  • @bagnoum747
    @bagnoum747 3 года назад +2

    Interesting class.
    Something about UI / OP, PNS, RSR please when you can.

  • @simplethings9638
    @simplethings9638 2 года назад +1

    Please make video on How to connect PLC to fanuc robot

  • @MrPromerican
    @MrPromerican 3 года назад

    Great content...thank you

  • @kaushlendrasingh5762
    @kaushlendrasingh5762 3 года назад

    Hi, sir
    Srvo 157 occurred.what your analysis, experience about 2000ic

    • @FutureRoboticsChannel
      @FutureRoboticsChannel  3 года назад

      Anything specific happened before the error ?
      Quite few things can cause it: bad cables (from servo to amplifier), bad amplifier, estop board not being ok.
      I would always start with checking the fuses :-) I'm showing most of them at the end of this video:
      ruclips.net/video/vFcrZu5L65U/видео.html

    • @kaushlendrasingh5762
      @kaushlendrasingh5762 3 года назад

      @@FutureRoboticsChannel
      Change the amplifier run the system but what happened no understand?

    • @FutureRoboticsChannel
      @FutureRoboticsChannel  3 года назад

      @@kaushlendrasingh5762 have you changed the amplifier ?
      Maybe that caused it, is the amplifier new or used ?
      Maybe a fuse blew up / tripped after changing it, is the amplifier type correct for sure ?

    • @kaushlendrasingh5762
      @kaushlendrasingh5762 3 года назад

      @@FutureRoboticsChannel check the all fuse ok and change new amplifier run the system

    • @FutureRoboticsChannel
      @FutureRoboticsChannel  3 года назад

      @@kaushlendrasingh5762 now is ok, you now you have the error ?