    @singhsahab6080 4 года назад +4

    VUP,LVUP AND PUP ke liye -
    1. minimum and maximum vertical clearance kitna rahega...?
    2. Minimum and maximum horizontal clearance kitna rhega..??

  • @DANISHKHAN-cu6oz
    @DANISHKHAN-cu6oz 2 года назад

    ROB, RUB & FLYOVER ka size Length width height kitna rahta h

  • @dodouniquelife9725
    @dodouniquelife9725 Год назад

    Thank You Very Much

  • @sarveshrajpoot8708
    @sarveshrajpoot8708 3 года назад +1

    Thanku

  • @jaibhardwaj8260
    @jaibhardwaj8260 2 года назад

    Thanks,Sir

  • @Shorts4Fun8655
    @Shorts4Fun8655 2 года назад

    Jo railway platform pr bnta hain use kya kahenge sir

  • @DANISHKHAN-cu6oz
    @DANISHKHAN-cu6oz 2 года назад

    ROB, RUB & Flyover ka kya criteria hota h ?

  • @sipakmishra3010
    @sipakmishra3010 2 года назад

    Very nice Or knowledgeable video sir

  • @vivekmath2436
    @vivekmath2436 3 года назад +3

    In Railways, If span is 18 or more than 18 mtrs it will be considered as major Bridge

  • @Its.CivilEngineering9
    @Its.CivilEngineering9 Год назад

    Thank you sir 😙

  • @naipalsingh9848
    @naipalsingh9848 3 года назад +1

    PUP KI MINIMUM HEIGHT ?
    Structure Code?
    3.soil test starting Vup?

  • @user-hr6im9xi3p
    @user-hr6im9xi3p 2 года назад

    Yes I want excel sheet this, I am subscribe this channel

  • @Vijendrakumar-kg8el
    @Vijendrakumar-kg8el 3 года назад +3

    Sir RE wall Ka scope Kaisa h
    structure and re wall m kya best h
    Plz reply me sir 🙏🙏🙏

    • @success555
      @success555  3 года назад +2

      Structure is best.
      RE wall is just one small part.

    • @Vijendrakumar-kg8el
      @Vijendrakumar-kg8el 3 года назад +1

      @@success555 thank you sir

    • @success555
      @success555  3 года назад +1

      Welcome bro.

    • @Vijendrakumar-kg8el
      @Vijendrakumar-kg8el 3 года назад +1

      @@success555 sir koi job h Aapke pass structure m

    • @success555
      @success555  3 года назад

      Send your cv to success555888@gmail.com

  • @civilSea
    @civilSea 3 года назад +1

    Nice information provided

  • @ravisharma2279
    @ravisharma2279 2 года назад

    Hii sir
    Eska marking kaise hota hai
    Jaise likha rahta hai mnj 218/1, mnr 218/2

  • @civilengineeringworks3910
    @civilengineeringworks3910 4 года назад +2

    Shukria sir ji but sir lvup, cup, pup ki minimum clearance hight btadijiye

  • @rajdayma6410
    @rajdayma6410 3 года назад

    Thnx

  • @VIVEKKUMAR-ox7tb
    @VIVEKKUMAR-ox7tb 2 года назад

    Thank u so much sir 🙏🙏🙏

    • @success555
      @success555  2 года назад

      Subscribe the channel and share the video.

  • @youtubeBABA_0
    @youtubeBABA_0 Год назад

    Sir Interchange pr video daliye

  • @raviprakash8323
    @raviprakash8323 2 года назад

    Sar je banne ke liye bridge mein MCQ question daliye na sar netaon bridge ka manual daliye

  • @yashgupta6826
    @yashgupta6826 4 года назад

    Thanks Sir JI....
    GREAT SIR JI ....
    MORE VEDIO THIS TOPIC...

    • @success555
      @success555  4 года назад +1

      Welcome bro.
      Thanks for support.

  • @rohitrajbhar291
    @rohitrajbhar291 3 года назад +1

    Sir agar single span 10 metre ho aur total length 70 metre ho to usko Kya bolenge major bridge ya minor bridge ??
    Please reply sir

    • @success555
      @success555  3 года назад +1

      If total length more than 70 m , we have to design a major bridge.
      Then no one provide 10 m span, I crease the span length by providing RCC/PSC girders and reduce the number of pier.

    • @rohitrajbhar291
      @rohitrajbhar291 3 года назад

      Thank you sir

    • @success555
      @success555  3 года назад

      Welcome.
      Subscribe, like and share the video.

