इस वीडियो से मेरे सारे सोलर के डाउट क्लियर हो गए थैंक यू वेरी मच सर आपने इस वीडियो को कोंबो पैक बना दिया सोलर के बारे मै ।।। सब्सक्राइब your channel ।।। मैं मार्च में सोलर लगाने वाला हूं
@@ZenInnovations if there is no such customization then do assit me to identify the buzzer basics. I mean to say that why the unit buzzer normally in the morning time
Nice video! Sir kya esme spv charging current 40A se kum kr ke 5A bhi set kr sakte hai? If yes this is the best inverter 1kwp ke 72cells ke panel lgaye 40Ah ki solar tubular battey lgaye Spv charging 5A pr set kre Poore din inverter pr 500-600w ka load easily chalaye Fir to ye appox "inverter without battery"¹1 k jaisa he ho gya jo aajkal jtyadatar bhot expansive and sub standard hote hai
@ 9:19 you were saying that by pressing 3 times will switch ON & OFF grid charging. I think that is not for grid charging, its for DG mode. Right? You can see 3 lines with gaps, means press 3 times with gap. The top line is continuous for 3 secs may be... I mean you need to hold that button without gap to enable or disable the grid charging. Am i right or wrong 🤔?
Video zen ji bohot aacha tha iss tarah ka detailed video chahiye tha love your teaching style ❤️👍👍👍but or ek request tha upp se last ka background music ka naam agar batate toh aacha hota🙏🙏🙏
Thank you for the informative video! Sir plz btaye ki Battery Equalizing (monthly) sirf Grid power se he hota hai lakin agar grid charging always off rakhe to bhi battery equalize hoti hai ya nahi?
Hi, I Need your help, I have a 24-volt UTL Gamma plus and the setup is brand new, and I think, there is something wrong with the UTL Gamma plus. I have set the Main reconnect volt c11V (22V for 24v system). but even before the battery reaches to reconnect volt it switches over to the Main. and usually with my system, when the battery reaches 24.5 it connects to the Main, the current mode setup to PCU, and grid charging is off. Any idea what could be the issue?
@@vishuvns gamma is known to be little over smart and try its own logic. Try moving reconnect voltage lower. Like 10.8v. You can also join my Telegram group from description.
Sir, I come across this channel recently.Thank you for the great informative videos. I have 24v 200ah battery(luminus iltt solar) and loom solar shark 440×2 pqnel with 24v gamma+ inverter. As explqined in the video for 12v battery, What will be the recommended advanced setting for 24v. Thanks
Dear Zen Innovations, This video recently helped me to guide my households to set the optimum values as you explained in this advanced calibration procedure. But I have one doubt - when we change the modes from HYB/SMT/PCU, will those settings disturbed or not?. Do we need to re-do the settings again in each mode or not?
Respected Sir, UTL Gama inverter copper winding he kya?, Aur mere pas exide flat plate non solar battery he wo is inverter pe kam me le sakata hu kya?, Jab ki mere ghar me main gird supply nahi he, me 5kw ka solar system lagay he.🙏
Sir aap kafi information achi date h... Sir ak question tha... Kya ham battery me ak ya 2 sal me 1250 grevti ka acid dal skte h kya... Meri battery ki grevti ban nhi rhi h.. 4... 5 din puri charging dane k bad b.. Battery thik h 3 sal huy h.. Ak bar battery se acid nikala tha... Or usme fir distal watar dala tha to uske bad ab grevti kam rahne lag gye h acid ki kami k karan... Kya m 1250 grevti ka acid dal skta hun kya... Jis se battery ki grevti charging k bad proper ho jay... Please tell me sir🙏
ruclips.net/video/3CrMlAB6dQA/видео.html You can add only if ACID was physically lost from the battery. Otherwise try equlizing- ruclips.net/video/LOcMRVRt_Wk/видео.html
Zen sir nexus solar panal or invater ka bhary m batieyga a utl say best hay ja add he hay 1 kw par day 7 uint bata rahy hay kha sai hay 1 kw utl katna uint par day deta hay
I have 12v 1KW gamma+ utl solar inverter and 1kw pannels, any idea ek saal mein kitne unit bijli (KWh) produce hogi?? 10 maheene se mera system working hai,700kwh show kar raha hai, is it the actual no of units or less than actual? Thanks in advance.
Hi,Sir I am currently using UTL Gamma Plus 12v with 200 AH C10 battery.Do I have to change any settings in advance calibration or default values will do fine?
Sir I have 2 Exide 150 Ah C10 battery connected in series to my UTL Gamma plus 24v . What would be the Amp setting, should I keep at 15 or 30 ? I have 3, 350 w panel connecte parallel. Pls advise
Hello sir I am always watching your video. I wants to know what is the minimum battery grid charging voltage on utl gama plus in your video you have shown it that is 14.4 but you have not shown how much down side we can maintaining this can helpful for poor battery condition. Hope you will reply.
Utl Gamma plus pe 165w ke 3 solar panel.hum series mei jod skde hai kya? Mere pass pehle 165w ke 2 hai maine wo series me jode hune hai matlb k 24volts bnya huya hai uska.
Thanks for the great tutorial. I have a question. In my place, load shedding is rare, so I don't want to invest in a large battery bank. My primary purpose will be to use solar power during the day. For that, I plan to install four 120 watts 12 volt panels (480 watts total). For emergency backup, I will install a small battery like a 100 AH battery. In that case, the solar charging current has to be set to 10 A. But my 480 watt panels are capable of delivering upto 40 A. Now my question is, how the inverter manages the 480 watt of solar power? Will it charge the battery at 10 A (that is 120 Watt) and use the rest 30 A (that is 360 watt) to convert to 230 V ? Or the charge controller will take only 10 A from solar panels without pushing anything to the inverter output. Here I am not using the gridline at all.
