Thanks for the video, but i have problem, when i've tried this tutorial, my vsd still can't running, could you help me sir? i use PLC Mitsubishi FX3U-14mr and ATV320
Because he used Rs-232BD Card for connecting FX3u-485ADP-MB Module maybe He Does not have CNV-BD Card. So, for that reason, He used D8420 Communication Format for the Module because now his module is configured as Channel 2 not Channel 1.
hello sir, my FX485 ADP only flashes SD, wiring is correct, and motor wont turn eventhough i already follow your instruction 100%. is there anything i miss?
first of all make sure that you communication card is connected to channel 2 same as showing in this video because according to my instincts you connected the module in first channel and try to communicate with VFD with 2nd Channel Command. The solution is either change the command into first channel or if you want to implement as same as showing in video then use any card in between module and plc like rs485-BD or RS-422-BD to make your module 2nd Channel.
Hello sir, i followed all your instructions, the code is 100% match. i use FX16MT and FR-E720S-075K. But still cannot connect. only SD flashes no RD. please help thank you very much
first of all make sure that you communication card is connected to channel 2 same as showing in this video because according to my instincts you connected the module in first channel and try to communicate with VFD with 2nd Channel Command. The solution is either change the command into first channel or if you want to implement as same as showing in video then use any card in between module and plc like rs485-BD or RS-422-BD to make your module 2nd Channel.
MITSUBISHI VFD E740 WAS created problem in NET MODE OPERATION These VFD run mode was auto Via PLC,HMI display through run Its vfd was run in Auto mode(NET MODE) But VFD frequency speed not up down only 0.0 Hz show HMI DISPLAY side showing speed 25.0HZ but still not run VFD PLEASE GET SOLUTION ME SIR I HAVE AN PR 79 MODE SELECT 2 PR 340 MODE IN SELECT 1 PLEASE NET MODE RELATED ALL PARAMETERS SETTINGS SEND SIR
I use IVDR & IVCK for modbus control..
And 4 wire connecting, this video 2 wire.. half duplex connection 👍👍👍
I always use IVDR instructions to this VFD and PLC mitsubishi, but this way its so much more elegant
Thanks a lot for the vedio. You helped me God bless you.
thanks for always share a nice content, god bless you
Nice content and thanks for sharing!
thanks sir
Thanks for the video, but i have problem, when i've tried this tutorial, my vsd still can't running, could you help me sir?
i use PLC Mitsubishi FX3U-14mr and ATV320
Perfect!!
please make a video which is communicate fx3u 485bd with yaskawa v1000 vfd
ruclips.net/video/UXXKE75SxIE/видео.html
Please see another modbus video.
Good Job And Thank You Bro
ruclips.net/video/UXXKE75SxIE/видео.html
Please see another modbus video.
ถ้า plc cj2m cpu32 เขียนการ modbus rtu rs-485 write and read inveter mitsubishi d700 เขียนยังงัยคับ
Thanks
thanks sir
PLC should be FX3U, Communication between two PLC wires RS485
ruclips.net/video/UXXKE75SxIE/видео.html
Please see another modbus video.
Please explain on ladder number 0 why you set mov H1087 to D8420
Because he used Rs-232BD Card for connecting FX3u-485ADP-MB Module maybe He Does not have CNV-BD Card. So, for that reason, He used D8420 Communication Format for the Module because now his module is configured as Channel 2 not Channel 1.
Can you please make also 2 inverter
very easy sir, only copy program and change slave address
@@plc247automation6 how about the program address do i need also to change sir? thank you so much
@@rodelreyes1418 ADPRW K1 > K2
@@plc247automation6 i got it thank for sharing sir
@@rodelreyes1418 ok thanks sir
Can i connect 25 frd700 vfd on 3u modbus
Can sir, 1 Master support 32 Station
Brother how to eneter in NET mode
hello sir, my FX485 ADP only flashes SD, wiring is correct, and motor wont turn eventhough i already follow your instruction 100%. is there anything i miss?
first of all make sure that you communication card is connected to channel 2 same as showing in this video because according to my instincts you connected the module in first channel and try to communicate with VFD with 2nd Channel Command. The solution is either change the command into first channel or if you want to implement as same as showing in video then use any card in between module and plc like rs485-BD or RS-422-BD to make your module 2nd Channel.
@@fazimalik5214 sir cant i contact you?
Hello sir, i followed all your instructions, the code is 100% match.
i use FX16MT and FR-E720S-075K. But still cannot connect.
only SD flashes no RD. please help thank you very much
first of all make sure that you communication card is connected to channel 2 same as showing in this video because according to my instincts you connected the module in first channel and try to communicate with VFD with 2nd Channel Command. The solution is either change the command into first channel or if you want to implement as same as showing in video then use any card in between module and plc like rs485-BD or RS-422-BD to make your module 2nd Channel.
MITSUBISHI VFD E740 WAS created problem in NET MODE OPERATION
These VFD run mode was auto
Via PLC,HMI display through run
Its vfd was run in Auto mode(NET MODE) But VFD frequency speed not up down only 0.0 Hz show
HMI DISPLAY side showing speed 25.0HZ but still not run VFD
PLEASE GET SOLUTION ME
SIR
I HAVE AN PR 79 MODE SELECT 2
PR 340 MODE IN SELECT 1
PLEASE NET MODE RELATED ALL PARAMETERS SETTINGS SEND SIR
How to write acc and dcc time on inversor?
Thanks!
check address on Manual
2,3 drive connect program and setting
Model HPE-M8Q9-TRRR-J to Delta hmi Dop-107BV programing video plz
Sir please FX3U PLC to FR-A800 Series Mitsubishi VFD Drive RTU Mode communication video create please...
FR-A800 Same 100% sir
Hi