on grid solar power system | How to install solar power system for home | solar system
HTML-код
- Опубликовано: 15 сен 2024
- Hello Friends today I have put video about on grid solar power plant system wiring diagram
In this video I don't use battery and use bidirectional energy meter
so that you have save your money and also maintenance of power plant is down
there is much better plant against off grid power plant because of battery replacement cost is very high so I will refer you on grid power plant.
solar energy is simply the light and heat that come from the sun people can harness the sun energy in a few different ways photovoltaic cells which convert sunlight into electricity. passive solar heating which can be as simple as letting the sun shine through windows to heat the inside of a building.
How is solar panel work?
simply put a solar panel works by allowing photons or particles of light to knock electrons free from atoms generating a flow of electricity. solar panels actually comprise many smaller units called photovoltaic cells. this all adds up to an electric field at the junction between the silicon layers.
What is an inverter used for?
An inverter converts the DC electricity from sources such as
batteries or fuel cells to AC electricity. The electricity can
be at any required voltage; in particular it can operate AC
equipment designed for mains operation, or rectified to produce
DC at any desired voltage.
also friends I have put much more video about house wiring related video
so please visit my channel once and if you like my channel than please subscribe my channel and share my video with your friends
Also give me your suggestions in comments box so that i will make much more effective video.
Thank you...🙏🙏🙏
Your video is very good people can understand easily thank u for make this type of videos👌😊
Thank you for your feedback
A very straightforward explanation.Thanks
Thank you so much
So good video presentation, thank you for sharing!
Thank you so much
Excellent concept diagram no one share like this way.
Thank you so much brother.
Understanding simply with this great animated video. Thanks
Great video, this was a detailed breakdown of the components I was looking for.
Thank you
Same diagram uses electrical power to solar grid power meet time short sarcute yes or no
It's amazing video for real work execution really nice job !!!
Thank you........
Wow
This is so well explained.
Really good job.
Best
Thank you so much
Your video best training in field of study by Green Power Enterprises
Thank you so much......
Very well demonstrated without saying a word. Or showing your dog or house or daughter.
And yes anyone who cannot understand this, perhaps lack the basic knowledge of domestic electrical setup and so should get into this at all.
Do you have a similar demonstration for a grid tied system with battery - both as first installation and as an add on? That will be very helpful.
Thank you
I have aldo one video on hybrid solar system in that system i have use battery Inverter and grid power supply also
ruclips.net/video/HOgpuZK7UCo/видео.html
Very well Explained through line diagram
Thank you so much
Cool
Thank you.....
Aap bahot achhe video banate ho
Thank you........
Kya bat he bhai apart video 1 no....
thank you......
Of grid solar panels ke liye bhi video banaye
Good explanation
Thank you......
I will make next video on that topic
Its really cool nice video
Thank you
Aap Ka video hame Bahut badhay lagta he..
Thank you......
Kay Khub video banaya he sir.....
Thank you......
Very good video. Thanks!
Thank you.......so much..........
Superb explanation... very helpful for learning... please upload daily 1 video brother ... keep it up.
Thank you......
VERY GOOD . THAT DOUBLE POLE BREAKER UNIT IS ORDINARY BRAKER OR ELCB . ?
Super excited bhau
Thank you 💟💟😊
Apka video achcha hota he
Thank you.......
thanks for teach us... i love u
Welcome 👍🏻👍🏻
Very nice idea
Thank you.....
VERY nice explained VIDEO sar🙏🙏🙏
Thank you so much
Please subscribe my channel ☺️🙂
@@MrEngineerss subscribe kar Liya hai 🙏🙏
Thank you ...
Excellent. Well done!
Thank you......
Tnx
Welcome
Good job
Thank you.....
Good video sir..
Thank you.....
Nice video
Thank you.....
Useful information
Thank you........
Great 👍
Thank you.........
Please could you explain further on how the output from the inverter and the output from the utility meter is connected to the breaker switch
I Think the disconnect and the mcb is used as the breaker is in series with the energy bidirectional energy meter,
And the solar inverter is parallel to the utility source
One Of The Best and Excellent Explanation I have ever Come across .Many Thanks !! & Best Wishes !!.Can you Please try to Clarify What is the difference between Sizing for On Grid System and Sizing for Off Grid System & What are the protection trips On Grid System .( The Off Grid System requires full plus spare sizing of KVA/KW Rating then how does the On Grid System Cater the Full load does it need to be Sized for Full load plus Spare ? Can you please try to clarify ?
