    @sopankale1807 2 года назад +4

    Q18 The synchronous motor is made self-starting by providing a special winding on the rotor poles, known as damper winding or squirrel cage winding. AC supply given to the stator produces a rotating magnetic field which causes the rotor to rotate.

  • @anandsharma4174
    @anandsharma4174 3 года назад +7

    Superb sir,thank you for your efforts for us.

  • @saleemmarri9165
    @saleemmarri9165 2 года назад

    Bahth hii zaberdast sir ..I improved alot from ur lectures ..Salam from pakistan

  • @ManishKumar-of8dq
    @ManishKumar-of8dq Год назад

    Questions no 12 synchronous motor run at unity pf

  • @mysticismonflute
    @mysticismonflute 3 года назад +6

    Sir in case of question 14 there are 2 options of 90 degrees...and aisa exam me bhi hota hai to ham konsa select kare...?

  • @tatabirala8419
    @tatabirala8419 5 лет назад +1

    In question 23 if excitation get cutoff it will run as reluctant motor if generated electromagnetic torque is more than load torque...

  • @Vk_rsw
    @Vk_rsw 2 года назад

    Superb

  • @shubhamshende9995
    @shubhamshende9995 3 года назад

    Good job sir

  • @kapilmatoria3894
    @kapilmatoria3894 5 лет назад +2

    Power developed is maximum when load angle is 45 .. P = EV/Xd * sinδ + V²/2 * (Xd-Xq)/(Xd*Xq) *sin2δ

    • @ElectricalEngineeringMCQs
      @ElectricalEngineeringMCQs  5 лет назад +1

      I appreciate your keen observation Kapil. This question was not deliberately gone into the depth of direct axis and quadrature axis reactance. We are not considering the effect of V²/2 * (Xd-Xq)/(Xd*Xq) *sin2δ here so if we put δ=90 which gives sin90 nearly to 1 so does we get maximum power. I hope you understood it.

    • @kapilmatoria3894
      @kapilmatoria3894 5 лет назад

      @@ElectricalEngineeringMCQs you have to keep this in consideration because you have explained that synchronous motor has Salient pole rotor which is partially correct because it also has cylinderical rotor which is used in thermal power plant.
      Coming back to maximum power quadrature axis reactance can't be ignored in salient pole rotor. It can be ignored in cylinderical rotor which you have neglected in very first question.

    • @ElectricalEngineeringMCQs
      @ElectricalEngineeringMCQs  5 лет назад +1

      ​@@kapilmatoria3894 Indeed, I will consider this in next sessions so to have better clarity. I appreciate your kind explanation. Moreover, you may have observed that salient pole synchronous machines are more stable than the cylindrical rotor because Xd the direct axis reactance is lower than Xq (quadrature axis reactance) hence rotor remains more stable(in elect. power supply), compare to round rotor where Xd=Xq. Even maximum power transfer(Pm) occurs at a torque angle delta less than 90 degrees. Yet for high speed elect. power generators, round rotor are used, as are the more stable mechanical point of view. I have considered some of these points and came up with this conclusion, and considering the mcqs which I have explained from the synchronous chapter are the questions which have been generally asked in the examination. I hope you understood the same Kapil. Stay tuned.

  • @sathishraikindi96
    @sathishraikindi96 4 года назад +1

    Super sir

  • @anilkamble9312
    @anilkamble9312 8 месяцев назад

    Great….

  • @lingamurthy4079
    @lingamurthy4079 2 года назад +1

    Q1
    Ans:-Two types of rotor are used in synchronous motor

  • @maxclass985
    @maxclass985 4 года назад +2

    Non salient pole is also known as cylindrical rotor type of synchronou motor

  • @WBP.K
    @WBP.K Год назад

    West Bengal PSC JE ka session kara doo sir

  • @tatabirala8419
    @tatabirala8419 5 лет назад

    In question 28 synchronous motor operating power factor .8 leading ..

