EDIT 4/29/24 - Starting March 2024, this product ships with the CHINT CB-125A DC circuit breaker. ==== The following no longer applies === WARNING: The circuit breaker used in this product is a AC breaker which does not include arc suppression like in DC breakers. Therefore, do not buy this item until I get a green light from the manufacturer that they updated the circuit breaker.
There are some AC circuit breakers that are ok for DC use you have to look up the spec sheets to find out. NoArk for example have many rated for DC use at 48 volts.
A few notes: 100Ah cells can discharge 1000 to 2000A when shorted. No BMS there to stop it. The "100A" 1C discharge is a BMS limitation and also BMS-enforced, so externally the BMS won't allow continuous discharge above that. But many BMSs and cells have no trouble allowing 2x or 4x (200A, 400A in this case) discharging for a few seconds. These are mostly limitations of the BMS, not so much the cells. The cells are certainly happier when charged and discharged below 1C... less stress, higher efficiency, but there is no hard-stop. Inverter disconnect should typically be set at 48.0V and not much lower. Even though the cells can tolerate going lower, the pack will be 95% discharged at 48.0V so there is not much of a point allowing it to go lower. For tools, even with the extension you are sticking a lot of metal into a battery box. Don't do that! At least wrap the exposed bits with electrical tape as much as practical. Or buy properly insulated tools. In terms of touching 48V... as long as your hands are dry, the most you will get is a light buzz. If your hands are wet or sweaty though, don't be messing around. More importantly, 48V can produce a substantial arc when you make a mistake, so don't stick your face close to 48V wire / bare metal, you don't want an accidental arc to permanently screw up your vision. And a substantial amount of power is involved if you actually short anything, even when the BMS is there to save you, so even though you can touch 48V with your bare hands, you still need to be careful when messing around with cables. Always de-energize the wiring or cabling (when possible) before messing with it. People often add extra 2-pole breakers for this purpose... just to make working on the equipment more convenient. In anycase, there are many advantages to 48V, not the least of which being able to use far lower-amperage solar charge controllers and far, far, far lower cabling losses, being able to use far smaller cables, and far less heat produced from the equipment. -Matt
Dude, you totally rock, I am now encouraged to finally start on my DIY, I also will be using 48 volts, also I wanted to let you know that using a 20 volt drill on a 48 volt system; with 48 volt nuts, might by dangerous, be careful please, don't be nuts!
You have a point. I probably should use insulated wrenches and screwdrivers when touching the cell terminals. The 20V drill though, is metallic but 'shouldn't' have a voltage connected to the tip.
Excellent video! I like your explanation on the low temp CHARGE vs DISCHARGE settings. Other sites do not seem to fully test and explain or hold the manufacturer accountable for proper documentation. Keep up the great work and clear explanations, thank you.
48v with lead-acid is also not 48v. Each lead-acid cell is 2.1v nominal, hence the 12v car battery at full resting voltage of 12.6v, and charge voltage as high as 14v to 15v. This matches well a 4 cell LiFePO4 lithium battery, with a nominal voltage of 12.8v (3.2v/cell) and a charge voltage as high as 14.6v. Put 4 of those in series for 48v and you get 51.2v nominal and a charge voltage as high as 58.4v.
At my offgrid cabin, we use an EEL DIY 12v boxes w/ 200A BMS, MB31 cells at 304Ah, we have two of them. My cabin is 90% 12v, basically runs like an RV...fridge, lights, water pump, hot water heater, etc. AC for cooling is 120Vac mini split and we have maybe 5 outlets for 120Vac devices. Small solar at 2Kw which is mostly to run the AC unit, originally was 400W. At my house we have 4 server rack Gobel Power boxes, also DIY builds, just add batteries, 2 @ 280Ah and 2 at 304Ah, all with the same JK BMS at 200A. The batteries talk to the inverter without issue. Your 100Ah batteries give you 5.2Kwh, where my little ones are 10.8Kwh and the two bigger ones are 15Kwh. I do not export to the grid, I use the solar power and charge the batteries as I'm in CA where its nearly pointless on NEM3.0 to export. I would have to export 15Kw to "pay for" 1Kw of grid. More batteries, the better.
Great review! The gear is just getting better and better. I'd love to see a 100A load open case with an IR camera to see those wire temps. Is it a weak link?
I was told the worst case is 80C so this will be under the 125C of the heat shrink and 200c limit of the cable insulation. Externally, I don't like things to go over 60C since that is hot to the touch. I am curious myself so I'll be running tests on this soon.
Great video man. I love how your video's have grown both in professionalism and content as your channel has progressed. Well done buddy. Aussie in Asia appreciating the help :)
I just had a 18 250w solar panel, 8 5120Wh rack mount battery system using dual Victron solar controller dual inverter system in my motorhome. It was depressingly expensive. I replaced my 3 AC units with Furrion Cube AC units with variable speed compressors to get mini-split efficiency. Total cost was about $33k with everything included. Depressing but it'll be worth it when I boondock. I got the exact same batteries but from a different vendor.
Yeah, batteries are very hard to get a good ROI. You end up paying the price to be energy independent which is worth every penny when there is no power.
Server rack style is great but I prefer 4x12 series for 48V. Still can use individual 12V batteries in back up systems if one fails. Server rack goes out and you’ve lost 5.12kW in one swoop. 4x12 and lose a battery take the remaining good battery(s) and hook up to backup 12V rig and keep the lights on.
Question for you. Have you ever lost one of the 12V battery in 48V system? I am interested in the failure mode. If it does fail, the others are likely not far behind.
Good stuff. But a ground protector pad ... and insulated gloves for the demo ... are better "bedside" manner, cause lots of people are accidental welders ... than the enguneer who knows . LOL.
