How to Fix Schneider Altistart 22 SCR Short Circuit Faults.

Поделиться
HTML-код
  • Опубликовано: 6 сен 2024
  • Save time troubleshooting your Altistart Soft Starter! This video shows you how to quickly measure the SCR to determine if it's healthy or faulty.

Комментарии • 7

  • @dennisdenock7354
    @dennisdenock7354 2 года назад +1

    Thanks Engineer, this is really helpful.
    Keep up with the good work

  • @kasmicmike4535
    @kasmicmike4535  2 года назад

    am happy to be of help

  • @pankajvaishnav6218
    @pankajvaishnav6218 4 месяца назад +1

    Sscr error solution

    • @kasmicmike4535
      @kasmicmike4535  4 месяца назад

      thanks for contacting us. SCR Fault is usually caused by shorting of the theristors or even shorting of the motor windings.
      to solve this is simply by
      1.replacing the SCR
      2. check motor for shorting

  • @kasmicmike4535
    @kasmicmike4535  Год назад

    www.mroelectric.com/blog/ats48-soft-start-troubleshooting-and-introduction/