Thanks madam. Good illustration for f/m ratio. Pl up load the complete design of STP . You may take medium cap. STP Plant. May ranging 10 to30 mld plant
Mr. Lal , we suggest that you must first check reason for NIL D.O. , If all diffusers are working fine itmay be the reason that Oxygen supply is unable to meet the BOD / COD demand , you can mae use of OXYSUPER to Increase the D.O. Thanks Team Superweld www.superweld.in
1. HIGH RATE (MODIFIED AERATION) - High F/M ratio (0.4 to 1.5). 2. CONVENTIONAL - Moderate F/M ratio (0.2 to 0.4). 3. EXTENDED AERATION - Low F/M ratio (0.05 to 0.15).
@@saveearth5850 For more ETP related information, subscribe to our channel and press the bell icon to get new video updates. Channel link - ruclips.net/channel/UCKN1lneJD38Br43P8jErgvw
@@saveearth5850 1. In addition to an adequate carbon source, activated sludge bacteria require adequate amounts of nutrients, such as nitrogen and phosphorus, to function properly. 2. The general rule of thumb is that the ratio of BOD-to-nitrogen-to-phosphorus in the primary clarifier effluent be approximately 100:5:1. Nutrient Demand Calculation Nitrogen Demand : 0.04 - 0.05 kg N/kg BOD5. Phosphor Demand : 0.01 - 0.02 kg P/kg BOD5. Example: Waste water inflow = 1000 m3/day Concentration and Load of BOD5 = 1700 mg/L and 1700 kg BOD5/day Nitrogen Demand = 0.05 kg/kg BOD5 Phosphor Demand = 0.02 kg/kg BOD5 Nutrients (N and P) needed for growth of micro-organisms : Nitrogen = Demand × Load = (0.05) kg N/kg BOD5 × (1700) kg BOD5/day = 85 kg N/day. Phosphor = Demand × Load = (0.02) kg P/kg BOD5 × (1700) kg BOD5/day = 34 kg P/day. If the inflow has : (1) total N concentration = 50 mg/L, this means nitrogen load = 50 kg N/day. (2) total P concentration = 10 mg/L, this means phosphor load = 10 kg P/day. Then there are insufficient nutrients in the wastewater. These have to be either be added or the method of treatment has to be reconsidered.
100 M3/d ka flow hai, or 100 mg/lt ki BOD ya COD hai BOD: 100 mg/l ya gm/m3 ya kg/(1000)M3 Q ya flow : 100 M3/d BOD loading: 100 M3/d X 1kg/1000 M3 =0.1 kg/d kyoki M3 se M3 cut jayega or kg/d bach jayega....
Menu mam is excellent described everything and outstanding knowledge regarding waste water.thanks mam.yes Sunil Singh ji.ph is not called growth it is say that as per technically pH increasing and raising.ok.first you have checked raw effluent alkalinity and pH range the pH range goes down due to presence of organic acid carboxylic group.in the effluent if lime and caustic base are added in raw effluent then pH range will be increased.it is very important to maintain for the biological oxidant tank.otherwise microorganisms will not be able to consume the organic matter from waste water thanks
The overflow water in the secondary tank of the biological ETP looks extremely black and dirty. Moreover, the microorganisms in the aeration tank are declining. What is the reason for this?
MLSS ka matlab hai mixed liquor suspended solid, ya jise samanya bhasa me kahe to paani me tairta hua kachra or microorganisms ka mixture. Ye kachra organic material(BOD etc) ka hota hai jise microorganisms kha sakte hai(decompose), Aapke questions ke anusaar, MLSS chala jayega to paani me kuch nahi rahega, Aap ab bataye ki aapke paani me microorganisms kam ho rahe hai ya organic material?
Super dupper and easy way explanation .thanking you
You are very adorable to everyone for described briefly everything with deep knowledge regarding waste water technology
Excellent presentation, every think you have dedcribed clearly.
