How to calculate CFM of AHU in Hindi | HVAC World

Поделиться
HTML-код
  • Опубликовано: 8 сен 2024

Комментарии • 110

  • @Mohammad.faizan.technical
    @Mohammad.faizan.technical 4 месяца назад +2

    Today i got best informative channel to know about HVAC

  • @surajambure
    @surajambure Месяц назад +1

  • @shahnawazhafsani1021
    @shahnawazhafsani1021 3 года назад +1

    Thanks a lot your explanation method is wonderful. I like it

  • @taiyabansari9795
    @taiyabansari9795 4 года назад +1

    Very informative video...Thank You sir

  • @jagdishoberoi5134
    @jagdishoberoi5134 3 года назад +1

    Very nice brother good job

  • @umarfarooque1600
    @umarfarooque1600 5 лет назад +1

    Bhut achchi videi hai

  • @vinayaknehe379
    @vinayaknehe379 3 года назад +1

    thanks sir ji

  • @jitendrakumar-lu2wy
    @jitendrakumar-lu2wy Год назад

    Very nice sir 👌

  • @shahabuddin6983
    @shahabuddin6983 4 года назад

    Very nice sir, please upload the next video of this

  • @khanmohammedazam3382
    @khanmohammedazam3382 4 года назад

    Bahut Kaam Ki Vedio Hai

  • @VIKRAMSINGH-pr3jl
    @VIKRAMSINGH-pr3jl 3 года назад

    Awesome sir

  • @mayurbhaithakor7986
    @mayurbhaithakor7986 2 года назад +1

    👌

  • @shahzadmajahiri4690
    @shahzadmajahiri4690 3 года назад

    Iske super jaldi video banaiye

  • @raeesahamad5915
    @raeesahamad5915 3 года назад

    Super

  • @HVACWorld
    @HVACWorld  4 года назад +2

    I used 4 here For finding total area of All 4 filters.....

  • @ponkrapujari679
    @ponkrapujari679 4 года назад +2

    👍

  • @musharrafhafiz8496
    @musharrafhafiz8496 Год назад

    Thnx

  • @susheelrajput4312
    @susheelrajput4312 3 года назад +1

    Sir please tell about how to deside the static pressure of ahu

  • @jeddy_KAG_heartbeat
    @jeddy_KAG_heartbeat 3 года назад +2

    Sir iam ac department m job krta hu .. from AIIMS jodhpur 🙏

    • @HVACengineer93
      @HVACengineer93 3 месяца назад

      Are bhai tmse baat krni h ..plz mereko contact kro mai bhi AC department mai hu

  • @brijeshkumar7633
    @brijeshkumar7633 3 года назад +1

    Is it correct way to find CFM on HEPA filters or LAF filters.
    Or the best way to find is how you explained in the video.

    • @HVACWorld
      @HVACWorld  3 года назад

      You can take measurements whatever filter is

  • @sheikhasadahmed2857
    @sheikhasadahmed2857 3 года назад +2

    Excellent video! I want to make an egg incubator, for which I need to know, how to calculate the equipment (fan) requirement for the incubator. Really appreciate, if you could help me in this regard.

  • @Shiv.kumar92
    @Shiv.kumar92 2 года назад +1

    I think discharge flow will be high compared suction Flow

  • @kaushikshiva7852
    @kaushikshiva7852 3 года назад

    sir apart from theory hvac calculation part topics kya kya hotha hein sir for mep technician in hvac

  • @Alone_AshutoshAniket
    @Alone_AshutoshAniket 3 года назад +1

    Sir,agar filter different size ka hua to @hvacworld

  • @gauravdixit3537
    @gauravdixit3537 3 года назад

    dear sir,
    kisi kisi AHU me 10% fresh air jate he vaki recycle hote he tab inlet aur out let air pressure me difference hoga

  • @k.p.pranav7356
    @k.p.pranav7356 4 года назад +1

    The device to check the velocity should be kept back or front of the filter?

    • @HVACWorld
      @HVACWorld  4 года назад

      Anemometer should be kept back of the filter from where Return Air is coming... in this week you will get the video of Live demonstration of CFM calculation of AHU...sorry for the delay because of personal issue

    • @k.p.pranav7356
      @k.p.pranav7356 4 года назад

      @@HVACWorld no problem... Your work is amazing.. Lots of skills and knowledge we r getting.. We r waiting for ur many more videos..

  • @sheikhirfan65
    @sheikhirfan65 3 года назад +1

    What are the books that you refer to get the complete knowledge of HVAC??

    • @raginisahu5854
      @raginisahu5854 3 года назад +2

      Basic of refrigeration and AC by Mr.Annanthnarain is the best book

  • @supertechnician961
    @supertechnician961 Год назад

    Chacha kitni area mai kitne capacity ka ahu laga sakte hai??

