  • In this video, we will talk about the repair of hybrid inverters, where to start when searching for malfunctions. The video is aimed at beginners, not professionals. For those people who want to repair the inverter themselves, or at least diagnose it.
    Useful links
    ✔ Transistors from verified sellers on Ali
    MBQ60T65PES - IGBT t.ly/MBQ
    G60T60AK3HD IGBT t.ly/G60
    YGW40N65F YGW60N65F IGBT t.ly/YGW
    NCE82H140 MOSFET t.ly/nce
    NCEP15T14 MOSFET t.ly/Nce
    IRFB4110PBF MOSFET t.ly/irf
    📟 Measuring and testing devices 📟
    T7 transistor tester t.ly/tT7
    HV transistor tester 120-2700V t.ly/tHV
    Clamp-multimeter HT208D t.ly/htd
    UNI-T multimeter pliers t.ly/Uni
    Thermal imager KAIWEETS KTI-W01 t.ly/KTI
    Internal tester battery resistance YR1035+ t.ly/1035
    Internal tester RC3563 battery resistance t.ly/RC3
    Electronic load DL24 t.ly/DL2
    Automatic battery tester EBC-A20 t.ly/ZKE
    Automatic battery tester EBC-A40 t.ly/ZKe
    Portable oscilloscope ET120M t.ly/osc
    📺 Playlist with videos on measuring devices t.ly/vym
    🔌☀️ Solar hybrid inverters with MPPT.
    Battery charge from the sun and the network. Adulteration.
    Uninterruptible power supply. 🔌☀️
    ☀️Easun SMH 2.2-7kW 24/48V t.ly/Eas
    ☀️PowMr 1.5/3kW 12/24V t.ly/pw1
    ☀️PowMr 4.2/6.2kW 24/48V t.ly/pw2
    ☀️PowMr 10.2kW 48V t.ly/pw3
    ☀️ECGSOLAX 1.0/1.5kW 12/24V t.ly/Ecg
    ☀️ECGSOLAX 4.2/6.2kW 24/48V t.ly/EcG
    ☀️GROWATT 6.0kW 48V t.ly/Gro
    ☀️EPEVER MPPT control. 10-40А t.ly/Epe
    📺 Playlist with video reviews and tests
    solar hybrid inverters t.ly/Sol
    🔌🔋 Inverters 12-48V/220V car. plan.
    The nominal power is indicated. Clean sinus.
    🔌 Worthy. 12-48V/220V/2.5kW t.ly/in1
    Testing the 12V version t.ly/IN1
    Testing the 24V version t.ly/IN2
    🔌TOP DATOU. 12-48V/220V/2kW t.ly/in2
    Video with tests t.ly/IN3
    🔌DATE. 12V/220V/1kW t.ly/in3
    Video with tests t.ly/IN4
    🔌Baseus 12V/220V. 500W t.ly/in5
    Video with tests t.ly/IN6
    🔌 Budget. 12-24V/220V/1.5kW t.ly/in4
    Video with tests t.ly/IN5
    📺 Playlist with videos on inverters t.ly/inV
    🛠️ Tools and auxiliary equipment 🛠️
    Laboratory power supply t.ly/lbp
    Spot welding Docreate t.ly/wel
    Dynamometric nozzle 2-200Nm t.ly/mxi
    Digital microscope AD209 t.ly/ANd
    Crimp for wires 6-50mm2 t.ly/50b
    Hydraulic press 4-70mm2 t.ly/YQK
    📺 Playlist with videos on instruments t.ly/Ins
    ⚙ Periphery ⚙
    Wattmeter for a 220V outlet t.ly/Wtm
    Din-rail wattmeter t.ly/DIN
    Tips for the bolt t.ly/lug
    Silicone wires 1-26AWG t.ly/Syl
    Power wires pressed 0-8AWG t.ly/Dri
    Anderson Power Connector t.ly/ande
    Cigarette lighter 12V + USB t.ly/Soc
    Soft start for pumps t.ly/Sof
    AVR automatic generator t.ly/ats
    Gas. generator carburetor t.ly/GAZ
    Wi-Fi machine with wattmeter t.ly/Wif
    📺 Playlist with videos on the periphery t.ly/Per
    🛡⚡ DC protection and switching 🛡⚡
    Automatic machine Tomzn 2P MC 100-250A t.ly/DCA
    Automatic machine Tomzn 1/2P 100-250A t.ly/DCF
    Automatic machine Tomzn 2P Din 80-125A t.ly/DCB
    Automatic machine Tomzn 1P Din 80-125A t.ly/DCH
    Automatic machine Tomzn 2P Din 3-63A t.ly/DCC
    20-200A fuse + MIDI case t.ly/DCD
    30-500A fuse + MEGA case t.ly/DCE
    📺 Playlist with videos on DC protection t.ly/DCV
    ⚡ Chargers ⚡
    Charger 12-200V 600W (regulation I,U) t.ly/cg4
    Charger 12-220V 1.5kW (regulation I,U) t.ly/cg6
    Charger 12V 6A t.ly/Cg1
    Charger 12V up to 100A t.ly/cg2
    Rechargeable 24V t.ly/cg3
    Charger Liitokala 1.2-3.7V t.ly/cg5
    📺 Playlist with videos on charging devices t.ly/cgv
    🛡🔋 Battery protection boards (BMS) for Lifepo4, Li-ion, LTO 🛡🔋
    JK (Jikong) BMS t.ly/JKB
    JK (Jikong) BMS of the new generation t.ly/JKN
    LCD displays for JK BMS t.ly/JKD
    100Balance BMS t.ly/B100
    Daly BMS t.ly/Dly
    BMS 100A (aluminum substrate) t.ly/BMs
    📺 Playlist with videos on BMS t.ly/BMS
    🔋 Aliexpress, Alibaba Lifepo4 batteries 🔋
    Lifepo4 battery 12/24V 100-300Ah t.ly/ak1
    Lifepo4 battery 48V 5-15kWh t.ly/ak2
    Lifepo4 cells EVE 90-310Ah t.ly/ak3
    Lifepo4 33140/15Ah t.ly/ak4
    Lifepo4 Alibaba EVE 50-280Ah offer.alibaba....
    📺 Playlist with videos on LFP, etc. AKB t.ly/LFP
    Support the channel t.ly/don

Комментарии • 320

  • @Vladyslav_M
    @Vladyslav_M  Год назад +6

    *Корисні посилання*
    ✔ *Транзистори від перевірених продавців на Ali*
    MBQ60T65PES - IGBT t.ly/MBQ
    G60T60AK3HD IGBT t.ly/G60
    YGW40N65F YGW60N65F IGBT t.ly/YGW
    NCE82H140 MOSFET t.ly/nce
    NCEP15T14 MOSFET t.ly/Nce
    IRFB4110PBF MOSFET t.ly/irf
    📟 *Прилади для вимірювання і тестування* 📟
    Тестер транзисторів Т7 t.ly/tT7
    HV тестер транзисторів 120-2700V t.ly/tHV
    Кліщі-мультиметр HT208D t.ly/htd
    Кліщі-мультиметр UNI-T t.ly/Uni
    Тепловізор KAIWEETS KTI-W01 t.ly/KTI
    Тестер внутр. опору АКБ YR1035+ t.ly/1035
    Тестер внутр. опору АКБ RC3563 t.ly/RC3
    Електронне навантаження DL24 t.ly/DL2
    Автоматичний тестер АКБ EBC-A20 t.ly/ZKE
    Автоматичний тестер АКБ EBC-A40 t.ly/ZKe
    Портативний осцилограф ET120M t.ly/osc
    📺 Плейлист з відео по вимірювальним приладам t.ly/vym
    🔌☀ *Сонячні гібридні інвертори з MPPT.*
    Заряд АКБ від сонця і мережі. Підмішування.
    Джерело безперебійного живлення. 🔌☀
    ☀Easun SMH 2,2-7kW 24/48V t.ly/Eas
    ☀PowMr 1.5/3kW 12/24V t.ly/pw1
    ☀PowMr 4.2/6.2kW 24/48V t.ly/pw2
    ☀PowMr 10.2kW 48V t.ly/pw3
    ☀ECGSOLAX 1.0/1.5kW 12/24V t.ly/Ecg
    ☀ECGSOLAX 4.2/6.2kW 24/48V t.ly/EcG
    ☀GROWATT 6.0kW 48V t.ly/Gro
    ☀EPEVER MPPT контр. 10-40А t.ly/Epe
    📺 Плейлист з відеооглядами і тестуваннями
    сонячних гібридних інверторів t.ly/Sol
    🔌🔋 *Інвертори 12-48V/220V автомоб. плану.*
    Вказана номінальна потужність. Чистий синус.
    🔌Достойний. 12-48V/220V/2.5kW t.ly/in1
    Тестування 12V версії t.ly/IN1
    Тестування 24V версії t.ly/IN2
    🔌ТОП DATOU. 12-48V/220V/2kW t.ly/in2
    Відео з тестуваннями t.ly/IN3
    🔌DATOU. 12V/220V/1kW t.ly/in3
    Відео з тестуваннями t.ly/IN4
    🔌Baseus 12V/220V. 500W t.ly/in5
    Відео з тестуваннями t.ly/IN6
    🔌Бюджетний. 12-24V/220V/1.5kW t.ly/in4
    Відео з тестуваннями t.ly/IN5
    📺 Плейлист з відео по інверторам t.ly/inV
    🛠 *Інструменти і допоміжне обладнання* 🛠
    Лабораторний блок живлення t.ly/lbp
    Точкова зварка Docreate t.ly/wel
    Динамометрична насадка 2-200Nm t.ly/mxi
    Цифровий мікроскоп AD209 t.ly/ANd
    Обжимка для дротів 6-50мм2 t.ly/50b
    Гідравлічний прес 4-70мм2 t.ly/YQK
    📺 Плейлист з відео по інструментам t.ly/Ins
    ⚙ *Периферія* ⚙
    Ватметр для розетки 220V t.ly/Wtm
    Ватметр на Din-рейку t.ly/DIN
    Накінечники під болт t.ly/lug
    Силіконові дроти 1-26AWG t.ly/Syl
    Силові дроти опресовані 0-8AWG t.ly/Dri
    Силовий роз'єм Андерсон t.ly/ande
    Прикурювач 12V + USB t.ly/Soc
    Плавний запуск для насосів t.ly/Sof
    Автомат АВР для генератора t.ly/ats
    Газ. карбюратор для генератора t.ly/GAZ
    Wi-Fi автомат з ватметром t.ly/Wif
    📺 Плейлист з відео по периферії t.ly/Per
    🛡⚡ *DC захист і комутація* 🛡⚡
    Автомат Tomzn 2P MC 100-250A t.ly/DCA
    Автомат Tomzn 1/2P 100-250A t.ly/DCF
    Автомат Tomzn 2P Din 80-125A t.ly/DCB
    Автомат Tomzn 1P Din 80-125A t.ly/DCH
    Автомат Tomzn 2P Din 3-63A t.ly/DCC
    Запобіжник 20-200А+корпус MIDI t.ly/DCD
    Запобіжник 30-500А+корпус MEGA t.ly/DCE
    📺 Плейлист з відео по DC захисту t.ly/DCV
    ⚡ *Зарядні пристрої* ⚡
    Зарядний 12-200V 600W (регул I,U) t.ly/cg4
    Зарядний 12-220V 1.5kW (регул I,U) t.ly/cg6
    Зарядний 12V 6A t.ly/Cg1
    Зарядний 12V до 100А t.ly/cg2
    Зарядний 24V t.ly/cg3
    Зарядний Liitokala 1.2-3.7V t.ly/cg5
    📺 Плейлист з відео по зарядним пристроям t.ly/cgv
    🛡🔋 *Плати захисту акумуляторів (BMS) для Lifepo4, Li-ion, LTO* 🛡🔋
    JK (Jikong) BMS t.ly/JKB
    JK (Jikong) BMS нового покоління t.ly/JKN
    LCD дисплеї для JK BMS t.ly/JKD
    100Balance BMS t.ly/B100
    Daly BMS t.ly/Dly
    BMS 100A (алюм. підложка) t.ly/BMs
    📺 Плейлист з відео по BMS t.ly/BMS
    🔋 *Aliexpress, Alibaba Lifepo4 акумулятори* 🔋
    Lifepo4 батарея 12/24V 100-300Ah t.ly/ak1
    Lifepo4 батарея 48V 5-15kWh t.ly/ak2
    Lifepo4 комірки EVE 90-310Ah t.ly/ak3
    Lifepo4 33140/15Ah t.ly/ak4
    Lifepo4 Alibaba EVE 50-280Ah offer.alibaba.com/cps/pi8je8b6?bm=cps&src=saf&productId=1600488487843
    📺 Плейлист з відео по LFP та ін. АКБ t.ly/LFP
    *Підтримати канал* t.ly/don

