Optimising MPPT charge controller settings for maximum solar power!
HTML-код
- Опубликовано: 7 окт 2024
- / @amoreinformations
MODEL#
EC MPPT V7
POWER
70 Ampere
Solar System Voltage
12V/24V
PV Operation Voltage
15-100Vdc @12V 34-100Vdc @24V
Max PV open circuit voltage
100V-DC Max
PV input power
12V 1200W / 24V 2400W
Max Charging current
65A Conversion Efficiency 98%
Protection
High voltage and high temperature protection
BATTERY
Lead
Acid
Tubular
AGM
CHARGING VOLTAGE 3 STAGE
Bulk
Float
Trickle/Equalize
CHARGE VOLTAGE
14.7v
Output volt without Battery
12V System= 14.2V 24V System= 29V
Voltage can be set according to different battery Manually
COOLING FAN
THERMALLY CONTROLLED
#solar
#system
Highlights
Digital display & Led battery Level indicator
96% efficiency in 12-V systems and 97% efficiency in 24-v systems
Wide input voltage range: 15 V to 100 V
High rated output current: 70A
Over-charge and surge protections
Pak Tech MPPT Solar Charge Controller 70A
Smart Digital DC 12V/24V System
Over-temperature and ambient light detection capabilities
Antidusk kit(Optional) for filter Air
#amoreinformations
#kmyoutube #mrbeast #tamoorfan
#uelectric #youtube #technology #a2zsolar #aajtvofficial #hackerom #ajelectric #professional #theexpertssolution
#efficientcharging#energyoptimization#mpptsolarchargecontrollersetting#mpptsolarchargecontrollersetupsinhala#mpptsolarchargecontrollersetuptagalog#mpptsolarchargecontrollersetupwithups#upsintegrationPak tech mppt charge controllermasjid solar panelmasjid solar systemmppt solar charge controllermppt technologypower managementsinhala guidesolar charge controller reviewups integrationwhat is mppt
mppt explainedmppt solar charge controller setuppwm solar charge controller
force mppt charge controllermppt pricesimtek mpptsimtek mppt solar charge controllerpwm vs mpptsimtek battery chargersimtek charge controllerhybrid mppthybrid mppt solar charge controllersimtek hybrid mppt
mppt solar charge controller price in pakistan simtek 80a
simtek mppt new modelsimtek 60a
sinko mppt #youtube
how to increase solar panel amps
ceiling fan ampere
solar panel wattage explained
how many kw solar panel do i need
fan electricity consumption
ceiling fan power consumption
Bhai jub Battery full ho jay tu kia krin
Blast tu ni hu ga
Jub Battery full ho jay gi light on ho gi tu kia krna ho.. please reply
Asslaam o alaikum
Sir mere pas Faisal mppt lga hua hy
Us ka masla ye hy k raat ko solar mein battery ka current ja rha hota hy matlab k us mein reverse protection ni hy raat k wqt panels mein battery ka current majoot rehta hy
plz ap is pak tech ko chek kr k btain keh jab raat ho jati hy to us wqt solar ki trf current bnd hota hy ya ni
Nahe bahe Pak Tech ma asa nahe hai Aur jitna bi MPPT ya simple charger controller hota hai un ma current solar panel ki taraf nahe Ka sakta ap na kasa check Kiya ap ki battery ki power solar ma hai ?
@@amoreinformations 1 din upr chat pr main solar k connection khole hue to wire apas mein lg gai jis ki wja se mujhe pata lga phir main ne raat ko chek kia
Nahe nahe bahe is Ka ya MATLAB nahe ap Ka MPPT reverse current karta hai solar ki wire nicha MPPT Ka sath connect Hoti hai hai jis ki waja SA spark howa lakin kiyal rahkna Dubara asa na ho warna MPPT damage bi ho sakta hai ap Acha Kara Tu Jo wire solar SA nicha MPPT KO arahe hai uss ma ak breaker laga dan rat KO wo breaker off Kar diya Kara pir solar ki wire jab ap open Kara ga Tu apas ma mil Kar wo spark nahe Kara ki aur don Ka time per bi Kar sakta hai
Possible howa Tu ma is per ak video bi bana du ga ok
@@amoreinformations g sir zarur is pr video bna dho choti c ab to Maine ab bareaker lgy hue hain.