If you Brought a Proper PCU like the one above, Option 1 is valid. If its a dumb inverter with Charge controller, Option 2 will happen. I suggest you watch these videos for better understanding- ruclips.net/video/1YgmjAxIXvc/видео.html ruclips.net/video/R69XP5_Bvhc/видео.html ruclips.net/video/BqO87DVCWfs/видео.html
Sar UTI Gama plus 1 KVA mein kon si battery lagana best hai solar battery ya Lithium phosphate battery. kya Li Thi Ham phosphate battery Laga sakte hain
Kindly make a dedicated video on UTL Gamma plus sound notifications as there is no video on the internet on it. When on solar there are various sound notifications that the inverter gives.
I am setting up UTL gamma + 12V with 150ah 12V Solar Tubular single battery & 400W x 2 Solar panels in SMT mode. During calibration procedure should select 15V(boost) which is by default for TUB even if Boost Chg. disable ? Regarding watts of SPV what will be correct Amp range for charging battery which to choose between 11- 40Amp ? & what will be to select for charging battery from mains between 3 - 15Amp ? and charging frequency set to 60hz ? Finally set voltage reconnect range at 11.8 . Please provide recommend settings?
Ravsaheb Dighule Sr. Mere pass UTL gamma plus 12 madal 3panal 335 200AH meine lagai hai kya meri batrick dameej hogi kya Sr.ji mere solar inverter me ek problem aaya tha gritse charning kare to cooling fan nahi chalate the Or solar se chal rahe the to ye kya problem tha
मान्यवर नमस्कार। आप अच्छे जानकार हैं , बहुत अच्छे ढंग से समझाते हैं इसलिए आपको धन्यवाद। लेकिन क्षमा चाहता हूं आपसे कहना चाहता हूं कि आपने एक सामान्य उपभोक्ता को समझाया नहीं केवल उलझाया है। आप सोलर एक्सपर्ट हैं आप दिनभर बर्तनों से खेल सकते हैं लेकिन एक सामान्य परिवार में इनवर्टर लगाने के बाद कोई बार-बार बटन से ट ऑन ऑफ नहीं करता है। जैसा कि आप जानते ही हैं कि इस इनवर्टर में सामान्यया एक बैटरी ही प्रयोग की जाती है तो यह निश्चित है कि शाम को इसका बैकअप आपको greed से लेना ही पड़ेगा। उचित रहेगा कि आप इसमें ऐसी सेटिंग बताएं कि दिन में सोलर से एवं रात्रि में स्वयमेव ऑटोमेटिक आवश्यकताअनुसार grid पर चला जाए।
If i have 1kw solar system with two 150 ah batteries and if i have default 18 ampere spv setting then solar power get wasted? Do i need to set it at 30 ampere due to two batteries?
I have a gamma plus 1kilo inverter...with 2 batteries of 150tubler solar battery (excide company)...I also have 1350 watt solar panels of microtek n luminous.plain 10mm copper AC wire length-15mtr load in summer-500watt & But don't give 24hrs backups....why it's not giving backup for full day???can u explain me the reason......please...gopal samanta from barrackpore.......
Naturally it wont, your Load is Roughly 50A, which will consume your 300A battery bank under 6 hours. More like 4 hours practically. I have explained load calculations here- ruclips.net/video/RRwYBgUz9lg/видео.html
Nice video sir I have an question as follows If i have disabled grid charging and my battery discharged at night to reconnect voltage that is 11.8v will it charge battery by grid?
Sir i have an another question If DG mode on will it charge battery from mains if DG source is unavailable? Is there any problem if i enable DG mode always even if mains present as sometimes i turn on generator
@@jayanarayan DG mode just lowers the tolerance and allows a wider frequency to charge the battery. You can keep it On if you don't have any sensitive appliances connected.
Kya agar ham parallel me c10 ka 200ah two battery agar iske saath connect karte hai tab ham solar ka ampere 40 rakta hu to kya grid ka bhi 40 kar sakta hu?? Kyoki 1 battery 20amp se charge hota hai tab 2 battry 40amp required hota hai.
Mera freeze auto cut h jab cut k baad again start hota h to ups se jo aur light jalti h to unki light jada kam( low and high) hoti h 1 sec k liye ... aisa kyu....
@@ZenInnovations sir piche solar card me problem ho gyi thi to engineer aaye the tan unse bola tha ki output badha do lekin unhone kosis bhi kri lekin volt badha na paye to ab aap batao ki kya kare?
Hello I have C10 solar tubular battery 150 ah 12 V single battery. Can I set all your recommend voltage ? Why is battery charging current through solar is set to 39.2 Amp ? Is it not better to be lower between 11 - 20 Amp ? As I commented here before that I used 400 W x 2 solar panels.
Sir, good evening. My utl gamma plus 1kva12 volt pcu low cut voltage setting is 11 volt, but when battery voltage is going to 11.8 volt then pcu shows low voltage and beep sound arise. Please note that My pcu is in SMT mode and mains unavailable.
Good video all the best. Sir i have a problen in utl gama plus 1 kv 12 v that is after solar stop it is not take load from battery in PCU mode why and how to rectify it. And this take the load from main only after i switched off the main switch it is taking load from battery. It is not automatically change over to battery. please help
Sir ager me 220ah ki tubular battery ko 30 ampier (solar power) se charge kru to koi problem to nhi hogi, jis se ki battery jaldi charge ho jaye. Please reply me...
