stand , pipe aur ..?

  • @jugalkr.pandey
    @jugalkr.pandey 2 года назад +1

    System ko ground karay naki Earth wali wire ko cut karay

  • @palshantanu1993
    @palshantanu1993 2 года назад +6

    This is not an AC fitting method
    What was needed was to tighten the nut on the outside. It would have been better to do it on the inside. The inverter did not vacuum the AC and did not apply the wrapper tape to take it home.

  • @SakirBabu-xn6vy
    @SakirBabu-xn6vy 8 месяцев назад +1

    Ac ka kam sikate samay kitna rupya dete hai guru ji

    • @Trickriyxn
      @Trickriyxn Месяц назад

      Koye paise nhi lgte ulta paise milege helper bankr jao ac wale ke sath

  • @Masleuddin312
    @Masleuddin312 10 месяцев назад

    Supar bhai

    • @NavinKumar-vl2xk
      @NavinKumar-vl2xk 6 месяцев назад

      क्या सुपर है बिना वैक्यूम किये इंस्टाल किया गया ,बहुत कमी है इसमें

  • @harpreetsaini4933
    @harpreetsaini4933 Год назад

    Bhai brazing is best than flair nut & teflon tape is necessary to avoid future refrigerant leakage.

  • @ajmal1856
    @ajmal1856 2 года назад

    sir ac kaam laghbhag kitne time Mai sikha jata hai aur jaise ab sardi hai toh kya yeh kaam sardi Mai bhi rahega jaise hot and cool ac bhi aati hai na aur sikhne par kitne paise milte hai kya yeh kaam 12 ke bara rehta hai plz tell

  • @nasaruddinkazi7506
    @nasaruddinkazi7506 Год назад +1

    अरे भाई उसने विडिओ देखकर 10मिनिटमे सिखने का बोला हैं. ना कि इंस्टॉलेशन करने का टाइम. 👍🏻

  • @nishantkushwaha3356
    @nishantkushwaha3356 Год назад

    Green wire kaam Hota h bha.. Earthing Larne me liye..

  • @rajtera3103
    @rajtera3103 Год назад

    LG ke ac achhe hote hai kya cooling Achhi krte hai and durable hai ya nhi please sir reply me

    • @Tanusuperstar
      @Tanusuperstar  Год назад

      Cooling zyaada nhi hoti hai

    • @rajtera3103
      @rajtera3103 Год назад

      @@Tanusuperstar achha others brand ke comparison LG kam cooling krta hai but Why aise kya kami hai LG air conditioner Me mujhe smjh?nhi aa rha 😐😐🤔🤔🤔

  • @adityavermavlogs4593
    @adityavermavlogs4593 2 года назад

    Osm bahi

  • @HVACTechnician-rp3kh
    @HVACTechnician-rp3kh 6 месяцев назад

    Split AC measurements Video banao Bhai measurements sikhna hai

  • @RashidAnsari-mb8hg
    @RashidAnsari-mb8hg Год назад

    Ser aapne ek galti kar diya hai aapko tap lone tap lagana chahiye isse gas leak nahi hoti hai

  • @SarathiSarathi-cm3gi
    @SarathiSarathi-cm3gi Год назад

    My ac my all room wow full chilll

  • @VikashKumar-tl8vm
    @VikashKumar-tl8vm Год назад

    Thanks sir

  • @kamalhusainkamalhusain2825
    @kamalhusainkamalhusain2825 Год назад

    Very good

  • @sushilkori89
    @sushilkori89 Год назад

    Super 👍👍👍👍👍👍

  • @Vijay-nx7ww
    @Vijay-nx7ww Год назад

    Brother why have not done vaccum indoor pipe before letting gas? It's wrong.

  • @Urbanboi2600
    @Urbanboi2600 7 месяцев назад

    Our technician Didn't vacuum my ac direct on ke diya Pr shi chl rha h any problem??

  • @jamit684
    @jamit684 Год назад

    I purchased a new llyod inverter ac the outdoor unit stop for few minutes after working then starts agains (Is it normal)

  • @ashishalok6502
    @ashishalok6502 5 месяцев назад

    Thnx 😊

  • @tarashrestha9679
    @tarashrestha9679 Год назад

    Good ❤

  • @bishalsingh3914
    @bishalsingh3914 Год назад

    Bhai ek ac suggest Karo 1.5 ton ka

  • @gurname7509
    @gurname7509 Год назад

    Nyc bro

  • @targetdefencebyajayarmy6245
    @targetdefencebyajayarmy6245 2 года назад

    Gus kholne ke baad bhi aap likej check kar lijiy bhaiya ❤️

  • @shamsadkhan8902
    @shamsadkhan8902 Год назад +2

    Bro aap teplon tape use nhi kiye

  • @ameenhashmi2451
    @ameenhashmi2451 Год назад

    Bhai tum video kiske liye bnaye ho ac technician kr liye ya fir aam janta ke liye agar ac technician ke liye bnaye ho to sab chiz ka name le kar btao