Thank you so much ❣️❣️
I want to get a perfect calculation as. Actual domestic solar plant such like 5kw and i will make video on that data
But it takes some time.
Excellent work
Thank you.....
Thanks brother❤❤❤❤❤
Welcome
Nice video 👍
Thank you 😊
Very nicely explained. I guess the wiring is coming from netmeter to isolator but it looks more like an RCCB!
Thank you.....
here we connect at meter side form solar output because for house supply come from RCCB so all appliances run safely
Weldon Mr
Thank you so much ❣️
Good
Thank you......sir
EXCELLENT
Thank you so much
Thank you so much
Nice
Thank you........
Nice 👍
Thank you
From output of inverter can i connect directly to the output of bidirectional meter instead of RCCB
Yes you can connected
But for protection purpose rccb is must
Super sir
Thank you so much
👌👌👌 Good
Thank you......
good sor
Thank you.,..
good
Thank you so much
Good video. Why do you two circuit breaker attached to each other after the inverter? Why are both of them of a different types? Why are 3 positive wires (RED) coming out and only sticking in the air (or where should they stick)? Please confirm asap as I am working on a project. Thanks!
There is one mcb and 2nd is elcb that's protect us from human short circuit so both are required
Dear brother,
Does this ongrid solar system work in daytime when grid power fail for sometime.??
There is no any battery back so whenever grid supply is fail at that time not working
But if you use hybrid solar system inverter use in your setup than its work
Hi for total 3 phase how many cable should come from pillar 3 + 1 or 4 +1
Superb
Thank you....
How you connect 2 different phase before circuit breaker?
Very nice explainand
Thank you so much
Bhai aek video off grid solar power system par bhi banaye .....
Thank you.......
Something looks off at the main circuit breaker. You do not have a way of disconnecting the inverter from the grid. You have 2 circuit breakers connected in line?? Why??
Aap aek video off grid solar system ke uper bhi banaae bhai
Ok i will make it very soon
Where is the change over switch for grid and inverter output interconnection?
Grid tie systems automatically manage energy flow eliminating the need for change over switches. Any energy above the required load is fed to the grid, that's where the bidirectional energy meter comes to use.
Thanks
Welcome
How to connect off grid solar system and grid system in on the existing panel
In this channel there are 2 more video available for solar panel please see that video your questions solve definitely
ভাই আমার একটি প্রশ্ন আছে।আপনি ইনভাটার থেকে ব্রেকারে সংযোগ দিলেন,এখানে মিটার পরিবতন করতে গেলে ব্রৈকার থেকে লাইন মিটারে চলে যাবে তো
Music is distracting. Better to have someone talking and explaining things.
Thanks for your advice i will make changes in next video
Super
Thank you 😊
sir can this work well?
power goes into the inverter then pull the power cable into the mcb on the far right then into the main source a
Lvd goes to the 48v relay to trigger the relay
Then the AC inverter goes to the relay via hole no
Pull the cable from the MCB AC inverter output to the contractor so that the load doesn't pass through the relay then enters it into the ATS source B
👍👍
Something is missing here , how exactly the system ( devices ) will "chose" from where the electricity will come ? As both sources are connected on same string ( based on this diagram ) ? I assume that from utility pole need to go 1st to Solar inverter and then to the appliance inside home and then when you don't have enough power from the PV it will be "added" from the grid. Correct me if i'm wrong.
This is old model diagram in new model there is 2 meter are use so nothing is problem.
Your point is also right which electricity is used solar or utility pole
But in this system there is depend on load is load is very hight at that time utility pole use and load is low at that time solar energy is go back to meter reading
@@MrEngineerss.will you please upload new model diagram. Whats is the different between boath diagram.
I have already uploaded new one diagram for hybrid solar system
ruclips.net/video/HOgpuZK7UCo/видео.html
Yes in order to combine the power grid with inverter output you will need an Automatic Transfer Switch, not only to determine which type of power to choose, but the grid and the inverter have different sine wave fases, the ATS need to synchronize the fases and then make the switch
How to stop normal power ac solar power uses caluclation continue connect both eqval energy so how reduce electricity bill
If the grid goes down will this system stay up? (As long as the system is already running...)
No isolation between inverter and grid. Acdb to be fixed in between inverter and energy meter.
If you are running without battery, can you parallel pv input and grid? I mean both grid and solar are feeding the same load...the grid compensates if solar is running low...is it possible?
Yes this is possible and we can also use 2 electric meter
1 is for solar and 2nd is for load come into house
great video.
the grid power wouln't damage the ac inverter? that's lot of power
Thank you......
