  • @darylephillips6778
    @darylephillips6778 2 года назад +1

    Thankyou for your video i had just bought the relay but it came with no instructions but after seeing you video it has made the operation so easy Thankyou

  • @7x779
    @7x779 6 лет назад +19

    For those looking for infinite ON-OFF-ON-OFF cycle without needing a trigger signal, look at 11:48 for program number 3. NOTE: 1. When your are setting the time in program 3, if you set the time "OFF' first (by setting the time while it's in off mode), then, it will also START in the 'off' mode every time you power it up. 2. If you set the "ON" time FIRST, then (by setting the time while it's in "ON" mode), then, it will always start in "ON" mode every time you power it up.

    • @thanujaperera9903
      @thanujaperera9903 6 лет назад +2

      Pressing K1 in P-3 mode will change "OFF' first or "ON" first every time you power it up.

    • @robojax
      @robojax  6 лет назад +2

      Yes you can program it.

    • @ArmstrongArcade
      @ArmstrongArcade 5 лет назад +2

      What if I'm looking for an infinite ON-OFF-ON-OFF loop with a trigger signal?

    • @TheFalconJetDriver
      @TheFalconJetDriver 5 лет назад +3

      Adam Armstrong it will work pay attention to the video again.

    • @TheFalconJetDriver
      @TheFalconJetDriver 5 лет назад

      Steven Lee dude it does not matter how many light bulbs you use as long as the total amperage does not exceed 10 amps. If it does use a solid state relay triggered by this module.

  • @sandeshgiri9895
    @sandeshgiri9895 4 года назад +1

    Nice explanation. I had procured this PCB board it's cheap and best for delay timer automation.
    For more durability of pcb you can give input power and trigger signal both in 5 vdc instead of giving 12 vdc. Reason is there is no heatsink attached with voltage regulator ic which is converting 12 v into 5 v. If we apply 12 v input then excess heat will damage the voltage regulator IC. Input Upto 6 v 0.5A max will increase the durability and stability of this board even if it is used for continuous operations 24x7.
    Relay build quality is very nice it can withstand more than in household voltage and current ratings. No issue in operating heavy loads through relay.
    One good protection is provided through opto couplers ics for reverse bias protection and reverse current flow protection. Overall I can say it's a industrial standard design.

    • @robojax
      @robojax  4 года назад

      Thank you for comment and very useful information.

  • @codyrussell2999
    @codyrussell2999 3 года назад +1

    Thank you when I ordered this same product it only gave me a diagram for using the same battery for the timer and a device which is not what I need and it wasn't working. Im doing the same thing only with a fan, your advice made it work perfectly!

  • @gem22ful
    @gem22ful Год назад

    This helped me a lot. Thank you. Have a different timer module. 4 digits. 12vdc input without trigger and NCNOCom out. Same functionality. Searched everywhere on how to change the timing range. Glad I saw this video. 😍

  • @yevgeniyatunitskiy8459
    @yevgeniyatunitskiy8459 2 года назад +2

    This is exactly what I looking for. Thank you very much. Now I need to start wiring. Yevgeniya

  • @KAVIAN_HZ
    @KAVIAN_HZ 10 месяцев назад +1

    thanks is this any way to disable the delay time I just want to use once per use I want to use the timer for turning on and not using the cycle?

  • @Louis.P1314
    @Louis.P1314 3 года назад +1

    Very details explaining for this product.. now I'm understanding how its work.. thank you

  • @richlawrence4160
    @richlawrence4160 Месяц назад

    Brilliant explanation. Without your help would never have understood the detailed instructions as translated. I am using it in P6 to power a DPDT relay to reverse current for a model tram shuttle (auto back and forth). In test with LEDS (in parallel with reverse polarity) it flips/reverses current well to the exact time. However, the screen goes blank after the first switch, while the current reversal and timer continue to work. Disconnect the DPDT then apply power and the display works fine. I have tried diodes, separate power supply etc., but it seems to not like the surge required to start the DPDT coil or the surge when DPDT coil power is cut.

  • @TheFalconJetDriver
    @TheFalconJetDriver 5 лет назад +4

    Outstanding explanation of the abilities and practical uses, thank you so much for taking the time to share your knowledge of this device.
    I will be using this to control my dust collection system in my wood shop. I will use P-4 to be a delay to run my blower motor off after a few seconds after I have turned off the tool that started the DC system. This module will turn on a solid state relay since my DC system draws more that 10 amps.
    As for the trigger part of the project I will use a current tap to trigger this module.

    • @robojax
      @robojax  5 лет назад +2

      You are welcome. I am pleased that you found it useful.

    • @eithan20
      @eithan20 5 лет назад +1

      @@robojax I second his words. Thank you very much!

  • @123kareems
    @123kareems 4 года назад +1

    Thank you so much, it would have take me long time to figure out the programming part. You made it so easy. Really appreciate.

    • @robojax
      @robojax  4 года назад +1

      You are welcome. I am glad I it helped.