    • @mykolagg706
      @mykolagg706 Год назад

      Розкажіть як ви спалили інвертор і про захист (запобіжники...) які потрібно встановити для безпечної роботи

    • @Vladyslav_M
      @Vladyslav_M  Год назад +1

      @@mykolagg706 було багато різних тестів сонячного входу після яких інвертор згорав мінімум 3 рази. Основна причина - подача на МППТ енергії без обмеження по струму, або неправильний розрахунок точки МППТ контроллером. Більшість тих тестів є на відео ruclips.net/video/6L7hZM7Ceb8/видео.html
      По запобіжниками і автоматам хочу відзняти пару відео. Якраз є для тестів трохи різних DC автоматів. Також ще буде відео саме по захисту як максимально убезпечити інвертор. Як тільки все буде в наявності і буде вільний час.

    • @user-oo7nw5eo9v
      @user-oo7nw5eo9v 8 месяцев назад

      Доброго дня.
      Потрібна допомога з ремонтом powmr 3.2
      Дайте Ваші контакти.

    • @user-nikolya302
      @user-nikolya302 Месяц назад

      Добрый день
      Вы сейчас занимаетесь ремонтом гибридных инверторов?

  • @user-no9cg7bu8m
    @user-no9cg7bu8m Год назад +23

    Дякую за вашу працю, та що тратите свій час на це.

  • @andriygaletski638
    @andriygaletski638 Год назад +6

    Дуже багато корисної інформації. Дякую за ваш час та роботу.

  • @bilyyoleg1272
    @bilyyoleg1272 Год назад +5

    Слава Україні! Дякую за якісні відоси! Так тримати!

    • @Vladyslav_M
      @Vladyslav_M  Год назад

      Героям Слава! Дякую.

  • @taraspavlyk4932
    @taraspavlyk4932 Год назад +7

    Як завжди РЕСПЕКТ! Досить швидко Ви набрались натхнення його ремонтувати)).
    Радий, що той гібридник знов серед "живих")).
    Теж перевернув вентилятори, але з'явився звук турболентності від того, що лопаті дуже близько проходять повз решітку(. Буду її випилювати і ставити грилі.

    • @Vladyslav_M
      @Vladyslav_M  Год назад +3

      Дякую. Та поки транзистори отримав, поки наважився. Ще й 6.2квт ремонтував)

  • @ODmitr
    @ODmitr 4 дня назад

    Дякую Вам, було цікаво

  • @Car_DoctoR
    @Car_DoctoR Год назад +5

    Дякую друже! Дуже корисно! МОЛОДЕЦЬ ... Слава Україні.

    • @Vladyslav_M
      @Vladyslav_M  Год назад +1

      Дякую! Героям Слава!

  • @igbt-service3818
    @igbt-service3818 Год назад +5

    Дякую за відео! Особлива подяка за телеграм-чат з тематики інверторів. Донедавна віднайти якусь технічну інформацію стосовно ремонтів інверторів (схеми, мануали тощо) можна було лише на іноземних форумах. А тепер маємо вітчизняний ресурс. Але у відео треба зазначати, що копіювання дій з нього з академічним рівнем знань електроніки "бачив на RUclips" може призвести до непередбачуваних наслідків. Потім їх доводиться переремонтовувати.

    • @Vladyslav_M
      @Vladyslav_M  Год назад +2

      Дякую! На відео якраз наголошував, що є вірогіднсть зробити гірше, якщо не знати що саме робити. Воно інколи наче знаєш що робиш, а візьме і піде не по плану)

    • @cb_q
      @cb_q Год назад

      ага, ремонт інвертора за три дні і зав'язнути з ним на роки)
      не підкажете адресу телеграм каналу?

    • @Vladyslav_M
      @Vladyslav_M  Год назад +1

      @@cb_q t.me/VM_YT

  • @Edelweiss_-rb8kz
    @Edelweiss_-rb8kz Год назад +5

    Дякую за роботу.

    • @Vladyslav_M
      @Vladyslav_M  Год назад

      Дякую за коментар

  • @ihorzinchenko2489
    @ihorzinchenko2489 Год назад +3

    Автор великий молодець,. Комент для підтримки канала.

  • @igorkvachun3572
    @igorkvachun3572 Год назад +5

    Вітаю. 👍 Інформативно-демонстаційно цікаве відео. ⚡🔌🔋💡

  • @ViktorGI.
    @ViktorGI. Месяц назад +2

    Дякую за україномовний технічний контент!

  • @igoronlym3358
    @igoronlym3358 Год назад +3

    Дякую за роботу!

    • @Vladyslav_M
      @Vladyslav_M  Год назад

      Дякую за коментар

  • @Bohdan_vasylenko
    @Bohdan_vasylenko Год назад +1

    Доброго дня! Дякую Вам за відео, інформативно . Хотів би з Вами звʼязатись .

    • @Vladyslav_M
      @Vladyslav_M  Год назад +1

      Доброго дня. В описі до каналу є пошта. Але попереджаю, що ремонтами я не займаюсь)

    • @Bohdan_vasylenko
      @Bohdan_vasylenko Год назад

      @@Vladyslav_M пошта не працює, (Ваша)

    • @Vladyslav_M
      @Vladyslav_M  Год назад

      Має працювати. Може помилились символом?

  • @andrew74k
    @andrew74k 3 месяца назад

    Дякую вам за гарний урок по ремонту.В мене теж згоріли мосфети на БМС жиконг,замовив на аліекспресі замінив,але є проблема з зарядкою акума

    • @Vladyslav_M
      @Vladyslav_M  3 месяца назад

      Напевно десь ще проблема в колах керування. Але нажаль в мене мало досвіду щоб щось конкретне порадити.

  • @user-pn3hd4yg8m
    @user-pn3hd4yg8m 7 месяцев назад +3

    Добрий день Чи можете поділитися детальною схемою що з Вами поділився колега. Дякую за контент - Українська мова це прекресно!

    • @Vladyslav_M
      @Vladyslav_M  7 месяцев назад +3

      Добрий день. Дякую.
      Детальна схема інвертора 3кВт drive.google.com/file/d/1ABEI3BDl0_Aj2Mo6i8WOiuRvm7qBUTsC/view?usp=drive_link Пан Василь особисто її змалював з реального інвертора. Подякувати Василю за схему можна за посиланням send.monobank.ua/7ZAsawoo1A
      Загальна принципова схема до інвертора 3кВт. drive.google.com/file/d/1KcK8nqVjxBSNNBwuSozRpnlWj-dVI-m1/view?usp=drive_link

  • @user-nf1ky7zv4e
    @user-nf1ky7zv4e 2 месяца назад

    Дякую за Вашу роботу

  • @chekmez
    @chekmez 11 месяцев назад +2

    Дякую за чергове цікаве відео.
    Придбав і собі 5квт інвертор. Підключив інвертор, між інвертором (на вході) і мережею поставив диф автомат Eaton HNB-C20/1N/003. Але іноді, в абсолютно різний час, ніби випадково його вибиває. При цьому сумніваюсь що це через велике навантаження, тому що таке часто буває вночі, коли споживання мінімальне, а батарея повністью заряджена. Буває цілу добу все нормально, а потім пару раз на добу виб"є.Може хтось стикався з таким і щось порадить? Дякую

    • @Vladyslav_M
      @Vladyslav_M  11 месяцев назад

      Зустрічав про такі проблеми, скоріш за все доведеться прибрати диф і встановити звичайний автомат.

  • @Gotway.
    @Gotway. Год назад +2

    Благодарю 🙏

    • @Vladyslav_M
      @Vladyslav_M  Год назад

      Дякую за коментар!

  • @user-hg5ys3rv6j
    @user-hg5ys3rv6j Год назад +1

    Дякую за Вашу працю, саме чекаю на транзистори з Китаю, другий раз вигорають при зарядцi акумулятора, мабуть щось не правильно роблю, можливо через BMS. Думаю глядачi будуть вдячнi ще бiльше, якщо подiлитесь схемою ;)

    • @Vladyslav_M
      @Vladyslav_M  Год назад

      Дякую. Ввечері буду з комп'ютером скину посилання.

    • @Vladyslav_M
      @Vladyslav_M  Год назад +1

      Детальна схема drive.google.com/file/d/1ABEI3BDl0_Aj2Mo6i8WOiuRvm7qBUTsC/view?usp=drive_link
      І загальна принципова drive.google.com/file/d/1KcK8nqVjxBSNNBwuSozRpnlWj-dVI-m1/view?usp=drive_link
      Дякую пану Василю за цю схему. Він особисто її змалював з реального інвертора. Подякувати пану Василю за схему можна за посиланням send.monobank.ua/7ZAsawoo1A перерахувавши будь-яку суму автору схеми. Адже подібну схему не вийде намалювати за один чи декілька днів. Тут дуже багато годин кропітливої праці.