12 volt is my go to system no matter how many people use 48 volt. I feel comfortable with a BMS system in the batteries for added protection. People always say there is something better but that is a relative term. I like the tried and tested 12 volt system and without all that inverting and converting back and forth. But it amounts to what works best for your needs. Mine are very simple and uncomplicated. Next week someone will have a 96 volt system and and say it is better than the 48 volt. I'm enjoying the benefits of a 12 volt system which matches my 12 volt products; no mess; no fuss; no thrills, but gets the job done.
If you have a lot of 12V devices consuming significant energy, it does make sense to stay at 12V indeed. If you're using mostly AC voltage, 48V or higher is better to minimize cable losses.
If I had the skill you have, and I already had the wire, would you recommend changing out the INetrnal DC large wires for much larger AWG welding cable?
The internal wires get warm but it will be well within the limits of the heat shrink and insulation internally. You wouldn't want to touch and hold them but you cannot do it anyway since they are normally inside. They waste a bit of energy from heating so I would check how much energy it wastes vs the cost of the mod.
I like your review style a lot! You should do more batteries 🙂 Does the BMS have passive balancing and if so how many mA? And what is the criterion to start balancing? May look like a detail but may be important in the long term. Also does it have an inrush current circuit?
Yes it has leads to all cells in the battery for balancing. Not sure about the max mA it can do though. When using it, I have seen the balancing kick on pretty easily within the app. No mention of inrush current circuit. (in this case, it is current rushing out into the inverter)
Hey Francis. Love your content specially I am also in Bay Area San Jose area. I recently think of build the off grid solar system with Ecoflow brand. Bought used solar panels locally. Question is, do I need a permit to build this kind of system since it is not tied to PGE grid. Thank you for your input
First, I LOVE your videos, always great stuff and created very professionally. Thanks for making things simpler. My question is, can this system be recharged with a standard 120/240v gas/propane generator? Thanks again, great stuff.
I'd like to replace a lead acid 48v piece of equipment but worried that the 16 cell lithium will be outside spec on rhe nominal and charge voltage. Would it be better to go with 15 cells pack?
Generally, you better have a charge controller that is compatible with a LiFePO battery if you will use one. You can easily over charge or over discharge it with the wrong controller.
It depends if you will be making a 48V system. In that case you have to add in the fuse, wires, lugs, tools, battery balancer, wireless connection monitor to the cost of the goldenmate. This one you get all of that in one package.
It's not stated in the manual but I would guess 5120Wh flows out = 1 cycle. So you can flow half, charge half, then flow another half, then that equals 1 cycle. I doubt it would keep track of lower capacity as it ages though.
One full cycle is typically counted as 95% discharged. If a LiFePO4 battery is discharged 50% and then charged, then discharged 50%, then charged a second time... that basically counts as one cycle. All LiFePO4 cells are roughly similar in terms of cycle life, but marketing materials vary and will market different numbers for different 'depths of discharge'. That said, there are some differences depending on the manufacturer. Pouch cells typically have a higher cycle life than prismatic cells, but prismatic cells are more robust. Also, it is far less stressful on the battery to cycle the top of the battery than the bottom. The bottom of the battery is where most of the damage actually occurs. So it is very typical to charge to 100% and have the low-voltage cut-off at 5% (roughly 48.0 volts for a 16s pack is 95% discharged). No need to let it discharge further than that.
Maybe off topic from this video, but......Not having an engineering background, I am still confused about voltage. Household voltage is referred to as 110v or 120v? Half of 240v being 120v makes sense versus 110v. Power Tools can be found as 3v, 6v, 12v, 18v, 20v 24v, 48v? (X *2) or +6v seems like the logic so the 20v makes no sense to me in this example for some reason. US voltage is designed lower/safer than higher European voltage, but I used a $3 cheap plastic adapter off the street and the phone charges just fine.
Just because power tools are usually a certain voltage, doesn't mean they have to be. They standardize on those so it's easy to understand. The voltage of the battery is dependent on the chemistry. Yes, a cheap power adapter works but there may be features not included such as short circuit protection, low ripple of the output current, longevity, compatibility with various USB protocols, etc.
Most of the time the actual number isn't critical. The U.S. 120v is a nominal number. The actual voltage is allowed to vary from 104v to 127v with a goal to keep it within 108v to 125v. This is from ANSI C84.1 first published in the 1950s and revised multiple times since then. The nominal value used to be 110v(220v) and for a time was 115v(230v) and is now 120v(240v). Europe went thru similar changes and widened the tolerance range in various countries in order to unify their power grid. And note that those are all average (Root Mean Square or RMS) values, being the D.C. equivalent of a sine wave A.C. voltage. The peak value of a 120v RMS sine wave is over 170v. Batteries are similar. The common lithium power tool battery uses 5 series cells with a chemistry producing 3.7v to 3.8v nominal at resting full charge. But fully discharged they might be 3.0v and the max charge voltage is up to 4.2v. But often the charger will limit to 4.1v and shut off, at which point the cell will fairly quickly drop to 4.0v. This means the 5 series cells range from 15v to 21v resulting in manufacturers claiming 18v or 20v most commonly. Kobalt uses 6 series cells and calls it 24v. The Ryobi and Greenworks and Kobalt 40v outdoor power tools use 10 series cells. Ego 56v is 14 cells. Etc. It's all pretty lose, because it is just chemical reactions (batteries) and big mechanical equipment (grid power production). This means anything critical needs to have a voltage regulator and filtering to give it a precise and stable voltage. Your USB "charger" is actually a power adaptor and regulator producing the correct voltage(s) and power levels defined by the USB standard (5v +/- 5% at 0.5a was the original, 1.0a and up to 2.0a are common with the device taking what it needs up to those levels, and it only gets more complicated from there with Quick Charge and USB-C Power Delivery (PD)).
Aluminum doesn't necessarily mean it is bad as long as it can carry the current capacity stated and remain under the design temperature in the worst case scenario. So if they use aluminum, yes, they have to use thicker wires to make up for not being copper to meet the same specifications.
