FIRE ALARM || CONVENTIONAL FIRE ALARM PANEL || TYY CONVENTIONAL PANEL ||

Поделиться
HTML-код
  • Опубликовано: 21 авг 2024
  • Lazada: bit.ly/3P9kwxN
    Everything about Conventional Fire Alarm Panel well be discuss in this video.
    If you are a beginners or want to know more, especially how the systems work, then this is for you.
    Topics:
    1. How the conventional Fire Alarm Panel Works.
    2. What is the purpose of End Of Line (EOL) Resistor.
    3. What is the correct termination of Manual Call Point (MCP) and BELL.
    If you learn something in this video, Please do Like and Subscribe to this channel for more FDAS knowledge. \\
    If we can reach 1000 subscriber, I will cover how the COOPER, GST and Morley-iAS Systems work.
    From Termination, design and programming.
    With programming software.
    Thank you!!!!
    PANEL:
    www.lazada.com...
    / safetytechnician

Комментарии • 111

  • @MarckAncajasMA
    @MarckAncajasMA 2 месяца назад

    COMPLETELY WRONG. IT IS NOT CURRENT SENSING. YOU SHOULD CHECK THE CIRCUIT FIRST.

    • @whatever.TV88
      @whatever.TV88  2 месяца назад

      Thank you. ikaw na check mo na?

    • @MarckAncajasMA
      @MarckAncajasMA 2 месяца назад

      @@whatever.TV88 yes wrong

    • @MarckAncajasMA
      @MarckAncajasMA 2 месяца назад

      @@whatever.TV88 if you can tell me the IC number then i will tell you you are wrong.

    • @whatever.TV88
      @whatever.TV88  2 месяца назад

      @@MarckAncajasMA Paano pala Master para ma correct ko.

    • @MarckAncajasMA
      @MarckAncajasMA 2 месяца назад

      @@whatever.TV88 i know what im talking about. all IDC circuit for conventional FACP is not current sensing. The EOL resistor is designed to comply for NFPA72 requirements to have a surpervised curcuit that monitors short circuit, open circuit and Alarm status but the circuit is not designed with current sensing. the answer is can be known thru ic number of IDC. i have been working IDC design. so i know im right.

  • @fredroble4830
    @fredroble4830 2 года назад +1

    Salamat sir

  • @meldiskarte7561
    @meldiskarte7561 Год назад

    Salamat idol alam Kona

  • @alexandercellon971
    @alexandercellon971 2 года назад +1

    Cooper na man sir☺️☺️

    • @whatever.TV88
      @whatever.TV88  2 года назад

      pagmakahiram tayo panel Sir. hehehe. Wala na kace tayo ngayun sa Cooper.

  • @alexandercellon971
    @alexandercellon971 Год назад +2

    Master ok SA isang zone dalawang manual call point na tyy. 4wires. Po. Yng wiring. Sa terminal. Niya isang zonel pwd paanu po I termination po. Slmt master

    • @whatever.TV88
      @whatever.TV88  Год назад

      2 wires lang kay TYY Master, naka patallel ang termination., kung ibang brand e install mo pwede naman peru kung dry contact type na MCP yan need mo ng trigger resistor kace shorted po lalabas nyan.

  • @renaldtejada8497
    @renaldtejada8497 28 дней назад

    master halimbawa umabot device mo ng 40 isang zone isang 10k ohms pa rin ilalagay?

    • @whatever.TV88
      @whatever.TV88  28 дней назад

      sa specs master up to 30 device lang. baka magkaka fault na yan. di ako sure.

  • @joeydegamo8727
    @joeydegamo8727 2 года назад +1

    Bos pag dalawang panel pwd ba e synchronised ang Bell to bell anong gamit na ma synchronised sya?

    • @whatever.TV88
      @whatever.TV88  2 года назад

      Dito sa panel natin Master conventional to kaya need mag add ng relay. bali double input single output and relay na e design

  • @user-rd9oc2vv2y
    @user-rd9oc2vv2y 2 месяца назад

    Sir may EOL resistor po ba sa sounder natin?