  • @chinchillaturtle7121
    @chinchillaturtle7121 2 года назад +1

    I ended up using one of these and it triggers but the dc motor im connecting on the right side doesn't spin at all. What I have going on is a 9v battery connected into a bread board then a wire coming from the power of the 9v on the bread board to the top left and a wire connected to the ground of the 9v on the battery going to the bottom left and a wire in the middle left that triggers from a signal from a push button to the middle left. (signal works because countdown enables on this module when the button is pressed) and on the right side i've tried 1 wire in the breadboard ground from the 9v from the dc motor and the other wire of the dc motor in the middle right or even top right of the module with a power wire coming from the 9v on the breadboard on the bottom right but it doesn't ever trigger the dc motor like it's not getting any power. I've tried taking the wire from the bottom right and touching the middle right where the wire from the dc motor is connected and it does not trigger. Anyone have any thoughts on this? Thanks!

  • @Later2u
    @Later2u Год назад

    Great tutorial. I'm going to use this for a delay power off of my car stereo, which is older and doesn't have the delayed time off found in newer cars.
    P-2 program seems to be the one to use, just set the off trigger to zero and the time I want delayed to whatever I want. Thanks again.

    • @mikescotese620
      @mikescotese620 Год назад

      Did you get this to work for a radio turn off delay? I don't see a program that will do this????

    • @Later2u
      @Later2u Год назад

      @@mikescotese620 Yes, I got it to work. What I did was put a fuse block that I could connect everything aftermarket behind the dash I had power to it. You may just have a radio, I have a few other things. I ran power directly to the battery via a relay. This device controls the relay. It works great, but now my radio is powered for however many seconds I've programmed it for, which is fine if your in the vehicle for ~5 mins. But if you just get out, radio is still running until the timer stops. Now I need to put another relay, smaller one, to have the door opening, dome light comes on, to stop power to this timer and shut down the radio. I'm going to do the second relay soon and then everything should work as I first envisioned it. A few hoops to jump through, but doable. The program I used, I think, is the one where there is a delay start. Timer off for a period of time, I have it at zero seconds, and then the powered on for however long you want it on. Hope this helps.

    • @mikescotese620
      @mikescotese620 Год назад

      Many thanks for the reply. I finally got it figured out. For radio delay turn off just use P4. Works great on the bench now just need to transfer it to my Jeep. Thanks again!

  • @kandiaswardhana9076
    @kandiaswardhana9076 4 года назад +1

    can i ask, what are those red, green, and white wires and where are they connect to?

    • @robojax
      @robojax  4 года назад

      you made me watch the video to check if I forgot to explain it. But indeed I have explained it in the video very clearly. Please watch it without skipping. I have not said anything extra on this video.This is the best tutorial ever. If you want to learn about this module, you MUST watch it fully.

  • @ChopperCharles
    @ChopperCharles 11 месяцев назад

    In P2 mode, can I tie the trigger and input voltage together? Meaning, I want the relay to trigger say 2 seconds after the unit is powered on.

  • @michaeldaly3166
    @michaeldaly3166 3 года назад +1

    P-2 seems to work differently for the 4 digit unit
    ie P-2 can be used to close a circuit for a specified time immediately after powering up this handy little unit

  • @AztecWarrior69_69
    @AztecWarrior69_69 Год назад

    But what happens when the module gets power? Does it do whatever function it is set to, or does it HAVE to be triggered? I need a module that when power is applied it turns on for a few seconds the turns off.

  • @toysforboysrc
    @toysforboysrc Год назад

    I need a mini unit that can turn
    off/on on a 0.5 second loop while the signal is closed. Maybe faster., is this unit much capable with a 1.5 amp load?

  • @lordnak2470
    @lordnak2470 5 лет назад +1

    i have downloaded many of your videos so i can watch while offline

  • @charlesdean9178
    @charlesdean9178 5 лет назад

    Oh thanks a lot! Your video saves me some time figuring this out because this module did not came with instruction manual when i bought it from China.

    • @robojax
      @robojax  5 лет назад +1

      You are welcome. Please share this video.

  • @coolasad2k
    @coolasad2k Год назад

    Quick Question. I need to use P2.
    Can the the unit receiving power be the trigger (there is no separate trigger).
    I am using it in a car. so when the car is turned on that is the time the timer receives the power and i want that to be the trigger as will for P2.

  • @magicscorner
    @magicscorner 3 года назад

    12V module currents in all P1 to P4 modes:
    13mA when idling (LED showing time)
    45mA when relay is on (LED showing)

  • @dineshgoyal7695
    @dineshgoyal7695 25 дней назад

    I want just to add a delay of 3 mins when the module is powered on. Means say after a power cut, the power restores, I want the delay of 3 mins then power on the device connected to relay. Can you let me know the connections and mode to use? I think I dont need any trigger for this.

  • @1991Palash
    @1991Palash 10 месяцев назад

    If I want to use this circuit to rotate motor in clockwise and anticlockwise direction by up and down switch with single circuit than is it possible? If yes than how?

  • @ls2011schorsch
    @ls2011schorsch 4 года назад +1

    Is there any version of the same board as a unit that you can mount into a surface plate ?

    • @robojax
      @robojax  4 года назад

      there are 100s on AliExpress and eBay and most don't have a model number.