Sir, Finally mene solar system lagaya ghar me, 190w loom solar ke 3 panel, utl gama plus 12v inverter, 150ah battery, thank you Sir apke video bohot kuch sikhati he
hello sir mare pass same model ha nd mane 2 150ah ki batteries ka series connection kiya hua ha. or main PCU mode main chla raha hun lakin mera system 25.5 pe he main se eletrcity use krna start kr deta ha. jb ki low ka cutout 23.8 ha iska koi solution ha ki jb tk voltage 23.8 nahi aa jata tab tk battry he use kre
Sir ye inverter 10 amp sai Kum charge nhi kar skta h kya ...jaise is inverter mai hum 150 ah ki c20 battery laga de usme charging amp 7.5 amp sai battery charge hoti h .10 amp sai kahi battery kharab to nhi hogi ..mere pass c20 battery h ye inverter lene wala hun
Sir mere pass 1kv12v ka gaama plus system hai or 12v ke 180watts ke 2 mono panel hai in ka parell mai ya series mai better' result aaega or mai naya panels purchase karna chahta hu 165wats ke 2 poly lu ya 330watts 24v ka ek poly koun sa better rahe ga mono or poly different hone par output koi effect to nhi pade ga Or mai din din mai load solar se chanana chahta hu or raat ko battery bhi store chahta hu ta ki night mai battery Store mil jae light na hune par kaam chal jae or load grid se night mai chalta rhe Or light na hune par night mai battery se bhi kaam chal jae or subha phir load solar par chal jae is ke liye koun sa mode thik rahe ga ji hybrid smart pcu aap ka video bhi dekha par khuch samjh nhi gaya plz sir guide me battery ki life bhi thik rahe din ka load ek fan or ek cooler hai
Hello sir...I have 2kb gamma plussolar ups n 1750watt of solar panels(mixed panels of small of 100watt n big of 165watt& 1panel of 350watt)...2batteries of 150hp are connected in series..can I connect one more 150hp battery in parallel????it's a Lil urgent...if u give ur response I will be highly obliged...
Sir inverter pcu mode pr hai. night mai vo kabhi battary pr jara kabhi main pr aysa thodi thodi time pr hota hai kya reason hoga, sound aate rheta , neend disturb hoti hai.
sir mere pass utl gamma plus 1 kv ka soler inverter hai , main 165 watt 12 volt ke 4 panel lagaye hai par main aur 1 panel 340 watt 24 volt ka ek sath laga sakta hu
Isme koi aisi setting bhi h kya jisse sham k time smart mode se hybrid mode me automatically switch kar jaye ya fir tab kare jab solar ka generation load se kam ho kyonki mere ghr pe sham ko 6PM k bad jab solar power kam ho jati h load se tab ye battery se consume karta h or battery 50% pe aa jati h sam ko mane grid charging off kar rakhi h
@@ZenInnovations smart mode mai charging 24hour on hi rakhni hai kya ta ki din mai load solar se chalta rhe or raat ko battery bhi charge rhe or load bhi Direct grid se chale
Sir mere pass utl gamma plus h or us par 330 v ki 3 palet lagi h ghar me us se sirf 3 camare or ek display or ek LED balb laga h or mane off kar ke ghar se bahar tha . 3 mahine bad dya to battery ka pani kisi me tha or kisi me nhi or bettery garam bhi ho rhi thi . Aab mene uske 2 palet se connection hata diya ha or mean off kar ke chala gya hu . To rat me camare kabhi 2 kabhi 3 baje band ho jate h or subah dhup aane par chalne lagte h to kya kiya jay 2 palete jod de kya halp me plz 🙏
Sir mere pas 180 watt ka 6 panel hai 9 amp each panel amp hai max sir 6 panel ko parallel connection ker sakte hai jisme max amp 54 amp a sakta hai kyu ki do panel series connection kerne per voc 46.26 volt ho jata hai please batia sir Thankyou
Bro 2 doubt Doubt 1 1. I have 180w panel (12v) no1 2. 200w panel (12v) no 2 3. 205w panel (12v) no 2 So total 990w (can I connect this all panel in parellel) Doubt 2( i have utl Gamma plus 12v 1kw solar inverter) Is it possible to connect 2 battery in parellel?
Your question has been answered in QNA EP19 ! Click the below link to Join Premiere (live). This video is scheduled to go public for its Premiere on February 23, 8:00 PM . Set the Reminders! Hit Likes by the time! ruclips.net/video/eYYAeYWGZX8/видео.html You can also participate in live chat session. After the Premiere is done, you can also watch it as a normal video.
नीचे दिए गए डिटेल्स का 3 सोलर पैनलमेरे पास है, तो मुझे UTL का 1KV 12 वोल्ट वाला इन्वर्टर लेना चाहिए या नहीं ? 1 plate ka capacity. Maximum power (pmax)- 300 Wp Rated current (Impp)- 8.39 A Rated voltage (Vmpp)- 35.76 V Short circuit current (Isc)- 8.86 A Max system voltage - 1000 VDC (TUV) Series fuse rating - 15 A
Mere pass heliac 1200 he. Usme calibration me charging amp me grid ka he but spv ka nahi show kar raha he. Aesa kyo? To kya ye solar se charging nhi kar pata.
utl gamma plus 12 volt 1 kva inverter के साथ 750 watt 24 volt poly solar panel set-up मे maximum कित्ना एम्पियर current आना चहिए ? uttam khadgi from nepal
wow.. great video.... best detailed explanation for the best 1 Kva inverter available in current market. lots of love
Thanks a ton SC !
इस वीडियो से मेरे सारे सोलर के डाउट क्लियर हो गए थैंक यू वेरी मच सर आपने इस वीडियो को कोंबो पैक बना दिया सोलर के बारे मै ।।। सब्सक्राइब your channel ।।। मैं मार्च में सोलर लगाने वाला हूं
You're Very much welcome Pankaj ji!
Nobody can explain like you...everything cleared.. I have seen More than 5 times...
Glad you are liking it Prashant !
We have recently purchase the Gamma Plus 12.
Your videos really helped us.
