How much to set the Overload Relay range || overload relay setting and calculation - Electrical Dost
HTML-код
- Опубликовано: 14 окт 2024
- How to know if you set the correct current on a motor thermal overload relay - How to Calculate Motor Overload - electrical dost
I am Aayush Sharma Welcome to Our RUclips channel Electrical Dost.
About this video-
Dosto Aaj Ki Is Video me maine overload relay ki ampere range ko kitne par set karna hai yeh btane Ki Kosish Ki Hai Or Kuch electrical tips jaise what is Rated current of motor, what is overload relay, Full load current meaning, overload relay which protection give us, Electrical motor work and Electrician interview questions answers share kiya hai. Ummed hai aapko yeh video bahut pasnd aayegi (hindi,urdu)
Thank you so much..........
......................................................
इलेक्ट्रिकल से जुडी पोस्ट हिन्दी मे पढ़ने के लिए हमारी वेबसाइट इंजीनियरिंग दोस्त (Engineering Dost) को गूगल पर सर्च करे।
......................................................
Our some other videos -
mcb and mccb difference
• mcb and mccb differenc...
..
..
mcb vs rccb difference
• mcb vs rccb difference...
..
..
Dol starter power and control.
• Dol starter in hindi d...
..
..
how to read motor nameplate.
• motor nameplate in hin...
..
..
cable size calculation
• Cable size calculation...
..................................................................................................................
Queries Solved:
1) How to put the settings of thermal overload relay?
2) Basics Of Selecting Overload Relays
3) basic electrical interview tips
4) how to set the correct current on a motor thermal overload relay
5) Overload relay setting and calculation in hindi
8) OLR selection tips
9) Basic electrical knowledge
10) electrical video in hindi
Email - Aayushsharma0713@gmail.com
#motor #overloadrelay #OLR #circuit breaker #setting #load #Electrician #Question #Electrical
#electricalhindi
Don't forget to SUBSCRIBE electrical dost for more Trusted electrical videos.
very nice explain easy to understanding
Good sir helpfull video
Good knowledge bro
Bahut achi relay ki setting karana bataya thank u sir
Bahut achha sir nice video
Super video sir ji
Best knowledge sir☺️☺️☺️
Keep continue it
I am your fan thanks
useful electrical knowledge👍
Thank you so much sir
Good knowledge sir
Very nice information sir God bless you..
Nice
Sir
Super sir
Respected sir ji
Thanks you sir.
Nice current information
सर नमस्ते आपकी जाकारी बहुत ही उपयोगी है मै किसान हु और मेरे यहाँ ट्यूबवेल के सबमर्सिबल पम्प है जिन्हें हम hp रेट से जानते है मेरे पास 5 hp के पंप है में इनके स्टार्टर की रिले कैसे सेट करूँ मेरे पास तो क्लेम्प मीटर नही है और मेरे गांव के मोटर vaindr को भी ये जानकारी नही है वेसे मेने मेडिकल इलेक्ट्रॉनिक का डिप्लोमा किया हुआ है
👌👌👌
Good information thanks
Excellent
Thanks sir
Badiya bhai
Very helpful video sir
Tnx boos
Circuit breaker really se pehle lagana hai ya baad me
Nice
Agar hum running current me set karenge to Jab ye full load me chalegi tab to ye hamesha trip karegi, to mujhe lagta h FLC pe hi set karna padega
Guru ji ek busbar k upar video jrur bnaye uske system k bare me
Nice video
Very nice sir
sir rated current aur running current me kitna difference hona chaiye??for e.g if motor namplate current is 10A then how much current is normal during running??
Good explain
nice video thank you
Sir but motor to starting me 4 to 5 times current jada leta hai to uss samay ye relay trip karega kya?
Kabhi mpr d2 ka full ditel video to banao
Make a detailed video about Transformer Vector Group & Details of Insulation class
Sir electrical drives (vfd) ke baare me video banaye... Kyoki aaj ke time me har industrys mai hame drives hi jyaada dekh ne ko milti hai.. break down me kabhi dikkat hoti hai..my request sir 🙏🙏🙏🙏🙏
Phase current ka ya line current ka 1.15 se guna karna hai.
Sir I'm so confused.....sir aple relay ke setting se related aur ek vedio bnaya he.....bt us vedio me aapne kaha ki motor ke FLC se 20% kam aur 20% jyda vr setting kre.....aur iss vedio me kaha ki motor ki rating se jyda pr set na krte....sir pls give a reply I'm totally confused aur sir is vedio me 1.74 se multiply krne ke liye kaha tha bt iss vedio me 1.15 multiply krne ke liye kh rhe he??
Motor ka rated current name plate mai dekha kar same set kare overload mai.20% zayda nahi rakhna, voo alag concepta hai.It depends on class of overload real also whether it is class 20, 30 or 10.
No need to set current in overload relay 20% above,its other concept.Check motor name plate and set rated current as per name plate in overload relay.
While selection of overload realy also check class whether it is class 10,20,30
This video about how to set current in OLR but you talking about how to select OLR according to current.
Please make vedio on MOV ( metal-oxdie varistor)
Krishan ji kya aap mujhe MOV ka full form bta skte hai. Mai jrur video banane ki kosis krunga, agar mujhe eska practical knowledge hoga to.