So let me ask the question here if you have a 12 volt battery at 100 amp hour is that the same as a 48 volt 25 amp hour battery and vice versa if you have a 48 volt 100 amp hour battery that's the same as having a 12 volt battery with 400 amp hour. Is that right?
50 Watts is fixed when the inverter is on. You can have it power down if it uses less than 50 Watts after a period of time. In order to make it worth while, you'd have to have enough solar to compensate.
What issues can occur if four 12v LFP batteries put in series (making a 48v bank) then connecting the bank to a 48v LFP rack mount battery like the one in the video? I don't believe it is a good idea as BMS conflict may occur or is this possible?
You are better off with all your batteries managed by 1 bms if you have a 24 system, you want all the cells per 24v managed by the same bms so it.can keep them all in balance. Stringing together multiple batteries to increase your voltage can be problematic Because you can run into balancing issues purbattery in the series chain. Granted you can put in battery balancers but still that is not really ideal
@@BeatTheBush 1 hour does not refer to 5 kW but Ah. I have heard that I couldn't do this directy from solar panels and inverter and there has to be a battery
Picked up this on Amazon Prime Day with a 15% discount getting it down to $934.98, then an additional 7% discount getting it down to 869.53 pre tax shipped to my door ($941.27 estimated post tax). That's $0.17-$0.18 per Wh!!! Can't beat it. Now if only I could find a way to modify it to add a RJ45 connector..... @BeatTheBush Is there a way you know of to add a RJ45 unit to the BMS to make it have communications to other devices? I saw an empty connector on the BMS, not sure what that's used for or if that would work? Or maybe one would have to swap utility of the screen to have the cable?
Why we stop at 48v nominal? Not just an arbitrary number. Its due to safety classification. ...The white paper compares NEC to ANSI Standards. It sites the following NEC voltage standards: High Distribution - 1000 to 4160 volts Medium Distribution - 50 to 1000 volts Low Distribution - 0 to 49 volts
I have been running a 120vdc bank since 2008. Not 120 ac but 120dc. 10 x 12v in series or 60 forklift cells. I am hoping to upgrade to lithium iron say 5 x 24volt in series. Would it work? Could I just wire them in series and their individual boards look after themselves. Would this work OK. I still use the 2kw inverter and 2 kW controllers installed in 2008.
Probably cannot help you design your whole system from just one comment. You do need to see if the DC output range is compatible with your inverter input. 120VDC is not typical.
@BeatTheBush Back then. There were only 5 of with 120vdc systems. I believe ,I am now the last one. Everyone has switched to lipo 4 48vdc. I would like to keep the old Chinese inverter and controllers. They are bullet proof. We also a a 120 vdc wind turbine which uses 2 x 138vdc immersion as dump loads. The PV 5KW approx also goes through the WT dump load relays. It works very well. I also run my workshop of it. The old iron core. Low frequency 2kw inverter is very dependable and used less on standby. For bigger power. I use the 120 vdc 4 power module Symettra rm. Or when I am cutting the lawn I boot up an Eason Compac 3 000 again 120vdc 2.7kw. It would be handy if zi could switch over onto 5 x 200ah x 120vdc lithium iron.
5-24V LiFePO batteries would range in voltage from 100-146V DC. You must make sure the previous system can operate at this range. Lead acid voltage would have went up to only 130V. So your charge controller needs to know how to charge this type of battery.
I just received this same battery from Vatrer. Mine when it hits COV has cell#1 at 3.713V and the rest at 3.4 volts. I contacted Vatrer and they said 300mV difference is normal. Lol, no. Having a cell peak at 3.713V while the rest are at 3.4V is not good. Does your battery do this or are all cells balanced well below 300mV diff when COV MODE cuts charging?
3.65V is the limit so going there is really bad for the cell. If you look at 11:34, the top voltage is 3.624V. The issue is not a 300mV difference but the highest voltage each cell attains. Perhaps one cell is a little lower in capacity so it charges much faster. You might want to discharge it a little and let the balancing work to equalize the energy. Then recharge it back to 100% to see if it does the same thing.
Thank you for the reply. Yes 3.65V is max and certainly not good to float there, 3.713V like mine even worse, all cells except #1 go no higher than 3.4 to 3.45 but the cell#1 is ovrecharging/peaking at 3.713V then battery bms goes into COV while the other cells sit around 3.35v to 3.4V. I like your pack balance distribution better. Yes, I was going to manually deplete a little off of cell#1 and I suggested me doing just that earlier to Vatrer but they didn't address that. They just had their tech say it is all normal and fine with the one cell peaking at 3.713V while all others are at 3.4V.... but we know better. 😉 I was giving it a few cycles to see if it would balance out on its own, but I think I will go ahead and do a minor manual depletion on cell#1 while I have it apart relocating the bluetooth module to the back of the LCD display so it get get some signal out. First thing I noticed after the cell mismatch was the poor range of Bluetooth. I build my own packs and bought this battery so I would not have to match and manage varying balance of salvaged LFP cells, just to manually balance new grade A eve LFP cells...😂
Might want to look into sodium Ion batteries. They're' just starting to be mass produced. They can operate down to 14 F. Of course some Lifepo4 batteries have built in heaters but they cost more.
The problem with 48v is that when you want to step up and increase your storage rating you have to buy 16 cells, 8 cells for 24v and only 4 cells for 12v, I'm with 24v.
I was comparing a 48V system to a 48V system with four 12V batteries. Not a 12V system with 4 batteries in parallel where it's a true 12V system. 100A on the 48V would equate to needing 400A capable wiring for the 12V system. The cost differential is in the hundred or two.
48 volts has been the standard for over 100 years in the telco industry I know of no deaths from it worked with it for over 30 years. You save dollars not nickels when you have systems that are in thousands of watts copper is expensive and batteries last longer by drawing smaller currents.