Request you to kindly prepare a fresh video on Buzzer Notification
Thanks.
@@ZenInnovations you need to consider making a video on buzzer notification which will actually identify the various signs of buzzer in the Gamma plus
@@RamRane-do7ue there is no such customization
@@ZenInnovations if there is no such customization then do assit me to identify the buzzer basics. I mean to say that why the unit buzzer normally in the morning time
Nice video!
Sir kya esme spv charging current 40A se kum kr ke 5A bhi set kr sakte hai?
If yes this is the best inverter
1kwp ke 72cells ke panel lgaye
40Ah ki solar tubular battey lgaye
Spv charging 5A pr set kre
Poore din inverter pr 500-600w ka load easily chalaye
Fir to ye appox "inverter without battery"¹1 k jaisa he ho gya jo aajkal jtyadatar bhot expansive and sub standard hote hai
ruclips.net/video/-9ssKLZwJfw/видео.html
Its called as dost setup.
This was a really very very helpful video.. pura settings clear ho gaya ..
🙂
Welcome
बहुत बढीया जानकारी @ very nice you are great
You're welcome!!
@ 9:19 you were saying that by pressing 3 times will switch ON & OFF grid charging. I think that is not for grid charging, its for DG mode. Right? You can see 3 lines with gaps, means press 3 times with gap. The top line is continuous for 3 secs may be... I mean you need to hold that button without gap to enable or disable the grid charging. Am i right or wrong 🤔?
The symbol of 3 lines with gaps shows that LED will blink in that manner for DG mode.
The button behavior I have explained is correct.
@@ZenInnovations anyway thank you. Your videos are great 😍. Thats y i am keep on watching 👍
@@rajeevimar8715 Sure & Welcome.
I AM wating for this video last 1 year👍👍
Enjoy
Video zen ji bohot aacha tha iss tarah ka detailed video chahiye tha love your teaching style ❤️👍👍👍but or ek request tha upp se last ka background music ka naam agar batate toh aacha hota🙏🙏🙏
You're welcome Dip Ji.
The Music is from RUclips Library.
@@ZenInnovations what's the name of this music?
@@dipelectricalselectronics230 I think Blue macaw
@@ZenInnovations ok sir thanks a lot 😊😊
Very nice informative video Zen ji 🙏💐
Thanks a lot Pathak ji
Utll gama plus 12v inverter pe Restor factory ka koi function hai yea néhi ?
We have to press it mode and smf/tub battery button continuously then it will set to factory defaults
Thank you for the informative video!
Sir plz btaye ki Battery Equalizing (monthly) sirf Grid power se he hota hai lakin agar grid charging always off rakhe to bhi battery equalize hoti hai ya nahi?
You can manually equalize from solar by using slightly higher charging voltages..
@@ZenInnovations many thanks
Bahuth badiya video..... Superb
Welcome Prasanth!
Hi, I Need your help, I have a 24-volt UTL Gamma plus and the setup is brand new, and I think, there is something wrong with the UTL Gamma plus. I have set the Main reconnect volt c11V (22V for 24v system). but even before the battery reaches to reconnect volt it switches over to the Main. and usually with my system, when the battery reaches 24.5 it connects to the Main, the current mode setup to PCU, and grid charging is off. Any idea what could be the issue?
Get the software or motherboard card updated to latest version by customer care. It should be covered in warranty.
@@ZenInnovations this is new one tub/lithium model. Do you think it having an issue or any settings need to try?
@@vishuvns gamma is known to be little over smart and try its own logic. Try moving reconnect voltage lower. Like 10.8v.
You can also join my Telegram group from description.
@@ZenInnovations the minimum is 11v
then better contact service center
Excellent illustration.. 😊
Thank you so much 😀
Very informative video. 🤓🤓🤓
Glad you liked it TechZonical !
Sir,
I come across this channel recently.Thank you for the great informative videos.
I have 24v 200ah battery(luminus iltt solar) and loom solar shark 440×2 pqnel with 24v gamma+ inverter. As explqined in the video for 12v battery, What will be the recommended advanced setting for 24v. Thanks
Just that voltage will be Double. Rest is the same. Explained in further details here-
ruclips.net/video/1RMkdRQ1vg4/видео.html
can u please explain something about Utl gamma 2kva 24v???
Sure. On my New channel Zen home.
Dear Zen Innovations, This video recently helped me to guide my households to set the optimum values as you explained in this advanced calibration procedure. But I have one doubt - when we change the modes from HYB/SMT/PCU, will those settings disturbed or not?. Do we need to re-do the settings again in each mode or not?
I believe the calibration does not reset. Still you can ensure by entering the menu once...
Does pressing power button off of solar utl necessary while closing shop ? Does after it still charges in morning?
Not necessary
Respected Sir,
UTL Gama inverter copper winding he kya?, Aur mere pas exide flat plate non solar battery he wo is inverter pe kam me le sakata hu kya?, Jab ki mere ghar me main gird supply nahi he, me 5kw ka solar system lagay he.🙏
1. UTL has not clarified. I assume its Aluminium
2. Any Lead acid battery will work.
thank you sir
Sir aap kafi information achi date h... Sir ak question tha... Kya ham battery me ak ya 2 sal me 1250 grevti ka acid dal skte h kya... Meri battery ki grevti ban nhi rhi h.. 4... 5 din puri charging dane k bad b.. Battery thik h 3 sal huy h.. Ak bar battery se acid nikala tha... Or usme fir distal watar dala tha to uske bad ab grevti kam rahne lag gye h acid ki kami k karan... Kya m 1250 grevti ka acid dal skta hun kya... Jis se battery ki grevti charging k bad proper ho jay... Please tell me sir🙏
ruclips.net/video/3CrMlAB6dQA/видео.html
You can add only if ACID was physically lost from the battery. Otherwise try equlizing-
ruclips.net/video/LOcMRVRt_Wk/видео.html
@@ZenInnovations thanku sir....