Jab solar disconnect ho gy to phir un wirs mein current ni jana chahye jab controller lga hua ho to controller lgya hi es liye jata hy keh pro protection ho ache se
Is ki setting main P5 kis liey hoti hy
Really informative
App k cut off volt kitnay ha
Bhai battery full ho jay tu kia krin
Kya price he
mppt acha kon sa ha
Controller price Kitny ka mila
9000 in Pakistan
150 watt k 4 panel kesy lagane hen parallel men ya series men?
Ya phr 2 2 ko series men bana k phr dono strings ko parallel men?
Plz reply zrur kejiyega!
Ap MPPT ma lagana chata hai ya simple charger controller ma
@@amoreinformations PakTech Mppt controller men brother?
Aur mery ps total 5 panel hen 150 watt k
Bro ap na amp zada Lana hai Tu parallel connection Kar la ya watt zada Lana hai Tu series ma connection Kar la
Mana apna liya parallel connection Kiya hai mara pass 180 watt ki 3 plates hai parallel ma 19 to 25 amp mill Jata hai
@@amoreinformations brother mery ps battery ha Osaka tubular TA-1800
Konsa behtar rahega ap plz suggest krden!
MPPT jab pr jab load dala jata ha aur es k solar ampre meter pr 35+ hote hain toh jalne k smell kyon ati ha but jalta nai ha kuch.
Main us waqat 12 chotay bare led lights , 2 fan , 1 Toyo cooler aur aik modem chal raha hota hon. mere pas 1000 watt ka ups ha us pr Load 60-65% hota ha....
Aj ups sy bhi thori jalne ki smell aa rahi thi. ye kya problem ho sakti ha ?
Ap Ka MPPT hybrid hai ya nonhybrid
@@amoreinformations Hybrid. smell was caused by battery cable to ups.. able itni heat-up hoi k ups ki port almost melt ho gaien
@@ShahabHaider-w5p wire kitna mm ki hai ap ki jo battery and load ka liya used kar raha hai ap
Kitny watt ki plates lgai hen?? Or kitni?
Mana 180wats ki 3 plate lage hai ap 585 wats ki laga sakti hu
Sir mari pas 585w 1 palt h aur 2 fan Khurshid ke Sara Din chala aur tr 1500 145 ah exide battery charger ho jayegi aur cat off voltage kya rakhu
Ap Ka pass kon SA controller hai
Pak tech
@@mianadeel-ep9cb bahe ak plate SA cha ho 180 watt ki ho ya 585 watt ki wo sir 7sa 9 amp hi banayi hai ap na MPPT lagaya howa hai Tu wo Kar la ga charge but ap is Ka sath ak plate aur laga Dan Tu batar hu ga 180 watt ki bi laga Dan koi masala nahe ap Ka amp zada ho jaha ga ap KO volt Ki zaroot nahe amp ki zaroot Hoti hai
14.7
Merzy pass ha par es ka hybird mode work nhi karta mujy wapda on off karna parta ha
Is par dc load katnee amp chala saktee hain
50 to 60 amp tak lakin kabi itna load chalya nahe q Ka DC Ka load Kam hota hai zada SA zada 25 SA 30 amp tak he chalya hai
Paktech mppt charge controller me Pehle solar wire lagayinge battery cut up voltage k liye ❤
Paktech ma battery cut up nahe hai and sub sa pala battery wire lagaha pir solar and pir load
Ye jab battery ko full charge Karta he tu ye battery ko cut up nahi karta ..
Paktech mppt me Jo variable screw hota he y kisliye hota he
@MuhammadDawood-fj9ug karta hai lakin jab battery used hoti hai tu battery low hona per cutoff nahe karta
Mppt ke price keya hy??