Thanks for pointing this out. To me, this is a very serious issue and will pull the purchase link from the video description for now. I will suggest the manufacturer update this to a DC breaker, possibly have them send me a retrofit one and update the product if possible.
@@BeatTheBush I know but Huawei inverters has some models which area battery ready and they accept only Huawei batteries. I read somewhere they are high voltage batteries.
Yes it is! I just noticed that battery doesn't have communication ports on it. Is that or the touchscreen monitor really necessary with the bluetooth that it has installed on the BMS.? How well of a bluetooth signal do you get with that metal case? Thank you for this video and response to my questions.Much appreciated..@@BeatTheBush
First 2 minutes, info : OK. Newtons' Laws state '' energy is not lost - only transformed ''. There is a mid-point, between WIRE size/insulation properties , due to Physics Laws. ONE, must choose, WHAT voltage is needed, for the (your ! ) Applications. For most, 48 volts is fine ; 4800 watts. That, would power heaters, small stove, and most AC units, as well as any fridge, washing machine, small electric dryers, probably All lights. The Balance, point, of Cost /versus Needs , must be CHOSEN WISELY. Always, All Ways,....leave your options, OPEN, for expansion; over time hi-tech will modify, slightly, ACCORDING TO THE ABOVE LAWS, OF PHYSICS / ELECTRONICS /ELECTRONS.....and wires !
Math is math.... Batteries dont make more power because you go from 12v to 24v. 2 - 12v , 100ah batteries = 2400 watts regardless of whether in series or parallel.
people with 4 12v inverters could connect their inverters in series to a 48v battery 😜, joking don't do this. It's good to check, check, check, check & check again when connecting the bus bars. I had a brain fart and had 2 cells shorted and scared the crap out of me, im lucky the aluminum bus bar didn't weld itself.
I have an issue with the video. You state about the higher the voltage the more dangerous it is. Then you take apart the battery connections without protective gloves. Then you comment that you're an engineer and how its a 100a system. Basically what I'm getting at is you're setting a bad example by not using protective gloves. The first thing you are taught about working with electricity is safety. Kids watch your videos. Set the proper example not just by talking of the dangers but showing how to do things in a safe manner.
Human skin conductivity is low enough it’s fine. For him to touch the connections when current is not running its safe. What’s important is to avoid dropping an uninsulated tool across positive and negative terminals. If you let your kids near this that’s adult supervision negligence.
@@rabbitpumpkin8279 so now blame the parents. I think we are all parents. As such we all help as a collective. I will defend a child from a danger. Even if I'm a complete stranger to that child. Not just children though, I've done alot in my lifetime to protect life and property. I don't want to do something that could harm anyone. I would hope that the op would think the same. Besides if the op was to find himself looking for a job this vid could be bad. Many employers do deep background checks on job candidates. If an employer was to view this vid and note the same thing that I saw this could be used against hiring the op.
That was a great video! I've never seen the 100Ah EVE cells before, got 16 of the 280Ah ones recently. Was glad to see him take the pack apart and seeing the smaller ones here!
EDIT 4/29/24 -
Starting March 2024, this product ships with the CHINT CB-125A DC circuit breaker.
==== The following no longer applies ===
WARNING: The circuit breaker used in this product is a AC breaker which does not include arc suppression like in DC breakers. Therefore, do not buy this item until I get a green light from the manufacturer that they updated the circuit breaker.
There are some AC circuit breakers that are ok for DC use you have to look up the spec sheets to find out. NoArk for example have many rated for DC use at 48 volts.
Is there a breaker replacement you'd recommend for those that have already purchased the unit?
Please keep us updated.
@@gridlessbob993 appreciate the share!
Also… a sketchy 15S version they sell advertised as 48V
A few notes:
100Ah cells can discharge 1000 to 2000A when shorted. No BMS there to stop it. The "100A" 1C discharge is a BMS limitation and also BMS-enforced, so externally the BMS won't allow continuous discharge above that. But many BMSs and cells have no trouble allowing 2x or 4x (200A, 400A in this case) discharging for a few seconds. These are mostly limitations of the BMS, not so much the cells. The cells are certainly happier when charged and discharged below 1C... less stress, higher efficiency, but there is no hard-stop.
Inverter disconnect should typically be set at 48.0V and not much lower. Even though the cells can tolerate going lower, the pack will be 95% discharged at 48.0V so there is not much of a point allowing it to go lower.
For tools, even with the extension you are sticking a lot of metal into a battery box. Don't do that! At least wrap the exposed bits with electrical tape as much as practical. Or buy properly insulated tools.
In terms of touching 48V... as long as your hands are dry, the most you will get is a light buzz. If your hands are wet or sweaty though, don't be messing around. More importantly, 48V can produce a substantial arc when you make a mistake, so don't stick your face close to 48V wire / bare metal, you don't want an accidental arc to permanently screw up your vision.
And a substantial amount of power is involved if you actually short anything, even when the BMS is there to save you, so even though you can touch 48V with your bare hands, you still need to be careful when messing around with cables. Always de-energize the wiring or cabling (when possible) before messing with it. People often add extra 2-pole breakers for this purpose... just to make working on the equipment more convenient.
In anycase, there are many advantages to 48V, not the least of which being able to use far lower-amperage solar charge controllers and far, far, far lower cabling losses, being able to use far smaller cables, and far less heat produced from the equipment.
-Matt
Love this! I can't wait until we buy a property again and can go all out on solar & battery backup here in Mexico.
Good info. Battery options have definitely improved a lot in recent years. What was best to do a few years ago is more expensive now.
Dude, you totally rock, I am now encouraged to finally start on my DIY, I also will be using 48 volts, also I wanted to let you know that using a 20 volt drill on a 48 volt system; with 48 volt nuts, might by dangerous, be careful please, don't be nuts!
You have a point. I probably should use insulated wrenches and screwdrivers when touching the cell terminals. The 20V drill though, is metallic but 'shouldn't' have a voltage connected to the tip.