  • @andriykhmara9892
    @andriykhmara9892 Год назад +1

    Коментар в підтримку каналу

  • @YuryMoose
    @YuryMoose Месяц назад

    Ви можете ремонтувати за допомогою дешевого DT, або дорогого Fluke, навіть Ц-ешкі. Справа не в обладнанні, справа в мозгах та в освіті. В мене був на обслуговуванні об'єкт, так там за мной постійно ходила людина та записувала всі мої дії. Але це їм не допомогло коли я пішов, а вони зі своїми записками залишилися.
    Тут приємно дивитися на роботу колег - електронщиків. А лозунги "може відремонтувати кожен" - хибні, вони для ламків більш біди нароблять...

    • @Vladyslav_M
      @Vladyslav_M  Месяц назад

      Так, згоден. Знання потрібні хоч мінімальні.

  • @user-te7eu6rt3c
    @user-te7eu6rt3c 2 месяца назад +2

    З мого досвіду- вмикання і вимикання інвертор треба проводити при неактивних навантажувачах.

    • @igorscarabey9527
      @igorscarabey9527 2 месяца назад

      Застосування АВР має допомогти інвертору не вийти з ладу по причині зустрічної напрузі???

  • @trublin
    @trublin 12 дней назад

    Дуже цікаве відео, дякую. Маю такий же інвертор, тільки на 10 кВт і наступну проблему: все працює добре (тільки світлодіодні лампи, коли вимкнені легенько мерехтять), але електромобіль не заряджається (виставив мінімальний струм). У зарядному пристрої постійно клацає реле і заряд вибиває за кілька секунд-хвилин, інколи з помилкою завищеного струму.
    Чи можливо це через "шуми" в синусоїді? І чи може допомогти в цьому випадку якийсь фільтр?

  • @user-gi6dh5fx2x
    @user-gi6dh5fx2x Месяц назад

    Дякую за інформацію, в мене є питання в аналогічному інвенторі гріється доріжка яка іде з верхнього полігону біля транзисторів з (-) батареї на полігон біля дежурного транса і до плавного запуску проходить вона знизу на платі виділено білим вона тонка і дуже сильно нагрівається що аж краска злізла і видно оголену мідь але інвентор повноціно працює лише є проблема з тим що на вході PV при роботі є напруга 24-28 вольт переміки вона попадає на панелі і тим самим гаситься на заземлення панелей якщо заземлення панелей відключити між землею та дахом 24-28 вольт перемінки підскажіть в чому може бути проблема варістори не пробиті

  • @crealpet972
    @crealpet972 2 месяца назад

    Low side keys connected mostly in parallel groups. Only milliohmmeter can detect really dead, while on board checking.

  • @shadow_war
    @shadow_war 7 дней назад

    А як що нема на силової шині 400v+- .Дивитися микруху u13 і транзюк Q41 ???

  • @user-yk4hm3dw9b
    @user-yk4hm3dw9b Год назад +1

    Люблю спостерігати за вашими діями,з мене лайк!
    А підкажіть будьласка,якщо до виходу перетворювача з чистою синусоїдою, підєднати конденсатор великого габариту 10мкФ 450вольт МБГТ то, чи не завадить це роботі перетворюва і чи посилить це пусковий ток,наприклад пуску холодильника?

    • @Vladyslav_M
      @Vladyslav_M  Год назад

      Дякую. Напевно я би не пробував встановлювати конденсатори. Навряд вони допоможуть при пуску холодильника. Але то лише моя думка.

    • @user-yk4hm3dw9b
      @user-yk4hm3dw9b Год назад

      @@Vladyslav_M Дякую за відповідь.

  • @user-mt7pv4nz7c
    @user-mt7pv4nz7c Месяц назад

    Сьогодні друг приніс такий самий. Я любитель, у мене одна відповідь: гірше не зроблю, але і гарантій не даю))
    Я йому у 2022році робив уже перетворювачі(зустрічна напруга)
    Із цим ще не знаю що. Із слів його, що це сестри, а що скоїлось...мовчать кляті партизани.

    • @Vladyslav_M
      @Vladyslav_M  Месяц назад +1

      Може бути поганий пропай затворних резисторів, перевірте. Або банально від погоди на марсі і після заміни транзисторів і попутніх елементів може нормально працювати навіть роками. Ще запитайте чи бмс часом не могла відключити АКБ при великих струмах заряду. Також може вийти з ладу (не часто, але буває). І так як по входу живлення АКБ скоріш за все зараз КЗ треба перевірити чи з БМС все добре (яко звісно це літієва АКБ).

    • @user-mt7pv4nz7c
      @user-mt7pv4nz7c Месяц назад

      @@Vladyslav_M Так, батарея із електпособіля.
      На вході КЗ, ще не розбирав, сильно спекотно в ,,майстерні"
      Завтра раненько піду, доки спека не почалась.
      Дякую за допомогу!
      Успіхів Вам, та миру!

    • @user-mt7pv4nz7c
      @user-mt7pv4nz7c Месяц назад

      @@Vladyslav_M Перевірив, всі транзистори пробиті, що по низької лінії, що по високій, зірваних немає.
      Транзистори скоріше за все неякісні.
      NCE 82H140
      YGW 40N65F1

    • @Vladyslav_M
      @Vladyslav_M  Месяц назад

      Та, ні транзистори загалом нормальні. При нормальній роботі інвертора працюють добре. Багато такі купував і встановлював.

  • @borisvvp85
    @borisvvp85 10 месяцев назад +2

    Доброго дня. Дуже подобаються всі ваші відео. Подивився це і вирішив спробувати відремонтували свій PowMr на 3кВт. В мене по входу батареї КЗ. Один з низьковольтних транзисторів NCE84H140 розлетівся так що корпус навпіл. Інші мабуть пробиті. А ще не дзвониться трансформатор 401-070020-00G. І якось він негарно виглядає - на жовтій ізоляції катушки якісь чорні плями. Підкажіть будь ласка як зрозуміти що це за трансформатор і як знайти йому заміну? Питав дядка Google але він не зміг допомогти)

    • @Vladyslav_M
      @Vladyslav_M  10 месяцев назад +1

      Доброго дня. Дякую. Транзистори дзвоніть, випаюйте. А трансформатор напевно для гальванічної ізоляції сигналів від процесора. Навряд від згорів, але все може бути. Темні плями то напевно лак

    • @borisvvp85
      @borisvvp85 9 месяцев назад +1

      Завдяки вашому відео відремонтувал свого 3кВт малюка) дуже багато корисної інформації у вашому відео. Ще б вигадати як його захистити від невдалих перехідних процесів... Дивився ваш відос про надшвидкі запобіжники але я так зрозумів то більше не захист а варіант зменшити кількість пробитих транзисторів якщо щось станеться

    • @vrm6415
      @vrm6415 3 месяца назад +1

      В мене подібна ситуація: ввечері інвертор працював, а вранці вже був вибитий 150а автомат по входу 24 в, вночі сталося КЗ без явної причини, навантаження на інвертор теж не було. Віддіав на ремонт, сказали що низьковольтні транзистори під заміну. А у вашому випадку була причина КЗ по входу батареї? В чому причина цієї несправності ?

  • @user-kw4hq8kq3z
    @user-kw4hq8kq3z 4 месяца назад

    Доброго вечора. Проконсультуйте будь ласка. Позавчора зібрав СЕС. Інвертор soyosours 1200 грід, панелі Trina Solar 425w - послідовно 3 шт . Робоча напруга інвертора 120-180В. Це вже був вечір і він встиг виробити 2кВт. Сьогодні побачив що енергія не генерується. Заміряв напругу з панелей - 0. Думав щось з панелями. Відключив автомат - усе гаразд (138В).
    Питання: це КЗ із за перенавантаження по току? (інвертор підєднується у розетку перед токовим трансформатором) .
    Прикро що ви не займаєтесь ремонтом, а в мене досить поверхневі знання в електроніці.
    З чого почати ремонт?

  • @crealpet972
    @crealpet972 2 месяца назад

    Possible use this invertor as Online UPS, if attach to PV input grid voltage via rectifier? Im interest for tolerance such devices with using in tandem with gasoline generator )

  • @uaserdar
    @uaserdar Год назад

    Все чудово, крім відсутності адреси в описі. Свій буду ремонтувати тільки за тією адресою. Мій ще працює(поки).

    • @Vladyslav_M
      @Vladyslav_M  Год назад

      Яка адреса? :)

    • @uaserdar
      @uaserdar Год назад

      @@Vladyslav_M Наприклад НП...

    • @volodymyrzakolodyazhny7740
      @volodymyrzakolodyazhny7740 Год назад +1

      ​@@uaserdarздається, аатор не займається реионтом. Це відео - чисто в пізнавальних цілях.

    • @Vladyslav_M
      @Vladyslav_M  Год назад

      @@volodymyrzakolodyazhny7740 так, все вірно. Дякую.

  • @malysh86
    @malysh86 2 месяца назад

    Доброго дня. А ви не підкажете які трансформатори стоять? Скільки витків, яка товщина провода? А схема то титанічна праця)) Подяка за схему.

    • @Vladyslav_M
      @Vladyslav_M  2 месяца назад

      Доброго дня. По трансформаторам нічого не підкажу, не розбирав, не перемотував.

  • @user-iw9rt8ny5h
    @user-iw9rt8ny5h 9 месяцев назад

    Дуже пізновально дякую. підскажіть будьласка де можно знайти інструкцію схему , вмене POW-HVM3.0KW-24V виникла проблема від мережи заряджає акум, а від акума щось цикає і я так зрозумів не стартує на виході скачить 220 немає постійно, майже усе перевірив не можу знайти у чому проблема, є думка шо якийсь смд вмер чи єлектроліт. Може щось підскажете буду дуже вдячний.

    • @Vladyslav_M
      @Vladyslav_M  9 месяцев назад +1

      Доброго дня.
      Детальна схема інвертора 3кВт drive.google.com/file/d/1ABEI3BDl0_Aj2Mo6i8WOiuRvm7qBUTsC/view?usp=drive_link Пан Василь особисто її змалював з реального інвертора. Подякувати Василю за схему можна за посиланням send.monobank.ua/7ZAsawoo1A
      Загальна принципова схема до інвертора 3кВт. drive.google.com/file/d/1KcK8nqVjxBSNNBwuSozRpnlWj-dVI-m1/view?usp=drive_link
      Загальна принципова схема до інвертора 6.2кВт. drive.google.com/file/d/1fP8a9dsouOJyz28EQZN3VFZjukoEzuf9/view?usp=sharing Схеми мають деякі неточності, можуть бути помилки.
      Стосовно вашого інвертора треба розбирати, перевіряти, може дійсно є якийсь непропай.