Zen sir nexus solar panal or invater ka bhary m batieyga a utl say best hay ja add he hay 1 kw par day 7 uint bata rahy hay kha sai hay 1 kw utl katna uint par day deta hay
Many members on my Telegram group are using Nexus. You can ask.
7 units bhaut mushkil hai.
Does solar utl count units if devices used directly from solar without recharging battery?
yes
Aap ne koun se panel lagae h jo 24-27amp output de raha h jo ki singal battery ke liye bahut h day and night time
ruclips.net/video/_KDDVLtq3Pk/видео.html
I have 12v 1KW gamma+ utl solar inverter and 1kw pannels, any idea ek saal mein kitne unit bijli (KWh) produce hogi??
10 maheene se mera system working hai,700kwh show kar raha hai, is it the actual no of units or less than actual?
Thanks in advance.
I have made many videos on this.
Reading depends on Month, Load and so on
You can check them in Solar energy Playlist.
Hi,Sir I am currently using UTL Gamma Plus 12v with 200 AH C10 battery.Do I have to change any settings in advance calibration or default values will do fine?
Its better to go over calibration once.
Sir I have 2 Exide 150 Ah C10 battery connected in series to my UTL Gamma plus 24v . What would be the Amp setting, should I keep at 15 or 30 ? I have 3, 350 w panel connecte parallel. Pls advise
ruclips.net/video/1RMkdRQ1vg4/видео.html
Hello sir I am always watching your video. I wants to know what is the minimum battery grid charging voltage on utl gama plus in your video you have shown it that is 14.4 but you have not shown how much down side we can maintaining this can helpful for poor battery condition. Hope you will reply.
I will have to check...
Awesome job... Zen ji for 👍👍👍
Many thanks DK.
Utl Gamma plus pe 165w ke 3 solar panel.hum series mei jod skde hai kya? Mere pass pehle 165w ke 2 hai maine wo series me jode hune hai matlb k 24volts bnya huya hai uska.
ruclips.net/video/mwlnr2O9K3Q/видео.html
@@ZenInnovations thank you sir maine sirf apka channel dekha hai. Jo 100% reply karta hai.
Thanks for the great tutorial. I have a question. In my place, load shedding is rare, so I don't want to invest in a large battery bank. My primary purpose will be to use solar power during the day. For that, I plan to install four 120 watts 12 volt panels (480 watts total). For emergency backup, I will install a small battery like a 100 AH battery. In that case, the solar charging current has to be set to 10 A. But my 480 watt panels are capable of delivering upto 40 A. Now my question is, how the inverter manages the 480 watt of solar power? Will it charge the battery at 10 A (that is 120 Watt) and use the rest 30 A (that is 360 watt) to convert to 230 V ? Or the charge controller will take only 10 A from solar panels without pushing anything to the inverter output. Here I am not using the gridline at all.
If you Brought a Proper PCU like the one above, Option 1 is valid.
If its a dumb inverter with Charge controller, Option 2 will happen.
I suggest you watch these videos for better understanding-
ruclips.net/video/1YgmjAxIXvc/видео.html
ruclips.net/video/R69XP5_Bvhc/видео.html
ruclips.net/video/BqO87DVCWfs/видео.html
Sir low batteru ke voltage kitne sahi hai? 10.5v rakh sakte hai?
10.5 is rock bottom. 11 or 11.2 should be fine.
Sar UTI Gama plus 1 KVA mein kon si battery lagana best hai solar battery ya Lithium phosphate battery. kya Li Thi Ham phosphate battery Laga sakte hain
Solar Battery amzn.to/3yM6cTb
Kindly make a dedicated video on UTL Gamma plus sound notifications as there is no video on the internet on it.
When on solar there are various sound notifications that the inverter gives.
Ok
I am setting up UTL gamma + 12V with 150ah 12V Solar Tubular single battery & 400W x 2 Solar panels in SMT mode. During calibration procedure should select 15V(boost) which is by default for TUB even if Boost Chg. disable ? Regarding watts of SPV what will be correct Amp range for charging battery which to choose between 11- 40Amp ? & what will be to select for charging battery from mains between 3 - 15Amp ? and charging frequency set to 60hz ? Finally set voltage reconnect range at 11.8 . Please provide recommend settings?
Watch the video carefully. Everything is explained.
@@ZenInnovations ok
Ravsaheb Dighule
Sr. Mere pass UTL gamma plus 12 madal
3panal 335
200AH meine lagai hai kya meri batrick dameej hogi kya
Sr.ji mere solar inverter me ek problem aaya tha gritse charning kare to cooling fan nahi chalate the
Or solar se chal rahe the to ye kya problem tha
Contact service center.
Thank you 🙏 sr ji
मान्यवर नमस्कार। आप अच्छे जानकार हैं , बहुत अच्छे ढंग से समझाते हैं इसलिए आपको धन्यवाद। लेकिन क्षमा चाहता हूं आपसे कहना चाहता हूं कि आपने एक सामान्य उपभोक्ता को समझाया नहीं केवल उलझाया है। आप सोलर एक्सपर्ट हैं आप दिनभर बर्तनों से खेल सकते हैं लेकिन एक सामान्य परिवार में इनवर्टर लगाने के बाद कोई बार-बार बटन से ट ऑन ऑफ नहीं करता है। जैसा कि आप जानते ही हैं कि इस इनवर्टर में सामान्यया एक बैटरी ही प्रयोग की जाती है तो यह निश्चित है कि शाम को इसका बैकअप आपको greed से लेना ही पड़ेगा। उचित रहेगा कि आप इसमें ऐसी सेटिंग बताएं कि दिन में सोलर से एवं रात्रि में स्वयमेव ऑटोमेटिक आवश्यकताअनुसार grid पर चला जाए।
That was discussed here-
ruclips.net/video/KO166qGxaWQ/видео.html
This problem of pcu or settings problem? Please help.
