Daylighting in LBTools: Annual Daylighting Recipe

Поделиться
HTML-код
  • Опубликовано: 19 сен 2024

Комментарии • 5

  • @josefpodmolik511
    @josefpodmolik511 Год назад

    For the Spatial Daylight Autonomy (SDA), you mentioned that it is How much space gets at least 300 lux for at least 50 % of the year. I believe it should be for at least 50 % of occupied hours (those that are defined in the schedule you used).

  • @nan_nan_qwp
    @nan_nan_qwp 3 месяца назад

    I tried to make the depth of the wall by extruding the window. But the direction is different. What should I do when I want the direction to be all in or out?

  • @francescoemanuelecontaldo659
    @francescoemanuelecontaldo659 2 года назад

    Thanks a lot for sharing this. It is really clear and straitforward and the audio i sperfect.
    I am figuring out how to use, if possible, this tool to coomplish LEED credit for daylighting.
    In this regard I would like to ask your support, in order to simulate daylighting I have to:
    1. calculation grids should be no more than 2 feet (600 millimeters), how this translate to grid units?
    2. check when ASE1000,250 is greater than 10% for occupied space, what is ASE1000,250, how can I calculate that and draw a map identifying spaces where it is grater thatn 10%?
    3. for exemplary poiint Each regularly occupied space achieves sDA300/50% value of at least 55%, do you know what that means and how to calculate it?
    Thanks a lot

  • @marcinbrzezicki1860
    @marcinbrzezicki1860 2 года назад

    I would like to thank you for the presentation. I am experiencing a problem with _thresholds, when I do change the values in the way that is shown in the video the calculation crashes showing "* 1 failed: - 1 _Main_4fe81c3cOrchestrator(…)" Can you help with this? I am using Ladybug 1.3.0

    • @MostaphaSadeghipour
      @MostaphaSadeghipour 2 года назад

      Hi Marcin! You should post your questions to the Ladybug Tools forum: discourse.ladybug.tools