  • @user-go8sp3mz2q
    @user-go8sp3mz2q 8 месяцев назад

    Порекомендуйте інвертор приблизно 6-7кв який працює без акб

    • @Vladyslav_M
      @Vladyslav_M  8 месяцев назад

      Еасан 6.2квт s.click.aliexpress.com/e/_DlMsxlj
      І більш потужний 8.2квт s.click.aliexpress.com/e/_DmQu2xj

  • @user-jg6hu6ih2u
    @user-jg6hu6ih2u 2 месяца назад

    Доброго дня. Підкажіть будь ласка Гібрид Must PH18-3024 Plus, MPPT при різних напругах бачить і споживає лише 270Вт. Підключаю дві панелі по 540 Вт., напруга 82-88 В 270 Вт, підключаю одну панель, напруга 37-39 В 270 Вт. Ввечері менше бере, а в яскравий сонячний день не більше 270 Вт.

  • @igorkuc956
    @igorkuc956 6 дней назад

    в моєму інверторi 3 кВт стоять паралейно Q38,Q37 - 24N90, по схемі стоїть один Q38 - МР50N65, можливо запустити з одним 24N90?

    • @Vladyslav_M
      @Vladyslav_M  6 дней назад +1

      Точно не знаю, треба порівнювати всі параметри. Але часто бачу, що китайці ставлять транзистори які є в наявності і параметри у них можуть трохи відрізнятись. Тому думаю що можна спробувати.

  • @mihalmelaj8542
    @mihalmelaj8542 2 месяца назад

    Підключити на вхід 220 конденсатор пусковий як фільтр буде працювати привідключенні.

    • @mihalmelaj8542
      @mihalmelaj8542 2 месяца назад

      Потрібна мені схема натакий інвертор 12в1.5кв.
      Вякого продавця замовляти транзистори низьковолтні і які.

    • @Vladyslav_M
      @Vladyslav_M  2 месяца назад +1

      Детальна схема інвертора 3кВт drive.google.com/file/d/1ABEI3BDl0_Aj2Mo6i8WOiuRvm7qBUTsC/view?usp=drive_link Пан Василь особисто її змалював з реального інвертора. Подякувати Василю за схему можна за посиланням send.monobank.ua/7ZAsawoo1A
      Загальна принципова схема до інвертора 3кВт. drive.google.com/file/d/1KcK8nqVjxBSNNBwuSozRpnlWj-dVI-m1/view?usp=drive_link
      Загальна принципова схема до інвертора 6.2кВт. drive.google.com/file/d/1fP8a9dsouOJyz28EQZN3VFZjukoEzuf9/view?usp=sharing Схеми мають деякі неточності, можуть бути помилки.
      оці транзистори можете використати NCE82H140 MOSFET t.ly/nce
      Гарний продавець. Або гляньте які точно у Вас стояли.

    • @toshibamaster2210
      @toshibamaster2210 Месяц назад

      @@Vladyslav_M дякую за сему а взагалі мЄрзость . сонячні панелі гальванично звязані з мережою

  • @user-cg2jc8pr3c
    @user-cg2jc8pr3c Месяц назад

    Добрий день. Скажіть будь ласка, чи можна використовувати спільний нуль для входу і виходу інвертора. На схемі вхід нуля зєднаний з виходом через дросель.

    • @Vladyslav_M
      @Vladyslav_M  Месяц назад

      Добрий день. І можна і не можна. Якщо об'єднаємо, то дросель не буде працювати. Краще тоді нуль просто брати із вхідної клеми (для живлення інвертора і для живлення споживачів).. Тоді при роботі від мережі дросель не буде замкнутий і буде працювати.

    • @user-cg2jc8pr3c
      @user-cg2jc8pr3c Месяц назад

      @@Vladyslav_M дякую за відповідь.

  • @orbit489
    @orbit489 Месяц назад

    Доброго дня .А якщо інвертер пустити через стабілізатор на вході? Тоді є можливість що він не згорить? І якої потужності його купити?

    • @orbit489
      @orbit489 Месяц назад

      Інвертер 5.6 кВт

  • @user-go8sp3mz2q
    @user-go8sp3mz2q 8 месяцев назад +1

    Підкажіть будь ласка який з інверторів працює без акб

    • @Vladyslav_M
      @Vladyslav_M  8 месяцев назад +1

      Моделі 3.6 квт і вище. Але краще перевіряйте що вказано в описі до товару. В описі до відео є посилання на різні інвертори. Моделі 3.2квт і менше в 95% випадків не працюють без акб.

  • @user-qd3gt2lw9s
    @user-qd3gt2lw9s Год назад +1

    Слава Україні.

  • @andorius85
    @andorius85 11 месяцев назад

    Доброго вечора Владислав! Маю такий інвертор + 6 панелей по 570Вт+ АКБ (40 шт елементів лужних АДС KL-300P, з'єднані по 20 послідовно і в паралель, тобто 600Агод - 14,4кВтгод) Працює система 2 тижні, при моїх спробах імітувати відсутність мережі (робота від АКБ) видає помилку 52 і потрібно перезавантажувати з від'єднанням АКБ. Від мережі та сонця працює чудово. Сьогодні вперше під час роботи від сонця та мережі видав помилку 52, потім ще через годин 5. Перезавантажив поки працює. Може маєте якусь пораду?

    • @Vladyslav_M
      @Vladyslav_M  11 месяцев назад

      Доброго вечора. 52 помилка, як вже напевно бачили, вказує на низьку напругу високовольтної шини. Тому або напруга дійсно провалюється на шині, або не коректно вимірюється і інвертор видає помилку. В будь-якому випадку схоже на апаратну проблему і потрібно втручання у інвертор.
      Яка у Вас максимальна напруга виходить з батареї? Близько 30В?

    • @andorius85
      @andorius85 11 месяцев назад

      @@Vladyslav_M Доброго дня! Почав частіше входити в помилку просто при роботі від сонця та мережі, особливо коли мало сонця, чи може так співпадає? Буду напевно лізти в схему. АКБ заряджається до 31,5В а потім підтримується на рівні 27В. Навантажував батарею на баласт струмом 85-90А напруга майже не просідає. Можете поділитись схемою даного інвертора?

    • @Vladyslav_M
      @Vladyslav_M  11 месяцев назад

      @@andorius85 Доброго дня. Як варіант, спробуйте зменшити bulk напругу до 30В. Чим менша напруга заряду АКБ тим менша напруга має бути на високовольтній шині (це не 100% інформація). І може банально спрацьовувати захист.
      Детальна схема інвертора 3кВт drive.google.com/file/d/1ABEI3BDl0_Aj2Mo6i8WOiuRvm7qBUTsC/view?usp=drive_link Пан Василь особисто її змалював з реального інвертора. Подякувати Василю за схему можна за посиланням send.monobank.ua/7ZAsawoo1A Загальна принципова схема до інвертора 3кВт. drive.google.com/file/d/1KcK8nqVjxBSNNBwuSozRpnlWj-dVI-m1/view?usp=drive_link

    • @andorius85
      @andorius85 11 месяцев назад

      @@Vladyslav_M Дякую Вам, пану Василю теж подякував ₴! Буду гратись.

  • @PanDa-lp9ly
    @PanDa-lp9ly 13 дней назад

    Чи робите ви ремонти, якшо вам відправити паціента. (Повмр 2.4, код помилки 57 та 9) Подали напругу на вихід...

    • @Vladyslav_M
      @Vladyslav_M  12 дней назад

      Ні, не займаюсь.

  • @andreymelnyk4541
    @andreymelnyk4541 Год назад

    Дякую за цікаве відео.У мене такий самий інвектор, мене цікавить з якою макс. потужністю у вольтах можна підключити акумулятор до нього.У мене акумулятор літій з напругою 31v, 7s тому незнаю чи потягне даний інвектор чи не згорить.

    • @Vladyslav_M
      @Vladyslav_M  Год назад

      Дякую. Інвертор точно не згорить. 7s нормально підходить. Заявлений макс заряд до 31.5В

    • @andreymelnyk4541
      @andreymelnyk4541 Год назад

      @@Vladyslav_M Дуже дякую.

  • @virusc22
    @virusc22 Год назад +1

    Вопрос от чайника - что нужно делать чтобы они не горели ))

    • @Vladyslav_M
      @Vladyslav_M  Год назад

      Ввечері відпишусь)

    • @MediaServicedpua
      @MediaServicedpua Год назад

      Купити інвертор а не його макет 😂

    • @Vladyslav_M
      @Vladyslav_M  Год назад +3

      Із того що я обрав для захисту - реле напруги по входу в будинок. 2х полюсний автомат перед інвертором (бажано з характеристикою B і без зайвого запасу по струму). І 2 запобіжники (на фазу і на нуль) також без запасу по струму з характеристикою gR - швидкодіючі для напівпровідників від іменитих фірм. По виходу інвертора (на навантаження) напевно також бажано автомат + швидкодіючі запобіжники. По батареї DC автомат по плюсу батареї і запобіжник по мінусу.
      Також не бажано допускати великих пускових струмів. Якщо інвертор розрахований наприклад на 3квт і від при роботі від АКБ навантаження вже 2.5квт то запуск насосу свердловини в теорії може призвести до виходу з ладу інвертора. На сонячний вхід не можна перевищувати номінальний робочий струм і підключати що-небудь окрім сонячних панелей.

  • @user-hd5mc8zb6f
    @user-hd5mc8zb6f 8 месяцев назад

    Вітаю. Виникла проблема з інвертором 12-220, двохконтурний котел який працював від нього почав вимикатися (йде в захист), на пряму від розетки працює справно. Інвертор наче справний, інші прилади від нього працюють (пробував вмикати блендер), а котел працює пару хвилин і вимикається.

    • @Vladyslav_M
      @Vladyslav_M  8 месяцев назад

      Вітаю. Може котлу потрібна чітка фаза і нуль? Чи раніше цим інвертором котел працював?!

    • @user-hd5mc8zb6f
      @user-hd5mc8zb6f 8 месяцев назад

      @@Vladyslav_M раніше працював.

    • @Vladyslav_M
      @Vladyslav_M  8 месяцев назад

      Тоді бажано перевірити сигнал осцилографом на виході інвертора. Може там якісь спотворення синусоїди. Або спробуйте один із виходів інвертора занулить до мережі.

    • @user-hd5mc8zb6f
      @user-hd5mc8zb6f 8 месяцев назад

      @@Vladyslav_M дякую. Спробую.

  • @moi-pryhody
    @moi-pryhody 2 месяца назад

    Добрий день. Хороше та пізнавальне відео. Маю подібний інвертор, той же бернд, але меншої потужності. На днях спалив модуль пережачі джаних rs232. Там згорів трансформатор, трохи подиміло. По вашому відео перевірив всі транзистори, немає пробитих. Візульано інших підгорань немає. Відключив цей модуль і тепер як думаєте, можна підключати 24В живлення і вмикати інвертор? ЧИ можливо ще на щось варто звернути увагу?

    • @Vladyslav_M
      @Vladyslav_M  2 месяца назад +1

      Добрий день. Дякую. Скоріш за все можна включати без даного модуля. Бачив не один інвертор зі згореним модулем. Його відключають і все нормально працює.