If i have 1kw solar system with two 150 ah batteries and if i have default 18 ampere spv setting then solar power get wasted? Do i need to set it at 30 ampere due to two batteries?
ruclips.net/video/1RMkdRQ1vg4/видео.html
Sir utl gamma plus se ek bar agar battery ki gravity uthana ho to kaun si setting kare
Go to TUB mode and then set battery bulk charging voltage to 14.8v. Let the batteries charge properly.
I have a gamma plus 1kilo inverter...with 2 batteries of 150tubler solar battery (excide company)...I also have 1350 watt solar panels of microtek n luminous.plain 10mm copper AC wire length-15mtr load in summer-500watt & But don't give 24hrs backups....why it's not giving backup for full day???can u explain me the reason......please...gopal samanta from barrackpore.......
Naturally it wont, your Load is Roughly 50A, which will consume your 300A battery bank under 6 hours. More like 4 hours practically. I have explained load calculations here-
ruclips.net/video/RRwYBgUz9lg/видео.html
Nice video sir
I have an question as follows
If i have disabled grid charging and my battery discharged at night to reconnect voltage that is 11.8v will it charge battery by grid?
No. It will simply run load by grid.
@@ZenInnovations thank u so much
Sir i have an another question
If DG mode on will it charge battery from mains if DG source is unavailable?
Is there any problem if i enable DG mode always even if mains present as sometimes i turn on generator
@@jayanarayan DG mode just lowers the tolerance and allows a wider frequency to charge the battery. You can keep it On if you don't have any sensitive appliances connected.
@@ZenInnovations thanks alot sir,😀😀😀
URL gamma 12 volt inverter me 24 volt panel lga sakte hai kya
ruclips.net/video/Prm9R6jUafg/видео.html
Video dekhe hai Samjh nahi aaya hai sir aap bta lagega ki nahi
@@rockstareventdeoria 12v Inverter Support karega max 45 VOC panel.
Thanku
Kya agar ham parallel me c10 ka 200ah two battery agar iske saath connect karte hai tab ham solar ka ampere 40 rakta hu to kya grid ka bhi 40 kar sakta hu?? Kyoki 1 battery 20amp se charge hota hai tab 2 battry 40amp required hota hai.
Grid 40 tak nahi jayega. Max 15 ka setting hai.
best explanation bhai.
Thanks Dinesh.
Mera freeze auto cut h jab cut k baad again start hota h to ups se jo aur light jalti h to unki light jada kam( low and high) hoti h 1 sec k liye ... aisa kyu....
ruclips.net/video/X5-3Xs_eghY/видео.html
Thanx
Sir Utl Heliac 3000 model hai 24v me Uska Output 219v hai 235v output krni hai kaise kare??
Contact service center
@@ZenInnovations sir piche solar card me problem ho gyi thi to engineer aaye the tan unse bola tha ki output badha do lekin unhone kosis bhi kri lekin volt badha na paye to ab aap batao ki kya kare?
Hello I have C10 solar tubular battery 150 ah 12 V single battery. Can I set all your recommend voltage ? Why is battery charging current through solar is set to 39.2 Amp ? Is it not better to be lower between 11 - 20 Amp ? As I commented here before that I used 400 W x 2 solar panels.
Because mine is special setup using very large battery bank.
ruclips.net/video/_KDDVLtq3Pk/видео.html
@@ZenInnovations yeah I understand it and regarding my set up I selected 15.0 Amp but battery reconnect voltage is keep at 11.8 default. Thanks
Sir,
good evening. My utl gamma plus 1kva12 volt pcu low cut voltage setting is 11 volt, but when battery voltage is going to 11.8 volt then pcu shows low voltage and beep sound arise. Please note that My pcu is in SMT mode and mains unavailable.
Gamma motherboards are known to have some calibration inaccuracies. Many people have gotten those cards replaced in warranty.
Very nice knowledge
So nice of you
Good video all the best.
Sir i have a problen in utl gama plus 1 kv 12 v that is after solar stop it is not take load from battery in PCU mode why and how to rectify it. And this take the load from main only after i switched off the main switch it is taking load from battery. It is not automatically change over to battery. please help
Try resetting & calibrating again
@@ZenInnovations thank u
I have 1kva 12 v Utl gamma plus solar inverter...can I connect this with 2 batteries with 150hp....???please suggest
ruclips.net/video/82WY-aM7PvY/видео.html
Sir ager me 220ah ki tubular battery ko 30 ampier (solar power) se charge kru to koi problem to nhi hogi, jis se ki battery jaldi charge ho jaye.
Please reply me...
ruclips.net/video/1RMkdRQ1vg4/видео.html
Is inverter ke saath 150ah ke 2 batteries parallel mai connect ke baad kya settings kren .. pls reply.
Same. Just amps double.
@@ZenInnovations thanks 🥰
Smashing ! Rocking video !
Wow.
Excellent Explain 👏👌👍🙏
Thank you so much 🙂
@@ZenInnovations You are welcome
Sir, mere ghar me mseb light nahi he, me 24×7 solar pe depend hu. Usake liye. Utl gama ki setting kya hogi??
Settings will be same as above. Use a large battery bank.
Thank you sir
Sir, Finally mene solar system lagaya ghar me,
190w loom solar ke 3 panel, utl gama plus 12v inverter, 150ah battery, thank you Sir apke video bohot kuch sikhati he
hello sir mare pass same model ha nd mane 2 150ah ki batteries ka series connection kiya hua ha. or main PCU mode main chla raha hun lakin mera system 25.5 pe he main se eletrcity use krna start kr deta ha.
jb ki low ka cutout 23.8 ha iska koi solution ha ki jb tk voltage 23.8 nahi aa jata tab tk battry he use kre
Gamma is known to be inaccurate. If it's in warranty, get the motherboard replaced to latest version. It fixes many problems.
