- Hello everyone,
In this video I will show you how you can make a simple automatic water pump on off controller using a relay & a transistor....
This is very easy circuit & anyone can make this.....
Components list...(affiliate link present beside the components, you can buy the products directly by using the following link)
1. 6v relay....amzn.to/2EihGUp
2. bc 547 transistor....amzn.to/2EXbSNr
3. 100 ohms resistor....amzn.to/2G58HCu
4. 1n 4007 diode....amzn.to/2nSZM0C
5. 5v adapter.....amzn.to/2nPEWiz
Subscribe my channel for more updates......
Motor connection keliye iss video ko dekhiye
ruclips.net/video/No-w1N1eaUk/видео.html
that is amazing.
Other videos shows auto on the pump but this shows auto off of the pump.
thanks for sharing.
इस सर्किट में एक कमी है दोस्त पानी का लेबल थोड़ा सा नीचे होते ही मोटर चलने लगेगा बार बार चलने से मोटर खराब हो सकती है बिजली का बिल भी बहुत आयेगा इस कमी को दूर करो मेरे दोस्त प्रयास बढ़िया हिन्दी भी बढ़िया
अपनी बात दूसरे तक पहुँचा लेते हो well done.
सही बात है,, इस कमी को दूर करने के लिए एक रिले और और एक बेल स्विच और लगानी पड़ेगी इस सर्किट के साथ फिर ये ऑटो ऑफ हो जाएगा और ऑफ हीं रहेगा जब तक हम दोबारा बेल स्विच से ऑन नही करेंगे।
@@vipuldeep4812
Or we can control the coil voltage in DOL starter
Good idea but vai yeise karte time me oh panime vi current hota hai kya? Please bataiye
Very nice project bro...👌👍 And u r spoken hindi also Mashaallah...👌
it is not proper way, continuously on/off will make more current, also not enough 7A relay.
don't try your house pump. float switch with contactor can control low level and high level switching and more safety.
Can we use RO low pressure switch in combination with a 220V 10A relay to switch a 1 HP motor?
Yes correct
Bhai your video is awesome but thoda circuit ka diagram bana dijiye....coz we are beginners
U have to put some delay time when the water level reach the bottom like quater tamk then only the motor should start. Otherwise the motor have no rest. Bro. Consider this.
very nice bhoot aacha ma na aaj banaya aacha sa work kar raha hai thanks
Its very good work.
Hello Akash,
My water tank is about 100 meters high. so the sensor wire need to run arour 100 meters. will this circuit work as the resistance of the wire may interfere with the circuit. please clarify.
Nice, bahi chota sa project hai, 12 vlt ki motor pump chalni hai, realy lagana padhe gya kya? Ja sidah batttrry se kam chale ga?
Very nice bai bohot acha vedio hy lykin rely mery hesab se 12 volt charg se kam kartha hy mobile charg kam kartha hy ke nahy ye patha nahy try karlonga nice video
isiliye to 6v ka relay use kiya hai....taki mobile charger se kam kare.....
Sir,
Watertank me jahan pe marking kiyahoga pani toch hote hai moter off hojayega job pani thodasa pani usmarking neche ayga to moter chalu hojayga par jesa pain use hoga fir moter chalu hojayga yes to moter kharp hojayga . Ur kavi watertank pain khatam nai hoga
Sir AAP ki hindi bahot achhe hai
bro
As I connect the probes in the water tank as lower level and higher level
it means that when a slight change in the water cause the motor to run
so the motor will run continuously if we let to use it
yes....this is best for to turn off the motor when the tank is full.....because sometime we forgot to turn off the motor & a lot of water is wasted...
very good , please share scientific side, how will off the led..
Super super nice 👍
I want to use 12v Dc for that any changes required in resistor resistor please share your experience
bhai ye bus band karane ke liye kam ki hai baki jab pani kam hoga to ek point pe motor continuosly on/off karegi or yise motar jal bhi jayegi to proper solution batao
Water ke badle sanitizer use kiya to koh problem hoga kya.agar khali mujhe 12v ki dc motor on off karni hai
No problem
@@TheBreakoutTraderAKASH ek pdf form me drg bhejta hoon uska circuit banake bhej apna wapp number bhej de mere mail id par
Ok bhai aap bhejo... Try karta hun
@@TheBreakoutTraderAKASH wapp no.bhej mail par luthrarajinder555@gmail.com
Jo wire apne water tank me install kiya tha us wire se shock(current) nahi lagega ?