  • @SanjaySharma-ry5we
    @SanjaySharma-ry5we 3 года назад +5

    VUP: >5.5 Mtr; LVUP: 4 Mtr; PUP: 3 Mts.

    • @MySaisaran
      @MySaisaran 2 года назад

      Length of a vup?

    • @success555
      @success555  2 года назад

      Length Depend on site conditions.

  • @sanjeevkumar-iv7le
    @sanjeevkumar-iv7le 4 года назад +1

    Kyu aise video ko dislike karte ho yar... informative video hai support nai kar sakte to dislike bi mat karo pls ....

  • @tufealahmed30
    @tufealahmed30 2 года назад

    Sir mai aap ka ek video dekha jisme
    Box Culvert ka tha jis me quantity ka excel me tha p/s aap us video ka quantity ko explains kar ke ek video upload kare thoda samajne me problem ho raha hai

  • @Vijaykumar-mn2bx
    @Vijaykumar-mn2bx 3 года назад

    CUP,VUP,POP,WOP,VOP,WOP Bridge kya hote hai sir

    • @success555
      @success555  3 года назад

      Will make a video. Subscribe for more information.

  • @numanakhtar8519
    @numanakhtar8519 3 года назад

    Raiway ka bridge classification alag hota hai kya sir
    Waha 12 m span tha usko major bridge kahte the

    • @success555
      @success555  3 года назад

      Same for highways and Railways .

  • @musicverse9072
    @musicverse9072 3 года назад

    Sir ,SVUP ka use kya hai

    • @success555
      @success555  2 года назад

      Will upload a video soon.

  • @AftabAli0124
    @AftabAli0124 3 года назад

    Good sir👍

  • @The326178
    @The326178 3 года назад +1

    Pls mention VOP

  • @ashooupadhyay1452
    @ashooupadhyay1452 3 года назад

    Thankyou sir

  • @owais5703
    @owais5703 4 года назад +1

    Cup kya hota h

    • @success555
      @success555  4 года назад +1

      Cattle Under pass - for passing goat, sheep etc.,

    • @owais5703
      @owais5703 4 года назад

      Thanks sir

  • @arifkhan-pn4dn
    @arifkhan-pn4dn 4 года назад

    Kindly upload Design of flyover, Pup, Vup etc

    • @success555
      @success555  4 года назад

      OK brother.
      Thanks for support the channel.

  • @misbahulhakeem8358
    @misbahulhakeem8358 2 года назад +1

    Wonderful explanation 👍🏼

  • @angadyadav1351
    @angadyadav1351 3 года назад +1

    VUP kon sa ho h
    LVUP kon sa ho h

    • @success555
      @success555  2 года назад

      Vup 5.5 m vent clearance.

  • @ABHISHEKSINGH-qn2mp
    @ABHISHEKSINGH-qn2mp 3 года назад +1

    Causeway nahi bataye bahi

    • @success555
      @success555  3 года назад

      Will explain in another video.

  • @mohdnaghman3742
    @mohdnaghman3742 4 года назад

    Sir rob and rub and utility ka pic dikhaye

  • @Vijaykumar-mn2bx
    @Vijaykumar-mn2bx 3 года назад

    Sir is per video banao

  • @arpitpatel4245
    @arpitpatel4245 2 года назад

    Thumbnail mai 3:18 time dikha raha hai 😄

  • @sanojsharma7177
    @sanojsharma7177 4 года назад

    Sir, mere yaha rob Ka matlab railway over bridge, rub ka matlab railway under bridge bataya ja raha hai or drawing me bhi YAHI BATAYA JA RAHA HAI

    • @success555
      @success555  4 года назад +1

      Rob - road over bridge
      Means road bridge ke upper aayaga.
      Rail/train bridge ke niche jayaga.

  • @bikasmaurya5814
    @bikasmaurya5814 2 года назад

    Exal bhejiye sir

  • @innocentfriendsmarty1158
    @innocentfriendsmarty1158 2 года назад

    I need exel and drawing

  • @Gauravkumar-xr7ro
    @Gauravkumar-xr7ro 4 года назад

    MNB less 20m

  • @ashutoshmishra-zv2qu
    @ashutoshmishra-zv2qu 3 года назад

    SVUP full form

  • @youtubeevideos3998
    @youtubeevideos3998 3 года назад

    Plz send me major & minor brides excel sheets I will pay

  • @nagendrathakkar4601
    @nagendrathakkar4601 3 года назад

    avoid saying 'Thikh Hai' , it's very irritating and of no use
    concentrate on information