    • @ls2011schorsch
      @ls2011schorsch 4 года назад

      @@robojax but thats not the same module? www.amazon.de/BIlinli-Timing-Verz%C3%B6gerungsrelais-Modul-Zyklus-Timer-Digital-LED-Doppelanzeige-0-999-Minuten/dp/B07P8RB5KZ/ref=pd_sbs_60_10?_encoding=UTF8&pd_rd_i=B07P8RB5KZ&pd_rd_r=e1898546-5b73-4833-a604-88021dc13f3a&pd_rd_w=kp1PA&pd_rd_wg=DhjLf&pf_rd_p=42bf0ad8-ce6f-4127-a2f0-106727020a41&pf_rd_r=YHXV07ND423QH2FJAYXZ&psc=1&refRID=YHXV07ND423QH2FJAYXZ

  • @omairbinenam6337
    @omairbinenam6337 3 года назад

    I want to turn the device on for 30 seconds without the trigger bypassing this timer and after the 30 seconds have gone it should shut off the device. Then if there is no trigger, then turn it back on immediately and run 30 seconds timer as before, however, if the trigger existed after 30 seconds then keep the device off until the trigger ceases to exist. Is it possible? Thanks.

  • @Darkvoidproductions1
    @Darkvoidproductions1 3 года назад

    so I have 2 timers and one if I hit the signal while its counting down it will cancel the timer but the 2nd one I have will just restart the timer vs canceling it, how do I make it cancel the timer like the 1st one?

  • @waqiuddinshish7127
    @waqiuddinshish7127 Год назад

    Hey, I would to ask if this module can set the time in hour as I want to use it on led light.

  • @andrew39454
    @andrew39454 5 месяцев назад

    Can you explain more on P.2. What if never remove the trigger at P.2. How is it going to perform? delay switch on as normal, after switch on the timer stop counting to turn off until trigger remove? Because i wan to use it at amplifier as delay switch on and delay switch off with trigger.

    • @robojax
      @robojax  5 месяцев назад

      to my best knowledge, I have explained all features. review all modes and find out whichever works best for you use it.

    • @andrew39454
      @andrew39454 5 месяцев назад

      @@robojax Thanks first, what I mean is at 10.03 after you touch the trigger you straight away remove the trigger as shown, what I want to know is if the trigger havn't remove until switch on, what will happen to the device.

  • @tjtravelsandadventures
    @tjtravelsandadventures 5 лет назад +2

    Exactly what I was looking for. Thank you so much for the very detailed description that made my decision on buying a few for my projects.

    • @robojax
      @robojax  5 лет назад

      You are welcome. I am glad you found it useful.

  • @Discover-bd
    @Discover-bd 6 лет назад +1

    Thanks for your nice video, i use this timer but found one problem, i use it as delay power on for my refrigerator ( 220 volt ,400 Watt) use delay for 300 second, which is work properly but when power goes and resume then the load flash for a second i mean relay on for a second then off and count down begin, how can i avoid it. I use here in P-1 mode my adapter is 12 volt DC, trigger pin connected to + DC terminal.

    • @robojax
      @robojax  6 лет назад

      You are welcome.
      when you say "power goes and resumes" is it unexpected "goes and resumes" ? if so this device doesn't have another timer to do this. If this power disruption is due to power blackout , then you have to have another relay module between this and your fridge to prevent it it from doing this.

    • @Discover-bd
      @Discover-bd 6 лет назад

      Thanks for your update, I'm also thinking to add another Relay module, sometimes in my place when weather is too bad, then power ups and down frequently, so i need a delay for safe my electrical gadget , primarily its working fine.

  • @panostsailas4981
    @panostsailas4981 Год назад

    Hello I bought one off these but in p_4 the relay is open and when the trigger is applied the countdown starts and turns off. If the trigger is removed it turns on again. Can you explain that?

  • @Rajsweety2407
    @Rajsweety2407 4 года назад

    Where can we buy this.....

    • @robojax
      @robojax  4 года назад

      See the link in the description. We have no choice other than eBay, AliExpress or Amazon.

  • @never4u18
    @never4u18 2 года назад

    Hi,i have a problem with the bord...if the bord isn't running any program it's switched off....
    i want to make the board to wait for the trigger signal then run the program,any advices?

  • @tjalessi
    @tjalessi 2 года назад

    I am using program P-3 and I want to have a 600 second off and a 0.2 second on time. How can I set the timer to do this? When I change the 2nd parameter to 0.2 seconds the 1st (or off time) goes to 60.0 seconds. What am I doing wrong?

  • @AndrewAnew
    @AndrewAnew 4 года назад

    Hello, thank you for your video. It was helpful for me too. But I have question: At 4:00 you explain the trigger. and you say I can use an arduino etc. But I don't know how I can use a 12v alexa switch as trigger. Would I need to connect the 12v alexa ouput to the middle too?
    (I want to open a magnet lock with alexa and I have to assure it turns off / shuts automatically after a few seconds, otherwise the magnet lock overheats)
    Thanks in advance.

    • @robojax
      @robojax  4 года назад +1

      Hello. I never heard of "12v alexa". But regards less. you need to +12V and - or ground to connect and trigger this. Are you referring to Amazon Alexa? if so I've not used it.

