Limit of Blank (LOB), Limit of detection (LOD) and Limit of quantification (LOQ) | LOB,LOD and LOQ

Поделиться
HTML-код
  • Опубликовано: 18 сен 2024
  • Hello all.. In this video I have explained about Limit of Blank (LOB), Limit of detection (LOD) and Limit of quantification (LOQ)
    For PPT follow the link : docs.google.co...
    #limitofblank
    #limitofdetection
    #limitofquantification
    This channel would be helpful to MBBS, PG, NEET preparation, USMLE preparation , EXIT exam, NEXT exam, Nursing ,Physiotheraphy, Dental ,MSc, Biotechnology and B.Pharm students to understand the basic medical subject
    My youtube link : / livebiochemistry
    Don't forget to LIKE,COMMENT SHARE & SUBSCRIBE ...
    Subscription link : www.youtube.co...
    Chemistry and Metabolism of Carbohydrates : • Carbohydrates
    · Chemistry and Metabolism of Proteins : • Proteins
    · Chemistry and Metabolism of Lipids : • LIPIDS
    · Enzymes : • Enzymes
    · Vitamins : • Vitamines
    · Minerals : • Minerals
    · Hemoglobin Metabolism : • hemglobin metabolism
    · Genetics/Molecular Biology : • Genetics | Molecular B...
    · Molecular techniques : • Molecular techniqes
    · Nucleotide Metabolism : • Nucleotide metabolism
    · Organ Function tests : • Organ function tests
    · Metabolism of xenobiotics : • Metabolism of xenobiot...
    Follow me on
    instagram :- / aggravat1616
    Facebook - / ashish.agravatt
    Twiitter : / ashu_dr
    Telegram : t.me/livebiochemistry
    Linkedin : / dr-ashish-agravatt-a15...
    email : drashishagravatt@gmail.com
    THANKS FOR WATCHING #biochemistry #livebiochemistry#drashishagravatt

Комментарии • 7

  • @KaloferChushkov
    @KaloferChushkov 2 года назад +2

    Thank you very much for making these, your tutelage is amazing and I'm sure everyone who has seen these videos is very grateful. I will be recommending them to my chemical pathology trainee colleagues here in Scotland.
    I was curious if you could answer why for LoQ you say CV can be 50% of TAE but then in the subsequent slide you say that within-run CV can be 25% and between-run CV can be 33%. Would it not be acceptable to get any combination of these values provided that the square root of the sum of their squares (i.e. total CV) remains 50%?
    Thank you again for your time and effort in making these!

    • @livebiochemistry
      @livebiochemistry  2 года назад

      Hi Sava Handijev. Thank you for your comment
      About CV of 50 % of TAE will be in case of assumption of 0 % bias
      Between CV 33% we can apply for between run and keep remaining 34 % for bias...
      I agree with you in doing square root of sum of squares to within run and between run . it will be total standard deviation.. but can not keep it to 50% as we have to keep space for bias also

    • @livebiochemistry
      @livebiochemistry  2 года назад

      if you have further query kindly mail on drashishagravatt@gmail.com and discuss further

  • @mohammedalseraji5342
    @mohammedalseraji5342 2 года назад +1

    Thnx

  • @mohammedalseraji5342
    @mohammedalseraji5342 2 года назад +1

    I have old instrument Atomic Absorpance shimadzu 6800.How I can determine LOD of metals. I know Rang of standars.

    • @livebiochemistry
      @livebiochemistry  Год назад

      Concepts remains the same .take 0 calibrator near by low calibrator