  • @thakurkapil4071
    @thakurkapil4071 4 года назад +1

    AHU m deferential pressure switch or pressure switch with tubing kese krte h or location kya rhti h

    • @HVACWorld
      @HVACWorld  4 года назад

      Sir DP Switch duct k End me lagate hai....DP switch ki positive bwali tube duct k andar dalte hai or negative wali tube bahar nikalte hai jisse k duct or room key andar ka pressure difference measure ho sake fir ye signal VFD ko jata hai jisse VFD frequency ko Kam ya zyada krta hai jisse AHU ki speed Kam ya zyada hoti hai

  • @er.minhajali410
    @er.minhajali410 3 года назад

    Ek site hai usme package ac laga hua hai aur duct se connect hai aur usme diffuser laga hua hai to usme anemometer se kaise air balance kre ge pls baataao bro

  • @VIVEKKUMAR-9955
    @VIVEKKUMAR-9955 2 года назад +1

    Limit such cnecsn

  • @aazanaircon
    @aazanaircon Год назад

    Sir Diffuser Collar & Grill Collar me se kitna cfm nikal raha hai wo kaise calculation karna hai.

  • @IrfanKhan-yb5vt
    @IrfanKhan-yb5vt Год назад

    Pahle design CFM check karenge aur freshair se check karenge ki utna design CFM mil raha hai ki nhi uske bad age saphly CFM check karenge 👍

  • @mohammedriyaz223
    @mohammedriyaz223 Год назад

    Return ka air velocity kam ata hai equal Nahi raheta thoda raheta hai hamesha,,,,👈👆👆👆

  • @kamalsonu4987
    @kamalsonu4987 4 года назад +1

    How to measure negative pressure in room

  • @sgmechanical7565
    @sgmechanical7565 4 года назад +2

    Sir humre yaha ak AHU h jiska model number DM2N1319
    Serial number 1409118
    Air flow 6318L/S
    Motor capacity 11kw.
    Ye kitne to ton ka h please reply with solution.. please

  • @avinashkolhe5208
    @avinashkolhe5208 3 года назад

    Sir ji jab filter 610mm ka hey to directly 2x2 karo mins 4sqft

  • @shashikantrajak7101
    @shashikantrajak7101 4 года назад +1

    Sir , how to calculate supply grill size in ft2

    • @HVACWorld
      @HVACWorld  4 года назад +1

      I will share my fb page account in my next video...aap waha pe message kre apke sare doubt clear ho jayege

    • @shashikantrajak7101
      @shashikantrajak7101 4 года назад

      Thanks

  • @arbazpathan6714
    @arbazpathan6714 4 года назад

    Sir iska calculation step by step karke dikhaoan sir

  • @syed.quayumurrahman3129
    @syed.quayumurrahman3129 Год назад

    Hello Kai se pata knre ki AHU kit ne TR Ka hai

  • @satyamjaiswal5561
    @satyamjaiswal5561 3 года назад +1

    No multiplying factor...? I think there should be multiplying factor for Anaemometer..like 10 , 20..

    • @HVACWorld
      @HVACWorld  3 года назад

      Multiplication factor used where least count of anemometer is 10 ft/min. We are using anemometer whose least count is 1 ft/min

  • @atikurrahman233
    @atikurrahman233 2 года назад +1

    How to control RH in rooms?

  • @Tech_Gaurav
    @Tech_Gaurav 4 года назад +1

    Hi....

  • @Shiv.kumar92
    @Shiv.kumar92 2 года назад +1

    Damper will close during fire.
    Saying something wrong

    • @HVACWorld
      @HVACWorld  2 года назад

      No...AHUs fire damper Will be closed during fire

  • @krishnakumarjhajha3729
    @krishnakumarjhajha3729 4 года назад

    Duct and pipe balance check ko testing kaise karen

  • @Nadeemali-ou2bp
    @Nadeemali-ou2bp 10 месяцев назад

    Sir aapne one filter area galat liya hua
    .610x.610x10.76= 4.0037 Sqft hota

  • @sanjeevtiwari3912
    @sanjeevtiwari3912 9 месяцев назад +1

    .61*.61*10.76=4.003

    • @HVACWorld
      @HVACWorld  7 месяцев назад

      I substracted the filter frame size from filter size

  • @shahzadmajahiri4690
    @shahzadmajahiri4690 3 года назад

    Darling ka mejarment kaise nikalte ha aor nsksha kaise dekgte hai please batadijye

  • @hardikjoshi7224
    @hardikjoshi7224 3 года назад

    But give an clarification that pre filter

  • @javediqbal4693
    @javediqbal4693 2 месяца назад

    How to rectify CFM device

  • @abudawood3136
    @abudawood3136 4 месяца назад

    Bhai traverse kaise Lena hai

  • @bhaskardas4516
    @bhaskardas4516 Год назад +1

    Ap Angrezi kisi Professor se Dhang se Skhiyes

  • @himanshumadhwal3357
    @himanshumadhwal3357 2 года назад +1

    I think constant u have given is not right one

    • @HVACWorld
      @HVACWorld  2 года назад

      10.76 to convert meter square to feet square

  • @razakhan9842
    @razakhan9842 3 года назад

    Velocity calculate krte hue Anemometer k reading m multiplying factor s multiply nhi kia apne???

