Hello Guys It is Great to see you again on our channel forever tech we hope you always support our efforts because we can not run this channel with out your support good luck and have a nice day.
About this Video
In this Video we have a sharp inverter air conditioner which has stopped cooling after washing its outdoor unit and it runs for 5 minutes then stops so we are trying to find the reason behind it that what the problem could be and fix the problem.
And Subscribe the channel , Hit the like Button and share with others..
****************************************************************************************************
For Business Inquiries and Promotions Please Contact Us On Email : robin.nadeem@gmail.com
****************************************************************************************************
Social Media Links
..................................................................................
Facebook ▶bit.ly/36FbFgP
.....................................................................
Instagram ▶bit.ly/3oJcwDm
....................................................................
Twitter ▶ bit.ly/3atkbRl
....................................................................
Our Other Videos Playlist
Air Conditioner Basics/ Hvac basics Playlist
▶ bit.ly/36GtfRQ
Compressor Testing Playlist
▶ bit.ly/36JgkOZ
Automatic Washing Machine Repair Tricks Playlist
▶ bit.ly/3rj7Dmc
Dc Inverter Air Conditioners PCB Repairing Tips Playlist
▶ bit.ly/2YPIrr7
Electronic Component Testing
▶ bit.ly/39MQdbP
Washing Machine Basics
▶ bit.ly/3t9AGt7
Refrigerator Faults and problems
▶ bit.ly/3tcYE6D
.......................................................................
#Forevertech #ac #inverterac #airconditioner #hvac #acnotcooling #accleaning #dc #coolingproblem
Video ko Share zarror kardien Takke YAh information dusro tak bhi phonchaye.......
And Subscribe - bit.ly/2Xj8JkN
Dawlance double door deep freezer hai us ka thermostat tripp hi nahi karta dawlance company ne bhi new laga diye 2 baar magar woh nahi tripp horhe. Maine bhi original thermostat 161 num ka denfoss ka laga dia lekin us se bhi tripp nahi horaha. Or is deep freezer me thermostat fridge side pe hai . Freezer side pe nahi hai. Koi solution hai to batadein pls. Last yahi koshish ki thi 161 number ka thermostat laga kar k ye tripp kar jaye ga magar nahi horaha. Gas bhi sahi hai frigde me baraf bhi banti hai freezer bhi ok chill karta hai bus koi thermostat tripp nahi horaha. Company ne jo lagaye the woh bhi nahi karte the tripp. Customer k ghar ka hai kaam ye.
Beautiful information.
Thanks.thank.Thank
Good tiching karte hai 👍👌👌👌👌👌👌👍👍👍👍👍👍👌👌👌👌👌👌
Good information sir
Bhut sunder ji
Very good😊😊😊
Jazak allah sir
Sir.... 🙆 good.....ap ka fane ho gaya hon is fold pey......siloot hy ap ko mera....
Nice
Great
Mast vedios
Nice Bro
Good work
Thank you so much 😀
Good mr 👍
P.c.b nikala ho ga pora.is liye
Good a
👍
I thought you are from pakistan !
Good knowledge. Any solution of rust in evaporater and gas leakage due to waste drain near by .
sir is ka section pressure katna hona cheya plz sharp j tech 1.5ton kaa mara unit kaa 145psi ata ha or 10 amp lata ha kia ya thk ha full par
This is inverter model ac sir compelsery vaccum it
& It working was properly like old condition
Sir apka work shop kaha p ha
Me ne outdoor fan ke upher Pani dala hn ab Kam nhi Kar Raha Kia wajha hn
Sar Jo aap series board istemal karte ho uska review dal do
Hello sir I need your help. Ye kaha milega mujhe cahahiye
Sir outdoor sensors ki value bata sakte hai g
Thanks sir
Sir reply nhi kia aap ne important tha g
Almost 5k oms
Sir sharp d.c invertar ka fold hy... compreshar highy speed par aty he off ho jata hy. Fan motar bhe off ho jati hy hy.or off ho kar phir silow silow chalna start ho jati hy.compreyshar on nahi hota.phir thordi deyr bad on ho jata hy.or yehi masla karta hy.....sensor bhe thek hen sab..koch gaide kar den. 2 unit hen sharp k 2no he is fold mein hen. Hyderabad. Sindh
Dear i am using haier 1 ton inverter ac...
After cleaning the indoor coil. Its started a problem.
On turbo compressor doesn't speed up as before.
Secondly reduced cooling
Indoor coil is chilled from front but not chilled from top (bent) side.... Before this cooling was good but air flow was low....
Moreover. Liquid line there was ice on liquid line when compressor speed was slow... But after the speed up it vanished but low cooling is still a problem.