  • @ajayattri9251
    @ajayattri9251 5 лет назад +2

    Sir continuous video

  • @jaideepchoudhary6501
    @jaideepchoudhary6501 4 года назад

    sir synchronous motor most stable unity power factor pe hogi. na ki leading pe..que,12

  • @pranjalsrivastava1962
    @pranjalsrivastava1962 5 лет назад

    Sir what is the power developed by a synchronous motor....
    According to u if we put 0 degree as torque angle in thr फार्मूला v*eb/xs **sin§ if we put del is equal to 0 then the power developed is 0
    M i right sir or not??

  • @er.parmjeetsingh5036
    @er.parmjeetsingh5036 4 года назад

    Thanks

  • @hellothere637
    @hellothere637 5 лет назад

    Please provide mcqs on power quality issues for MPSC MES MAINS exam.

  • @UsmanKhan-zz4bx
    @UsmanKhan-zz4bx 4 года назад +1

    Question 18 answer may be option A.

  • @manishkumar-vn9do
    @manishkumar-vn9do 4 года назад +1

    Sir questions no. 22 ka supply voltage change bhi to ho Sakta hai explain plz

    • @ElectricalEngineeringMCQs
      @ElectricalEngineeringMCQs  4 года назад

      Yes but for a fixed operating speed the most significant is to change the Frequency.

  • @bholubareth9949
    @bholubareth9949 5 лет назад

    Please make vedios of measurement and include numerical also

  • @RAKHAL358
    @RAKHAL358 3 года назад

    Sir have you cross check the Q. No 18

  • @amangiri407
    @amangiri407 7 месяцев назад

    6:52

  • @sanketaswar6729
    @sanketaswar6729 5 лет назад

    I like very nice

  • @ranjeetjaiswal1341
    @ranjeetjaiswal1341 6 месяцев назад

    18 ka A hoga

  • @shashankkumar174
    @shashankkumar174 5 лет назад

    nice

  • @manishkumar-vn9do
    @manishkumar-vn9do 4 года назад +1

    Sir questions no. 15 ka answer achhi tarah explain kar dijiye

  • @karlakuntavijaykumar2959
    @karlakuntavijaykumar2959 4 года назад

    Hi sir

  • @salmansawer9682
    @salmansawer9682 5 лет назад +1

    Sir v curve Apne galat banaya hai x axis field current hoga tab na excitation change karne pe armature current ayega mean ia depends on If

    • @ElectricalEngineeringMCQs
      @ElectricalEngineeringMCQs  5 лет назад

      I appreciate your keen observation salman and thank you for your kind correction. The explained curve has been blurred out to avoid confusion and corrected figure will be uploaded in the pdf as well. Stay tuned and DO share.

  • @Vibha4
    @Vibha4 3 года назад +2

    there is a mistake in Ques.18- damper windings on rotor poles should be the answer.

    • @ElectricalEngineeringMCQs
      @ElectricalEngineeringMCQs  3 года назад

      Thank you Vibha for your kind response i will crosscheck the same soon.

    • @Veerkushwaha-s5s
      @Veerkushwaha-s5s 3 года назад

      Yes sir ans of que no 18 will be damper winding on rotor poles

  • @manishkumar-vn9do
    @manishkumar-vn9do 4 года назад +1

    Sir questions 17 ja answer to aapne field current bataya tha, ye load angle kaise ho gaya

  • @ratikantamahapatra8847
    @ratikantamahapatra8847 5 лет назад

    what is the difference between Field and Armature?

    • @shaileshbirajdar1963
      @shaileshbirajdar1963 2 года назад

      Winding which produces main flux called field winding where winding carrying current( Load or source current) called armature winding

  • @KuMaRkUmAR-wr1yt
    @KuMaRkUmAR-wr1yt 5 лет назад

    Sir please make video on important numericals for rrb je level from machine and Power system

  • @vamsikrishnaallu8809
    @vamsikrishnaallu8809 5 лет назад

    Q 18 answer may be option 1

  • @KrushnaChmeher-is7qw
    @KrushnaChmeher-is7qw 5 лет назад

    Database mcq bi hona chahiye

  • @rhehehdhd
    @rhehehdhd 2 месяца назад

    Hllo sir please request ukssc je. Upcl PTCUL je paper solution electrical engineering