  • @Hirendiwani4
    @Hirendiwani4 4 года назад +1

    Anemo meter na hoto velocity measure kese kare??

    • @HVACWorld
      @HVACWorld  4 года назад +1

      Velocity measuring instruments k bina velocity kaise measure kar sakte....anemo meter, pitot tube , hot wire anemometer , capture hood type anemometer..inme se koi sa v instruments hona chahiye apke pass

  • @vinaykumar-dl1vc
    @vinaykumar-dl1vc 4 года назад +2

    Pretical kab Aaey ga

    • @HVACWorld
      @HVACWorld  4 года назад +1

      Sorry friend....mai personal kaam ke bzy tha...ab continue video upload krta rhunga...

  • @shakilkhan7435
    @shakilkhan7435 2 года назад +1

    What is 4 ?

  • @Behuman0627
    @Behuman0627 4 года назад +2

    Sir practical video nhi aya apka!! Pls

    • @HVACWorld
      @HVACWorld  4 года назад +2

      Sorry friend....mai personal kaam ke bzy tha...ab continue video upload krta rhunga...

  • @asifhussainasifhussain6455
    @asifhussainasifhussain6455 5 лет назад +1

    Fpm Kia hota h or kesy measure kartey h

    • @HVACWorld
      @HVACWorld  5 лет назад +1

      FPM= Foot per minute
      FPM (Foot per minute) velocity ki unit hai jise measure krne k liye anemometer ka use krte hai.... practically kaise reading lete hai ispe video Kal ane wali hai..

    • @asifhussainasifhussain6455
      @asifhussainasifhussain6455 5 лет назад +1

      @@HVACWorld ok sir please thanks

    • @HVACWorld
      @HVACWorld  5 лет назад

      My pleasure 😊

  • @joydipghosh3273
    @joydipghosh3273 4 года назад

    why you use 4 ???it is for 4 filter..but why we use 4 because already we make average of all 4 filter .

  • @tarjanprajapati
    @tarjanprajapati 2 года назад +1

    Your name sir

  • @k.p.pranav7356
    @k.p.pranav7356 4 года назад +1

    Sir, in calculation when we convert Sq meter to foot in Google.. We r getting answer 6.565 Sq foot... So which is correct the way your calculation or frm Google??

    • @HVACWorld
      @HVACWorld  4 года назад

      1 meter square = 10.76 ft square...you can cross check it anywhere..either in Google or in books

    • @k.p.pranav7356
      @k.p.pranav7356 4 года назад +1

      @@HVACWorld Okay sir U r rite 1 sq meter = 10.76 sq ft... then for 0.61 sq meter = (0.6x10.76)= 6.565 sq ft

    • @HVACWorld
      @HVACWorld  4 года назад +1

      Very good.... don't trust anyone either me or Google.. first do self cross check

    • @mohammedsaadsaqibareeba9889
      @mohammedsaadsaqibareeba9889 3 года назад

      yes 10.76 sq ft

  • @bhaskardas4516
    @bhaskardas4516 Год назад +1

    Sahi Uchcharon vi nehi ata hay spko

    • @HVACWorld
      @HVACWorld  Год назад

      Thanks for your feedback

  • @Educational685
    @Educational685 5 лет назад +1

    AHU ka tr kaise nikalte hai

    • @shailendrapal5157
      @shailendrapal5157 4 года назад +1

      400 cfm =01tr

    • @HVACWorld
      @HVACWorld  4 года назад

      Shailendra ji 400 CFM =1 Tr ye thumb rule hai.... Actual TR nikalne ka formula hai...water or air dono side se nikala ja skta hai...

  • @karelalrajpal
    @karelalrajpal 3 года назад

    Area calculations not to clear me

  • @mohitbobade9417
    @mohitbobade9417 2 года назад

    Blowre ke bad coil ati hai

    • @HVACWorld
      @HVACWorld  2 года назад

      FCU me hota hai aisa....AHU me filter k baad coil or uske baad blower hota hai

  • @nishasudhan8501
    @nishasudhan8501 3 года назад

    .61x.61x 10.76 how much bro?

    • @sumentkumar1088
      @sumentkumar1088 3 года назад

      Mention dimensions also...like meter/CM/Inch

  • @atulkumarsingh485
    @atulkumarsingh485 Год назад

    10 ka gura kyo karti hi

  • @kavyagahlot5046
    @kavyagahlot5046 2 года назад

    .61*.61*10.76=4 sq feet ban rha ha apne 3.61 sq feet likha h