Thank you so much for such fantastic explanation
Thanks madam. Good illustration for f/m ratio. Pl up load the complete design of STP . You may take medium cap. STP Plant. May ranging 10 to30 mld plant
After watching this video my problem has solved thanks.
Your comment means me alot. This is what my purpose of making videos and sharing my experience.
Thanks for providing very informative and useful matters on STP.
Thank You So Much Mam, for posting this.
Very informative.
Very comprehensive information providing video.
Good method of communication
Thanks for posting a very informative and useful video
Very nice
Nice wrk mam..👌👌
Super mam
Excellent presentation. Everything described clearly
Excellent way of make it understand the processes.
Good knowledge
Very nice ,
Very nice....
Nice
Very important video
Thanks
Thanks mam
Very informative.
Thankyou
Hello Madam...I wanted to learn on designing of Effluent treatment plant..RO Plant and sewage treatment...please advise how can you guide me...
Mam please make a video on Relationship between COD and TOC in waste water treatment
Is there a video to design an ETP,activated sludge based, for Industrial waste water,which needs BOD & COD reduction
Pl take topic on sewage Network design
Superb
Nice information
Sewage treatment plant ka koi government license ya registration hota hai kya????
Reply me please
Mam koi book btaye jo effluent treatment k liye knowledgeable ho
Good hai
Biological main proper air nahi chale to kya problem ho sakta hai please comment 🙏🙏🙏🙏🙏
Mam please will do nutrients dosing calculation for aeration tank and uasbr reactor s🙏🙏🙏
thank you
Mam please help to share some good process to reduce total cyanide and phenol in 110 M3 design flow biological effluent treatment plant.
subscribed
Mam humare aeration tank me foming and d.o nil ho gyi to es condition me kya krna hoga plese reply kijye
Mr. Lal , we suggest that you must first check reason for NIL D.O. , If all diffusers are working fine itmay be the reason that Oxygen supply is unable to meet the BOD / COD demand , you can mae use of OXYSUPER to Increase the D.O.
Thanks
Team Superweld
www.superweld.in
Madem could you make videos in English
👍
Add link of English video mam
👍👍👍👍
It takes 3 - 5 days for BOD result, how can i set FM ratio for present day if I will get BOD result after 5 days..
You can guess by cod of present day
Jo burn ho k fly ho gya
Wo kya h...?
Organic material ya inorganic matter
Organic material
Mam hamare aeration tank ka ph 8.8 ho gaya hai to 7.5 tak kam kaise kare please help me mam
Mam STP plant ki koi book ha kya apki
Madam STP me kon kon se bacteria hote he please reply me
STP ke bacteria ke upper jald hi ek video banaungi....
My MLSS is 1660 ppm and MLVSS is 300 so how i calculate my FM ratio.
Inlet flow=1000m3/day
BOD =470 mg/l
Tank volume = 2480 m3
F/M=1000×470/2480x300=0.63
Wrong estimate
ice cream industry me kam karata hu final water black shade aata hain use clean kaise kare
Lenth 65500mm w 24200mm h 7000mm kitna mld honga ji
Can you put English subtitles please, since the title is also in English?
Ma'am kindly let me know, What should be the F: M ratio?
1. HIGH RATE (MODIFIED AERATION) - High F/M ratio (0.4 to 1.5).
2. CONVENTIONAL - Moderate F/M ratio (0.2 to 0.4).
3. EXTENDED AERATION - Low F/M ratio (0.05 to 0.15).
@@industrialwastewatertreatm7519 thanks bro
@@saveearth5850 For more ETP related information, subscribe to our channel and press the bell icon to get new video updates.
Channel link - ruclips.net/channel/UCKN1lneJD38Br43P8jErgvw
@@industrialwastewatertreatm7519 I subscribed thanks ji
Kindly let me know why/when/How does we use DAP and Urea in aeration tank(biological)???
@@saveearth5850 1. In addition to an adequate carbon source, activated sludge bacteria require adequate amounts of
nutrients, such as nitrogen and phosphorus, to function properly.