Please award me a solution
Sir ac koi utaar ke deta hai kyaa repair karne ke liye hai
I have kenwood inverter , it starts normal , but after sometime reduces cooling and fan noise sound increases and cooling down. i have also witnessed ice in the indoor coil
can you help me out
Dear aap indoor unit koo master service kar loo yah video daykhoo
ruclips.net/video/k9kDQ9A_VRY/видео.html
1.5 ton ka Inverter AC Agar impact 6 le raha hai to kya masala hai kya gas kam hai ismein ya theek hai
O general 1 ton inverter ac ka outdoor start ho kar 3 4 sec me band ho jata hai fir chalu ho kr 3 4 sec bad firse band ho jata hai
Outdoor pcb me micro blue light blink hota hai
Sir mere pass Dawlance ka 1 ton inverter ac hai
Start bilkul sahi hota hai 6 amperes tak max jata hai lekin phr 5 minutes Baad hi 2.5 ampere pe ajata desired cooling reach kiye baghair hi aur phr 2.5 amps pr hi chalta rehta jis ki waja se cooling Boht slow Hoti.. Kya reason ho sakta iska
Sir mery pas gree dc inverter 1.5 ton jab compressor apni pori spead pe ata hey 5n ka error de kr band hojata he or uski orange light bhi off hojati hey or red light musalsal blink krti rehti hey
🙏
Compressor bi kamzoor ho gaya hoga 5 gantay ON OFF ho ke
Ok ksk
Choti remote wali
Sir kya sabhi companies me dc inverter ac senser colour code same hota hai
Dear nahi har company apna design aur color code rakhti haye
@@ForeverTechh to kese pehchan kare sir g konsa senser kaha lagega
Dear channel par visit karien aur waha par sensor testing ki video dekhain ap ko samjh lag jaye gie
Dalawnce ac inverter 30 eror F1 Dy Raha..Kia prblm ha sir G
Outdoor kit problam
@@theanimalhouse36 thnku sir
Gas puri q nikal naa?
Top up nhi karsakte kya??
Plz aap yah videos daykhian
ruclips.net/video/j3T7r0BF5Js/видео.html
Sir mene ac service karway tha service k bad cooling low hogyi hai technician kahta h compressor m oil agya hai dubara gas se wash hoga.
Mjhe lagta h technician se gas leakage hogyi hai
Fan motor jeck.. Or outdoor fan motor jeck. Pcb jeck nikaal ke laga do. Chal jayega
Sir ek penasonic ki inverter ac hai usme problem hai aadha ghanta kabhi dus minut chalne ke baad timer ka red light balinck hone lagta hai ac nahi chalta hai
channel per visit karo aur panasonic per hamari videos majood hain panasonic play list main tamam videos mil jayin gee ka error kaysay maloom karna hai
Sir compressor 3 minute ke baad on hota hai lekin fhir band ho jata hai fhir 3 minute ke baad on hota hai fhir band ho jata hai Aise ho raha hai kya problem hai o general inverter ac hai
Dear Unit par is tarha indoor par blinking aye gie o general inverter ac unit par bhi
Sir ap logo ka contact no kiya hai. Mujhy apna ac ap sy repair krwana hai.
Mera sara kaam ac ki motor ka kaam h koi Shi bhi motor ho sab ho jaati h
Is outdoor mein koi aur company ka PCB lagakar chala kar dikhao sir
Isme kya problem thi gas ki yah sensor ki ? Yeh toh batao aap
Dono but main fault sensors ka hie tha.....
@@ForeverTechh kaun sa sensor problem kr rha tha outdoor me agar outdoor ka sensor problem karega toh error show kare disply pr.
Video ko gaur saye dekhien pura main naye btaya hai video maye
سروس کرنے کے لیے سینسر کھولنا تو ضروری نہیں ہوتا ۔ ٹیکنیشن نے سینسر کیوں کھولے ؟(
Pcb karab hogi sayad
yehi problem he magar sensor sahi lage hue hai error ye hi de raha he
Sir mere pass midea company ka dc inverter ac hai ,maine oski service ki thi , service se pehle bilkul ok tha lekin service krne k kuj din bd osme problem aa gyi, koi v erorr code v nhi aa rha ,but compressors on nhi ho rha company valo ne pcb fault btya hai ,what is problem sir g ,pcb proper voltage nhi nikl rhi ,plz help me sir
Iske sensor v check kr liye sbhi ok hai onko change krke v dekh liye
dear pcb per mery kafi videos majood hain muktalif problems per aap channel per visit kar kay kuch time videos choos kar kay daykhian aur pcb us kay mutabiq check karian kin kay is situation main kou be fault hoo sakta hai
@@ForeverTechh sir sharp invertor he 5+ 2 error he sensor sub sahi lage hai 20 min bad on off on off pe error de raha kindly help me
Mera to on hi nhi ho rha
হট ভিডি.
Tek a ma ka karoooo
Yar ap ajeeb type ka cho..ya insan ho youtube per channe, aur videos bqnqtay hoo to cimments ka jawqb be diya karo.