    • @moi-pryhody
      @moi-pryhody 2 месяца назад

      @@Vladyslav_M Ще підкажіть. Зараз підключив від лабораторного БЖ живлення. Інвертор стартує, починає видавати 220В, але через секунд 5-10 показує помилку 04 (мала напруга на акумуляторі). Виставляв різну напругу, від 24В до 25.5В, але результат такий самий. Що можна перевірити?

    • @moi-pryhody
      @moi-pryhody 2 месяца назад

      @@Vladyslav_M І ще у мене проблема, що я вимикаю інвертор вимикачем, але він працює і екран горить, доки не вимкну живлення з акумуляторного входа. Хоча інвертор сам не вмикається, якщо живлення підключити.

  • @VD111-y5h
    @VD111-y5h 21 день назад

    Прохання порадити - в чому може бути проблема? інвертор поврмр 3.2квт. при підключенні до мережі частоту показує, а напругу ні. мигає зелений діод, інвертор працює від акумулятора і не заряджає його, на екрані іконка мережі мигає.

    • @Vladyslav_M
      @Vladyslav_M  18 дней назад

      Можливо апаратна проблема в колах вимірювання напруги. Там є ряд послідовних резисторів, через які вимірюється напруга. Може бути непропай.

    • @VD111-y5h
      @VD111-y5h 18 дней назад

      @@Vladyslav_M дякую

  • @user-kw4hq8kq3z
    @user-kw4hq8kq3z 4 месяца назад

    Vladyslav а у вас часом немає на продаж мережевого сонячного інвертора 4+ кВт? Бажано 24В . Можливо із відремонтованних.

    • @Vladyslav_M
      @Vladyslav_M  4 месяца назад +1

      Ні, немає. Ремонтами фактично не займаюсь, тому і запропонувати немає чого.

  • @vctech4954
    @vctech4954 Месяц назад

    Nice great you...share please complete circuit digram

    • @Vladyslav_M
      @Vladyslav_M  Месяц назад +1

      3kW inverter circuit drive.google.com/file/d/1ABEI3BDl0_Aj2Mo6i8WOiuRvm7qBUTsC/view?usp=drive_link
      General schematic diagram for the 3 kW inverter.drive.google.com/file/d/1KcK8nqVjxBSNNBwuSozRpnlWj-dVI-m1/view?usp=drive_link
      General schematic diagram for the 6.2 kW inverter.drive.google.com/file/d/1fP8a9dsouOJyz28EQZN3VFZjukoEzuf9/view?usp=sharing
      Schemes have some inaccuracies, there may be mistakes.

    • @vctech4954
      @vctech4954 Месяц назад

      @@Vladyslav_M very thanks brother...god bless you

  • @mihalmelaj8542
    @mihalmelaj8542 2 месяца назад

    Вигорів транзистор Q5 випаяв Q1 Q3 Q6 біля трансформатора т3 т4. Безних можна запускати інвертор POW-HVM1.5H-12V від акамулятора?

    • @mihalmelaj8542
      @mihalmelaj8542 2 месяца назад

      Причина поломки.
      Призаряді від сіті, відключив і включив акамулятор.

  • @user-yk4hm3dw9b
    @user-yk4hm3dw9b Год назад

    І підкажіть будьласка ще,де можна шукати схеми?

    • @Vladyslav_M
      @Vladyslav_M  Год назад

      Детальна схема drive.google.com/file/d/1ABEI3BDl0_Aj2Mo6i8WOiuRvm7qBUTsC/view?usp=drive_link
      І загальна принципова drive.google.com/file/d/1KcK8nqVjxBSNNBwuSozRpnlWj-dVI-m1/view?usp=drive_link
      Дякую пану Василю за цю схему. Він особисто її змалював з реального інвертора. Подякувати пану Василю за схему можна за посиланням send.monobank.ua/7ZAsawoo1A перерахувавши будь-яку суму автору схеми. Адже подібну схему не вийде намалювати за один чи декілька днів. Тут дуже багато годин кропітливої праці.
      А так схеми можна шукати в інтернеті, є деякі сервісні мануали, але не на всі моделі.

  • @user-kl3gp8wp7o
    @user-kl3gp8wp7o 2 месяца назад

    А хіба можна інвертор до мережі підключати однополюсним автоматом?

    • @Vladyslav_M
      @Vladyslav_M  2 месяца назад +1

      В цією моделі нуль не розривається вбудованим реле, тому думаю можна.

  • @user-ft5kp7uq5b
    @user-ft5kp7uq5b 14 дней назад

    В мене проблема в тому що не зникає помилка 58 а транзистори всі цілі.

    • @Vladyslav_M
      @Vladyslav_M  13 дней назад

      А яка фактична напруга на виході інвертора? При запуску інвертора вона починає хоч збільшуватись?

  • @bdfybdfy100
    @bdfybdfy100 2 месяца назад

    візьметесь за ремонт TOMMATECH PLUS 5.6KW 48V відвалилась індикація на екрані , при робочому інверторі підєднали шлейф той що на кришці?

    • @Vladyslav_M
      @Vladyslav_M  2 месяца назад

      Ні, не займаюсь ремонтами.

  • @user-jh3sw7kv4u
    @user-jh3sw7kv4u 2 месяца назад

    Доброго вечора
    Чи займаєтесь ремонтом гібридних інверторів pow mr 3200 як у вашому відео.
    Маю проблему підключили генератор на вихід з інвертора .
    І як з вами зв'язатися щодо ремонту
    Дякую

    • @Vladyslav_M
      @Vladyslav_M  2 месяца назад

      Доброго вечора. Ні, не займаюсь ремонтами.

  • @user-mv1cd8jy4j
    @user-mv1cd8jy4j 11 месяцев назад

    Підкажіть, а яку напругу на виході виставити 220, 230 чи 240вольт? З теорії чим менша напруга тим менше споживання, так як опір однаковий. Виходить якщо 220в виставлено можна більше навантаження дати, тобто чайник не 2,4 кВт буде, а 2квт, насос глибинний на старті менше буде давати перевантаження при запуску. Чи можете протестувати?

    • @Vladyslav_M
      @Vladyslav_M  11 месяцев назад +2

      В теорії краще забезпечити більшу напругу і при однаковому струмі можна буде зняти більшу потужність з інвертора. Я точно не знаю чи обмеження захисту йде по потужності чи по струму. Мені здається що по струму, це було би логічніше. Але протестувати зараз немає на чому. Коли буде на чому протестую, також цікаво.

  • @igorscarabey9527
    @igorscarabey9527 2 месяца назад

    Порадьте як уникнути зустрічної напруги. Інвертор працює, але важкувато усвідомлювати що це може колись статися.

    • @Vladyslav_M
      @Vladyslav_M  2 месяца назад

      Просто живіть і не думайте про це. Таких випадків насправді не дуже багато. Є певні думки, але треба тестувати. Планую ще окреме відео, коли буде вільний час.

  • @WarMusic2022
    @WarMusic2022 Год назад

    Якби збирати систему безперебійного, а потім альтернативного живлення, Ви радите цей контролер чи іншого виробника. При одних і тих самих праматрах.
    І чи радите перед початком експлуатації робити апгрейт (заміну термопрокладок, внтилятора, термодатчику на вентилятор, тощо)?

    • @Vladyslav_M
      @Vladyslav_M  Год назад +1

      Стосовно інвертора powmr 3квт - це напевно найдешевше, що можна придбати на сьогоднішній день, ціна близько 200$ без wi-fi. Чи брати якусь іншу модель в приблизно схожому ціновому діапазоні? Я не знаю, але на скільки я бачив, вони всередині всі майже ідентичні, або дуже схожі, з мінімальними відмінностями. Тільки різні кольори корпусів і дисплеї. Тому я би не переплачував за інший бренд в ціновій категорії скажімо до 500дол за 3квт інвертор. Якщо мова взагалі про ТОП рівень - то можете розглядати Деє, Хуавей та інші імениті бренди. Але там вартість вже більша ніж 1.5тис. дол. Я цей 3квт хочу встановить батькам, а собі придбав powmr на 6.2квт. Ціна зараз 360 дол без wi-fi. А далі буде видно, може колись перейду і на щось більш брендове.
      Із апгрейда можна встановити плати регулювання обертів вентиляторів ruclips.net/video/Q-VFa1Xtm-0/видео.html
      Ще можна розібрати і перевірить чи добре прижаті транзистори до радіаторів, за потреба піджати болти. До прокладок я би не ліз взагалі, тільки якщо буде ремонт.

    • @WarMusic2022
      @WarMusic2022 Год назад

      @@Vladyslav_M дякую за слушну думку. 200$ це тут в Україні чи там у дядечка Мао?))

    • @Vladyslav_M
      @Vladyslav_M  Год назад +1

      В Китаї 200$, інколи навіть трохи дешевше. В Україні близько 300-350$

  • @user-yj1wt6qc7j
    @user-yj1wt6qc7j 7 месяцев назад

    Доброго дня. Можете підказати проблема з інвертором бачить панелі і напругу на них але не бере струм. Напруга 200 в. Модель VMII PLUS 3.5KW - 24V

    • @Vladyslav_M
      @Vladyslav_M  7 месяцев назад

      Доброго дня. А по налаштуванням все коректно? Пріоритет заряду 16 параметр і живлення навантаження 1 параметр? 16 наприклад OSO і 1й SBU.

  • @user-ob4uz4tb8n
    @user-ob4uz4tb8n 10 месяцев назад

    Доброго дня. В мене є міні 3 ф гідроелектростанція. Чи можна подати на вхід для сонячних панелей випрямлений струм після зф діодного мосту. Чи треба ще щось доробляти?

    • @Vladyslav_M
      @Vladyslav_M  10 месяцев назад

      Доброго дня. Якщо захочете реалізувати подивіться це відео ruclips.net/video/6L7hZM7Ceb8/видео.htmlsi=G3GuvenV86o340Ql може передумаєте, або хоча б зробите менше помилок ніж я.

  • @user-eg2jr4ln6s
    @user-eg2jr4ln6s 2 месяца назад

    Вітаю і дякую за працю. Маю схожий інвертор і в високовольтному колі не 350В а 700В після відновлення транзисторів кола низької напруги. Також згорів діод і транзистор контролю заряду - поки не впаював. Чи можете прокоментувати про причину? дякую

    • @user-eg2jr4ln6s
      @user-eg2jr4ln6s 2 месяца назад

      Розібрався. Без навантаження в вигляді електролітичного конденсатора звичайний тестер показує неправильні дані, збільшені. Після підключення навантаження - 415В. Ще раз дякую авторові за матеріал, крутий))

    • @Vladyslav_M
      @Vladyslav_M  2 месяца назад

      Дякую. Добре що розібрались.

