Thanks for your comments and deep-sea configuration video has posted in our channel please check this link ruclips.net/video/4fFWw-ArKdA/видео.html Keep support our channel Thank you
This video most help for me ....thanking you sir.....and one more request please provide sedmac GC1211 controller software for me, we r facing lot of problems due to with out software...
Thanks a lot Sir. It was an extremely informative session. It cleared several of my doubts. I have a doubt regarding Deep Sea controllers. Can it be used for governing the speed of the Engine and adjusting the voltage of the AVR ? Please advice.
Thank you for your comments , i will make separate video for RS232 connection and external remote start operation very soon. Kindly support our channel Thank you Electrical Mastar
Welcome to you and we welcome this good and wonderful channel as wonderful as you are and I hope that you will accept me a new subscriber or a friend of yours and I have a question. And it is ... Does this scheme apply to all models of old and modern dpc screens and the same way of entering and adjusting them manually. How do we get all the old and new dpc programs and are there any One program for it deals with all versions of dpc screens. A thousand thanks and more success, waiting for you to respond with impatience.
Thank you so much Mr. Ahamed for your kind words, and yes one software is can able to support all type of dse controller but based on model type its having different functions. For that you need to check your des model catalogue . Thank you & keep support our channel
Thanks for your comments dear and dse downloading video as already i posted in our channel you can check here ruclips.net/video/KGfpaEBvxic/видео.html Keep support our channel Thank you 🙏
Hello sir, excellent explained by you. Sir in 250 kva DG DSE pin number 10,11 and 12 used for health indication. 10 for green light, 11 for yellow and 12 is red. Problem is when switching on exciter supply that time green light must glow but it is not working. At pin 10 need O/P 24V but it is missing. What are may be possible cause ? Pin 10 to indication lamp wiring is fine. DG is working only health warning light not working. DSE is 7320 mkii
Please help me I have dse 6120mk// showing low oil pressure sender fault in the events log , tried to run genset manual it's not working engine lube oil solenoid shutting off the fuel valve genset stopped working??
Thanks for your comments and low oil pressure means chance for oil level may get low or check coolant level is it okay, and finally check sender unit faultiness. This out of 3 option may be chance for gender stopped Thank you keep support our channel
Hi, how are you? I have a dse 6110 mpu 4.1 which only looks green on the display and I can't see the parameters and I would like to be able to adjust that
Thank you for your comments Mr. Trisha vijaya, For synchronization of DG and main supply you can use deep sea controller module 8610 which is having all protection for synchronization. For more about synchronization watch this video ruclips.net/video/dtIwx2zkiS4/видео.html
Thank you for your comments Mr. Deepthi Pathiratne, i will make separate video for DG parallel running with DSE controller Keep support our channel Thank you
Hi electric master. I have 3x125kva jcb generator failed to sync. The current version of the dse8610mkii is V4.1. I do all the same configuration of this 3 units but still failed to sync. Can you give me some tips boss.thanks
Hi Thanks for your comments and for sync or parallel operation please check this video it could be helpful for you ruclips.net/video/dtIwx2zkiS4/видео.html Thanks keep support us
Hello... For DSE 7320MKII Can you please explain oil pressure input (Type: DC6M-2) & coolant temp; sensor (Type: KAIZHOU) how can I set the input value for the shutdown alarms? Thank you
Could you elaborate more on the input 18,19 and 20? I have connected to the DSE 7410 through modem, however I could not able to get pass connecting to module. Do I have to run connect input for this before I can be able to connect to module?
Hello sir, i have 4 generators running it's been a while. Suddenly, one of the generators doesn't syncronize with others and doesn't get on bus. How should i find what's wrong? What should i check? Thank you
Bhai humare pas generator hai alternatior moro back side se jal gai Hai Jahan 2 wire lagi hoti hai D+ AND B+ Or mein Saudi Arabia Rehta Hun or bohat jagah se motor doondh raha hun kahin nai mili or kia alternatior motor ko 3 wire lagana zaruri hai ground Jahan D+B+ wire lagi ho pls muje batana humara jenrotr just crank start leta Hai 3 bar bad mein wo started to failed aata hai kia ye problem alternatior motor jalne ki Waja se hai ya koi or masla Hao muje batana pls meij kia kron I'll wait ur answers Humara generator 7320 kaii hai pls
Hi For lockout alarm and all protection relay system has linked with trip circuit that's why when DG get trip lockout relay also get activated Thank you
Amf- auto mains failure ( when mains supply will cut off, diesel Generater will be start automatically) ATS ( auto transfer switch) When Genset will start it will give load supplies from mains to DG
I got a massage on DSE controller (6110MHII AUTO START) Ramp up, Safety on delay & waiting for delay. even though the generator is running and given voltage. could anyone tell me why all these massages showing on display.