  • @markangeloimporta1614
    @markangeloimporta1614 Год назад

    4:25 principle of operation ng conventional fire detection alarm system/paano gumagana ang fdas

    • @whatever.TV88
      @whatever.TV88  Год назад +1

      Current driven yan. wala pong data na binabato nya. nag depende yan sa current na dumadaloy sa Zones.

    • @markangeloimporta1614
      @markangeloimporta1614 Год назад

      @@whatever.TV88 saan ko po siya sir pwede pag-aralan, may link ka po ba sir na tungkol sa conventional fdas?

    • @whatever.TV88
      @whatever.TV88  Год назад

      @@markangeloimporta1614 Based on my experience and curiosity lang lahat yan Master. Kung gusto mo matoto nyan lahat pwede ka mag apply sakin 1on1 training. Paid po yun xiampre peru sabi ko sayo a decade of experience ang makukuha mo sa akin. pm ka lang.

  • @jonahguitarchannel3504
    @jonahguitarchannel3504 7 месяцев назад

    Hello.idol ask ko lang if may natirang bakante pang zone or sounder need bang lagyan ng resistor un ?

    • @whatever.TV88
      @whatever.TV88  6 месяцев назад +1

      Yes po. Dapat andjan palage ang EOL Resistor

  • @user-rd9oc2vv2y
    @user-rd9oc2vv2y 2 месяца назад

    Sir ask ko lang po paano po kung Yung connection na galing sa panel board ay line to line connection papaano po ito e connect sa facp ?

    • @whatever.TV88
      @whatever.TV88  2 месяца назад

      Di ko ma gets ano ibig mong sabihin sa line to line Master. pa explain ng maayos

    • @user-rd9oc2vv2y
      @user-rd9oc2vv2y 2 месяца назад

      @@whatever.TV88 diba Meron line to ground connection Meron din line to line connection na kadalasan sa urban area..or single phase three wires po..ang tanung ko po sana po masagot ninyu Yung connection po sa panel board ng fire alarm(facp) paano po e connect ang linya na parehong may 110 volts each?

    • @whatever.TV88
      @whatever.TV88  2 месяца назад

      @@user-rd9oc2vv2y ahh okay. sa power source pala tinutokoy mo.
      tatlo po terminal nyan parihu lang yan sa ibang mga appliances mayron Hot Neutral Ground.

  • @ivancruda9445
    @ivancruda9445 2 года назад

    Sir, ganda po ng pagka turo niyo po,
    tanung ko lng paano po pag mag iinstall po ako ng 3pcs Alarm Bell 10" at 8pcs na 6" na Alarm Bell, at nabanggit niyo po upto 4 pcs Alarm Bell lng kaya ng Panel.
    Ano po pwed gawin?

    • @whatever.TV88
      @whatever.TV88  2 года назад +1

      Salamat idol.
      Para makapag install ka ng mas maraming output devices like Bell and Strobe light, need mo ng separate supply para sa kanila. tapus gumamit ka ng relay (SPDT) type na 24V with Diode dapat. marami sa electronics store yan. kung di mo kabisado ang connection at termination, message ka sakin.

    • @franconap2871
      @franconap2871 Год назад

      @@whatever.TV88 sir magandang araw po pwede din po ba ako magpatulong hihingi din po kase sana nang guide para sa connection at termination para makapag kabit po nang maraming sounder sir

    • @whatever.TV88
      @whatever.TV88  Год назад

      @@franconap2871 Dali lang yan Master. need mo lang ng extra power supply na may back up battery din dapat kace kung walang back up battery bagsak po yan sa standard.

  • @alexandercellon971
    @alexandercellon971 Год назад

    4 zone panel po ba Ilan. Kaya sounder or horn strobe Kaya po ba 6pcs bell or strobe slmt master

  • @jhebscubico1990
    @jhebscubico1990 3 месяца назад

    sir paano kng magtrigger ang MCP at hindi nag alarm ang FACP. ano po problema kapag ganon?