2. The general rule of thumb is that the ratio of BOD-to-nitrogen-to-phosphorus in the primary clarifier effluent be approximately 100:5:1.
Nutrient Demand Calculation
Nitrogen Demand : 0.04 - 0.05 kg N/kg BOD5.
Phosphor Demand : 0.01 - 0.02 kg P/kg BOD5.
Example:
Waste water inflow = 1000 m3/day
Concentration and Load of BOD5 = 1700 mg/L and 1700 kg BOD5/day
Nitrogen Demand = 0.05 kg/kg BOD5
Phosphor Demand = 0.02 kg/kg BOD5
Nutrients (N and P) needed for growth of micro-organisms :
Nitrogen = Demand × Load = (0.05) kg N/kg BOD5 × (1700) kg BOD5/day = 85 kg N/day.
Phosphor = Demand × Load = (0.02) kg P/kg BOD5 × (1700) kg BOD5/day = 34 kg P/day.
If the inflow has : (1) total N concentration = 50 mg/L, this means nitrogen load = 50 kg N/day.
(2) total P concentration = 10 mg/L, this means phosphor load = 10 kg P/day.
Then there are insufficient nutrients in the wastewater. These have to be either be added or the method of treatment has to be reconsidered.
Muje etp k bary me maloomat cahea shoru se Kia kohi muje samja Shakta a
Mlvss ka kitna and kaise, kisme sample dena hota hai
Aap mlss ka 1 liter sample lab test me de vo aapko calculate kr k bata dege.
COD And BOD kaise mg/l to kg/d nikale?Please reply
Flow rate bhi lagega calculation me.
@@MeenuJainLalitpur 1 example dijiye na ma'am..
100 M3/d ka flow hai, or 100 mg/lt ki BOD ya COD hai
BOD: 100 mg/l ya gm/m3 ya
kg/(1000)M3
Q ya flow : 100 M3/d
BOD loading:
100 M3/d X 1kg/1000 M3 =0.1 kg/d
kyoki M3 se M3 cut jayega or kg/d bach jayega....
Ma'am mjhe aapse classes leni hai
Calculations dosing
pH kaise growth kare
Menu mam is excellent described everything and outstanding knowledge regarding waste water.thanks mam.yes Sunil Singh ji.ph is not called growth it is say that as per technically pH increasing and raising.ok.first you have checked raw effluent alkalinity and pH range the pH range goes down due to presence of organic acid carboxylic group.in the effluent if lime and caustic base are added in raw effluent then pH range will be increased.it is very important to maintain for the biological oxidant tank.otherwise microorganisms will not be able to consume the organic matter from waste water thanks
Madam need etp related pdf
The overflow water in the secondary tank of the biological ETP looks extremely black and dirty. Moreover, the microorganisms in the aeration tank are declining. What is the reason for this?
over food in the tank
or over dosing of the precipitating agent
or aeration not in proper amount
Aretion me bacteria kaise badaye??
Use dry sludge or collect from other stp plant
Madam i want to design waste water treatment plant for my studies can help me. I send email you my documents can help
Pls hlp me mam
Aap apne questions batao, mai har question ka reply karne ki koshish karungi...
@@MeenuJainLalitpur mam STP plant ma mlss aga chli jati ha tritead water tank ma kya karn ho skta ha
MLSS ka matlab hai mixed liquor suspended solid, ya jise samanya bhasa me kahe to paani me tairta hua kachra or microorganisms ka mixture. Ye kachra organic material(BOD etc) ka hota hai jise microorganisms kha sakte hai(decompose),
Aapke questions ke anusaar, MLSS chala jayega to paani me kuch nahi rahega,
Aap ab bataye ki aapke paani me microorganisms kam ho rahe hai ya organic material?
@@MeenuJainLalitpur microorganisms kam ho rha ha g
Not good teacher,only reading like child
Are you checking the content or my teaching? Even if it's childish I would be happy if you learn something from it. Thank you
very good
Good knowledge
thanks
Very good