Hi Mr. Imran thanks for your comments and if DSE controller not count running hour then reset or reconfigure it then it will work . And if Gen set get continuous trip then check the alarm details in the event page and rectify it Thank you
you are a real electrical engineer sir Go a head, we will follow u intendedly
Thanks sir, good explain.
very good training i am waiting for more video
Thank you Mr. Gopal and keep support us 🙏🙏🙏🙏
@@electricalmastar Hello, very good videos but will you enable the option of other Spanish or English subtitles?
Thanks a job well done
Really helpful sir and easy to understand.
Thank you...
Great class sir thanks a lot, u can also add a practical video also so it will be more informative
Very clearly explained sir, really a great job, and thank you very much
Keep it going this usefull video ..appload the next concepts for the deapsea electronics and configration software.
Thanks for your comments and deep-sea configuration video has posted in our channel please check this link
ruclips.net/video/4fFWw-ArKdA/видео.html
Keep support our channel
Thank you
Great
thanks my friend
This video most help for me ....thanking you sir.....and one more request please provide sedmac GC1211 controller software for me, we r facing lot of problems due to with out software...
Thanks for your comments Mr. Prasad, let me check that software and let you know
Thanks
Super explained sir.
And with you don't mind you could make a video talking about EMCEP and DSE ...
Good I really like the explanation, i need to learn more about those, how can it be possible?
Thanks sir Good Explanation
i clearely understanad
Sir very nice to explain. We help oil pressure sensor fault comming .
How can we by pass please. Thank u
Nice engineer
Nice video sir, sir the pin no. 30, 31 is n.c this use for contactor of main power and then the 32,33 is n.o for contactor of generator. Thanks sir
Thanks a lot Sir. It was an extremely informative session. It cleared several of my doubts. I have a doubt regarding Deep Sea controllers. Can it be used for governing the speed of the Engine and adjusting the voltage of the AVR ? Please advice.
Thanks sir for explanation i really like, but can you please explain how to connect rs232 and external start and stop
Thank you for your comments , i will make separate video for RS232 connection and external remote start operation very soon.
Kindly support our channel
Thank you
Electrical Mastar
Hi dear can you share auto start video
thanks for your sharing. Please is it possible to have a PPT of contrôlers DSE73XX with DSE890 MKII.
Thanks for your comments and sorry I don't have the ppt for that now.
Thank you
Thank you with good video. May I request DSE 4620 wiring diagram please
does the 6110 have a set of dry contacts that can carry 2amps at 240 volts
superb video
Can I use the analog input signals for the ddc panel
Thanks for your comments and yes you can give analog input signal to dse panel
Thank you keep support us
Can this be used on a portable generator?
Thank you so mach
Sir can you make a video DSE and ECM wiring
May you explain me from where we can take and wire for 30 & 31 as well 32 & 33 using contactor and glass relay
Many thanks
Hello thanks can u plz guide on electrical interlock and how 30 to 33 are connected on the magnetic contactors
please tell me how i am engine start and stop another push button switch.
Sir
I Wish to convert cat 250kva control to deepsea. Which model i should choose. Need synchronization also. Pump with atuator. Plz help.
good day sir i need to knw how can i find
the wire to start a generator
Thanks alot
Hi sir, the generator could be auto start or on if the power system off
Hello sir do you know how to install software of smartgen control?
Pls conduct a class on calibration of this module
Do you have to use the SCR magnetic pick it up for the controller to work. Or can It pick up frequency from generator alternator?