  • @rodforiogabutero4117
    @rodforiogabutero4117 2 года назад

    Boss paano ikabit qng smoke detector fire guard yong bracket niya 1234 09-35v. Tapos gamit ko 24 v. Na conventional panel TYY salamat

    • @whatever.TV88
      @whatever.TV88  2 года назад

      Check mo muna bai kung pwede ba e two wires ang installation sa emu fireguard. wala pa naku na try

  • @arvievaldez977
    @arvievaldez977 2 года назад

    Lods di pa po aq naka ranas ng ganyan kaya nanunood aq

  • @paopawliba6740
    @paopawliba6740 Год назад

    Same lang po ba sila ng brand na arrow sir.??

  • @francisgustilo2015
    @francisgustilo2015 2 года назад

    hi boss, pwede ko kayo kunin for company in-house training and project installation?

    • @francisgustilo2015
      @francisgustilo2015 2 года назад

      maganda po pagkaturo nyo lalo sa mga beginner katulad ko

    • @whatever.TV88
      @whatever.TV88  2 года назад

      Pweding pwede Sir. contact mo lang ako. 09566756808

  • @tatajungay2790
    @tatajungay2790 Год назад

    Series ba yan ang resistor sa mps master

    • @whatever.TV88
      @whatever.TV88  Год назад

      Pag TYY MCP gamit mo no need na ang Resistor Master

  • @rodeleenmontehermoso7680
    @rodeleenmontehermoso7680 10 месяцев назад

    Anu ang problema kapag nag test ng sd tapos umilaw hindi naman nag trigger ung strobe anu po problema.,

    • @whatever.TV88
      @whatever.TV88  10 месяцев назад

      Same brand ba ang Detector at ang Control Panel?

  • @tatajungay2790
    @tatajungay2790 Год назад

    Same p yan panel sa assesment namin bakit ayaw gumana s1 isang bel at z1 isang detector at mps.. At may resistor naka series sa bell at meron din ressitor sa una bakit ayaw pumalo ang bell try ko pinalo ung mps nag alarm cignal. Lang ung panel. Bakit hindi tumotunog

    • @whatever.TV88
      @whatever.TV88  Год назад

      Diode dapat nakalagay sa Bell. may polarity yun

    • @whatever.TV88
      @whatever.TV88  Год назад

      kahit walang resistor ang zones pwede yun. may option ka djan na di gamitin ang EOL master. kung marami pa kayong di natutunan. punta kayo sa office. budget meal lang ang bayad.

  • @eddavebongcawel4615
    @eddavebongcawel4615 2 года назад

    Bossing para San po Yung non-laching na push button sa TYY control panel ..

    • @whatever.TV88
      @whatever.TV88  2 года назад

      Saan banda nakalagay ang button master?

  • @meldiskarte7561
    @meldiskarte7561 Год назад

    Sir good day ayaw man mag bato Ng signal yong smoke at sa Ka push button,bkit sir? Anong gawin

  • @rjlcircuitdiagramsystem489
    @rjlcircuitdiagramsystem489 2 года назад

    Nagtetraining po ba kayo ng actual sir?

    • @whatever.TV88
      @whatever.TV88  2 года назад

      sa ngayun wala pa Sir. may inaayus lang ako para magka TESDA tayo. sayang kace

  • @MrJeonard1985
    @MrJeonard1985 11 месяцев назад

    boss panel zone 1, 2, 3, 4, 5 direct with resistor lang 1k walang nakakabit na SD, nagaalarm sya na fire. then yung ibang zone 6, 8,9, 10,11, 12 with resistor normal. ano kaya problema?

    • @whatever.TV88
      @whatever.TV88  11 месяцев назад

      Sir. Trigger resistor po ang 1k. hindi sya EOL. Dapat po 10k ang nilalagay mo.

    • @MrJeonard1985
      @MrJeonard1985 11 месяцев назад

      @@whatever.TV88 kung 10k ko kasi nilalagay katulad resistor ni sounder ng aalarm sya ng OC.. kung 1k normal po sya sa ibang zone.. iba naman fire

    • @MrJeonard1985
      @MrJeonard1985 11 месяцев назад

      Posible ba defective na ang terminal?

