Размер видео: 1280 X 720853 X 480640 X 360
Показать панель управления
Автовоспроизведение
Автоповтор
Thank you so much sir
Nice
Thanu so much Guru
Thanks bro
sir plot room problem kocham upload cheyara please sir
We will try
Sir 2room building having front veranda video upload kareyee
Earthwork in foundation will be .30+.20+.20+.20+.10= 1.00m not 0.90mThat's a error in the book.
OkI check now
yess
can you tell which book u refer for this? from where did you take this question?
Prof. B.N.Dutta Book name- Estimating and costing in civil engineering.27th revised edition
Aap kaha se sir g
Lintel ma 1.20+0.15+0.15
Window & gate ke upper part pr load transfer krne ke liye use krte h And value both side 0.12-0.15 tk Kuch bhi le skte h
Can you tell in english sir
Thank you so much sir
Nice
Thanu so much Guru
Thanks bro
sir plot room problem kocham upload cheyara please sir
We will try
Sir 2room building having front veranda video upload kareyee
Earthwork in foundation will be
.30+.20+.20+.20+.10= 1.00m not 0.90m
That's a error in the book.
Ok
I check now
yess
can you tell which book u refer for this? from where did you take this question?
Prof. B.N.Dutta
Book name- Estimating and costing in civil engineering.
27th revised edition
Aap kaha se sir g
Lintel ma 1.20+0.15+0.15
Window & gate ke upper part pr load transfer krne ke liye use krte h
And value both side
0.12-0.15 tk Kuch bhi le skte h
Can you tell in english sir