Sir, i have seen a video on RUclips, saying that utl gamma plus 24v have the capability to run on 1 battery also. Is it correct?
No. There are too many foolish youtubers around.
Sir can we connect 330 watt panel it’s VOC is 46.5 ?????bcz inverter support 45 voc ….so pls guide me sir .
You can connect at your own risk.
Grid charging off ho to kya reconnect mode pe set volt pe aate hi kya wo grid se connect ho jayega load jo inverter pe h ....
Yes.
Good morning Sir. Is there any 12V inverter with VOC 100V
No, but there are charge controllers like-
ruclips.net/video/hLxL3FBOBkY/видео.html
@@ZenInnovations thanks sir
Sir, my gamma plus has show zero solar amps but showing sufficient volta in even sunny day.
Need your suggestion to over come from this problem
Contact service center
@@ZenInnovations call many times but no revert from their side.
@@Bapon9 send written complaints.
Kya 24 volt wala UTLgamma + ko hum ek 200ah k battery pe laga sakte hai ?
No, As Explained here-
ruclips.net/video/mwlnr2O9K3Q/видео.html
@@ZenInnovations Dhanyawad sahab G .
@@bhimbahadurthapa7165 You're welcome.
Sir ye inverter 10 amp sai Kum charge nhi kar skta h kya ...jaise is inverter mai hum 150 ah ki c20 battery laga de usme charging amp 7.5 amp sai battery charge hoti h .10 amp sai kahi battery kharab to nhi hogi ..mere pass c20 battery h ye inverter lene wala hun
Bhai ismein aap 150 empier ki do battery Laga sakte hain,, parallel mein series mein nahin Laga sakte
DG mode se kea battery charge hoga? ya Supply bypass ho jayega?
ruclips.net/video/eYYAeYWGZX8/видео.html
Nice explaing
Welcome.
My utl gamma shows spv current 41a, spv 22.5v, but I have 360 w 12v panel. Please suggest how to correct it.
Contact Service center.
Sir mere pas utl heliac 12volt ka inverter hai, kya main isme 14volte ka battery laga sakta ho pls batay
Use solar battery like this one amzn.to/3OO6OPj
@@ZenInnovations mere pas dry cell battery hai 2volt ka 7 . To series mea 14 volte hoga use krna hai inverter pe
@@sujay6460 use 6 cells.
@@ZenInnovations sir muje bhi pata hai 6 par 7 cell use hoga sir
@@sujay6460 7 won't work.
Hamare inverter ki display me light nahi aa rahi hai or hamre pas ak choti solar hai kya ham usko charging me use kr skate hai
Sir mere pass 1kv12v ka gaama plus system hai or 12v ke 180watts ke 2 mono panel hai in ka parell mai ya series mai better' result aaega or mai naya panels purchase karna chahta hu 165wats ke 2 poly lu ya 330watts 24v ka ek poly koun sa better rahe ga mono or poly different hone par output koi effect to nhi pade ga
Or mai din din mai load solar se chanana chahta hu or raat ko battery bhi store chahta hu ta ki night mai battery Store mil jae light na hune par kaam chal jae or load grid se night mai chalta rhe Or light na hune par night mai battery se bhi kaam chal jae or subha phir load solar par chal jae is ke liye koun sa mode thik rahe ga ji hybrid smart pcu aap ka video bhi dekha par khuch samjh nhi gaya plz sir guide me battery ki life bhi thik rahe din ka load ek fan or ek cooler hai
Pls watch QNA EP1 & 2.
Hlw Sir.. Main Bangladesh se hu.. Ek problem huya hain yeh kis liye horahi hain?? E8v
Pls contact service center
Sir 100 waat k 2 paniles ko sereg k sath 335 waat 24 v k paniles laga sakte he
No.
Very informative video ✌️
Glad you liked it
Great for your service best regards
Thanks a lot!
Ye inverter bina Solar System k laga sakte h Normal battery p?
Easily
Hello sir...I have 2kb gamma plussolar ups n 1750watt of solar panels(mixed panels of small of 100watt n big of 165watt& 1panel of 350watt)...2batteries of 150hp are connected in series..can I connect one more 150hp battery in parallel????it's a Lil urgent...if u give ur response I will be highly obliged...
You can connect 4 batteries to 24v system like this-
ruclips.net/video/Wrdm2wvIK9k/видео.html
@@ZenInnovations sorry sir ..I have gamma solar ups ...in that case is that same that I can connect one more battery in parralel?
Pls watch That video carefully. I have explained the connection diagram.
Ask any solar technician to help you with proper wiring.
Sir, kiya is ki output voltage 220 ko 230 ya 240 kar saktain hayn. If yes then how please explain deeply.
Cannot be done by user.
Sir inverter pcu mode pr hai. night mai vo kabhi battary pr jara kabhi main pr aysa thodi thodi time pr hota hai kya reason hoga, sound aate rheta , neend disturb hoti hai.