  • @chukandgek
    @chukandgek 9 месяцев назад

    Доброго дня. Що може бути якщо режим інвертора працює, але не дає зарядку на акумулятор? при тому що режим байпасу працює, на екрані відображається всі вольтажі від мережі та від панелей? а вот зарядка не йде

    • @Vladyslav_M
      @Vladyslav_M  9 месяцев назад

      Доброго дня. Може десь в режимах роботи є конфлікт?

  • @woodyatv3600
    @woodyatv3600 10 месяцев назад

    Добрий день. Купив такий самий інвертор і є одна проблема, це велика різниця в напругах зарядки АКБ, інвертор пише що АКБ 29В, а фактично 25.2В. поставив напруга зарядки 31.5В тобто максимум, але це не домогло щоб АКБ заряджався повністю. Може підскажите як можна вирішити питання?

    • @Vladyslav_M
      @Vladyslav_M  10 месяцев назад

      Добрий день. Досить велика розбіжність в напругах. Нажаль нічого не підкажу. Спробуйте звернутись до продавця, або в службу підтримки powmr.

  • @Denis-rk9zg
    @Denis-rk9zg Год назад

    Цікавить, чи можуть ці 24 вольтові інвертори працювати із збірками літій іонних акумуляторів 6s, тобто, чи можна максимальну напругу зарядки виставити дещо меньшу ніж 25 V?

    • @Vladyslav_M
      @Vladyslav_M  Год назад +1

      6s виходить не оптимально і по нижній і по верхній межі. 7s ідеально

  • @user-iq2uh9bh9w
    @user-iq2uh9bh9w 2 месяца назад

    Доброго дня у меня такаяже проблема у меня вопрос вы сможете отремонтировать

    • @Vladyslav_M
      @Vladyslav_M  2 месяца назад

      Доброго дня. Ні, ремонтами не займаюсь.

  • @user-cr8tb8yy7e
    @user-cr8tb8yy7e 3 месяца назад

    Скажіть будь ласка як такий інвентор працює на підмішування

    • @Vladyslav_M
      @Vladyslav_M  3 месяца назад +2

      Напруга від сонячних панелей потрапляє на високвольтну шину постійного струму. Далі з цієї напруги нарізається синус 220В і подається на вихід до навантаження. Синус трохи зміщується по фазі відносно синусу мережі і за рахунок цього відбувається підмішування. Датчик струму бачить, щоб генерувати інвертором енергію не більшу ніж потрібно навантаженню - щоб енергія не пішла в мережу, а пішла лише на вихід до навантаження. А ті інвертори які віддають в мережу в них ще вимірюється струм для віддачі в мережу.
      Можете по схемі більш детально ознайомитись. Загальна принципова схема до інвертора 3кВт. drive.google.com/file/d/1KcK8nqVjxBSNNBwuSozRpnlWj-dVI-m1/view?usp=drive_link

  • @user-nd5vn3yf4o
    @user-nd5vn3yf4o 7 месяцев назад

    Доброго дня. Хто стикався із тим що при включенні гібридного deye 6k у домашньому електричному колі у якому знаходиться стабілізатор (9кВт Елекс Ампер) на будинок, то стабілізатор починає видавати якісь посторонні звуки (цокати-тріщати легенько) ? А при відключенні інвертора зразу пропадають ці звуки. Пробував підключати інвертор як після так і перед стабалізатором, все рівно йдуть посторонні звуки.
    Дякую за консультацію.

    • @Vladyslav_M
      @Vladyslav_M  7 месяцев назад +2

      Доброго дня. Так, бачив схожі відгуки.
      Можете спробувати перешити через підтримку.
      Коментар підписника:
      До речі я начитався як всі наярюють на Deye який це найкрутіший Мерседес в світі інверторів і порадив своєму другу купити його. Реальність вийшла не такою й солодкою. Поставив він його замість звичайного клону вольтроніка з яким без проблем пережив минулу зиму. І виявилось що при роботі в байпасі блоки живлення по всій квартирі (від телевізора, моніторів, побутової техніки місцями) почали свистіти/пищати. При роботі від батареї писку немає. Покурив він інтернет і виявляється то не баг а фіча. Дуже багато скарг на писк на частоті 15кГц. Судячи з інфи з форумів проблема частково вирішується перепрошивкою на іншу версію, де в меню є "low noise mode", в якому ця проблемна частота змінюється з 15 на 20кГц, які вже майже ніхто не чує. Але ж Дейє не дає самостійно перепрошивати інвертори, то він пише їм в саппорт щоб дозволили перепрошивку. Сподіваюсь дозволять, а то вийшло що не знаючи підклав другу дорогу свиню.

    • @user-nd5vn3yf4o
      @user-nd5vn3yf4o 7 месяцев назад

      @@Vladyslav_M дякую за відповідь.

    • @maximbezzubenko4150
      @maximbezzubenko4150 2 месяца назад

      Я оце читаю відгуки про згорівші дешеві інвертори, і думаю, може треба брати дорогий, щоб не переплачувати і не мучитись. Наприклад Deye. А тут і за deye цікаві відгуки. Що ж його брати?.. Дякую за цінну інформацію!

  • @darmasiriperera6612
    @darmasiriperera6612 3 месяца назад

    Hi friend helps me to find a powmr 3kv hybrid inverter circuit diagram

    • @Vladyslav_M
      @Vladyslav_M  3 месяца назад

      Hi!
      3kW inverter circuit drive.google.com/file/d/1ABEI3BDl0_Aj2Mo6i8WOiuRvm7qBUTsC/view?usp=drive_link You can thank the author of the scheme using the link - send a donation for coffee
      send.monobank.ua/7ZAsawoo1A
      General schematic diagram for the 3 kW inverter.drive.google.com/file/d/1KcK8nqVjxBSNNBwuSozRpnlWj-dVI-m1/view?usp=drive_link
      General schematic diagram for the 6.2 kW inverter.drive.google.com/file/d/1fP8a9dsouOJyz28EQZN3VFZjukoEzuf9/view?usp=sharing
      Schemes have some inaccuracies, there may be mistakes.

  • @andriysementsov5446
    @andriysementsov5446 Год назад

    Коли вийшов з ладу інвертор, що з сталося із батареєю? Батарея була в к.з. (це ті комірки EVE?)? З боку інвертора, як я зрозумів, ніяких запобіжників на виходах\входах немає?
    Наскільки доцільно було б додатково встановити автоматичні вимикачі на входи\виходи? Чи врятували б вони транзистори від пробою?

    • @Vladyslav_M
      @Vladyslav_M  Год назад +2

      В мене був запобіжник по батареї на 150А. Він згорів але разом з тим і бмс. По входу (по 24В) в інверторі досить великої ємності конденсатори і навіть тої енергії вистачає спалити транзистори без акумулятора, просто від лбж 24в зі струмом 1А. В даному випадку проблема пішла зі сторони мппт. А так по входу і виходу 220в бажано встановлювати швидкі запобіжники. В мене були звичайні + автоматичний вимикач.

    • @andriysementsov5446
      @andriysementsov5446 Год назад

      ​@@Vladyslav_M Проблема зі сторони мррт? тобто, ще треба на вхід від сонячних панелей ставити захист? (по струму чи напрузі?) Я питаю до того, що як би лиха не сталося, коли воно автономно працює, і тут щось іде не за планом (характеристиками інвертора).. Побачивши в цьому відео кз на батареї (і пам'ятаючи відео, як запускали комірки лі-фе-по із цим інвертором), я припустив про найгірші наслідки. А в загалом цікаві відео 👍

    • @volodymyrzakolodyazhny7740
      @volodymyrzakolodyazhny7740 Год назад

      Вимикачі - завжди корисні, бо сильно спрощують збирання, і підвищують зручність, надійність і безпеку роботи.
      Від вигорання електронних компонентів - ніякі автомати чи запобіжники не допоможуть.

    • @Vladyslav_M
      @Vladyslav_M  Год назад +1

      @@andriysementsov5446 в моєму випадку на МППТ була подана напруга без обмеження по струму. МППТ працював нормально навіть без обмеження по струму. Але в момент підмішування енергію напевно почав пропускати завеликий струм і пробило діод і транзистор МППТ. А далі цепна реакція. Заобіжник, або автомат від батареї має бути, хоча б захист від пожежі.

  • @UA-ql9no
    @UA-ql9no 9 месяцев назад

    Добрий день. Купив інвертор POWMR 3.2KW під час тестового підключення випадково пустив зворотню напругу. Чи можете взяти його на ремонт? Сподобався ваш підхід. Роман м.УЖГОРОД. Буду вдячний за відповідь.

    • @Vladyslav_M
      @Vladyslav_M  9 месяцев назад

      Добрий день. Дякую, але не займаюсь ремонтами, краще звернуться до тих хто цим займається профільно.

  • @TSMatvey
    @TSMatvey Месяц назад

    купив ПавМр 3.2 кВт і хотів уже встановлювати плати для вентиляторів як у вашому відео - але він вимкнувся при роботі від акб і не вмикається( знаєте куди в Києві можна здати в хороший ремонт?

    • @Vladyslav_M
      @Vladyslav_M  Месяц назад +1

      Перевірте, може низька напруга на АКБ, або наприклад бмс вимкнула свій вихід.

    • @TSMatvey
      @TSMatvey Месяц назад

      ​​​@@Vladyslav_Mа як перевірити бмс? Бо у мене 2 акуми powerqueen ліфепо, але заводські уже зібрані по 12.8в 100аг, під'єднані паралельно, щоб дати 24в і по ідеї в кожному акумові своя бмс і вони без блютузу

    • @TSMatvey
      @TSMatvey Месяц назад

      @@Vladyslav_M такс, виявилось, що в меню стояв АГМ акум і під нього параметри. виставив згідно вашого відео напруги і ніби поки працює.
      Ще раз дякую за такі детальні та змістовні відео!

  • @romanbuk6180
    @romanbuk6180 3 месяца назад

    Добрий день, можливо хтось стикався з проблемою в інверторі PowMr дисплей світиться але нічого не відображає, чи можна якось відремонтувати або замінити?

    • @romanbuk6180
      @romanbuk6180 3 месяца назад +2

      Вирішив проблему, вимкнув інвертор і відʼєднав АКБ. Ввімкнув і запрацювало 😂

  • @mrJenOk-hq5qo
    @mrJenOk-hq5qo Год назад

    Вітаю!
    Підкажіть чи можна у вас замовити послугу по оптимізації системи охолодження інвертора EASUN 5кВт ?

    • @Vladyslav_M
      @Vladyslav_M  Год назад +1

      Вітаю. Ні, не займаюсь, лише показував як собі модернізував.

  • @kinoxa5119
    @kinoxa5119 2 месяца назад

    Тримає даний інвертор заявлену потужність???