    • @AndrewAnew
      @AndrewAnew 4 года назад

      @@robojax thank you for your answer. I meant I use a 12v switch for amazon alexa :)(www.amazon.de/gp/product/B07ZYVZQMR/) So I will probably be able to trigger it with it. thank you for the clarification. I am going to try it out :) have a nice day

  • @thomasgena9365
    @thomasgena9365 3 года назад +2

    Excellent video instruction. Thank you!

  • @96garage
    @96garage Год назад

    HI, Hope you will answer my question, a long time ago a Video was uploaded. Asking about 10A, does this mean that the relay must not receive more than 10A or the consumer must not be more than 10A?
    Sorry for my English, i hope u understand.
    Thank u :)

  • @Cornz38
    @Cornz38 6 лет назад +1

    Very useful. I have just received mine for my automatic plant watering system.

    • @robojax
      @robojax  6 лет назад

      Thank you.

    • @Ramii-x6x
      @Ramii-x6x 5 лет назад

      Does p-3 works continuously?

  • @Yet_Another_Steve
    @Yet_Another_Steve 3 года назад +3

    Fantastic video, thank you very much for the time you took to explain this with your clear & concise instructions. In P1 mode can I use the trigger to turn the light on and off with one momentary switch, or alternatively can I use the trigger to turn it on and remove power altogether to reset it to off with two momentary switches? I want to turn on and then turn off the light, but if the light is left on it should turn off automatically after a set time (canopy lights in a pickup bed). Thanks in anticipation.

  • @Milldog2023
    @Milldog2023 2 года назад

    Ok, i no nowt about relays etc, looking for motorbike, Wheni put the kick stand down, i want 4 led lights to light up for ex amount of time then switch off. Is this the gadget i need to add?..
    Cheers Mark. 👻

  • @fralam7791
    @fralam7791 Год назад

    complimernti per il video, faccio una domanda, se il modulo si può alimentare direttamente da un pannello fotovoltaico, capisco la variabilità della tensione, per alimentare una piccola pompa per acqua? la pompa deve funzionare solo di giorno quando c'è luce per il pannello, ringrazio per la risposta

  • @madeingreatbritainchannel
    @madeingreatbritainchannel Год назад

    How do you mount this in a control panel as the relay is higner than the LED display

    • @robojax
      @robojax  Год назад +1

      you are right. use some kond of IC socket, remove the dispaly, insert the socket, and then insert the display. Not sure but this is one way to braing the display up.

  • @renovarenergia4080
    @renovarenergia4080 8 месяцев назад

    Hi, I need to turn on an led strip (12v) for one second and when it turns off turn a different one for one second and alternating those two. Which module is suitable for this purpose? Thank you

    • @raresghinga2191
      @raresghinga2191 3 месяца назад

      you can use this, with the 2 gates, normally open and normally closed

  • @dirtchurch
    @dirtchurch 3 месяца назад

    I really like this timer. Can you help me on how i would install a counter.
    For example i need to record how many times the light turns on.
    Thanks

    • @robojax
      @robojax  3 месяца назад

      This is not customizable. You would need to build your own project using Arduino.

  • @DaveRepairs
    @DaveRepairs Год назад

    Useful but I need to make a delay switch from power on - does this store the settings ?

    • @robojax
      @robojax  Год назад

      All the settings are saved

  • @IkmalRusli
    @IkmalRusli 4 года назад

    Do you know how to turn off the led display ? for 2 buttons is press adn hold K1 , but for the 3 buttons i dont know

    • @robojax
      @robojax  4 года назад

      Everything this module can do I have explained it. So watch it without skipping and I am sure you will get the answer whither you can do it or not.

  • @noumman
    @noumman 5 месяцев назад

    Great video, I want to delay the relay to trigger after receiving a signal but stay triggered until signal disappears, Can this be done?

  • @omairbinenam6337
    @omairbinenam6337 3 года назад

    so you basically require three connections? one for powering up this relay. second to trigger the timer function and third for the appliance connected to COM, NO or NC? isn't that a bit messy?

    • @robojax
      @robojax  3 года назад

      Was it possible to do it some other way?

  • @michaelaquino28
    @michaelaquino28 2 года назад

    Thank you very much robojax! I am wondering what happens if the trigger is not removed in mode P-1?

    • @robojax
      @robojax  2 года назад

      I believe I have demonstrated it . If it was LOW to HIGH then it won’t have affect if stays there . I don’t remember what I did but watching video will give you the answer as I used diagram yo explain it

    • @michaelaquino28
      @michaelaquino28 Год назад

      @@robojax thank you for clarifying!

  • @user-ch7dz4ll3c
    @user-ch7dz4ll3c 3 года назад

    Hello I have found your video very helpful but I still have a problem. I have wired identical to the video but I have no output power. The green led illuminates on the timer ok and goes out but my external light won’t come on. Any help would be appreciated

  • @jacksonbartelli
    @jacksonbartelli 2 года назад

    Now I need something like that but if I keep trigger pressed I would like the time to start to count.. so either a short contact or a long contact timer must run no matter state of switch. Any ideas?

    • @robojax
      @robojax  2 года назад

      All possible functions have been explained. If you watched the video fully and did not find what you were looking for, then it can’t do it. Please watch.