  • @turismoknowledgewithrealey2648
    @turismoknowledgewithrealey2648 Год назад +2

    Lol core cutting tool k jagah breker se square hole kiya isme unessesary big hole hota h leakege hone k sambhavna hoti h barsat ka pani papdi nikal jati h wall k

  • @AnkitAnkitkumar-ho5oi
    @AnkitAnkitkumar-ho5oi 2 года назад

    Thanks 🙏💕🙏💕🙏💕🙏💕🙏💕 bhai

  • @RowdyAbhay
    @RowdyAbhay Год назад +3

    Bhai vacuum to Kiya hi nahin aur walls mein teflon tape nahi lagaya 😂 . Kay ac fitting Karega tu 😂😂

  • @parvezqureshi7331
    @parvezqureshi7331 Год назад

    Bhai 10 min ni tu 2 hrs le lekin instalation proper kar left me hole karne me kya problem tha barish ka paani seedha pipe se room ke ander jayega

  • @Afjal05-q6z
    @Afjal05-q6z Год назад +3

    Brother Split Type Air Condition Not Good installing

  • @NGKARAN-f
    @NGKARAN-f 5 месяцев назад

    Bhai tane direct connection kya h h jo.last h mai indor ka worring ka connection rehta h wo kaha pr kya h

  • @muthuselvan6479
    @muthuselvan6479 2 года назад

    Earth is very important

  • @sohailsaifi8075
    @sohailsaifi8075 Год назад +2

    Bhai underground piping bhi hogi tb bhi 10 mnt m fitting na hove

  • @islamactech
    @islamactech Год назад

    Good job ❄️

  • @rishi____1909
    @rishi____1909 5 месяцев назад

    bhai installation pipe already rehta hai na box me

  • @MDRIJWAN703
    @MDRIJWAN703 7 месяцев назад

    Pipe nhi tube bolo dost, mistakes no 2, gas open kr ke uske bad volume open krna chahiye.

  • @viveksingh4572
    @viveksingh4572 2 года назад +11

    Does plug top and drain pipe come free of cost while installation or we have to pay extra?

    • @tarunpal6573
      @tarunpal6573 2 года назад +2

      60 rs pet foot

    • @Sigma.com07
      @Sigma.com07 2 года назад

      @@tarunpal6573 90 rupay mitter

    • @sushantgupta9336
      @sushantgupta9336 2 года назад +2

      Drain pipe comes free along with this Indoor unit. 10 feet copper wire both ( think 10 feet & Thick 10 feet) also comes free of cost with remote, all screws

    • @rafirefrigeration4189
      @rafirefrigeration4189 Год назад +1

      3pin top
      Drain extra xtra charge

  • @fluffybunny510
    @fluffybunny510 Год назад +1

    Kripiya aysa mistrio ko nah bulay, serf company ke service person ko bulai, chahe 200 300 jayda lage

  • @akashdeep4190
    @akashdeep4190 2 года назад +2

    Hi brother good installation but aapane vacuum to Kiya hi nahin

    • @sohailkotwal3042
      @sohailkotwal3042 Год назад

      New machin ko vacum karna zaruri nh h falash karke bhi ho jaynga

  • @dheerajgrover8847
    @dheerajgrover8847 Год назад

    Bhai vaccum krna jaruri h kya

  • @guridhami4600
    @guridhami4600 2 года назад

    22 sahab jo Lg ka Ac ka moschir taype ati oo app kuu nee coper pipe la lagata

  • @Faiztourvlogs
    @Faiztourvlogs 2 года назад

    Lege rho kamyami milegi

  • @আমরাগ্রামেরছেলে-র৭ব

    dear sir aapane Jo yah video upload kiya bahut badhiya hai lekin iska install Karne Ka Tarika pura galat Pahli Baat inhone AC ka jo pipe hai vah back Tu back Kar Diya Yahan per back Tu back karne ka koi jarurat Nahin Hai aur yah inverter machine hai LG ka yah unhone Bina vacuum kiye gas Chhod Diye ya thoda gas Panch bhi kar dete Tu Bhi chalta दो-तीन Sal chalne ka bad machine Mein gas to Phool rahega lekin cooling ka problem aaega