    • @Vladyslav_M
      @Vladyslav_M  2 месяца назад +1

      Так, 3квт тримає. Ось доречі огляд даного інвертора ruclips.net/video/DpaMOBvDPLQ/видео.html

  • @olehnich8966
    @olehnich8966 11 месяцев назад

    Доброго дня. Після підключення нового інвертора викинуло помилку U 1.0 27 006. Не підкажете в чому проблема? дякую.

    • @Vladyslav_M
      @Vladyslav_M  11 месяцев назад

      Доброго дня. Вже бачив про таку помилку, але нажаль поки не знаю, що вона означає

  • @andrygame
    @andrygame 10 месяцев назад

    Доброго дня, в мене інвертор повмр 4,2кв, сталось кз на лінії входу живлення до інвертора (спрацював зубр) і тепер при підключенні батареї вибиває помилку 52, можете підсказати в чому може бути проблема?

    • @Vladyslav_M
      @Vladyslav_M  10 месяцев назад

      Доброго дня. Низька напруга на високовольтній шині в більшості випадків означає, що там коротке замикання. Напевно пробило високовольтні транзистори і вони коротять шину. Потрібно втручання.

  • @user-nikolya302
    @user-nikolya302 Месяц назад

    При выборе транзистора
    В чем разница 220-263?

    • @Vladyslav_M
      @Vladyslav_M  Месяц назад

      Наскільки памятаю 220-для установки на радіатор. А 263 для впаювання на плату, охолодження через плату. Але можу помилятись, краще перевірте в гуглі.

  • @user-cr8tb8yy7e
    @user-cr8tb8yy7e 3 месяца назад

    Доброго вам дня.Якщо можно дайте коментар.Я тестую свій повер емер 6.2 кВт. споживання показує 3.71квт сонячні показано виробляють 2.726 кВт.А в процентному відношенню показує 59 процентів.Яким показникам вірити😮?

    • @Vladyslav_M
      @Vladyslav_M  3 месяца назад +1

      Доброго дня. 59 процентів від 6.2 квт якраз десь і буде 3.71квт (на виході). Наче все правильно. У відсотках відображається значення навантаження на виході.

    • @user-cr8tb8yy7e
      @user-cr8tb8yy7e 3 месяца назад

      @@Vladyslav_M дякую зрозумів 59 від 6.2 кВт я думав що це процент підмішування від мережі

    • @user-cr8tb8yy7e
      @user-cr8tb8yy7e 3 месяца назад

      Добрий день! Повер мр 6.2квт на може в мене запуститись тільки від сонця.мережа відсутня акумулятори теж. пробує стартувати і зразу гасне.Підскажіть будь ласка в чому причина.

  • @dimong2392
    @dimong2392 Месяц назад

    Powmr 5.5кв, згоріли 16транзисторів низкоомні опори і опори біля драйверів, далі все наче ціле. Після заміни всього згорівшого 5.3кв тримає, потім при збільшенні навантаження в захист не йде і знову те саме згорає. Можете підказати чому захист від перевантаження не спрацьовує?

    • @Vladyslav_M
      @Vladyslav_M  Месяц назад

      Неприємна ситуація. Перегріву транзисторів немає? Тепло добре відводиться? І транзистори точно оригінальні? Бо нажаль дуже багато підробок, навіть на китайські транзистори.

    • @dimong2392
      @dimong2392 Месяц назад

      @@Vladyslav_M транзистори 4110(Брав там де люди сказали інші шо вони нормальні і багато їх продано) ті 4 що з ними в парі працють з вигляду і по перевірці наче робочі(осцелографа немаю). Перегріву точно немає повітря холодне. Сьогодні спалив ще одну партію з 16шт, таке наче вони згорають тоді коли але є прилад щітковий: наприклад минулого разу навантажив до 5.3 потім увімкнув пралку мотор тільки рухнувся і все погоріло. Сьогодні було споживання 200ватт увімкнув болгарку на 1кв і BMS на акумі пішов у захист(виключив інвертор) - я перепідлючив клеми і зразу 'бабах'. Але інвертр ніразу не показав помилку 7(перевантаження) він бахає.

    • @Vladyslav_M
      @Vladyslav_M  Месяц назад

      Зрозумів. А де саме купували транзистори? Який магазин, чи посилання, ціна.
      Тепер вже точно треба дивитись осцилографом сигнали на транзисторах, бо там може бути банально проблема в керуючих сигналах і тому вони вилітають.

    • @dimong2392
      @dimong2392 Месяц назад

      @@Vladyslav_M Керуючі сигнали то треба дивитись оптопару чи драйвери? Драйвери цілі були. Маєте ссилку на осцилограф щоб купити?

    • @Vladyslav_M
      @Vladyslav_M  Месяц назад

      Краще дивитись сигнали які приходять саме на транзистори. Але це треба робити дуже обережно. Можна впаяти на кожен канал по одному транзистору і перевірити сигнали осцилографом. Ось недорога моделька осицлографа t.ly/osc
      Для базових задач цілком достатньо.

  • @usermobile7787
    @usermobile7787 9 месяцев назад

    Доброго вечорапідкажіть ви на ремонт інвертори берете pmr 3.2kw 24v?

    • @Vladyslav_M
      @Vladyslav_M  9 месяцев назад

      Доброго вечора. Ні, не займаюсь. Пошукайте, когось ще.

  • @user-vm8hc4sr5n
    @user-vm8hc4sr5n 5 месяцев назад

    Вітаю,хочу запитати,чому інвертор йде у захист,при підключенні його до живлення квартири,а коли заряджається лише моб. телефон ні.Живлення квартири в основному освітлення десь до 400вт,інвертор 500вт?

    • @Vladyslav_M
      @Vladyslav_M  5 месяцев назад

      Вітаю. Під час запуску освітлення може бути велика пускова потужність. Або просто інвертор такої низької якості і не витягує навіть 500вт заявленої потужності.

    • @user-vm8hc4sr5n
      @user-vm8hc4sr5n 5 месяцев назад

      @@Vladyslav_M дякую,але все до цього працювало,тянуло світло,тв.Буду розбиратись.

    • @Vladyslav_M
      @Vladyslav_M  5 месяцев назад

      Тоді подивіться всі контакти всередині, можливо послабли. Особливо від акумулятора до плати. Виміряйте як просідає напруга від акб на самій платі. Часто інвертори приходять з погано затягнутими болтами, гайками. Якщо все добре, знімайте плату і пошукайте погано пропаяні місця.

    • @user-vm8hc4sr5n
      @user-vm8hc4sr5n 5 месяцев назад

      @@Vladyslav_M Дякую.

    • @user-vm8hc4sr5n
      @user-vm8hc4sr5n 5 месяцев назад

      ​@@Vladyslav_M дякую за пораду,почистив контакти та клеми на АКБ та інверторі були окисленні,все працює!

  • @user-filiuk
    @user-filiuk 28 дней назад

    Де можна купити такий прибор ?

    • @Vladyslav_M
      @Vladyslav_M  28 дней назад

      У відео було декілька приладів. Про який саме мова?

  • @user-oo7nw5eo9v
    @user-oo7nw5eo9v 8 месяцев назад

    Доброго дня.
    Потрібна допомога з ремонтом powmr 3.2
    Дайте Ваші контакти.

    • @Vladyslav_M
      @Vladyslav_M  8 месяцев назад

      Доброго дня. Ремонтами не займаюсь. Пошукайте, хто спеціалізується саме на ремонтах.

  • @user-ws6ys4ke6e
    @user-ws6ys4ke6e 4 месяца назад

    Доброго дня,чи можливо відремонтувати такий інвертор як у вас на відео . Як звами можна зв'язатися?

    • @Vladyslav_M
      @Vladyslav_M  4 месяца назад

      Доброго дня. Вибачайте, не займаюсь ремонтами.

  • @mishago25
    @mishago25 Год назад

    Коли відключав автомат ) таке відчуття що очі закривав)))

    • @Vladyslav_M
      @Vladyslav_M  Год назад +1

      І очі і відвертаюся і молюся подумки:)

    • @mishago25
      @mishago25 Год назад

      Доречі купив блок дельта для заряду АКБ щоб інвертор відключити від мережі, думаю схему як зробити щоб по напрузі включався і велике навантаження коли нема сонця

    • @mishago25
      @mishago25 Год назад

      Щоб максимум з сонця знімати, а відео у вас завжди цікаве, дякую .

  • @user-nv7xd8iu9x
    @user-nv7xd8iu9x 11 месяцев назад

    Доброго дня! Прошу допомоги. Купив інвертор Axioma bfp5000,підключив без сонячних ще рік тому все прцює гарно.в цьому році змонтував панелі , а коли почав підключати ,виявилося коротке на вході інвертора, хоча ніяких помилок немає. Може підкажете адекватного майстра , бо схеми немає. дуже дякую. Відео дуже спадобалося , усе зрозуміло.Дякую

    • @Vladyslav_M
      @Vladyslav_M  11 месяцев назад

      Доброго дня. А може то у Вас конденсатори заряджаються? Якщо мова про вхід для АКБ. Схеми якщо потрібні можете завантажити. Схеми в більшості свого думаю схожі.
      Детальна схема інвертора 3кВт drive.google.com/file/d/1ABEI3BDl0_Aj2Mo6i8WOiuRvm7qBUTsC/view?usp=drive_link Пан Василь особисто її змалював з реального інвертора. Подякувати Василю за схему можна за посиланням send.monobank.ua/7ZAsawoo1A Загальна принципова схема до інвертора 3кВт. drive.google.com/file/d/1KcK8nqVjxBSNNBwuSozRpnlWj-dVI-m1/view?usp=drive_link Загальна принципова схема до інвертора 6.2кВт. drive.google.com/file/d/1fP8a9dsouOJyz28EQZN3VFZjukoEzuf9/view?usp=sharing Схеми мають деякі неточності, можуть бути помилки.
      Стосовно майстра нажаль не підкажу. Пошукайте на каналах, які саме займаються ремонтами.

    • @user-nv7xd8iu9x
      @user-nv7xd8iu9x 11 месяцев назад

      Дуже дякую за схеми. У мого інвертора коротке по сонячному входу(PV+ PV-).На схемі пана Василя є деталь HCT1. Що це?@@Vladyslav_M

    • @Vladyslav_M
      @Vladyslav_M  11 месяцев назад

      Hct1 це датчик струму. Якщо кз по сонячному входу значить скоріш за все пробитий силовий транзистор на мппт

  • @user-zh4pg4gc6t
    @user-zh4pg4gc6t 9 месяцев назад

    Ви займаєтеся ремонтом?
    Потрібно відремонтувати інвертор.

    • @Vladyslav_M
      @Vladyslav_M  9 месяцев назад

      Ні, не займаюсь. Лише свої, після невдалих тестувань)

  • @sergeyignatenko6495
    @sergeyignatenko6495 8 месяцев назад

    Доброго дня. Прошу поради. Інвертор 3кВт ПоверМр коли вимикаю кнопкою він вимикається на декілька секунд (повністю вимкнувся) і знову включається і так повторюється знову включиться і виключиться.