Nhi 5v power ati he usme bas wo 240 wala wire touch ni kre knhi
bro aapne kha that 12v relay ke liye 12v charger use kro mene kiya and it's work thanks but water container me bhut tezz current maar rha h plzz reply asap kya kru jisse water tank me current na aae
Use a good supply.... I think there is some leakage current flowing through water......so use a good supply or use a 12v battery....it is safe....
+How To Bro sorry but what do you mean by leakage current by the way this channel is osm because we get fast reply for doubt keep it up
that means ac current passes at the output...that's why I suggest you to use 12v battery or use 3 pieces of 4v battery to get 12v ...this is the cheaper way....watch my channel I already made a video on 12v battery....
+How To Bro thanks bro
Nice video but please draw circuit diagram first then explain. Thanks
Use latching relay for time delay until the water hit bottom line. Otherwise the motor on off on off when the water slightly down.
पर सर जो वायर टँकी मे होगा क्या उसको हात लगणेसे करंट लगेगा क्या
Relay can Bere amps of pump?
This system works only when there is continues water supply like submersible pumps and also flout switch has to be installed in water tank
Sir....relay me diode ka use kyo krte....plz explain...
Charger bhi aur main bulb wire bhi board me lagaege
Sir,u use one wire to connect positive to transistor, negative to doide but u don't show the another side of wire connection....then where u use charger.
Pani ka table thoda sa bhi kam hoga to motor on ho jayega.. matlab motor pura di on hi hota rahega..
Battery ki jagah trancformer nhi lga sakte
Very nice
Very Nice bro
Main supply auto on /off system . When water come then motor on . When water gone then motor off. PL advice
Dear me electrical k baray me itna khass jantta. To nhi ho.par ap se phochna chata ho k .ap ne main supply AC de ha or moter mens balab to 12vatt dc ha hamarye pass to AC moter ha .or 2nd bat jab moter chalye gi to panni se crunt to nhi lagye ga plzz fast replay
led bulb ac hai not dc.....because led bulb ke under 230v to 12v or 24v ac to dc circuit laga hua raheta hai.....
Sir are you south indian and are you from ITI or electrical engineer?
*Bhai motor to ac per chalti hai or ye Circuit aap ne 12v ka banaya hai pls motor se connect kar k dikha dain ku k main Confuse houn pls reply me... THANKS*
bulb ac py hi chala hai baki sircuit jo control ho raha ha wo dc sy ho raha hai i think
jo black ans Red wires arae hain wo ac hain ik direct bulb main r dusri relay sy ho k bulb main ja rahi ha
bhai thik hai bahaut logo ne bola hai motor ke saath connect karke dikhane keliye....
video next week mein banadunga....
bro battery wala option thik ni h kyoki jese hi battery khatam relay trigger ni krega or pump overflow krega practical kr Liya main se hi option btao leakage current zero kese kru please
Iss week mein ek wireless water monitoring ka video aane wala hai... please wait for 2 to 3 days.....
Lekin is systems se agar 1 centimeter be pani kam ho jayega to motor chalu ho jayegi ase hi continue tanki me se pani kam jyada hota raha to motor chalu band chalu band ho kar jal jayegi
Sir can I touch water in tank if circuit on
Isme Diode ka kya function h . jo 5v dia h wo q aur kaha se diya h?? plz thoda sa explain krdijiye
5v diya hai relay ko drive karne keliye...& diode use kiya hai transistor ko protect karne keliye because relay is an inductive load & it store energy
How much current in wire which is in contact with water
Why u have used diode there?
Plz can you tell me?
as you know relay is an inductive load which store energy so the voltage across the collector of the transistor goes very high which can damage the transistor that's why diode is use....
sir can I use 1 k resistor instead of 100 ohms resistor please give reply sir
Sir... Water me current nhi aye ga kiya...
Coloca nome dos componentes miserável, não é todo mundo que fala a mesma língua..