Depends karta hai ap KO Kitna load Ka liya chiya ma 70 amp lagaya hai non hybrid 8000 SA 9000 Pak rupees ma mill Jata hai Aur hybrid 9 SA 10 tak aur 70 amp SA Kam wala bi mil Jata hai un ki price bi Kam Hoti hai
Jazakallah
Sir mppt lagaya us k sath single battery 575w double glass pannel 24 may show kar 12 may nahi
Bahe jo 575 w panal hota hai wo 24 watt ka hota hai
@@amoreinformationslol he said volt not watt dumb
آپ کہاں سے ہو اپنے ۔۔۔
Sir 12v or 26v ki setting ni ho rhi.. button idhr ya udhr kro same reading he ati ha
Solar ki cables disconnect kar do aur battery ki bhi cables disconnect kar do pir 12volt per set Kar Ka battery connect Kar lo PIR solar Tu set ho jaha ga 😊
Solar ki cables disconnect kar do aur battery ki bhi cables disconnect kar do pir 12volt per set Kar Ka battery connect Kar lo PIR solar Tu set ho jaha ga 😊
Mere pass bai masala yi hai ki yi controller mere single 12v battery ko full hone tak 70 amp se charge kr raha hota hai to istara meri battery damage hojaegi
Meri battery phoenix tubular tx 2500 230ah hai jis kiliye charging current 30 amphere se zyada nahi hona chahia
Ab aap btai current ko kaise control kare
Is ka ander sa setting hoti la acha kara tu market sa kara la wo batar ho ga
Sir same hum ne lagaya huwa hai but wo battery ko heat karta hai aor cut off nahi karta
Ap Pala apni battery check karra muja Lagta hai us Ka koi cell short hai and check Karna Ka bad muja zarro batahan
Board se is ke setting ho ge phir ye cut off kry ga
Board SA ho jati hai but bro battery check Kara lo mara bi ya issue Aya tha is liya ap KO bataya
@@amoreinformations koe bhe CHOTI battery lga kr ghr pr check kr skty hn k trip kr rha hae ya nahe?
@@junaidshah6566 han bilkul
where to buy online
Daraz sa mil jaha ga per tora expensive para ga
Mery paktech mppt men solar Ampere show nhi ho rhy?
Bahe jab 8 ya 9 amp ho ga to show ho ga mana video ma ap KO bataya hai 8 SA Kam amp solar SA aha Tu wo show nahe hota
Ap video pori dhak la Tu ap KO samja ajaha ga pir bi koi questions ho Tu pouch sakta hai
Bhai ma 12 volt pa setting krta hu to phir b jb amo show hoty to wo 50 60 tk Chaly jaty phir 1 dum zero ho jaty
aamir.sohail4040@gmail.com kindly video send Kar dan is Gmail per ya picture connection ki
Same problem
Panel kese lgy gy 300watt wly
Ap na kai used karna hai pala ya bataha aur ap ka pass kitna panal hai
@@amoreinformations 300watt k 3 panel lagany hy or dc per chalana hy fan & lights
585 watt jinko N type k 2 solar panel lagaiye hai with desi ups aur 1800 phoenix ki 1 Tabular Battery, non hybrid mppt controller paktech k sath es ka button 12 volt rakna hai na aur agar din mein refrigerator chalana ho tu us ka bi bta de
Bhai behtar ye hay ape 3KV Ka Acha inverter le ...agar frig Chalana hay to
Baki ape ke setting saii hy solar se battery setting Ki
Ups per direct refrigerator na chalahai ap ki battery ma masala jaha ga
Sai agar ek panel aur laga lo and suoer 1500 W Battery inverter k sath refrigerator chalao tu
@@shehrozekhan7969 minimum 2kv Hona chiya bahe
Battery volt 16.6 athy hai aur Solar mode wali light bi ab ni chaltii es kia kiya issue hai
Dc load kitna tak chala sakta hai
Bahe ap Ka solar per depend karta hai
Koi btyga agar dc system lagai to dc supply cut off krta hai??
Ya ap ki supply per depend karta hai Ka uss ma cut off auto hai ya nahe
Ups kesy lgy ga
insha'Allah next video ma upload karo ga is bara ma
@@amoreinformations abie zrort hau please bta day
@@amoreinformations mujy apna number day may call krta hon please
@@arslangaming5324 ap kai din ko he used karna chata hai kai
@@amoreinformations rat ko b
Good information 😅 and thumbnail
Thanks
Bhi jan 3 plate 585 wats ke 2 batries 100 A ke aur 70A paak teach ka mppt controller he to connection kese kry
Kai ap na DC load chalana hai
Parallel man
Bhai in bhootni walon k charging amp kesy control karen jo btany ki baat ha wo koi ni bta raha
Solar sy 3.17 or MPPT sy 1.31 sy battery charge 😢 bhai gi phr MPPT ka kya fayda . time pas video .