    • @Vladyslav_M
      @Vladyslav_M  8 месяцев назад

      Доброго дня. Схоже щось по керуванню. Треба перевіряти кола керування. Це з самого початку використання, чи з часом сталось? Якщо треба можу відправити схему.

    • @sergeyignatenko6495
      @sergeyignatenko6495 8 месяцев назад

      @@Vladyslav_M З самого початку користування. Буду вдячний за схему якщо зручно позначте на схемі коло керування. Дякую.

    • @Vladyslav_M
      @Vladyslav_M  8 месяцев назад

      Напишіть мені на пошту vladislav.adc@gmail.com відправлю схему

  • @lekha777
    @lekha777 Год назад

    Чим цього разу обмежували струм на сон.вході?

    • @Vladyslav_M
      @Vladyslav_M  Год назад +1

      Так само через тен. Лампочка, тен поки інших простих варіантів немає.

  • @berya1966
    @berya1966 11 месяцев назад

    Доброго дня підкажіть будь ласка які кулери замовити на випадок заміни

    • @Vladyslav_M
      @Vladyslav_M  11 месяцев назад +1

      Доброго дня. Такі точно шукав, не знайшов. Треба щоб вентилятори мали достатню продуктивність

    • @orestbasarab3771
      @orestbasarab3771 Месяц назад

      ​@@Vladyslav_Mа яка для них нормальна продуктивність?

  • @GURGEN18
    @GURGEN18 Год назад

    Добрый день. Хочу использовать аналогичный гибрид(6.2 квт) в режиме ИБП(без подключения к горсети. Можно ли заряжать штатный аккумулятор 48 в от внешнего аккумулятора 12 в через повышающий dc-dc. Подключение к солнечным панелям и горсети отсутствует пока

    • @Vladyslav_M
      @Vladyslav_M  Год назад

      Доброго дня. Думаю можна, головне візьміть потужний dc-dc. А чим будете заряджати 12в акумулятор?

    • @GURGEN18
      @GURGEN18 Год назад

      @@Vladyslav_M 12в аккумулятор заряжается от 2-х солнечных панелей по 300вт каждая через свой мппт контролер. С него через повышающий(1.8 квт) dc-dc хочу заряжать ,тот аккумулятор(48в)который подключен к гибридному инвертору. Аккумулятор 12 в lifepo4 -280 ah, 48 в аккумулятор -240 ач тоже лифер

    • @Vladyslav_M
      @Vladyslav_M  Год назад

      @@GURGEN18 зрозумів. Ну в теорії схема робоча. Може не дуже оптимальна через багато перетворень енергії. Але працювати повинно.

  • @user-yk4hm3dw9b
    @user-yk4hm3dw9b Год назад

    Підкажіть будь ласка, як зробити так щоб перетворювач TATALIKEN 4500W не йшов на захист коли стартує холодильник, коли холодильник стартує перетворювач відключається і заново запускається і запускає холодильник, в чому може бути причина? перед цим у мене був такий же, він запускав два таких холодильника,але спіймав зустрічно на вхід 220V.Заздалегідь вдячний за відповідь.

    • @Vladyslav_M
      @Vladyslav_M  Год назад

      Навіть не знаю, бо якщо з акумулятором все добре, то інвертор мав би тягнути запуск холодильника. Або може продавець приклеїв неправильну наклейку на інвертор? Для запуску потрібно хоча б інвертор з номінальною потужністю 1000Вт. Перевірте скільки він реально тягне, яку потужність.

    • @user-yk4hm3dw9b
      @user-yk4hm3dw9b Год назад

      @@Vladyslav_M Мікрохвильовку з потужністью 1100ват тягне,фен 1600ват тягне,але дуже просажує аккумулятори,а от старт у нього слабий,хоча такий же попередній добре працював.

    • @Vladyslav_M
      @Vladyslav_M  Год назад

      @@user-yk4hm3dw9b ну тоді дійсно дивно, мав би запускати холодильник. Щось з ним не добре.

    • @PitOdessa
      @PitOdessa 11 месяцев назад

      Пусковые токи асинхронного двигателя при запуске холодильника достигают десятки ампер ( до 40 Ампер) в зависимости от мощности двигателя. Поэтому любой инвертор будет нагружаться. Бросок тока происходит в первую волну 20 мс. Выход: ограничение тока резистором в пару десятков Ом где-то 40 мс по времени, а дальше шунт резистора с помощью реле. Я собрал схему и вышло 2 твердотельных реле плюс реле задержки и резистор.

  • @-GreyWolf-
    @-GreyWolf- Год назад

    Підкажіть, з точки зору надійності, який інвертор краще на 12 чи 24 Вольта?
    Навантажуватись буде на 20-30 % від потужності.

    • @D9ID9I
      @D9ID9I Год назад

      Чим вища напруга, тім краще. Бо тупо струм меньший.

    • @Vladyslav_M
      @Vladyslav_M  Год назад

      Якщо брати 12в і 24в повмр 1.5 і 3квт. То охолодження у них ідентичне. А значить 12в буде нагріватись значно менше. Але у 12в інвертора струми будуть більші при однаковій потужності

    • @klotoslive5707
      @klotoslive5707 Год назад +1

      @@Vladyslav_M Навпаки, при однаковій потужності струм (ампераж) менший там, де більша напруга (вольтаж), адже P = I * U. Тобто при однаковій потужності в 1кВт у 12В інверторі струм буде 1000Вт / 12В = 83А, а у 24В інверторі струм буде 1000Вт / 22В = 41А.

    • @user-nt3yn7oc1r
      @user-nt3yn7oc1r Год назад

      ​@@Vladyslav_Mобмовились, при 12В струми будуть більші

    • @Vladyslav_M
      @Vladyslav_M  Год назад

      Так, обмовився. Їхав за кермом в пробці і відповідав). То ж думаю вже майже всім відомо, що при 12в більші струми.

  • @user-cr8tb8yy7e
    @user-cr8tb8yy7e 3 месяца назад

    Скажіть будь ласка повер мр 6.2 квт можно експлуатувати без акамулятора .Тільки сонце та мережа.

    • @Vladyslav_M
      @Vladyslav_M  3 месяца назад +1

      Так, можна. Підмішувати також вміє без акб. Сонячну енкргію до енергії мережі.

    • @user-cr8tb8yy7e
      @user-cr8tb8yy7e 3 месяца назад

      @@Vladyslav_M Дякую. В налаштуваннях повер Мр 6.2 дуже багато пунктів по акамулятору.Як налаштувати його для роботи без акумулятора.

    • @Vladyslav_M
      @Vladyslav_M  3 месяца назад +1

      Режим SUB а все інше думаю не принципово.

    • @user-cr8tb8yy7e
      @user-cr8tb8yy7e 3 месяца назад

      @@Vladyslav_M На життєвий ресурс інвертора робота без акумулятора на відзначиться?

    • @Vladyslav_M
      @Vladyslav_M  3 месяца назад +1

      Без акумулятора йому легше живеться, немає великих робочих струмів на заряд і розряд. Без акумулятора точно буде жити довше :)

  • @dorofieiev-dys
    @dorofieiev-dys 2 месяца назад

    Вот бы вы схему ещё выложили!?

    • @Vladyslav_M
      @Vladyslav_M  2 месяца назад

      Детальна схема інвертора 3кВт drive.google.com/file/d/1ABEI3BDl0_Aj2Mo6i8WOiuRvm7qBUTsC/view?usp=drive_link Пан Василь особисто її змалював з реального інвертора. Подякувати Василю за схему можна за посиланням send.monobank.ua/7ZAsawoo1A
      Загальна принципова схема до інвертора 3кВт. drive.google.com/file/d/1KcK8nqVjxBSNNBwuSozRpnlWj-dVI-m1/view?usp=drive_link
      Загальна принципова схема до інвертора 6.2кВт. drive.google.com/file/d/1fP8a9dsouOJyz28EQZN3VFZjukoEzuf9/view?usp=sharing Схеми мають деякі неточності, можуть бути помилки.

  • @andriysementsov5446
    @andriysementsov5446 11 месяцев назад

    Доброго дня!
    Підкажіть, будь-ласка, приїхав інвертор (Anern ECO-3200), по дісплею і роз'ємам виглядає як і Powmr;
    Ще не вмикаючи, виявив, що на клемах для підключення батареї тестер показує к.з. між + і -, чи є це нормально?

    • @Vladyslav_M
      @Vladyslav_M  11 месяцев назад +1

      Міряйте не просто на пищалку, а краще на продзвонку діодів і побачите що спадання напруги по троху змінюється - проходить заряд вбудованих конденсаторів. Значить все добре. Довго на коротко не має дзвонитись

    • @andriysementsov5446
      @andriysementsov5446 11 месяцев назад

      @@Vladyslav_M
      На жаль у мене тільки пищалка UT18C((
      Подивився на схему Вашого інвертора, між клемами підключення батареї наче є електричне коло, яке йде через котушку трансформатора.
      Виглядає наче електричний зв'язок має бути.
      Дякую!🙏

    • @Vladyslav_M
      @Vladyslav_M  11 месяцев назад

      Пищалка має перестати пищати секунд через 10-40. Почекайте. Там зв'язок є через трансформатор, але то не КЗ має бути

    • @andriysementsov5446
      @andriysementsov5446 11 месяцев назад

      @@Vladyslav_M
      Як виявилось, пищалка пищить не припиняючись (3-4 хв точно, далі не чекав);
      В моїй ситуації є панелі, є інвертор, але немає батареї. Без батареї, інвертор ніяк не реагує на перемикач при підключених 220В та PV. Знайшов старенький латр (0-30В), щоб зімітувати батарею. Так при першому включені латру, у нього спрацював захист від кз. При другому запуску, і далі при тестах, захист по кз не спрацьовував.
      Це я до того, що батарею однозначно треба підключати через захист.
      Також помітив, коли інвертор вимкнено, але підключені панелі, і батарея; то інвертор намагається заряджати батарею через PV вхід.

    • @Vladyslav_M
      @Vladyslav_M  11 месяцев назад +1

      @@andriysementsov5446 батарею бажано включати спочатку через передзаряд (наприклад, послідовно за лампою накалювання). Не знаю чтому у Вас пищалка не перестала пищати, мала би після заряду конденсаторів перестати.
      Інвертор 3квт не вміє праюцвати без акумулятора, і бажано його навіть не пробувати запускати без акумулятора.
      Інвертор включається навіть з відключеною кнопкою, коли йде заряд від мережі, або панелей, це штатна робота.

  • @oyoy8517
    @oyoy8517 Месяц назад

    "Схемка допомагає"... а чому ж не поділились схемкою, Вам же дали.... дякуючи Василю.... за те повно посилань ....?

    • @Vladyslav_M
      @Vladyslav_M  Месяц назад

      Полистайте трохи коментарі і все знайдете.