  • @tattgurmatvichaar3369
    @tattgurmatvichaar3369 Год назад

    hi, great video and excellent presentation style. pls let me know say we hv set to program 3, continuous loop. what if this unit is switched off and then switched ON.... will it operate as per last setting. meaning the looping P3 program ?

  • @ECUDASHDIESELBIKOL
    @ECUDASHDIESELBIKOL 4 года назад

    What all I want is a delay time for like 10 seconds before the light turns on and the light stays on until I turn it off? Meaning, I will only use the delay time to turn on the lights.. Is it possible?

    • @robojax
      @robojax  4 года назад

      everything this module does I have explained it. Nothing is left without explaining. So please watch it fully without skipping and you should get the answer.

  • @Karl_Levine
    @Karl_Levine 4 года назад

    Does your video feature how you set a
    DELAY >>RelayOn forever setup???
    Couldn't understand if this simple delay to always on is set on this.
    Many thanks.

    • @robojax
      @robojax  4 года назад

      the "forever" if available I should have mentioned it . I never leave anything when I explain and review modules. so watch the video fully to get answer.

    • @Karl_Levine
      @Karl_Levine 4 года назад

      I did watch it all.
      But the video doesn't mention what happens if you set OFF time to 0 in any of the programs.
      What happens then?
      Thank you.

    • @leoridgeback
      @leoridgeback 3 года назад

      Tried without success had to get a different product to do a simple delay always on function.

  • @kokkenjot
    @kokkenjot Год назад

    Fantastic video. I have an application where I want the output to be disconnected for 120 seconds when triggered and then turn the relay on indefinitely. Can I do this with P1 by changing the wiring around on the output?

  • @gregzmanson
    @gregzmanson 29 дней назад

    On program 2 how do program it to stay on once it reaches the turn on point?

    • @robojax
      @robojax  29 дней назад

      all features have been fully explained. carefully watch the video multiple times to see which program best fits your need. I have no idea which program deos what. I made 100s of videos. But for sure I never skip explainign the features. so please watch.

  • @TheMattickus
    @TheMattickus 4 года назад

    Does this keep the settings if you disconnect all the power sources on it or do you have to set everything if you loose your power and grounds to the module?

    • @robojax
      @robojax  4 года назад

      yes it does.

  • @jasminek5780
    @jasminek5780 Год назад

    Hi this is so helpful. For my project I’m using this 12v relay but I’m only connection it to a 5v solar power manager. Will this mean that it won’t work cus it needs to be connected to a 12v power supply?

  • @Giannix
    @Giannix 2 года назад

    great job! i was thinking if is it possible instead of momentary switch, could we connect the xh-m609 to drive the time delay module?

  • @كثيرالطيب
    @كثيرالطيب 3 года назад

    Thanks for the explanation اشكرك على الشرح🇰🇼

  • @gavco11
    @gavco11 3 года назад

    Once again thank you for this help video as it has been a big help as this is a great product
    Thanks Gavin

  • @vangelispanteli2519
    @vangelispanteli2519 Год назад

    Thank you very much this video help me a lot. God bless you

  • @anandjoshi8554
    @anandjoshi8554 2 года назад

    Will its time value hold whenever power resumes after interruption? or get reset to zero ? Should I have to use inverter supply to hold its current value in P 1.1 setting ?

    • @robojax
      @robojax  2 года назад

      yes of course. it would be crazy to set it every time you turn it off .

    • @anandjoshi8554
      @anandjoshi8554 2 года назад

      @@robojax please clarify ur answer. Should I have to use inverter to hold last intrupted current time value
      OR without any inverter, the circuit will itself hold the last intrupted value ??!!! (please check yourself> because one youtuber said that it reset to zero, when power goes, so use inverter.
      I want to use it for 'reverse'''displaying time countdown''' in my project as time displayed in a washing machine.

  • @kocki3
    @kocki3 5 лет назад

    where can i download the manual, you announced at 15:18 minutes in your video?

    • @robojax
      @robojax  5 лет назад

      If the manual was useful, people would not watch the video. I made the video to make it easy. I don't remember now where is the file. I will try to find it.

    • @kocki3
      @kocki3 5 лет назад

      @@robojax Thanks

  • @yvesandreipal-ing2049
    @yvesandreipal-ing2049 25 дней назад

    In program 3, can we program it to 120min off then 20sec off?

    • @robojax
      @robojax  20 дней назад

      Watch and learn. It can be used millions of ways

  • @shashikantbhusari1759
    @shashikantbhusari1759 3 года назад

    Does this retain the input time after power cut or we need to set it evrytime we use it ?

  • @bucket1249
    @bucket1249 6 лет назад +1

    Excellent explanation I just ordered the 999 minute one from Amazon I'm going to use it for 12-volt DC I have an Factory time delay relay in the Machine but it's only good for 30 seconds and then my radio shuts off they never wired and accessory switch into the key so I must have it on to run the radio but at the same time it runs the electric power steering I'm going to use the trigger from the factory time delay to trigger this relay I can program it so the radio will stay up for 1 hour with the key off

    • @robojax
      @robojax  6 лет назад

      Thank you. I am glad you liked it.

    • @majidzarei6695
      @majidzarei6695 5 лет назад

      Hi , if we need a timer that connect or disconnect circuits after 6 hours what should we do? What should we buy? As I realized, this module go up to 999 s at last.

