Adjusting Grundfos MQ 45 pump

Поделиться
HTML-код
  • Опубликовано: 11 янв 2025

Комментарии • 50

  • @ntme9
    @ntme9 11 месяцев назад

    My Grundfos MQ3-45 240v is still running strong after 9 years. I had an issue where I would hear it power on (humming) but not pump water for a few seconds then kick in and then you could hear it push water. I thought at first it was the pressure switch but after thinking it through realized it was the capacitor. Instead of buying the exact replacement, which was pretty expensive, so instead I purchased one off amazon with the same specs (but different dimensions) a (CBB60 Motor AC 450V 40uF) for 17.99 and let it hang out the side. It worked perfect and starts pushing water immediately now.

  • @jeremiahblair5816
    @jeremiahblair5816 2 года назад +4

    this adjustment is so the pump will turn on sooner as the water pressure drops? Currently the pressure in my water system drops too low before the pump kicks on, I need to pump to cycle earlier , will this adjustment raise the pressure that the system drops to before the pump cycles on (so the pump kicks on sooner)?

  • @markhenshaw2574
    @markhenshaw2574 4 месяца назад

    I just adjusted my pump as in the video. I wanted to lower the total pressure. Here's what happened. I adjusted the switch out 1/2 turn. The "cut in" pressure went to 25 PSI from 50 or so, and the pump cut out pressure stayed the same at 65. I was hoping to reduce the Overall pump pressure.

  • @ethersecure2432
    @ethersecure2432 3 года назад

    And that was the last time anyone ever saw Steve and Bob again...

  • @HPL5P
    @HPL5P 5 лет назад +4

    Why did you make this adjustment?

  • @jerkster9114
    @jerkster9114 6 лет назад +4

    Why didnt the manufacturer give us an adjustment screw outside the pump?

  • @samdaniel5703
    @samdaniel5703 6 месяцев назад

    Do i need to add a regulator and a check valve to this i was thinking about putting a 50-100 gallon tank after my pressure tank so i can run my house on this pump? Will that work? Ive acquired this unit for free. The reason for doing this is so when my water outside my house befor e it enters the house sometimes it pulls all the water and no water in the house and the well pump has to build back up. Hince the 50-100 gallon storage tank with this pump could it work?

  • @andywazy4383
    @andywazy4383 2 года назад +1

    Did he forget to plug the pressure switch back into the mother board?

  • @MrSavage77
    @MrSavage77 5 лет назад

    Thanks for the hint. Still, what are jumpers on the board for?

  • @hugohidalgo5708
    @hugohidalgo5708 2 года назад

    I have question what happened when the pump running every three minutes

  • @gmctech
    @gmctech 5 лет назад +4

    So whats stopping me from driling a god damn hole in the back of the housing so i can do this with it all together and no guess work as the gauge will show me whats what in real time?

    • @moimemesuis
      @moimemesuis 4 года назад

      the rubber cover and that the adjusting screw is under power all the time.

    • @travistaylor509
      @travistaylor509 4 года назад

      Have you had any luck figuring yours out? I just bought a house with one of these (installed 2013) and realized it never kicks on. Gauge pressure before the pump is about 40-45 psi. I am guessing pump inlet pressure never drops low enough. So why is the pump even here, just seems like a restriction. Water pressure is adequate but it's not 65 -70 of my old place (borderline too high per home insp.)

    • @curio124
      @curio124 4 года назад +2

      ​@@moimemesuis this is not correct. I've dismantled whole sensor and it's actually super simple mechanism. If you look at it (for example 3:54) it consists of 2 halves. 1st half is "water" half, it let the water in, but the water is blocked by silicon membrane - so it's closed "cave". 2nd half is "electric" half, but there is actually just 1 stupid microswitch (close/open circuit) without any electricity. Water press on that silicon membrane, that membrane press on a big plastic button and if that big button is pressed enough, it press the microswitch. That screw just increase/decrease a tension on a spring, that press the big button against the water pressure.
      So it's actually a good idea to drill a hole to the housing and remove that rubber plug (-:
      You can easily dismantle whole thing. No worries. There is nothing you can break or crack. My pump had an issue that every 10-15sec of water delivery it turned off for a second. I guess that that spring just lost some strength over the time and it can't hold the pressure of the water anymore. I had to remove the whole sensor like 20x, because the correct spot was in a very tiny area. I've moved it 3 degrees more pump never stop (even without water delivery), I've moved it 3 degrees less and 10-15sec pauses were there again.

  • @SK-wf1oh
    @SK-wf1oh 6 лет назад

    how to set up start pressure? it's possible or it was programmed permanently

  • @pfmcdermott1
    @pfmcdermott1 10 лет назад

    How did this end up working? Does it cycle on and off more, or does it just pump up the small pressure tank that much higher s it cycles on and off the same but just provides more pressure? Thanks for the video! It was great to see this adjustment.

    • @johnpiatek1588
      @johnpiatek1588 10 лет назад +3

      It just changes when the pump kicks on. Doesn't change anything else

    • @hpthynne
      @hpthynne 8 лет назад

      Thanks for the potentially helpful video. Would this adjustment resolve a delayed starting issue with the pump? My pump sometimes takes anywhere from a a few seconds, to a few minutes to start when a tap is opened. It has worked flawlessly since 2008 until now. Thank you.

    • @johnpiatek1588
      @johnpiatek1588 8 лет назад

      It cycles on quicker. Pressure is the same.