  • @harrykaushik2508
    @harrykaushik2508 5 лет назад

    Sir haryana jee ka paper hai 1 sept ko pls sir electrical jee k jitne b important questions ho pls 1 video bna do sir 1 sept se pehle pls

  • @panwar8016
    @panwar8016 5 лет назад

    i m having CONFUSION IN QUESTION NO " 13"
    I THINK CORRECT ANSWER IS "90 DEGREE"

    • @pranjalsrivastava1962
      @pranjalsrivastava1962 5 лет назад

      How's 90 degree... Torque angle is the angle between rotor and stator. while no load the angle between this two is 0... Bcoz they are coincide each other... Dont confused its very simple to think

  • @riteshmehra2879
    @riteshmehra2879 5 лет назад

    Sir,
    Kindly share synchronous motor pdf

  • @satishlilwan4640
    @satishlilwan4640 5 лет назад

    sir theori class suru kare jaldi

  • @SachinSharma-xy1rf
    @SachinSharma-xy1rf 5 лет назад

    Bhai pls volume loud karo

  • @rakeshnambiar9431
    @rakeshnambiar9431 4 года назад

    Sir, please share the pdf of this video if u have.. Very urgent for me.

    • @ElectricalEngineeringMCQs
      @ElectricalEngineeringMCQs  4 года назад +1

      PDF has been uploaded on the telegram. Kindly DO Download Rakesh and Share it with your friends.

    • @rakeshnambiar9431
      @rakeshnambiar9431 4 года назад

      @@ElectricalEngineeringMCQs Okay Sure Sir..
      Thankzz For the Reply

  • @हाव7ज
    @हाव7ज 3 года назад

    Sir 18 ka a hona chahiye

    • @ElectricalEngineeringMCQs
      @ElectricalEngineeringMCQs  3 года назад

      Thank you for your response Satyam I will crosscheck and rectify if any and same will be updated in the PDF as well DO Share this session with your friends.

  • @gangadhardas3318
    @gangadhardas3318 4 года назад

    Damper winding Kia hai💥💥💥

    • @ElectricalEngineeringMCQs
      @ElectricalEngineeringMCQs  4 года назад

      Damper winding helps to start synchronous motor as a Induction motor in its initial run.

  • @animalsloverentertainment7213
    @animalsloverentertainment7213 2 года назад

    Answer bhi likh diya kro na ,

  • @angelgirl6789
    @angelgirl6789 3 года назад

    Sir I have a all subject's pdf plz sir

  • @vikashverma7613
    @vikashverma7613 5 лет назад

    Sir iska pdf de dijiye

  • @shivansingh7115
    @shivansingh7115 4 года назад

    sir pdf

  • @mampidas9070
    @mampidas9070 3 года назад

    Sir apdcl ke liya JE ka paper solve digiaa..... It's so important.... 🙏🙏🙏

    • @ElectricalEngineeringMCQs
      @ElectricalEngineeringMCQs  3 года назад

      Sure. I have taken your request Kindly Stay tuned I will try to upload the same shortly.

  • @ringmaster6371
    @ringmaster6371 4 года назад +1

    Copy of V K mehta objective questions..

    • @ElectricalEngineeringMCQs
      @ElectricalEngineeringMCQs  4 года назад +1

      Understanding is the key! Kindly DO Explore our recent sessions as well and Share them with your friends.

  • @errathvamukesh2313
    @errathvamukesh2313 4 года назад

    Sir Help me Electrical MCQ ??

  • @हाव7ज
    @हाव7ज 3 года назад

    33 vala nhi samjh me aya

    • @ElectricalEngineeringMCQs
      @ElectricalEngineeringMCQs  3 года назад

      I will consider the same question soon Satyam. Kindly DO Share this session with your friends.

  • @raviduttdhiman6493
    @raviduttdhiman6493 4 года назад

    प्रशन पढ भी नही पाते है बहुत जलदी करते हो

    • @ElectricalEngineeringMCQs
      @ElectricalEngineeringMCQs  4 года назад

      Thank you ravidutt for your kind feedback I have noted your kind suggestion. Kindly stay tuned and DO Share.