Contact service center
सर utl हेलिक की pcu सेटिंग एडवांस्ड कॉलिब्रेशन का वीडियो बना दीजिये ।।
sir mere pass utl gamma plus 1 kv ka soler inverter hai , main 165 watt 12 volt ke 4 panel lagaye hai par main aur 1 panel 340 watt 24 volt ka ek sath laga sakta hu
12 volt aur 24 volt dono 1 sath kar sakte hai kya gamma plus 1 kv ka
Mixed panels have been discussed here-
ruclips.net/video/T_s7uQ2JJF4/видео.html
ruclips.net/video/_i1C4Y6Hi5I/видео.html
Isme koi aisi setting bhi h kya jisse sham k time smart mode se hybrid mode me automatically switch kar jaye ya fir tab kare jab solar ka generation load se kam ho kyonki mere ghr pe sham ko 6PM k bad jab solar power kam ho jati h load se tab ye battery se consume karta h or battery 50% pe aa jati h sam ko mane grid charging off kar rakhi h
Just set the modes properly-
ruclips.net/video/KO166qGxaWQ/видео.html
You can use SMT mode.
@@ZenInnovations smart mode mai charging 24hour on hi rakhni hai kya ta ki din mai load solar se chalta rhe or raat ko battery bhi charge rhe or load bhi Direct grid se chale
@@indiastalent3937 depends on your needs. I keep grid charging always off.
Sir Is this possible to feed load from solar and grid together?
ruclips.net/video/_i1C4Y6Hi5I/видео.html
Where can get utl gamaplus12v solar inverter in Sitamarhi bihar?
You can buy online-
amzn.to/2ZteCg9
amzn.to/2BWMg5N
amzn.to/2NPuSCE
Sir gama + se Beatty ko minimum kitne amp se charge kar skte hai
I think 11 from solar, 3A from Grid.
Sir mere pass utl gamma plus h or us par 330 v ki 3 palet lagi h ghar me us se sirf 3 camare or ek display or ek LED balb laga h or mane off kar ke ghar se bahar tha . 3 mahine bad dya to battery ka pani kisi me tha or kisi me nhi or bettery garam bhi ho rhi thi . Aab mene uske 2 palet se connection hata diya ha or mean off kar ke chala gya hu . To rat me camare kabhi 2 kabhi 3 baje band ho jate h or subah dhup aane par chalne lagte h to kya kiya jay 2 palete jod de kya halp me plz 🙏
Very informative video thanks sir...
You're welcome
@@ZenInnovations sir please guide about total minimum expenses...
@@mangeshbhatkar3189 expenses depends on what components you Buy.
You can check prices using buying links in the description.
@@ZenInnovations iam telling about UTL Gamma plus 1kv solar inverter setup....(inverter/solar battery/panel/setup)
Yes. You can also Join my Telegram group for latest prices.
Sir mere UTL gamma me E5 alarm dikata hai hai kya problem hai setting ki problem hai yaa koi orr maine abhi panel nhi lagaye hai only grid pr hai
contact service center.
Very useful video. Thank u
So nice of you Abhishek !
Sir mere pas 180 watt ka 6 panel hai 9 amp each panel amp hai max sir 6 panel ko parallel connection ker sakte hai jisme max amp 54 amp a sakta hai kyu ki do panel series connection kerne per voc 46.26 volt ho jata hai please batia sir Thankyou
You can put them in Parallel no issues. Use a Very thick wire. 16Sqmm,
Bro 2 doubt
Doubt 1
1. I have 180w panel (12v) no1
2. 200w panel (12v) no 2
3. 205w panel (12v) no 2
So total 990w (can I connect this all panel in parellel)
Doubt 2( i have utl Gamma plus 12v 1kw solar inverter)
Is it possible to connect 2 battery in parellel?
Depends on voltage & specs of panels. Watch
ruclips.net/video/_i1C4Y6Hi5I/видео.html
Parallel battery ruclips.net/video/sQuzJP5CSAg/видео.html
Sir battery heat kuy hoti ha please suggest me 150ah battery ha humari utl gamma plus Inverter ha
Your question has been answered in QNA EP19 !
Click the below link to Join Premiere (live). This video is scheduled to go public for its Premiere on February 23, 8:00 PM . Set the Reminders! Hit Likes by the time!
ruclips.net/video/eYYAeYWGZX8/видео.html
You can also participate in live chat session. After the Premiere is done, you can also watch it as a normal video.
नीचे दिए गए डिटेल्स का 3 सोलर पैनलमेरे पास है, तो मुझे UTL का 1KV 12 वोल्ट वाला इन्वर्टर लेना चाहिए या नहीं ?
1 plate ka capacity.
Maximum power (pmax)- 300 Wp
Rated current (Impp)- 8.39 A
Rated voltage (Vmpp)- 35.76 V
Short circuit current (Isc)- 8.86 A
Max system voltage - 1000 VDC (TUV)
Series fuse rating - 15 A
You can buy.
@@ZenInnovations तीनो पैनेल को कैसे कनेक्शन करना है पैरलल या सिरीज में ?
Can you please share your WhatsApp number
@@chandrashekharkumar3416 naturally parallel hi hoga.
@@chandrashekharkumar3416 teenon panel ko parallel mein connect karo bhai series mein nahin
Does advanced calibration work in smart mode?
It's for all the modes.
I have solar 40ah battery I need ac to charge laptop so which inveter shall I buy?
Its better to use DC to DC converter. Why waste energy & Money with AC inverter?
you can also use Car charger.
@@ZenInnovations ok, can you give link
Mere pass heliac 1200 he. Usme calibration me charging amp me grid ka he but spv ka nahi show kar raha he. Aesa kyo? To kya ye solar se charging nhi kar pata.
Its a Lower end model. PWM charger only. It won't have as many features as Gamma plus.
But isme solar se charging hota bhi he ya nahi
hona chahiye.
Agar apne heliac 1200 ka koi video banaya ho to plz send me link
@@JashuRam I do not have, as I don't have Heliac.
Very good so useful
Glad to hear that
utl gamma plus 12 volt 1 kva inverter के साथ 750 watt 24 volt poly solar panel set-up मे maximum कित्ना एम्पियर current आना चहिए ? uttam khadgi from nepal
ruclips.net/video/R69XP5_Bvhc/видео.html