    • @jcdan8502
      @jcdan8502 4 года назад

      Hi sir robojax... what is the exact name of this module sir... want to buy one sir.. hope u can send the details of this eelay sir. Ty ang more power..😊

  • @expositor4sure
    @expositor4sure 2 года назад

    Hi. Just wanted to ask.. in this setup can we get 2 bulbs in the relay no and nc and in p3 we set time duration of say 8 seconds each would it light the alternate bulbs infinitely or after some time it will turn off after say 10 repetitions. Thanks

    • @robojax
      @robojax  2 года назад

      Hi, both load or AC bulb will turn on and off together.

    • @expositor4sure
      @expositor4sure 2 года назад

      @@robojax thanks for your reply, i wanted to run 2 set of linear actuators which are powered by a 12v geared motor , i wish to run both motors in 2 ways . One when its n.o. they will rotate clockwise and in n.c. condition they rotate anti clock wise. Is it possible? Building a mechanism where the actuators move up n down during the cycle.

    • @robojax
      @robojax  2 года назад

      They can operate the opposite of each other yes . One will turn on and the other will turn off. Yes. But not independent operations at different timing as we have only one relay. Birth must be operation with the same voltage.

    • @expositor4sure
      @expositor4sure 2 года назад

      @@robojax can i get your emal id so that i can communicate better? Really wanted to understand this.

  • @AndrewAnew
    @AndrewAnew 4 года назад

    Hello Robojax, thank you for your detailed video. I bought the timer, not realizing, that the trigger ALWAYS has turn off in order to make the timer start and let a lamp turn off after some seconds. Is there a way, to accomplish that with this relais?: Trigger: turn on the lamp - wait 5 seconds - turn off the lamp. The state of the trigger would be irrelevant.
    If this is not possible with this relais, do you know a relais with that I can do this? I would be very thankful If you could / would help me.
    thanks a lot. Andrew

    • @robojax
      @robojax  4 года назад

      Hello and welcome. if the trigger is the issue, you can change the trigger signal use this circuit very easily snipboard.io/vERWPt.jpg I have move timers with both HIGH and LOW trigger types. I try to explain everything but don't remember now which one is which as I have over 400 videos as of now and hard to track them. Good luck.

    • @AndrewAnew
      @AndrewAnew 4 года назад

      Robojax Hello Robojax, thanks alot for answering. Well the trigger isnt really the problem, it works. The problem is, that the trigger doesn‘t turn off automatically. This wouldn‘t be a problem if the timer (P-2) would start immediately after the trigger was recognized. The problem is, that the relais waits for the trigger signal to turn off. But in my case this will never happen. Therefore I cant use this relais. Is there really no way of acheiving this? ☹️

  • @wil46nl
    @wil46nl Год назад

    Nice video, well made. I have another board like that vhm-013. Has only two connectors. One for +_12v and one for the relais. Would you know how I can trigger the timer with this one?

  • @lauralissettresendizramire3229
    @lauralissettresendizramire3229 4 года назад

    usare un sensor para activación pero se quedara en flanco de subida durante un tiempo mas, es posible que el programa comience con el flanco de subida y no de bajada?

    • @robojax
      @robojax  4 года назад

      No tengo el módulo en la mano ahora para probarlo y hacerle saber. Pero puedo decirte que no he dejado nada fuera y les expliqué. Mire el video más de una vez sin saltearlo y debería obtener su respuesta. Digamos gracias por cualquier trabajo que alguien haga por nosotros.

  • @thra5herxb12s
    @thra5herxb12s 5 лет назад

    Hi there. Can I set the timing to act as a strobe effect ?

    • @robojax
      @robojax  5 лет назад

      sorry what is strobe effect? Are you referring to "turn ON and OFF multiple times" of the light? if so NO.

  • @brightideas5782
    @brightideas5782 4 года назад +1

    Awesome presentation! ! Question can I attache green trigger wire to a vibration sensor? And to a Bluetooth board ?

  • @vigatex
    @vigatex 4 года назад

    Hi,
    I did set it up in order to switch on and off a dv voltage but no luck when using the Ck and COM pins.
    Is this not supposed to work with 5V DC voltage?

    • @robojax
      @robojax  4 года назад

      it will work. Even 1 or 2V will work. Either setting is incorrect or wiring. check it.

    • @vigatex
      @vigatex 4 года назад

      @@robojax Hi again,
      I do get a HIGH state from the Arduino pin as I used a voltmeter and got a 5V reading every time the code set pin no 8 to HIGH.
      Ibthen run a continuutyvtest on the output pins and notived that the commonly closes pin was always allowing voltage through regardless of the code and the commonly open was constantly open

  • @keri5320
    @keri5320 3 года назад

    Do you know of a relay that is like program 1 but then also has a delay where the program cannot be resignaled for a duration of time?

    • @robojax
      @robojax  3 года назад

      I don't remember what program 1 does, but you can search my channel for "relay timer" I have so many.