    • @Tanusuperstar
      @Tanusuperstar  2 года назад

      Sahi kha sir aapne ye problem 3 mahine me hi hogyi muje

  • @Lazyaktarshorts
    @Lazyaktarshorts Год назад

    Good workings

  • @wahidali3871
    @wahidali3871 Год назад

    Nice dusra video laiye

  • @brarsaab007
    @brarsaab007 2 года назад

    Good job Bhai vacuum nahi karte new ac ko, aur bhai mare indoor ka wire nahi nikla, jo ac fiting karne aya tha ussne 30 futt wire magvai ussi wire main se outdoor main se indoor unit ko main supply chala di kahi wo wire sath tho nahi lai gaya, maine dakin 1ton 5 star inverter split ac 2022 series ka kal he intonation karwaya hai aur flipkart se by kiya hai, please reply fast qyokay wire indoor ki agar sath atti hai tho main tactician se lai luga please reply fast 🙏

    • @Tanusuperstar
      @Tanusuperstar  2 года назад

      Bhai new ac me vaccum krne ki zarurat nhi hoti. Wire ki bat kre to har company ka alag system hota hai koi sath me deta hai koi nhi deta

    • @brarsaab007
      @brarsaab007 2 года назад

      @@Tanusuperstar jo Daikin k tancion ae the unke pass ek motor thi usse outdoor main laga dia kuch time 2,3 minutes lagaker motoe chala di fhir uttar kar pipe concision kia ?

    • @faishalansari9779
      @faishalansari9779 2 года назад +1

      Daikin me men conection outdoor se ata h. isiliye daikin wale men wair nhi dete h sb wo alg se lagta h

  • @AsifKhan-bw2yk
    @AsifKhan-bw2yk 2 года назад +1

    Kya bhai sahab aap 10 minute ac fit ker sakte ho 10 minute main toh dril holl nahi kar sakte ho

  • @khansahab7917
    @khansahab7917 Год назад

    Or inweter ac instoletion kar rahe ho to Bina vacuum kiye hi gass chod sakte kya mera bhai 2 se 3 digri ka fark aata na meri jaan

  • @Punpreet
    @Punpreet 2 года назад +1

    Most important vecum

  • @saurabhvajpayee4732
    @saurabhvajpayee4732 2 года назад

    Sir ye jo outdoor hai ager usme barish ka pani gire ga to ye kharab nahi ho jaye ga?

  • @ahteshamparvez4939
    @ahteshamparvez4939 2 года назад +1

    Bhai Mere Ek Baat Btao Tum Aapko Ac Ke Bare Me Sab Samjhta Hai Kya Mota Pipe Patla Pipe Bhai Mere Ye Technician Ki Language Nahi Hai Mere Bhai Aur Pipe Ko Aisa Nahi Bole 1/4 Ka Pipe And 1/2 Ka Pipe Bolte Hai Aur 50 Pressures Aapne Chod Diye Ho To 10/15 Mint Rakhna Padhta Hai Lekage Ke Liye Check Kerne Tak Lekage Milega Mere Bhai

  • @Friendscoolingsystemjasola
    @Friendscoolingsystemjasola 2 года назад

    Bhai sb kuch thikh tha pr Do glti bhaut bdi ki h jisse lg raha h aap ek dukaan wale h jisne instolletion ki h na ki DSC wale LG ke ok

  • @manojkumarrajput5220
    @manojkumarrajput5220 8 месяцев назад

    Sar green taar ka koi kaam nahi hai Bina kisi kaam k he ye taar kampni deti hai kya

  • @Kharaybhau111
    @Kharaybhau111 Год назад +1

    LG ka AC department mai hi sambhal ta hu..... video dekh ke maja aaya😅

    • @rajtera3103
      @rajtera3103 Год назад

      Sir kuch log keh rhe hai ki LG ke ac cooling kam krte hai kya yeh baat sach hai aap toh department smbaalte ho aapko pta hoga iss baare me

    • @rajtera3103
      @rajtera3103 Год назад

      LG ke Ac lene chahiye ya nhi mujhe LG bahut achha lgta hai but logo ki baate sun kr dar lgta hai lene me cooling achhi nhi hui toh kya?kroonga

    • @Kharaybhau111
      @Kharaybhau111 Год назад

      Dekho aisa hai ki apni company hi sbko achhi lagti hai......pr mai ye kahena chahunga LG se bhi achhi cooling wali company hai market me.....

    • @Kharaybhau111
      @Kharaybhau111 Год назад

      Go for other company.....👍🙏

    • @rajtera3103
      @rajtera3103 Год назад

      @@Kharaybhau111 other company bahut hai best,ho woh btao

  • @prabhatyadavofficial8606
    @prabhatyadavofficial8606 2 года назад +1

    Sir taflon tef bhi laga Dena chahiye tha

  • @ItachiUchiha-fy9vq
    @ItachiUchiha-fy9vq Год назад

    Kitna karch aya installation me

  • @nishantkushwaha3356
    @nishantkushwaha3356 Год назад

    Bhai ye mota pipe.. Patla pipe kya Hota h... Sahi se bolo.. Bade size ka pipe suction line hoti h.. Chote size ki pipe. Discrharg line hoti h..