@@electricaldost ok sir , thank you
Agar clamp meter se measure karne se 3 phase mein different current aye to??😢
Lugs ke upar video banvo bhai
Brilliant
VFD control wiring and parameters setting par ek video banaye sir
Nii
Nic
Sir contactor selection per video banaye
Soft starter par ek video banaye sir
Sir I have one question mera panel board me three phase contactor burn horaha tha MCB aur overload relay trip Kyu nahi huwa .....Mene main supply off karke phirse start Kiya toh woh phirse chalne laga....iska Kya problem hosakta hai?????
Sir ji mujhe slip ring indoction motor current nikalneka formula chahiye
सर 1 hp की थ्री फेज 415 वोल्ट मोटर को ओवर लोड रिले में कितने ampere पर सेटिंग करें
Thanku Sir.
Sir motor ka rotation change karne ke Lia phase change kar rhe hai rotation change nhi ho rha hai .kya problem ho Sakta hai
Star delta ke main contractor ke olr kitna pr set hoga
Sir, olr ko bypaas kaise karte hai.
Bhai 1.5 add karna h ya multiple
How to find FLC in mouth calculate .which factor to multiply
t.q bhai
Agar panel me oc (overcurrent) aata hai tho kya karna hai
Running current hamesa constant nahi hota he. Motor kabhi kabhi thoda jyada load leta he to kabhi kabhi kam leta he. Isliye hum running current ko dekhkar setting nahi kar sakte he . Yadi running current ko dekhkara setting kare to baar baar setting change karna padega......
o.l.r. should be set at 90% of full load current of motor . ( Star delta starter concept )
So what is rated current is it running or full load current?
Rated current hm hmari motor ki nameplate ke upar likhi hoti hai usko khete hai.. aap usko Full load current bhi khe skte ho..
@@electricaldost ok sir
Sir meter kaise reset kiya jata is par video banav na
3phase motor ka winding restiance kitana hona chahiye... multimeter ke chek kare to...🤔
Star Delta main OLR ke setting kesy karty hin ??
Sir I have a LT MR G2 STATER 10AM ON LOADING AND VOLATAGE IS 310 I WANT TO SET RELAY RANGE HOW MUCH RANGE IS POSSIBLE FOR THAT
Sir, name plate me P1aur P2 jo kw me hote hai wo kya hai?
Sir Electrical dost ka jo app h wah download karne par prophaeil khul nhi rha h help sir
Sir isse kaise check karte hai ki relay sahi hai ya kharab
Resat vale KO.kese rakhna hota h boss
Sir mera 10 hp motar 640 fit hai to riley kitna rakhe help 🙏
Pral relye ka connection kaise karen
bhai ghar ki laght suvich ban me bhi ban jalu hoti he kya karna
Good night
Kindly make a video on how to make equivalent circuit diagram of any electrical ckt .
Relay ka expiry date Kya Hota Hai
Mera ek question he sir ki hum flc ka 80 percent pe over
Load relay Ko seting kar sakte he kya
Sir what is short circuit in real life...
Low voltage par sattar trapping hota hai uspe bataye kya kare
15hp रीली कितने पर्सेंट करना चाहिए
High Court ke bare mein
Single fuse 3 hp motr ka relay kitana rakhna chahiye
Sir 1.15 kiya hota h bataiye
Sir plc control penal ka video banaye
Saddam ji plc ke upar maine 3 video channel par bana rakhe hai.. aap ak baar channel ki playlist ko visit kijiye..
@@electricaldost ok sir
@@electricaldost आपने कोणसा कोर्स किया हे
@@electricaldost आपने कोणसा कोर्स किया हे
मेरा 10hp 12पंखा का मोटर हैं और 12एम्पियर बता रहा है तो रिले कितने में सैट करे
Sir Cilling fen ki winding dada bareme ek video banaiye na
Winding check ki bol rhe hai aap ya phir winding data ki
Winding data ki sir. stater dekhke Winding dada calculete karna sir..
Sir me aap se kyese contact kar sekta hun...?
Load kaise Kam Kare 10 hp ki motor h jishka load 12.97 aata h
Mpr d2 rellay satti ka
5hp mai kitne ka reley set kre
Contactor stuck hunay k bad OR q trip nhe huti
10 HP मोटर में कितना रिले सेट करु बताइये
10hp motor taking current near about 13 amp
Sir ji maine apka electrical dost app rakha hu lekin mujhe RUclips ka naam batana
7.5 HP, 5.5 kw ke liye kitne mai set kare?
Sir 1.15 hi kyu.. multiply karte he??
Ye 1.15 kya hai sir
Sir 1.15 kisika value.
सरजी 3-Phase, 5 HP की मोटर का रिले कितने पर सेट करे ?
Same problem
how we are taking 1.5
Old moter hai name plate nahi hai
To flc kaise pta karein
Fuse ka selection kaise karte hai
Krishnana ji aapko es topic par video channel par mil jaayega.. Aap ak baar check kijiye.
Agar aapko nhi milta hai too comment kijiyega, Mai aapko link send kar dunga..
Agrar flc na Diya ho to kiya kare
btana yaar kese tik kare
Sir aap sea baat krna h