Grid power can't damage due to double power safety features
@@MrEngineerss I am facing the AC inverter damage issue due to high grid power so what are those double protection that you are talking about? What are those devices after bidirectional energy meter? RLCB and SPD? And next MCB for individual circuits?
For High and low voltage you have to use voltage monitoring rely in circuit all problems will be solved
Sir, may question po ako..
Familiar po kayo sa power conditioner? Eto po ginagamit sa Japan.. since japan po, ang output voltage po ay 100v, hanggang 202v
Ang tanong ko po ay pwede po kaya ito magamit sa pilipinas.?
I can't understand what you want to say
Inverter vala solar system ka video bhi banana bhai
Okok bhai next video banauga uspe bhi
My second question.. I see tht there. Is a bidirection meter installed. If I have a free energy from the solar which go in together with the power from the pole...will the bidirectional meter read all the power supply as additional consumption or what? I am afraid they will charge me additional electricity charges for the solar energy input
That is depend on meter reader person in bidirectional meter both reading take individual such like energy consumption by us and energy production by solar pannel
So that is differ in other options we can put 2 meter individual so that we can also real meter reading
👌👌👌
Thank you......
Also make video for solar pannel with inverter battery
I will make it very soon
do you have simulation of this? it will be very helpful for me.
Sorry i haven't
Solari +_ orumich connect cheyyamo
👌👌
Thank you......
very good video. thank you. can you make us another video for the 2 sting db box the accessories needed and how the connections are made? I want to connect 10 panels in a 24v 12ah series
Yes I will make video on your demand but please give me some time for that video making....
Thank you for your suggestions
many likes from me. if I understood the plan well. in case the load of the house is less than the load produced by the panels. the excess is returned and the meter in case it is proportional returns;
net metering not require 240 v. it does not matter 120 v or 240 v. plus, inventer 240 v is cost more, no benefit. additional tools as AC PV disconnect box as bridge between inventer AC output and home electrical meter , one DC PV system disconnect box.
Bro you can edit this video with any software give me the link of that software I also want to edit it bro.
Means we donot need battery ac output from inverter to breaker direct. Is it correct
Yes you are right ...
I can understand the rest but on the solar system I m totally blur. I see two of the solar array were connected is 3 series top and bottom ..is it 3 series 2 parrellel... And the wire connected to the DB.. both +- combined to each of the input solar DB respectively on each holes. How do I know which one is positive and negative? Can u really combine +- line and serve as input on each DB INPUT?
Or is it consisting 4 terminal holes with each + - input...tht would make a sense then...thks
Got it ....after zooming in Ur wire inside the box.
240 vac to neutral. USA 120 vac to neutral. Pretty high volts in your country.
Yes in india use 240 v ac voltage to neutral
WHY YOU DIRECT THE LIVE WIRE OR GRID POWER LINE INTO THE INVERTER ISNT THAT DANGEROUS WITHOUT BREAKER.
THERE ARE CIRCUIT BRAKER IN 2 STING BOX IN THE FORM OF A FUSE
Yes u r. right need 1 contactor between them
,👍👍
Thank you.......
Kindly share video hybrid ongrid system diagram thx.
I have already make on that topic 🙂🙂
ruclips.net/video/HOgpuZK7UCo/видео.html
bro which software you use for making this circuit diagram
Doodly app i have use for pc
Inviter Grid input missing....
why u take common earthing in ac or dc side ????
Therr is no difference in ac earthing amd dc earthing.
Earthing is earthing
ভাই আপনি এরকম এর ভিডিও কোন সফটওয়্যার এর মাধ্যমে এডিট করে বানান সেই সফটওয়্যার এর লিংকটি দিবেন আমিও এডিট করে বানাতে চাই
Ok air plz 20 panal hi to kya karna hi
Send 3phase sollar systems.
Where is the protection circuit for line workers when the utility power is out and you are not shoving AC from the solar into the lines that are supposed to NOT have power? If none, then you stand a good chance to electrocute utility workers.
If Power Out, Inverter Not work..
dont you need solar meter ?
Here i use bidirectional meter so both reading are there inward and outward
Also we can use 2 meter in same situation
hello what is the device after the meter with double and single switch called ?
Main switch called 25 amps with safety auto shut down when electric shock on off
Collection wrong output and input to direct connection join
Please tell me specific so that i will make change 👍🏻👍🏻
The connection not correct. Dc earthing and AC Earthing should be different line
Not same but that is only body earthing