Bhai 2hp motor k liye konsa relay lu
Watch my latest video on this topic... You will understand... Check my channel
Dangerous System.
This is impractical..As soon as the water level.goes down the Pump is ON, then it goes OFF as soon as it filled, again it goes ON...etc never ending loop.
Anyway, thanks for video
Yes you are right... Please check my channel you will find your project.. I already made it.. Without microcontroller.....
Sir ,plase tell us that how you know that connection process , i mean how you know that which device has connected to which device, how to coonect with different terminals?
Watch my latest video on this topic...
good
Pani me de hui ware sorted nahi marega..?
Half hp sumersible motor me chalega
Sir i am connect 80ohm resister in 12 volt sypply what problem
thik hay thik hay
i have GKT78-DV12V-C 5V 250VAC 20A 14VDC relay,can work??
Charging ka in put keya karay.
Thank you sir
Low voice please tell loudly
Is is possible bc548
Yes
Current flow nehihoga kya
motor start manually karna parega, kyunki motor start upper level discunnect hote hi ho jayega to kya faida bar bar start ho jayega.
This circuit is useful for automatic turn off the motor....
Nice video
समरसीबल पंप का सरकट बताईये
Thik hai
And if 12 v relay then resistor??
Good sir
Nice bro
Thik hai..... Thik hai..... Thik hai.....
Super thousth
Current lagne ka khatra hai...puri tanki aur pipes me current askti hai
Vai amr...water label ektu komle jodi motor on hoya jai...tobe ki love???
thik ache bhai kintu motor on korar por tumi jodi otake off korte vule jao tahole je pani waste hobe seta ki thik hobe....
eta sudhu sei karonei banano.....
jai hok....tomar bari kothay......bangla te amar channel e comment pray dekha jay na.....
Can I use 9volt battery
Yes
Thank you so much
Nice video
Ye savie ha carnt to nhi lagy ga
मतलब एक वाल्टी पानी निकालते ही मोटर वार वार स्टार्ट होती रहेगी
What about for 3phase submersible water pump
Very simple three face conductor relay out conductor coil connection
to bhai is s to bar bar switching hogi motor khrab karwayega kya kisi ki
agar aap motor off karna bhul jate ho to uss case me yeh helpfull hai......
*Is relay per 1 HP ka motor nhi chalta hai.*
Uske liye heavy relay lgna pdega
Why Diod, Resister and Transistor requires please explain
diode stops reverse voltage resistor limits current & transistor works as switch
auto controller melagi khaha iska Praic kitna he
For 1.5Hp how much value of resistor I should use
ये बताओ कि पानी मे करेंट तो नही आये गा न
It will stop the motor at higher level but what is the minimum level you forget to to describe. It is not circuit for level control. Because when when water level go down even a millimetre the motor will start and in the next few seconds it will stop again.
hiiiiiii
Auto off hone ke bad apne aap on nahi honi chaiye iska diagram ya video share karo
Isme pani me carnt nahi ayega na ????
Apka Mo no dena
No
nice
Can we use 12v relay
+abdul basith of course you can... Justbuse 12v relay and 1k resistor....
How to calculate the resistor value of this circuit
Within how many days
1 nos Relay-40inr
1 nos Transistor-7inr
1 nos Resistance-1inr
Relay 16 inr
Transistor 3 inr
Resister 1 inr
Par bhai... Agar koi water use krta hai ghar me to again start ho jayegi motor agar kisi ne 500litre wali tanki me se 1bucket bhi water nikala.... . Agar hum na bhi start krna chahe motor... Ye to problem hai....
Mene asay ak banaiya. Malti mitar diya disting htahe
Are Bhai mene circuit correct banaya lekin me 2 wire water ke aandar ya bahar rakhta hu tab bhi bulb on hi rerehta he
Mera new video dekho...clear ho jayega....
Which one
Sorry I got it
I did this but it will on every minute after water level get down one inch also it will start
Electrical circuit diagram diagram is nessary to understand it 's function.
Very nice...
There is some problem, when tank is full it's going to turn off the motor, what happens when both wires are not touching water? Motor will run automatically. So motor will be continually on and off mode which makes motor to spoil very soon
Very good
logic is one sided not complete