Excellent video!
I like your explanation on the low temp CHARGE vs DISCHARGE settings. Other sites do not seem to fully test and explain or hold the manufacturer accountable for proper documentation.
Keep up the great work and clear explanations, thank you.
48v with lead-acid is also not 48v. Each lead-acid cell is 2.1v nominal, hence the 12v car battery at full resting voltage of 12.6v, and charge voltage as high as 14v to 15v. This matches well a 4 cell LiFePO4 lithium battery, with a nominal voltage of 12.8v (3.2v/cell) and a charge voltage as high as 14.6v. Put 4 of those in series for 48v and you get 51.2v nominal and a charge voltage as high as 58.4v.
48v dc is the safe limit of voltage there is a good reason for it
At my offgrid cabin, we use an EEL DIY 12v boxes w/ 200A BMS, MB31 cells at 304Ah, we have two of them. My cabin is 90% 12v, basically runs like an RV...fridge, lights, water pump, hot water heater, etc. AC for cooling is 120Vac mini split and we have maybe 5 outlets for 120Vac devices. Small solar at 2Kw which is mostly to run the AC unit, originally was 400W. At my house we have 4 server rack Gobel Power boxes, also DIY builds, just add batteries, 2 @ 280Ah and 2 at 304Ah, all with the same JK BMS at 200A. The batteries talk to the inverter without issue. Your 100Ah batteries give you 5.2Kwh, where my little ones are 10.8Kwh and the two bigger ones are 15Kwh. I do not export to the grid, I use the solar power and charge the batteries as I'm in CA where its nearly pointless on NEM3.0 to export. I would have to export 15Kw to "pay for" 1Kw of grid. More batteries, the better.
I sub to channels that can teach me something. This absolutely fits the bill. Thanks.
Great review! The gear is just getting better and better.
I'd love to see a 100A load open case with an IR camera to see those wire temps. Is it a weak link?
I was told the worst case is 80C so this will be under the 125C of the heat shrink and 200c limit of the cable insulation. Externally, I don't like things to go over 60C since that is hot to the touch. I am curious myself so I'll be running tests on this soon.
Great video man.
I love how your video's have grown both in professionalism and content as your channel has progressed.
Well done buddy.
Aussie in Asia appreciating the help :)
Excellent review!
I have two of these batteries and LOVE THEM!
I just had a 18 250w solar panel, 8 5120Wh rack mount battery system using dual Victron solar controller dual inverter system in my motorhome. It was depressingly expensive. I replaced my 3 AC units with Furrion Cube AC units with variable speed compressors to get mini-split efficiency. Total cost was about $33k with everything included. Depressing but it'll be worth it when I boondock. I got the exact same batteries but from a different vendor.
Yeah, batteries are very hard to get a good ROI. You end up paying the price to be energy independent which is worth every penny when there is no power.
Hi. I sure could use your help with putting together a really cool set up for my van I’m guessing I need 5 to 10 kWh system I think
Could you do a wire diagram doing theses units in series’s and how would you change with a generator?
Server rack style is great but I prefer 4x12 series for 48V.
Still can use individual 12V batteries in back up systems if one fails. Server rack goes out and you’ve lost 5.12kW in one swoop. 4x12 and lose a battery take the remaining good battery(s) and hook up to backup 12V rig and keep the lights on.
Question for you. Have you ever lost one of the 12V battery in 48V system? I am interested in the failure mode. If it does fail, the others are likely not far behind.
Good stuff. But a ground protector pad ... and insulated gloves for the demo ... are better "bedside" manner, cause lots of people are accidental welders ... than the enguneer who knows . LOL.
12 volt is my go to system no matter how many people use 48 volt. I feel comfortable with a BMS system in the batteries for added protection. People always say there is something better but that is a relative term. I like the tried and tested 12 volt system and without all that inverting and converting back and forth. But it amounts to what works best for your needs. Mine are very simple and uncomplicated. Next week someone will have a 96 volt system and and say it is better than the 48 volt. I'm enjoying the benefits of a 12 volt system which matches my 12 volt products; no mess; no fuss; no thrills, but gets the job done.
If you have a lot of 12V devices consuming significant energy, it does make sense to stay at 12V indeed. If you're using mostly AC voltage, 48V or higher is better to minimize cable losses.
You get 4x the run time. Also 12v makes alot of heat running ac and bigger stuff and that's a loss of energy. You don't get that with 48v
Thanks for a great video and information. Any comments on this VATRER Battery vs the LifePo4 V2 48V 100 AH?? Thx!
If I had the skill you have, and I already had the wire, would you recommend changing out the INetrnal DC large wires for much larger AWG welding cable?
The internal wires get warm but it will be well within the limits of the heat shrink and insulation internally. You wouldn't want to touch and hold them but you cannot do it anyway since they are normally inside. They waste a bit of energy from heating so I would check how much energy it wastes vs the cost of the mod.
I like your review style a lot! You should do more batteries 🙂 Does the BMS have passive balancing and if so how many mA? And what is the criterion to start balancing? May look like a detail but may be important in the long term. Also does it have an inrush current circuit?
Yes it has leads to all cells in the battery for balancing. Not sure about the max mA it can do though. When using it, I have seen the balancing kick on pretty easily within the app. No mention of inrush current circuit. (in this case, it is current rushing out into the inverter)
@@BeatTheBush cool thanks
Hey Francis. Love your content specially I am also in Bay Area San Jose area. I recently think of build the off grid solar system with Ecoflow brand. Bought used solar panels locally.
Question is, do I need a permit to build this kind of system since it is not tied to PGE grid.
Thank you for your input
First, I LOVE your videos, always great stuff and created very professionally. Thanks for making things simpler. My question is, can this system be recharged with a standard 120/240v gas/propane generator? Thanks again, great stuff.
Yes you can limit the current draw to the most efficient level for your generator.
