  • @ericpowell7547
    @ericpowell7547 8 месяцев назад +1

    Thank you Joel, I've watched this video a dozen times, in the last 4yrs. Keeps my boiler purring nicely. This breakdown was the spark plug, there was actually a little burnt spot on the side of porcelain, were it was arcing out on casing. You're always my first goto, clean first, see what's going on. God bless you!

  • @geraldschnur5624
    @geraldschnur5624 6 месяцев назад +1

    great video! i am a hvac tech and have to clean one of these next week and will do what you did in this video!!!

  • @tomlambert1833
    @tomlambert1833 Год назад +1

    THANKYOU for this great video..
    Now i need to do mine..😂

  • @mikesantiago7752
    @mikesantiago7752 3 года назад +1

    Thanks man.....I'm gonna try and clean mine and save a few $$$$$

  • @alphaplumbing567
    @alphaplumbing567 2 года назад

    If your burner looks like that you have a combustion issue for sure. Need combustion analysis. Also should be soaking burner, cleaning exchanger with a SS safe solvent, and replacing that ignitor, FYI.

  • @shazerash872
    @shazerash872 4 года назад

    I have a LB white model TS350
    I can’t seem to get it going. I’m on the reservation and can’t get out to getting fixed.
    Any advice ... blinking 3X and it’s running but no heat. Not sure if it’s calling for gas too.
    Let me know thanks . And your videos are cool

    • @joelwyttenbach2772
      @joelwyttenbach2772  4 года назад

      Shazer Ash First thing does the fan start 2 times. If yes does your hot surface get red?

    • @shazerash872
      @shazerash872 4 года назад

      Not two times . But the fan does come on. And not surface doesn’t turn red

    • @joelwyttenbach2772
      @joelwyttenbach2772  4 года назад +1

      Shazer Ash ok the fan will start and the system will check the air proving switch and fan will shut down. Is this when the light starts flashing 3 times. Or does the fan start up 1 more time before the red light flashes.

    • @darkangel10001000
      @darkangel10001000 2 года назад

      You should read your book that came with the boiler. It should have error codes in it

  • @ericboudreau7458
    @ericboudreau7458 4 года назад +3

    To cleaning stainless steel heat exchanger need warm water and soap. Never use steel brush! The steel bruhs will remove the coating protection Rust will appear in the future. Use only nylon brush . And always do gas pressure &co test after service

  • @shazerash872
    @shazerash872 4 года назад

    Starts up and then shuts off and blinks three times ...
    I cleaned the Orpheus and check my contact and wiring

  • @ConstContact
    @ConstContact 4 года назад

    So you are using a wire brush to clean heat exchanger??

    • @joelwyttenbach2772
      @joelwyttenbach2772  4 года назад +1

      Only if it needs it to keep it smooth and clean I don’t use a stiff brush but a softer wire.