    • @johnpiatek1588
      @johnpiatek1588 8 лет назад

      Resolves delayed starting but it's normal for the pump to take a few seconds to kick on. It is activated by pressure drop and/or flow. If there is too much back pressure in the lines (as in the case of larger pipes with long runs) it takes a long time for the pressure to drop to around 25 psi when the pump kicks in. That's where the adjustment really helps.

    • @ntme9
      @ntme9 2 года назад

      @@johnpiatek1588 So this just adjusts the turn on pressure? But you said if you turn it too far it won't cut off. So doesn't that mean this adjusts the turn off pressure?

  • @skipjohnson6881
    @skipjohnson6881 4 года назад +1

    This video does not tell you to relieve the pressure by finding the valve under the round cover in the back. You then have to recharge after adjusting.

    • @ChasingRuben
      @ChasingRuben Год назад

      in what case you have to relieve the pressure of the valve? if you wanna made start the pump with low pressure? mine isturn on when the pressure drops to 35 psi .

  • @SK-wf1oh
    @SK-wf1oh 6 лет назад +1

    in my case I couldn't see any differences after turning 90 degrees

  • @samuelclark7005
    @samuelclark7005 6 лет назад +1

    My pumps starts and pumps fine but every 11 seconds it cycles off and immediately back on...it "pulses" is this what needs adjusted?

    • @stefaangoeman6019
      @stefaangoeman6019 6 лет назад

      I have the same problem, i try to found out what's wrong, i think the pressure switch that is bad

    • @surfgeorge
      @surfgeorge 6 лет назад

      Exact same timing (11 on, 1 off). Anyone got an answer? This is a brand new pump that was stored in the original box in a dry location for a number of years. It's also quite noisy compared to the identical model it replaced.

    • @robertgraefe6205
      @robertgraefe6205 5 лет назад

      Check for a leak somewhere it doesn't take much. Leaky fawcet, leaky toilet or a small leak anywhere.

    • @briankennedy7345
      @briankennedy7345 4 года назад

      surfgeorge did you get to the bottom of this issue? Mine is 11 secs on, 20 off. Curios, thx!

    • @briankennedy7345
      @briankennedy7345 4 года назад

      Stefaan Goeman did to u get to the bottom of this issue? My pump is cycling 11secs on, 20 secs off. Thx!

  • @briankennedy7345
    @briankennedy7345 4 года назад

    Hi all, I tried this on mine, 2 half turns, 1 at a time, however it is still cycling 11secs on, 20 secs off. Could this be a capacitor issue? Thanks for any info, and thanks for the videos!!

    • @AN-ks2ep
      @AN-ks2ep 4 года назад

      no, if capacitor faulty pump will hum and no turn or completely not working

  • @youtucciuniverse6925
    @youtucciuniverse6925 2 года назад

    My pump stays running at 45 psi. The built on pressure tank was full of water. Would this be the cause? And if so, anyone have a grundfos pressure tank they wanna sell for $5 bucks?

  • @perceval7790
    @perceval7790 8 лет назад

    Hi, I wonder if you can tell me how it is possible to connect a water pressure tank to this pump....Should I connect a pressure switch somewhere connected also to the pressure tank??? thaks

    • @johnpiatek1588
      @johnpiatek1588 8 лет назад

      You'll need to write to Grundfos for that

    • @perceval7790
      @perceval7790 8 лет назад

      and they told me to look page 21 of their fucking PDF which said nothing

    • @johnpiatek1588
      @johnpiatek1588 8 лет назад

      It should work with a pressure tank but you would need the owner's manual to see how it's done. Other than that your well guy or plumber should be able to help you out.

    • @robertgraefe6205
      @robertgraefe6205 5 лет назад +1

      BS. Just hook it up on the pressure side of the pump. Grundfos product manual and customer support suck. I have just installed a pressure tank and it eliminates the short cycling. I may increase the low factory pressure setting at a later date.

    • @moimemesuis
      @moimemesuis 4 года назад

      @@robertgraefe6205 Yes, I did replace a normal pump in a hydropneumatic system by this pump, leave the tank installed and works wonderfully.

  • @j1284
    @j1284 2 года назад

    So mine will not turn on when I run my water, unless I run a sink and a shower and something else. I can hear a small rattle when water is flowing through it when the pump is not on. I checked the flow switch and it seems to be free of any debris. Will adjusting the screw help?

  • @ProfessionalsAutoBody
    @ProfessionalsAutoBody 8 лет назад

    My pump turns on but wont shut off, any suggestions?

    • @johnpiatek1588
      @johnpiatek1588 8 лет назад

      You need a service call or write to Grundfos for troubleshooting

  • @SereneVaIIey
    @SereneVaIIey 4 года назад

    Why is it that even if no one uses the faucets the pump automatically turns on evryvtwo minutes??

  • @GTerplan
    @GTerplan 9 лет назад

    I'm not sure if your still monitoring this, but I have the mq35 and it has the same components. I have turned that pressure screw once as in the picture and again the same amount since it didn't change anything the first time and the pump still only kicks on at 30psi. I would like to get this to 40psi if possible.

    • @johnpiatek1588
      @johnpiatek1588 8 лет назад

      Write to Grundfos and find a local service tech

  • @trujillor84
    @trujillor84 4 года назад +1

    When u work with electrical components you have to take off all metal from your body (like that ring 💍)... u know... for safety😁

  • @peterfaulk4630
    @peterfaulk4630 2 года назад

    Don't do this.
    These pumps are designed to not be adjusted for a reason.

  • @juanrividdi7504
    @juanrividdi7504 11 месяцев назад

    hi! My pump turns on but won't turn off, any suggestions?