Roof Slab Level Concealed Beam

Поделиться
HTML-код
  • Опубликовано: 28 авг 2024
  • Roof Slab Level Concealed Beam

Комментарии • 40

  • @jothimuruganc2727
    @jothimuruganc2727 4 года назад +3

    Great sir explain very yousful

  • @jayagandhi6275
    @jayagandhi6275 4 года назад +1

    Points of speaking very very use full super sir

  • @Er.G.B.VIMALRAJ
    @Er.G.B.VIMALRAJ 5 лет назад +2

    Arumayana thagaval.... but na niraya buildingla paathuruken sir enga v2 pakkathula kuda apdi oru building pannirukanga only earth beam 1feet beam 5nos 12mm mattum pottutu mela mela athavathu G+2 Athukkumela oru head room or water tank vachi pannirukanga antha building construct panni 12years mela irukkum ithu varaikkum oru problem varala sir nenga sollurathum ennaku puriuthu but na ennakekurena ithaum meeri epdi antha building gambirama nikkithu sir plzz sollunga sir

  • @sjayamurugan9255
    @sjayamurugan9255 Год назад

    Sir grond floor la blinth beam 1.4 inch hight depth 9 inch pottu irukom 4 rod than use pani irukom. First floor and second floor roof level beam potta load edukuma blinth beam... Sollunga...?

  • @chinnappanmurthy8201
    @chinnappanmurthy8201 2 года назад

    Ground floor is in load bearing structure and for first floor we are making extension in framed type. For partition can we use concealed beam??? First floor will be seated on new pillars???, Can we use vermiculite for 1 &1/2 ft beam for supporting the main walls??

  • @ranjithappu283
    @ranjithappu283 4 года назад

    Good Engineering Explanation sir

  • @sudhakarvenkatapathy2066
    @sudhakarvenkatapathy2066 4 года назад +1

    He /his contractor done this wrong procedure
    Can we fix problem like this
    He shd construct d slab as it is and before casting d dummy columns upto parapet he should construct beams 6/10 inches on above roof My view

  • @senthilkumar-xz4uk
    @senthilkumar-xz4uk 3 года назад +1

    Sir Ground floor framed structure ல இருக்கிறது 1st floor load bearing ல கட்டலாமா please explain. Thank you..

  • @selvarajm9832
    @selvarajm9832 3 года назад

    Good explain sir

  • @pokkiritamil007
    @pokkiritamil007 4 года назад +2

    Sir same mistake done in my house Ground floor la concealed beam pottu irrukang , but G+1 dhan construct panni irrukom , first floor la mattum roof level la beam pottu irrukang like framed structure. Is it safe

  • @janavery4634
    @janavery4634 2 года назад

    So this engr. Also confusion till confusion not yet finish

  • @nasracollection7
    @nasracollection7 5 лет назад +1

    How much solutions available....what is solutions for building ???

  • @grajavel03
    @grajavel03 3 года назад +1

    Sir oru doubt, lintel level la beam potutomla athu load da carry pannatha.? Athum nama column kooda thane connect pani irukom
    Please clarify my doubt

    • @KumarSEngineering
      @KumarSEngineering  3 года назад +1

      ruclips.net/video/s-U6kPjusZQ/видео.html பார்க்கவும்

    • @Dineshkumar-cy5hs
      @Dineshkumar-cy5hs 3 года назад

      Sila contractors... Neenga Mela roof la sonna regular beam ah..lintel leveleye pondranga (like 1ft beam) .. and then roof level ah either concealed beam or no beam nu poranga.. is it okay? Pls reply sir.. intha video va avanga Kita kaatuna intha explanation kudukuranga ..

    • @KumarSEngineering
      @KumarSEngineering  3 года назад

      I cont reply to this mastery

  • @swaminathank6161
    @swaminathank6161 3 года назад

    Below this u have inserted rintel beam a sir ..

  • @gopinath8994
    @gopinath8994 3 года назад

    Gud explain

  • @jaffershareef1429
    @jaffershareef1429 4 года назад

    அண்ணா g floor g1 floor பில்டிங் கருங்கள் போட்டு கட்டுவது நல்லதா இல்லை பீம் போட்டு கட்டுவது நல்லதா?

  • @manimaran.muthumari7085
    @manimaran.muthumari7085 4 года назад +1

    Sir in cantilever why we are providing main rod at top sir

  • @raviv8678
    @raviv8678 4 года назад

    Super brother

  • @irusanirusan6313
    @irusanirusan6313 4 года назад

    Super sir .....

  • @jadesamy3220
    @jadesamy3220 4 года назад

    Super

  • @TechTalk555
    @TechTalk555 Год назад

    Contactor work theriyathavan pola

  • @ashishshegokar542
    @ashishshegokar542 4 года назад

    Epudi erikiringa

  • @sathishs7490
    @sathishs7490 4 года назад

    Difference between column & pillar, reply sir

  • @muruganmuthusamy9976
    @muruganmuthusamy9976 3 года назад

    Fine

  • @gokulstram125
    @gokulstram125 5 лет назад

    sir ethathu job vacancy erukungalanga sir ,i am B.E civil

  • @ashishshegokar542
    @ashishshegokar542 4 года назад

    Sir I m from Maharashtra. Please make this video in translation of Hindi.

  • @ashishshegokar542
    @ashishshegokar542 4 года назад

    Sir please make it in hindI.

  • @gnanaprakash7013
    @gnanaprakash7013 3 года назад

    U r number kuduga