Welcome to you and we welcome this good and wonderful channel as wonderful as you are and I hope that you will accept me a new subscriber or a friend of yours and I have a question. And it is ... Does this scheme apply to all models of old and modern dpc screens and the same way of entering and adjusting them manually. How do we get all the old and new dpc programs and are there any One program for it deals with all versions of dpc screens. A thousand thanks and more success, waiting for you to respond with impatience.
Thank you so much Mr. Ahamed for your kind words, and yes one software is can able to support all type of dse controller but based on model type its having different functions. For that you need to check your des model catalogue .
Thank you & keep support our channel
Please tell me how U connect fuel shut off solenoid?
Can i make parallel connection with primer fuel pump line?
EST solenoid not going on
sir would you like to explain to us, where is the pin used for Remote start function please?
thank you
Dear Sir,
Please give information about
Down load the program in controller
Thanks for your comments dear and dse downloading video as already i posted in our channel you can check here
ruclips.net/video/KGfpaEBvxic/видео.html
Keep support our channel
Thank you 🙏
Hello sir, excellent explained by you. Sir in 250 kva DG DSE pin number 10,11 and 12 used for health indication. 10 for green light, 11 for yellow and 12 is red. Problem is when switching on exciter supply that time green light must glow but it is not working. At pin 10 need O/P 24V but it is missing. What are may be possible cause ? Pin 10 to indication lamp wiring is fine. DG is working only health warning light not working. DSE is 7320 mkii
I need your help
Good morning, very nice explained,I want to also,, explained in Hindi language,, hope you are cooperate with us.
Good evening, pls I would like to get that control model shown
Electrical master please help me with the wiring diagrams of HGM6100N-RM
REMOTE CONTROL MODULE
Thanks for your comments let me try for your request
Thank you
Nice..
Explain about analogue inputs,outputs and digital input and output
Thank you for your comments Mr. Manoj, i will make separate video for input and output configuration
Keep support our channel
Thank you
Can you bypass the sensor alarms and still crank engine?
Please help me I have dse 6120mk// showing low oil pressure sender fault in the events log , tried to run genset manual it's not working engine lube oil solenoid shutting off the fuel valve genset stopped working??
Thanks for your comments and low oil pressure means chance for oil level may get low or check coolant level is it okay, and finally check sender unit faultiness. This out of 3 option may be chance for gender stopped
Thank you keep support our channel
@@electricalmastar thanks 😊
Hi, how are you? I have a dse 6110 mpu 4.1 which only looks green on the display and I can't see the parameters and I would like to be able to adjust that
Hello can you explain why emergency symbol appear on screen and shutdown the genset when the switch does not engaged
Hello. how to turn on the ignition without starting the engine ? DSE 7320
Hello Sir
Can you explain the wiring of PS0500 Cummins
hi. which icon in conroller mean DG running (DG started) ?
How can we by pass the low level coolant alarm or disable ? that causes the generator to shut down without using software.
hello sir, could you explain what protection we must use when phase angle is different between main bus and DG when syncrone?
Thank you for your comments Mr. Trisha vijaya,
For synchronization of DG and main supply you can use deep sea controller module 8610 which is having all protection for synchronization.
For more about synchronization watch this video ruclips.net/video/dtIwx2zkiS4/видео.html
Please explain how can we parallel CAT 500 Kva EMCP 4.2 controller with deep sea 8610 two sets with main supply
Thank you for your comments Mr. Deepthi Pathiratne,
i will make separate video for DG parallel running with DSE controller
Keep support our channel
Thank you
@@electricalmastar Sorry, In my case it should be CAT EMCP 4.1 with DSE 8610 and 500 kva dual generators
Sir for your kind information if you want synch with main utility then you need DSE 8620
thank u
Hi electric master. I have 3x125kva jcb generator failed to sync. The current version of the dse8610mkii is V4.1. I do all the same configuration of this 3 units but still failed to sync. Can you give me some tips boss.thanks
Hi
Thanks for your comments and for sync or parallel operation please check this video it could be helpful for you
ruclips.net/video/dtIwx2zkiS4/видео.html
Thanks keep support us
@@electricalmastar sure. Appreciate. One last thing do I need to update the firmware from V4.1 to 5.1. since I try so many times.thanks a lot
Try for the update may be it will work
Pls update esm perkins disel series 1300 clustemar conochan pls knolage for all ecm pls 🙏
Sir our deep model 7110 problem generator start after 5 mint's solenoid will come stop position ?what's the reason
Thanks for your comments, I think it's problem with stop solenoid coil check it
Thank you
which alarm show on deep sea may any safety active any input output active there thats why
Hello, how to wire if 3 phase 3 wire no neutral wire?