Nahe ap na Mari bat pori nahe Sunni first Mari battery already 90+ ti and ya morning time ki video ti and and MPPT ap ki battery Ka mutabik Kam karta hai hai jis ki waja SA ap ki battery damage nahe Hoti insha'Allah next video ma aur clear Kar Ka samjahu ga
Bhai mera message gaur se parho aur plz rehnmai kare mere paas same controller he aur 3 plates he 150+150+160
100ampare ki battery jiski health kaafi weak he yaan usme voltage 10 he
To mujhe kya karna chaiye mere paas ek dc fridge he jo 10 dc ampare leta he jo me ek china inverter par chalata hon
Mujhe kya setting karni chaiye kya connection karna chaiye mppt aaj le aya hon abhe koi setting nai kee he kal karne ki soch raha hon
Bahe ap ki plates 250 sa zada wali hoti mean 350 ya 550 tu ap series connection kar lete lekin aapki 150 ki plate hai to aap parallel connection hi kar le main aapko video ka link bhi share kar deta hun kyu ka parallel connection jyada ampere banate hain. ruclips.net/video/dLOVCeiY9u0/видео.html
Pir bi kuch samja na aha tu apna number share kar dai ma call kar lu ga ok brother
Bhai ye kon sa size ka frige he kiny ky kilta h
@@adnanaslam2798 normal cock wala jo peti wala hota he
Janab mera masla hal hogaya he thanks
battery 12.5 py hote ha koi load nahi dalte phr bhi khud hi 12 py aa jate
Brother Kai battery 12 sa nicha jati hai bina istamal ka aur battery kitni old hai
12 tak aa jati hai new battery hai 2 month hwy , pehly mppt 20,25 amp pr charge karta tha ab 8,9 py kr raha bss kia waja ho sakti gravity bhi check krwye
@@HamzaAli-sz5bu bahe koi masla nahe hai battery tick hai ap ki 12 sa nicha nahe jati tu pir tick hai 12. Sa uper ka point ki koi value nahe rahe bat charging ki wo bi tick hai ya aj battery zada empty ho jaha gi tu zada amp sa charge ho gi jab 11.6 ya 11.5 tak ho gi tu 8 sa 9 amp ma he charge ho gi
Thek ho gaya Bhai shukriya aor Battery ko discharge kitne volt tak kr sakte 120 amp battery hai ??
بھای جان دو سولر پیلٹ لگی ے اور بیڑی مل نہی ھوتی
یہ سولر ایمپر 3.5بتا راہ اور بیڑی وولٹ 13.0 بتاتا بیڑی فل نہی کرتا
Battery full 14.3 ya 14.4 tak Hoti hai bahe
Mary pass ly ayo SAHIWAL kr do ga theek mara b yeh he problem tha cut off volt 13.4 thy
Mera paktech har 10 mint baad off ho k on hojata hai jab load 20 ampair se uper jayn to ampair meter off hojata hai kisi electrician ko samajh ni i
Ap load battery sa liya hai ya controllers sa
Main ne uske sath ups lgaya hai direct battery ni hai
Battery k sath b yei masla hai
@@faisalshahzad2697 ap ac load chala raha hu ya dc
Aur is mppt ki load ic check kar wala is ma masla ho ga
price ?
whatsapp ?
In Pakistan 8500 to 9500 tak mil Jata hai
Bakwas mppt hy.apna paisa waste na krn.kisi or company ka ly ln mgr ye bilkul na lain
😂ya kam nie kr rha sie thra sa.
Ma samja nahe
Ap KO Kai masala aRaha hai
اپ کا رابطہ نمبر مل سکتا ے مشورہ کےلیے
Bahe ya apna number bata Dan ma call Kar lu ga ya mara email per apna number send Kar dai WhatsApp wala aamir.sohail4040@gmail.com
Assalamualaikum bhai apna cell number bata dain
Nahe ap apna number send Kar Dan ma call Kar lu ga
Bhai y Pak tech mppt cantollar nonhydrid battery ko our charge kar rha he tubular tx 1800 battery volts 16.17 pe ja rhe he battery heat ho jaty he or cutoff Nhn ho rha 😧😧
please contact number send
Ap muja apna number share Kar do ma ap SA contact Kar Lata hu
I have also cutoff issue.14.2 py cutoff set kia hy.magr cut nhi krta 15 tk chla jata hy phr khud hi off krna parta hy.iska koi solution hy?@@amoreinformations
mppt acha kon sa ha
یہ سولر ایمپر 3.5بتا راہ اور بیڑی وولٹ 13.0 بتاتا بیڑی فل نہی کرتا
یہ سولر ایمپر 3.5بتا راہ اور بیڑی وولٹ 13.0 بتاتا بیڑی فل نہی کرتا
یہ سولر ایمپر 3.5بتا راہ اور بیڑی وولٹ 13.0 بتاتا بیڑی فل نہی کرتا
13.0 SA upper Jata hai ya nahe