Bhai ese koi nahi bta skta vo depends krta he heat load pr agar heat load jyada hoga to peals jyada khulegi aur cooling ho jaigi to automatic km ho jaigi
❤❤❤❤❤❤❤❤❤❤❤❤❤😊😊 mashallah zabardast bhaijaan aap wese mujaffar nagar k rahne wale h aap aap ki lenguage bahut badhiya h aap apna kaam karte h ya job 3 month ka course karke 3 phase ka single phase aatah to wo karke assistant m sellery kitni milni chahiye plz reply
Bhai coded se isliye pta lgta he kyoki vo wire se pcb se connect hoti he aur wireless se isliye pta nahi lgta kyoki uske bich me kuchh nahi hota isliye hum wireless se bs comand de skte he
Bhai pcb indoor ki heng nahi krti aur agar vo faoulty ho gai to machine on condition me hogi to exv on hoga of condition me hogi to off hoga bs yahi he
Bhai 1 Circuit. 24 hp vrv and indoor AHU 2 UNIT mei F4-02 Eroor aa jata h 2 Din chalne k baad. Hmne Check kiya to expension body or Expension moter dono hi work kr raha h or AHU BHI CLEAN H.SENSER BHI SARE THIK HAI
Very very useful information thq
Shukriya bhai
Mashallah very nice 🙂
Expentoin wolv thik he body kharab thi 😊😊😊 nice
Good job 💯💯💯💯👍👍👍👍
Nice bro
Thank you so much ❤
Bilkul sahi
Good bhai👍
❤❤❤❤❤
Nice
Bhai expansion moter nhi Volvo hai . But good knowledge 👏
Bhai Volvo other brand me kehte honge but Daikin vrv me expansion motor ya motorized valve kehte he
Or
Bhai expansion valve kitne pulce open hona chahiye
Kam ya zyada hone se kya problem hoti hai
Bhai ese koi nahi bta skta vo depends krta he heat load pr agar heat load jyada hoga to peals jyada khulegi aur cooling ho jaigi to automatic km ho jaigi
❤❤❤❤❤❤❤❤❤❤❤❤❤😊😊 mashallah zabardast bhaijaan aap wese mujaffar nagar k rahne wale h aap aap ki lenguage bahut badhiya h aap apna kaam karte h ya job 3 month ka course karke 3 phase ka single phase aatah to wo karke assistant m sellery kitni milni chahiye plz reply
Bhai vrv new model wired remote ki all settings pa video banao jaise valve open ki
Bhai jis din moka Mila us din bna dunga aur setting vahi he Jo purani thi bs new remote ko chalana aana chahiye baki sb same he
Bhaiya aapse se call pe baat karni h
भाई वीडियो अच्छा लगा
मेरा एक सवाल हे आज कल wireless रिमोट लगाते हे उन में कैसे पत्ता करेंगे?
Bhai coded se isliye pta lgta he kyoki vo wire se pcb se connect hoti he aur wireless se isliye pta nahi lgta kyoki uske bich me kuchh nahi hota isliye hum wireless se bs comand de skte he
How to check in wire less remote
Bhai change karte hue video bana thi
Next time bhai jarur bnaounga
Bhai ek vrv system pe Suction line pe moisture bahut jyada aata jiske karn insulation ke upar pani aa jata hai kya ho sakata hai bhai
Bhai ye btao ek idu pr aa rahi he ya odu tk aa rahi he agar ek idu pr aa rahi he to ho skta he service required ho
Bhai pcb problem hone pr expansion valve work karta hai kya
Bhai pcb indoor ki heng nahi krti aur agar vo faoulty ho gai to machine on condition me hogi to exv on hoga of condition me hogi to off hoga bs yahi he
Or apne gas kaise band kari or expansion value kaise badla
Exv body kharab thi usko change kra he fir exv band hua he bhai
F4
Ji bhai
You can help me
Jarur btao bhai kiya problem hai
Bhai ye kitne reading tak jata hai nmbr
Ye 100 tk jati he aur agar ye chack krna he ke kitni puls khuli he to is velue to 50 se maltiply kr do
@@Vrvknowledgeadda magar bhai fan mode pa to value 20 ho gyi multiple 50 =1000 matlab fan mod pa 1000 open h
Bhai 1 Circuit. 24 hp vrv and indoor AHU 2 UNIT mei F4-02 Eroor aa jata h 2 Din chalne k baad.
Hmne Check kiya to expension body or Expension moter dono hi work kr raha h or AHU BHI CLEAN H.SENSER BHI SARE THIK HAI
Odu me chack karo kiya vakai me low digree ka refrigerant aa rah he ya nahi
Jb hum check krne jate h to sb normal rahta h
Machine ko observation me rakho
Bhai aapse baat ho sakti h
Btao bhai kiya hua
No send me bro
Nice bro
Nice bro
Nice bro