  • @hieuac9109
    @hieuac9109 3 года назад

    Our pump has a blinking orange led and refuses to connect to computer through serial port. What would cause this?

  • @realdamageboy
    @realdamageboy 2 года назад

    how to remove motor stator correctly to be able to change back seal ?

    • @GG_Dreamcast
      @GG_Dreamcast 2 года назад +1

      I need this same info. Did you ever figure it out? Thanks!

    • @realdamageboy
      @realdamageboy 2 года назад +1

      @@GG_Dreamcast Hi, Yes, I got reply from manufacturer. You must unscrew hex screw inside shaft from motor end, then carefully remove spindle from motor rotor magnet, if You brake magnet, the motor will go in smoke, after removing magnet, there must be smaller shim that hold other side of motor rotor. remember, hammer is not the option, I already tried apply cold spray, but it did not help, now I must try heating the spindle, but right now I do not have time for that. I also notice significant wear on compressor end of shaft that might leak even with new gasket, maybe my pump will go for repair on factory. but please film when You try remove it!