Hello...
For DSE 7320MKII
Can you please explain oil pressure input (Type: DC6M-2) & coolant temp; sensor (Type: KAIZHOU) how can I set the input value for the shutdown alarms? Thank you
Hi thanks for your comments and for oil pressure and coolant temperature set values you can get it from DG manual
Dear sir my deep sea controller is lighting can start and stop but shows nothing on the screen
Hello sir sadmack gcu bord repayer hoga
Which wire conect reset?
Can I explain DG645 location of hours sensor
❤❤❤
How to clear the fault alarm
Could you elaborate more on the input 18,19 and 20? I have connected to the DSE 7410 through modem, however I could not able to get pass connecting to module. Do I have to run connect input for this before I can be able to connect to module?
Cool
Deep sea 7510 in AUTO/Manual in runs few seconds it cools down and stops. Why is it doing that?
How to check RS485 port working
Sir, i want to know the connection for hours run in this controller
I got problem with my module was blank unable to reading anything,, any idea sir?
Thanks for your comments
There is some option called factory reset you can try that one
How can I reset a forgotten password?
Thanks
Anyone knows how to remove the pin on the module?
please i am seeking for electrical engineer specialist in synchro panel
Hello sir, i have 4 generators running it's been a while. Suddenly, one of the generators doesn't syncronize with others and doesn't get on bus. How should i find what's wrong? What should i check? Thank you
Bhai humare pas generator hai alternatior moro back side se jal gai Hai Jahan 2 wire lagi hoti hai D+ AND B+ Or mein Saudi Arabia Rehta Hun or bohat jagah se motor doondh raha hun kahin nai mili or kia alternatior motor ko 3 wire lagana zaruri hai ground Jahan D+B+ wire lagi ho pls muje batana humara jenrotr just crank start leta Hai 3 bar bad mein wo started to failed aata hai kia ye problem alternatior motor jalne ki Waja se hai ya koi or masla Hao muje batana pls meij kia kron I'll wait ur answers Humara generator 7320 kaii hai pls
HELLO TEACHER
Hi thanks for your comments and keep support our channel
Sir can i request the full conection between ats to genset diagram including battery charger... Thank you
Thanks for your comments sir, and check this Link it may be help you your query
ruclips.net/video/17FyXFWRT34/видео.html
Thank you
Sir deep sea 7110 model connection same ,
Thanks for your comments,
Yes it's same
Perking Engine genararator How to Case lockout Alaram
Hi
For lockout alarm and all protection relay system has linked with trip circuit that's why when DG get trip lockout relay also get activated
Thank you
Wht is the difference between this and amf, ats
Amf- auto mains failure ( when mains supply will cut off, diesel Generater will be start automatically)
ATS ( auto transfer switch)
When Genset will start it will give load supplies from mains to DG
Sir, it would have been nice to explain this video in Hindi language too..
Hello Sir I Want To Know MSc Data Failure Dse8610
Plz Help Me Msc Data Failure
bro how to sketchual it ?
Hello sir. Can u pls send me a clear schematic diagram of controller to dg.. Thanks
I got a massage on DSE controller (6110MHII AUTO START) Ramp up, Safety on delay & waiting for delay. even though the generator is running and given voltage. could anyone tell me why all these massages showing on display.
Thanks for your comments and those msg are inbuilt configuration for safety of device
I want to know config swith
Hi
For switch configuration i have posted another video you can check in the playlist
Thanks
Does anyone know what is AR and GFR in controller ?
Hi adeco fault and ECU red mean
How to use dse mkii 7320 with a single phase main PLS ?
Where we connect ATS connection
Dse 7320 controller not updating running hours and stop time the stop signal open close 3-4 times.
Hi Mr. Imran thanks for your comments and if DSE controller not count running hour then reset or reconfigure it then it will work . And if Gen set get continuous trip then check the alarm details in the event page and rectify it