    • @keri5320
      @keri5320 3 года назад +1

      @@robojax program 1 turns on once signalled and stays on for T1. Once T1 is 0 relay turns off. Thanks I will have a look and see if I can find something

  • @d.charalampopoulos
    @d.charalampopoulos 5 лет назад

    Hi Robojax
    I would like to know what is the minimum voltage needed to triger the divice? is it 4v - 20v? I am trying to use the device with a sencor that says it can give max 200mA. It is not working.
    I was looking also to use an infared sensor or an ultrasonic sescor .
    i have the module that you have and i want to use it like a simple secutity system.....
    please upload a video with what kind of sensors we need to triger the devise ....what is the diffr. with possive and negative triger?
    this devise says it works with possitive but the sencor that i have says that sents negative.....
    Any help or idies?
    Thank a lot and great video by the way......

    • @robojax
      @robojax  5 лет назад

      Hi Dimitris, As I mentioned at 1:25 (click on the 1:25. I had to watch the video to find it) it is triggered at 5V. Anyting above up to 12 should be find. It doesn't need much current perhaps less than 1mA.
      If you want to change input signal from negative to positive, you would need a transistor and 2 resistors. but I would suggest using Arduino with relay which gives you very wide options to work with. Here I just made this circuit if you want to convert the signal from positive to negative snag.gy/vERWPt.jpg

  • @ramzein776
    @ramzein776 5 лет назад +1

    is it possible to keep it on for few sec and off continuously till power disconnected ? like a windscreen wiper

    • @robojax
      @robojax  5 лет назад

      All the features have been explained. If you can't find the feature you are looking for, then it doesn't' have it. Use Arduino and program it exactly the way you want. this is for people who have limited expectation.

  • @fmfxpvtltd8260
    @fmfxpvtltd8260 5 лет назад

    Hi, not sure if you are still answering questions in regard to this unit: I have the same unit but 24v DC and I would like to use a 12v PIR unit for the signal. Will this be recognised?

    • @robojax
      @robojax  5 лет назад

      I will reply to all Subscriber's 🔔 questions. So make sure to Subscribe.😊. You haven't Subscribed yet. I spent hours recording and preparing it so you learn, what is single click to subscribe in return?

    • @fmfxpvtltd8260
      @fmfxpvtltd8260 5 лет назад

      @@robojax I have subscribed. The 'Subscribe Button" above is no longer RED so I presume that it is registered.
      This is copied from my Subscribe List:
      SUBSCRIPTIONS
      Robojax

  • @tall-handsome7152
    @tall-handsome7152 4 года назад

    Thank you very much for your detailed explanation. This is exactly what I need to add my front camera to my car parking system.

    • @robojax
      @robojax  4 года назад +1

      You are welcome! I am glad it helped. Ahmad from Canada (Hurasan)

  • @tomjdesigns1280
    @tomjdesigns1280 4 года назад

    Does this extra wire for reset is positive +12V? Will it work when power and trigger are switch on the same time?

    • @robojax
      @robojax  4 года назад

      Unless I set this up, I will not know. But for sure at the best of knowledge, I have not left any feature without explaining. So watch it fully without skipping, I am sure you will find the answer.

  • @Drrrre
    @Drrrre 2 года назад

    Should the power source and/or trigger signal input be fused? Rating?

    • @robojax
      @robojax  2 года назад

      Any device you control should have its own protection.

    • @Drrrre
      @Drrrre 2 года назад

      @@robojax but do you know what the fuse rating should be for this device?

  • @islakkie
    @islakkie 3 года назад

    Awsome This helped me to find the right function. Thanks!!!!!

    • @robojax
      @robojax  3 года назад

      You are welcome. Please subscribe. I appreciate it and helps my channel grow. Thank you

  • @maujanzaonline9339
    @maujanzaonline9339 5 лет назад

    I mean can I connect the switch that used in vibration module that when shocked it will tegger as the switch that you connect in your video

    • @robojax
      @robojax  5 лет назад

      Sorry I did not understand. I have explained it but let me tell you again. This board has INPUT and your device or vibration device has OUTPUT. So if your device give voltage at OUTPUT, then connect it to this module INPUT, it should work.

  • @jonathanmsmbe331
    @jonathanmsmbe331 2 года назад

    Hello sir, do you know what the max input voltage is on device? I have the voltage in my vehicle set around 15.5v but no more than 15.7v on cold days.

    • @robojax
      @robojax  2 года назад +1

      Hello, rated voltage is 12V. The relay might handle 0.5V more.

    • @jonathanmsmbe331
      @jonathanmsmbe331 2 года назад

      @@robojax okay. Thank you!

  • @martelmarteau4502
    @martelmarteau4502 4 года назад +1

    Thank you so much ...... exactly what I was looking for.... I bought one, but could not
    use it, as I was not able to not understand their explanations (from the seller on ali...)

    • @robojax
      @robojax  4 года назад

      You are welcome. Thank you for not skipping the ads and keep watching it. This will help me a lot.

    • @martelmarteau4502
      @martelmarteau4502 4 года назад

      @@robojax I will ....