Love your content bro very informative
Can you make a video on how you switch your grid tied inverter on remotely or automatically for your excess solar
I have a free screenshots of this in the $10/month electric bill video.
Thanks for the info! Plus, I think you have a great sense of humor haha
Thanks for the review. I have a Vatrer also. What gauge wire are you using between your inverter and MCCB, and MCCB and T class fuse?
2 awg but I really should move them to 0 awg.
What do you do about permits / regulations? Do you claim the tax rebate on those?
I'd like to replace a lead acid 48v piece of equipment but worried that the 16 cell lithium will be outside spec on rhe nominal and charge voltage. Would it be better to go with 15 cells pack?
Generally, you better have a charge controller that is compatible with a LiFePO battery if you will use one. You can easily over charge or over discharge it with the wrong controller.
A 48v 100ah lifepo4 is $1000 and a 12v 100lifepo4 is $200. Would they last the same amount of time or how would efficiency work?
Power = Voltage x Current
48V 100Ah = 4800Wh
12V 100Ah = 1200Wh
48V one would last 4 times as long at the same power draw.
Can your inverter talk to it on closed loop?
No, there is no such function with this rack mount battery. It can only see the voltage at the inverter terminals.
I still feel the goldenmate battery is still the best for the buck in terms of dollar per kWh after the coupon code. Correct me if I’m wrong
It depends if you will be making a 48V system. In that case you have to add in the fuse, wires, lugs, tools, battery balancer, wireless connection monitor to the cost of the goldenmate. This one you get all of that in one package.
@@BeatTheBush And being all in one package the BMS can better balance all 16 cells, instead of 4 groups of 4 cells balanced separately.
I'm glad my smart online electrical engineer brother is here to disassemble this and analyze it :)
@9:05 what counts as a cycle?
It's not stated in the manual but I would guess 5120Wh flows out = 1 cycle. So you can flow half, charge half, then flow another half, then that equals 1 cycle. I doubt it would keep track of lower capacity as it ages though.
One full cycle is typically counted as 95% discharged. If a LiFePO4 battery is discharged 50% and then charged, then discharged 50%, then charged a second time... that basically counts as one cycle.
All LiFePO4 cells are roughly similar in terms of cycle life, but marketing materials vary and will market different numbers for different 'depths of discharge'. That said, there are some differences depending on the manufacturer. Pouch cells typically have a higher cycle life than prismatic cells, but prismatic cells are more robust.
Also, it is far less stressful on the battery to cycle the top of the battery than the bottom. The bottom of the battery is where most of the damage actually occurs. So it is very typical to charge to 100% and have the low-voltage cut-off at 5% (roughly 48.0 volts for a 16s pack is 95% discharged). No need to let it discharge further than that.
Interesting :)
Thanks so much
Maybe off topic from this video, but......Not having an engineering background, I am still confused about voltage. Household voltage is referred to as 110v or 120v? Half of 240v being 120v makes sense versus 110v. Power Tools can be found as 3v, 6v, 12v, 18v, 20v 24v, 48v? (X *2) or +6v seems like the logic so the 20v makes no sense to me in this example for some reason. US voltage is designed lower/safer than higher European voltage, but I used a $3 cheap plastic adapter off the street and the phone charges just fine.
Look up technology connections "120V"
Just because power tools are usually a certain voltage, doesn't mean they have to be. They standardize on those so it's easy to understand. The voltage of the battery is dependent on the chemistry.
Yes, a cheap power adapter works but there may be features not included such as short circuit protection, low ripple of the output current, longevity, compatibility with various USB protocols, etc.
Most of the time the actual number isn't critical. The U.S. 120v is a nominal number. The actual voltage is allowed to vary from 104v to 127v with a goal to keep it within 108v to 125v. This is from ANSI C84.1 first published in the 1950s and revised multiple times since then. The nominal value used to be 110v(220v) and for a time was 115v(230v) and is now 120v(240v). Europe went thru similar changes and widened the tolerance range in various countries in order to unify their power grid.
And note that those are all average (Root Mean Square or RMS) values, being the D.C. equivalent of a sine wave A.C. voltage. The peak value of a 120v RMS sine wave is over 170v.
Batteries are similar. The common lithium power tool battery uses 5 series cells with a chemistry producing 3.7v to 3.8v nominal at resting full charge. But fully discharged they might be 3.0v and the max charge voltage is up to 4.2v. But often the charger will limit to 4.1v and shut off, at which point the cell will fairly quickly drop to 4.0v. This means the 5 series cells range from 15v to 21v resulting in manufacturers claiming 18v or 20v most commonly. Kobalt uses 6 series cells and calls it 24v. The Ryobi and Greenworks and Kobalt 40v outdoor power tools use 10 series cells. Ego 56v is 14 cells. Etc.
It's all pretty lose, because it is just chemical reactions (batteries) and big mechanical equipment (grid power production). This means anything critical needs to have a voltage regulator and filtering to give it a precise and stable voltage. Your USB "charger" is actually a power adaptor and regulator producing the correct voltage(s) and power levels defined by the USB standard (5v +/- 5% at 0.5a was the original, 1.0a and up to 2.0a are common with the device taking what it needs up to those levels, and it only gets more complicated from there with Quick Charge and USB-C Power Delivery (PD)).
Are the wires copper a lot of aluminum being substituted which means you need thicker wires.
Aluminum doesn't necessarily mean it is bad as long as it can carry the current capacity stated and remain under the design temperature in the worst case scenario. So if they use aluminum, yes, they have to use thicker wires to make up for not being copper to meet the same specifications.
Btw, the wires are copper.
So let me ask the question here if you have a 12 volt battery at 100 amp hour is that the same as a 48 volt 25 amp hour battery and vice versa if you have a 48 volt 100 amp hour battery that's the same as having a 12 volt battery with 400 amp hour. Is that right?