    • @whatever.TV88
      @whatever.TV88  11 месяцев назад

      Not Sure. bihira lang naman masira terminal. try mo recta sa terminal ang 10k kung mag okay.
      @@MrJeonard1985

    • @whatever.TV88
      @whatever.TV88  11 месяцев назад

      Ano brand panel mo Sir?
      @@MrJeonard1985

  • @sellihca32moriez22
    @sellihca32moriez22 2 года назад

    Sir sa bell namo Kay wala butangi...pwede BA sya madamge Ang bell.

    • @whatever.TV88
      @whatever.TV88  2 года назад

      coil kace ang bell kaya need mo ng diode para ma direct and current. may posibility na ang masira ay ang output ng panel.

  • @bikolexpress2794
    @bikolexpress2794 Год назад

    Location nyo master.pwede ba magtraining syo

    • @whatever.TV88
      @whatever.TV88  Год назад

      Quezon City Master malapit lang sa Aguinaldo.

  • @meldiskarte7561
    @meldiskarte7561 Год назад

    Bosh paano mag wiring sa bell at saka manual call point

    • @whatever.TV88
      @whatever.TV88  Год назад

      Si bell Idol may sariling terminal yan sa panel yun ang output terminal. c MCP naman pwede na yan sabay sa mga SD.

  • @alexandercellon971
    @alexandercellon971 Год назад

    Good day master capacity Ng isang zone Ilan divice po pwd.

    • @whatever.TV88
      @whatever.TV88  Год назад

      30 mximum sa TYY 4 BELLS per output

    • @alexandercellon971
      @alexandercellon971 Год назад

      Bali sir Kada zone Ng bell apat ang Kaya gnun po ba Yun slmt master

    • @alexandercellon971
      @alexandercellon971 Год назад

      Bali 8 Kaya na bell sa Tyy na 4zone panel sir Yun po ba Yun slmt

    • @whatever.TV88
      @whatever.TV88  Год назад

      @@alexandercellon971 bali may 4 zones ang panel na to maximum of 30 detectors per zone. at may 2 output lang sya na kay ayun sa manual 4 bells per output

  • @jeffvales9962
    @jeffvales9962 2 года назад

    anong specs ng diode master sa bell?

  • @paanovlog3296
    @paanovlog3296 Год назад

    Magkano po yan sir facp?

  • @jedagudo6127
    @jedagudo6127 Год назад

    Sounder open sir khit tama connection

    • @whatever.TV88
      @whatever.TV88  Год назад

      Check End Of Line Resistor. ilang sounder na ba naka connect?

    • @leonimarcaquilala3381
      @leonimarcaquilala3381 10 месяцев назад

      Sir patulong Naman po, bakit naka open circuit parin kahit nagpalit na ko nang mga resistor.. Wala po akong smoke detector at heat detector, bell lang at mcp

    • @leonimarcaquilala3381
      @leonimarcaquilala3381 10 месяцев назад

      ​@@whatever.TV881zone lang po Ang control panel ko

    • @whatever.TV88
      @whatever.TV88  10 месяцев назад +1

      Try mo muna lagay ang mga resistor direct sa Zone terminal na walang load.@@leonimarcaquilala3381

    • @leonimarcaquilala3381
      @leonimarcaquilala3381 10 месяцев назад

      @@whatever.TV88 maraming salamat po, try ko po bukas

  • @user-is4qk8id9k
    @user-is4qk8id9k Год назад

    Sir bakit Hindi Humana Ang manual pull swicth

    • @whatever.TV88
      @whatever.TV88  Год назад

      Anong MCP gamit mo Master? panoorin mo ulit paano mag install ng MCP.

  • @chitotorculas5892
    @chitotorculas5892 2 года назад

    Ser bakit ang tyy mag ka troble kapag madame ang bell

    • @whatever.TV88
      @whatever.TV88  2 года назад +1

      4 bell lang ata nakalagay sa specs ng panel

  • @kokseahteo1716
    @kokseahteo1716 10 месяцев назад

    So LAZY! NO ENGLISH SUB TITLES!!!!!!!

    • @whatever.TV88
      @whatever.TV88  10 месяцев назад

      Sorry na Pre. di maalam magbutang sub.

  • @marvinsotero8385
    @marvinsotero8385 2 года назад +1

    hindi claro ung pagtorumo brand mahina