  • @CjPersonal-w3q
    @CjPersonal-w3q 3 месяца назад

    Hi Ahmad,
    I'm truly new to all this, but I have to finish a project that involves this type of mechanism, though the one I need has to have a
    • physically separated switch
    • a small beeper for sound
    • a timer of 1-15 seconds
    The idea is that once I regulate the timer, let's say to around 9 seconds, I will be able to press the switch, and the sound beeper will make a beep sound after 9 seconds. I would do this continuously.
    I would be truly appreciative for your guidance in figuring out which one I need to buy online, probably from Amazon or from any place I can buy it from.
    Regards,
    CJ

  • @dirkwalther2354
    @dirkwalther2354 3 года назад

    Ein sehr gut gemachtes Video! Danke dafür. Beste Grüße aus Deutschland. :)

    • @robojax
      @robojax  3 года назад

      Ich freue mich, dass Sie es nützlich fanden. Grüße von Ahmad aus Kanada. Bleib sicher.

  • @fazimabdool6437
    @fazimabdool6437 Год назад

    Great video bro ...one quick question..i need a timer that comes on at a specific time of the day but for only 5 seconds...can you recommend one please

  • @ShaSha-mt8on
    @ShaSha-mt8on 4 года назад

    A comprehensive presentation...very helpful friend..👍

    • @robojax
      @robojax  4 года назад

      Glad you liked it

  • @medi0.350
    @medi0.350 6 лет назад

    Is there a way to start the countdown in P-1 without the manually triggering.? I mean itwill auto countdown when there is 12v supply.

    • @robojax
      @robojax  6 лет назад

      Trigger is part of program. The example I have given in this video should answer any question you have unless it is impossible to do it with this module.

  • @myshuker1978
    @myshuker1978 4 года назад

    hey and thank for th vedio
    I want to ask you where can I find (off delay timer 12v in the market) the counter start to count when I cut the power?
    I mean i want it delay off..12 volt with relay
    when i press power the light turn on and it countinus lighting until I cut power off then the light turn off after 5second

    • @robojax
      @robojax  4 года назад

      I hope off delay means instead of turning something on, u want it off. If that’s the case then it is the wiring of this module with relay. Keep the middle wire of your load at the same terminal if the relay and move the other wife mite to the UoIT her unused terminal.

  • @hanggararachmabrata9418
    @hanggararachmabrata9418 4 года назад

    Sir, so it needs 12V power supply for trigger site or we can use it without power supply on trigger site?

    • @robojax
      @robojax  4 года назад

      I don't remember the voltage. but I should have explained.

  • @nishsneha
    @nishsneha 4 года назад

    Thank you so much for the detailed information. I've managed to connect the relay to my Dahua Intercom which is connected to a electric door strike. I managed to power the relay and got the trigger working so that it start counting down in P-1 settings. However, when connecting my 2-wire electric door strike - it doesn't seem to receive any power. The LED light does come on when the trigger is activated & last throughout the countdown but no power seems to be going to the door strike. Any idea why?

    • @robojax
      @robojax  4 года назад +1

      You are very welcome. Are you saying that you connected your door strike, instead of the bulb shown in video and it is not turning ON and OFF? if relay clicks and hear it, then your wiring is incorrect. I assume your door device is functioning. test it without connecting it to this module. Connect another load AC or DC bulb and test it. Perhaps the relay connectors on the module are bad. good luck.

    • @nishsneha
      @nishsneha 4 года назад

      @@robojax Thanks for the update and got this sorted as I forgot to connect the power source for the electric door strike. Once again, much appreciated your speedy reply and follow-up.

  • @akshayshaji768
    @akshayshaji768 2 года назад

    does it work with out trigger..means clock timer..automatic works in time and hold it for minitus?

    • @robojax
      @robojax  2 года назад

      made the video exactly to answer these types of questions. please watch and if you did not find what you were looking for, then this module can't do it.

  • @furkanklc1908
    @furkanklc1908 3 года назад

    Hello sir I need help, how can I make 5 bulbs light up one by one by one time pressing to the button?, Do I need 5 timer relays or a timer relay with 5 channel? thank you in advance!

    • @robojax
      @robojax  3 года назад +1

      yes you need 5 of this module. Arduino is best option. you can do any way you wan them. here is 4 channel ruclips.net/video/Wbm3MCMgM_s/видео.html relay

  • @zenotm
    @zenotm 3 года назад

    Hello,i need a 12v timmer that shoul do 10 sec on and 600 off in endless loop, can this relay do this ?thanks

    • @robojax
      @robojax  3 года назад +1

      Hello, I have published over 450 videos and don't remember what this relay did. But my rule is to explain things fully. So you have to watch all features of this module and see which one works for you. good luck

    • @zenotm
      @zenotm 3 года назад

      @@robojax Thanks !

  • @Jai-ku1oc
    @Jai-ku1oc Год назад

    Very good video, nicely explained. Do you know if the relay can be kept energised when power is applied. Thanks.

    • @robojax
      @robojax  Год назад +1

      the relay only reacts when the program turns it on.

  • @gnsmk
    @gnsmk 3 года назад

    Can you program it for be on for seconds and off for hours ? mix seconds and hours or minutes ?

    • @robojax
      @robojax  3 года назад

      In and off are independent. 1 hour 60x60=3600 seconds so program it as you wish. But this can go up to 999 seconds. See other module I have reviewed with 999 hours

  • @dan2384
    @dan2384 5 лет назад

    If I put the 12v in the 12v+ and the minus/black to the trigger. Can I trigger the circuit with the K1 button on the board?