0040 - Elenco AM/FM-108CK Kit Build: Part 3

Поделиться
HTML-код
  • Опубликовано: 12 сен 2024

Комментарии • 8

  • @stargazer30721
    @stargazer30721 Год назад +1

    Good idea for the blocking cap!!! I ordered a test clip to build the same thing for future testing.

  • @spiritofseventysix1155
    @spiritofseventysix1155 Год назад +1

    Marvelous, wish I found you sooner for my kids to see you at this putting together a radio kit... great share here.
    💪Yes We Can!
    Shabbat Shalom
    Ci vediamo
    (Until) we meet again, see you, soon!)
    Best -
    Mordechai
    🇮🇲Threelegsoman⚾️

  • @stargazer30721
    @stargazer30721 Год назад +1

    oh and BTW - another excellent video!

  • @stargazer30721
    @stargazer30721 Год назад +1

    On page 30 under AGC action, I measured 0.88v, BUT Vb in the AC Gain section was measured at 82mVpp. That math made AC Gain equal to way less than 100. Can I redo this measurement even though the remainder of the AM section is complete? I feel confident my oscope setup was incorrect. I can't tell from your scope inset video what your settings are (my bad eyes on a laptop). Should I be reading amplitude or RMS from my measurement window?
    Back to AGC action - I read elsewhere to read a different value from the scope - can't find my source. Amplitude vs. RMS?? What I read may have caused me to pick up the wrong value for Vb.

    • @uni-byte
      @uni-byte  Год назад +1

      There should be no problem going back and doing it again.
      Stick to Vpp, both for input and for measurement on the scope. Theoretically it should not matter (RNS vs Vpp) as long as you are consistent and use the same measurement for both input and output. However, they are asking for Vpp so it would be best to use that so you have a better chance of yor reading matching theirs.
      My scope was set to AC and 1V/div. The scope probe was set to 10X. Be sure to let the scope know your probe is set to 10X. What model scope do you have?

    • @stargazer30721
      @stargazer30721 Год назад +1

      @@uni-byte Siglent SDS2202X-E and a Tektronix TDS 340

    • @uni-byte
      @uni-byte  Год назад +1

      @@stargazer30721 Okay, on the Siglent, make sure the input is set to Hi-Z too. I have no experience with the Tek.