The same in what way? A lot of things change. But the capacity is the same so yes you are right in this regard.
Wow, how much was it, 50 something watts for the inverter? That's a lot. Is that a fixed value or a percentage of the total load?
50 Watts is fixed when the inverter is on. You can have it power down if it uses less than 50 Watts after a period of time. In order to make it worth while, you'd have to have enough solar to compensate.
Great explanation! Thanks a lot...
What issues can occur if four 12v LFP batteries put in series (making a 48v bank) then connecting the bank to a 48v LFP rack mount battery like the one in the video? I don't believe it is a good idea as BMS conflict may occur or is this possible?
You are better off with all your batteries managed by 1 bms if you have a 24 system, you want all the cells per 24v managed by the same bms so it.can keep them all in balance. Stringing together multiple batteries to increase your voltage can be problematic Because you can run into balancing issues purbattery in the series chain. Granted you can put in battery balancers but still that is not really ideal
How long will an 230 V oven heat with that thing? Imagine I use four electrical plates and the oven at 300 degrees
To do that you'll need a 230V capable inverter. This battery can only do 5kW max so you might run one oven and one stove max for 1 hour.
@@BeatTheBush 1 hour does not refer to 5 kW but Ah. I have heard that I couldn't do this directy from solar panels and inverter and there has to be a battery
I may have missed it in your video, but does it have a pre charge resistor? Thank you
To limit the current
Yes, does it have anything to limit current when power is first sent to the inverter to not overload it. If I am saying that right.
There is no mention of one in the manual. I'll check with the manufacturer to see if if I missed it.
cool. thanks for uploading :)
What happens if you touch 100amp 48 volt battery
Does it better for 48 ups
16S FTW!! Cheers!
I find a medical gel pack works better for cold temperature test. 👍
thanks for the idea! i'll try that next time.
Picked up this on Amazon Prime Day with a 15% discount getting it down to $934.98, then an additional 7% discount getting it down to 869.53 pre tax shipped to my door ($941.27 estimated post tax). That's $0.17-$0.18 per Wh!!! Can't beat it. Now if only I could find a way to modify it to add a RJ45 connector.....
@BeatTheBush Is there a way you know of to add a RJ45 unit to the BMS to make it have communications to other devices? I saw an empty connector on the BMS, not sure what that's used for or if that would work? Or maybe one would have to swap utility of the screen to have the cable?
You would be in DIY modding territory here. I would start looking if the BMS has any documentation for interfacing.
Amazon for $1044, just bought one and will get it 5/7/24.
Nice! They updated the breaker, it is DC now.
Wat About SAKO Solar Inverter ( Quality Wise)
Why we stop at 48v nominal? Not just an arbitrary number. Its due to safety classification.
...The white paper compares NEC to ANSI Standards. It sites the following NEC voltage standards:
High Distribution - 1000 to 4160 volts
Medium Distribution - 50 to 1000 volts
Low Distribution - 0 to 49 volts
As you increase the voltage, the danger increases. Death can result if mistakes are made.
I have been running a 120vdc bank since 2008. Not 120 ac but 120dc. 10 x 12v in series or 60 forklift cells.
I am hoping to upgrade to lithium iron say 5 x 24volt in series.
Would it work?
Could I just wire them in series and their individual boards look after themselves.
Would this work OK.
I still use the 2kw inverter and 2 kW controllers installed in 2008.
Probably cannot help you design your whole system from just one comment. You do need to see if the DC output range is compatible with your inverter input. 120VDC is not typical.
@BeatTheBush Back then. There were only 5 of with 120vdc systems.
I believe ,I am now the last one. Everyone has switched to lipo 4 48vdc.
I would like to keep the old Chinese inverter and controllers. They are bullet proof. We also a a 120 vdc wind turbine which uses 2 x 138vdc immersion as dump loads. The PV 5KW approx also goes through the WT dump load relays.
It works very well. I also run my workshop of it. The old iron core. Low frequency 2kw inverter is very dependable and used less on standby.
For bigger power. I use the 120 vdc 4 power module Symettra rm. Or when I am cutting the lawn I boot up an Eason Compac 3 000 again 120vdc 2.7kw.
It would be handy if zi could switch over onto 5 x 200ah x 120vdc lithium iron.
5-24V LiFePO batteries would range in voltage from 100-146V DC. You must make sure the previous system can operate at this range. Lead acid voltage would have went up to only 130V. So your charge controller needs to know how to charge this type of battery.
I just received this same battery from Vatrer. Mine when it hits COV has cell#1 at 3.713V and the rest at 3.4 volts. I contacted Vatrer and they said 300mV difference is normal. Lol, no. Having a cell peak at 3.713V while the rest are at 3.4V is not good. Does your battery do this or are all cells balanced well below 300mV diff when COV MODE cuts charging?
3.65V is the limit so going there is really bad for the cell. If you look at 11:34, the top voltage is 3.624V. The issue is not a 300mV difference but the highest voltage each cell attains.
Perhaps one cell is a little lower in capacity so it charges much faster. You might want to discharge it a little and let the balancing work to equalize the energy. Then recharge it back to 100% to see if it does the same thing.
Thank you for the reply. Yes 3.65V is max and certainly not good to float there, 3.713V like mine even worse, all cells except #1 go no higher than 3.4 to 3.45 but the cell#1 is ovrecharging/peaking at 3.713V then battery bms goes into COV while the other cells sit around 3.35v to 3.4V. I like your pack balance distribution better. Yes, I was going to manually deplete a little off of cell#1 and I suggested me doing just that earlier to Vatrer but they didn't address that. They just had their tech say it is all normal and fine with the one cell peaking at 3.713V while all others are at 3.4V.... but we know better. 😉 I was giving it a few cycles to see if it would balance out on its own, but I think I will go ahead and do a minor manual depletion on cell#1 while I have it apart relocating the bluetooth module to the back of the LCD display so it get get some signal out. First thing I noticed after the cell mismatch was the poor range of Bluetooth. I build my own packs and bought this battery so I would not have to match and manage varying balance of salvaged LFP cells, just to manually balance new grade A eve LFP cells...😂
I live in montana...what good is a 32 degree low temp?
