  • @Baltytraders
    @Baltytraders 4 года назад +3

    Very good keep it up 👍 waiting for your new video

  • @liopal1000
    @liopal1000 Год назад

    How does the Graham Viking relief valve work?

  • @임언수-e7b
    @임언수-e7b Год назад

    Hi. Can you share the information? How set vacuum pressure of vacuum breaker which installed on highest postion with vertical pipe line?

  • @ABKhan_
    @ABKhan_ Год назад

    Hi plz advise does the hot and cold water need separate vaccum valve and does a semi pressure geyser need balancing thank you

  • @shahabsarbandi1981
    @shahabsarbandi1981 2 года назад +2

    Perfect

  • @rajinthss7732
    @rajinthss7732 3 года назад +1

    Nice video, one small correction at 2:40, it should say elongate the spring*, not compress.

    • @lyellw571
      @lyellw571 2 года назад

      The surface that the spring compresses against isn’t shown in the moving diagram at 2:40, but you can see it in the diagram at 1:10.

  • @anaggarw1
    @anaggarw1 4 года назад

    Hi. Do you know some good manufacturers of the vacuum breakers in India besides Protego and PFCI?

  • @shijovarghese2771
    @shijovarghese2771 4 года назад +2

    sir I have one doubt vacuum breaker and breather valve are same function? pls send replay

    • @TECHNICALPIPING
      @TECHNICALPIPING  4 года назад +2

      Pressure/vacuum relief valves are protection devices which are typically mounted on a nozzle opening on the top of a fixed roof atmospheric storage tank. Their primary purpose is to protect the tank against rupturing or imploding. Without an opening or a controlled opening, a fixed roof atmospheric tank would rupture under increasing pressure caused by pumping liquid into the tank or as a result of vapor pressure changes caused by severe thermal changes. Imploding, or the collapsing of a tank, occurs during the pumping out procedure or thermal changes. As the liquid level lowers, the vapor space pressure is reduced to below atmospheric pressure. This vacuum condition must be controlled by allowing atmospheric air to flow into the tank. In short, the tank needs to breathe in order to eliminate the possibility of rupturing or imploding. Because of its primary function, a pressure/vacuum valve is commonly referred to as a “breather valve.”

    • @Leoshipman21
      @Leoshipman21 4 года назад

      @@TECHNICALPIPING thats a perfect reply. Completely understood. But when the líquid is reducing level during pumping out nas vaccum being formed , if the atmospheric air gets in touch with the cargo still inside the tank, cant it get ignition / explosion in case cargo is flammable??

  • @cck0728
    @cck0728 4 года назад +1

    Excellent video. What is a "water column" in pipeline?

    • @TECHNICALPIPING
      @TECHNICALPIPING  4 года назад

      Column separation refers to the breaking of liquid columns in fully filled pipelines. This may occur in a water hammer event when the pressure drops to the vapor pressure at specific locations such as closed ends, high points or knees (changes in pipe slope).

  • @christomathew2773
    @christomathew2773 Месяц назад

    Why vacuum breaker won’t work if I put a control valve on down flow after the vacuum breaker