Might want to look into sodium Ion batteries. They're' just starting to be mass produced. They can operate down to 14 F. Of course some Lifepo4 batteries have built in heaters but they cost more.
Does it get that cold indoors?
Pylontech US5000 can we compare it with that battery
Noted for future reviews. That being close to 3x the cost, I was hoping it included active water cooling but it doesn't.
Very nice 👌 👍
If I charge with ups 48v
The problem with 48v is that when you want to step up and increase your storage rating you have to buy 16 cells, 8 cells for 24v and only 4 cells for 12v, I'm with 24v.
Yes, when you have a 48V system, adding to the capacity will require you to add another 5kWh worth which is another $1100-1300 for cheap ones.
You can die from a 48 volt system by touching it wrong. Is dying worth the benefit of a few nickels saved on wire?
I was comparing a 48V system to a 48V system with four 12V batteries. Not a 12V system with 4 batteries in parallel where it's a true 12V system. 100A on the 48V would equate to needing 400A capable wiring for the 12V system. The cost differential is in the hundred or two.
48 volts has been the standard for over 100 years in the telco industry I know of no deaths from it worked with it for over 30 years. You save dollars not nickels when you have systems that are in thousands of watts copper is expensive and batteries last longer by drawing smaller currents.
I need it
Hey BTB, I just sent you an email. Thanks for your very infomative videos, this is a game changer.
FYI I do not do consultations for building systems.
I think it's better to buy lower voltage batteries, which are more standardized and cheaper due to mass production, and simply connect them in series.
Well I guess I have to take back what I said about cheaper. I don't know what's happened to the prices but they're mental now.
You would have to get a battery balancer to keep the cells balanced which adds to the cost.
@@BeatTheBushwhy bms of individual battery don't work when we connect 4 batteries in series?
Wow they're using AC rated isolation switches to try and switch High current DC voltage - not good!
Thanks for pointing this out. To me, this is a very serious issue and will pull the purchase link from the video description for now. I will suggest the manufacturer update this to a DC breaker, possibly have them send me a retrofit one and update the product if possible.
Went to a solar expo they had 100 volt inverters and batteries….
Yep, Double the 48V, pretty dangerous at 100V though.
@@BeatTheBush I know but Huawei inverters has some models which area battery ready and they accept only Huawei batteries. I read somewhere they are high voltage batteries.
Don't want a 200ah one? I'm looking at one now. It's only 189lbs. No problem for me.
A monster fo a battery!
Yes it is! I just noticed that battery doesn't have communication ports on it. Is that or the touchscreen monitor really necessary with the bluetooth that it has installed on the BMS.? How well of a bluetooth signal do you get with that metal case? Thank you for this video and response to my questions.Much appreciated..@@BeatTheBush
chassis ground.
First 2 minutes, info : OK. Newtons' Laws state '' energy is not lost - only transformed ''. There is a mid-point, between WIRE size/insulation properties , due to Physics Laws. ONE, must choose, WHAT voltage is needed, for the (your ! ) Applications. For most, 48 volts is fine ; 4800 watts. That, would power heaters, small stove, and most AC units, as well as any fridge, washing machine, small electric dryers, probably All lights. The Balance, point, of Cost /versus Needs , must be CHOSEN WISELY. Always, All Ways,....leave your options, OPEN, for expansion; over time hi-tech will modify, slightly, ACCORDING TO THE ABOVE LAWS, OF PHYSICS / ELECTRONICS /ELECTRONS.....and wires !
Math is math....
Batteries dont make more power because you go from 12v to 24v.
2 - 12v , 100ah batteries = 2400 watts regardless of whether in series or parallel.
All things equal, going form 12V to 24V reduces power loss in the cable by about 30% so you can use thinner cables.
people with 4 12v inverters could connect their inverters in series to a 48v battery 😜, joking don't do this. It's good to check, check, check, check & check again when connecting the bus bars.
I had a brain fart and had 2 cells shorted and scared the crap out of me, im lucky the aluminum bus bar didn't weld itself.
yeah and WHY is a 48 volt system better? lots of talk just not about your title.
The whole video explains the advantages.
Smaller cables, cheaper cables with the same wattage output. But I go over this in detail in the video.
A sales pitch
Im out not even going ti bother watching
I have an issue with the video. You state about the higher the voltage the more dangerous it is. Then you take apart the battery connections without protective gloves. Then you comment that you're an engineer and how its a 100a system. Basically what I'm getting at is you're setting a bad example by not using protective gloves. The first thing you are taught about working with electricity is safety. Kids watch your videos. Set the proper example not just by talking of the dangers but showing how to do things in a safe manner.
Human skin conductivity is low enough it’s fine. For him to touch the connections when current is not running its safe. What’s important is to avoid dropping an uninsulated tool across positive and negative terminals. If you let your kids near this that’s adult supervision negligence.
@@rabbitpumpkin8279 so now blame the parents. I think we are all parents. As such we all help as a collective. I will defend a child from a danger. Even if I'm a complete stranger to that child. Not just children though, I've done alot in my lifetime to protect life and property. I don't want to do something that could harm anyone. I would hope that the op would think the same. Besides if the op was to find himself looking for a job this vid could be bad. Many employers do deep background checks on job candidates. If an employer was to view this vid and note the same thing that I saw this could be used against hiring the op.
Diy! Diy! U should know better never to do this at home.
boring video
Say what? I enjoyed it greatly
That was a great video! I've never seen the 100Ah EVE cells before, got 16 of the 280Ah ones recently. Was glad to see him take the pack apart and seeing the smaller ones here!
Other channels do not explain low temp protection as well so I learned a lot.