RCC column design using etabs - SMRF design using ACI code

Поделиться
HTML-код
  • Опубликовано: 21 окт 2024

Комментарии • 49

  • @EngineeringLearningPlatform
    @EngineeringLearningPlatform  5 лет назад

    CORRECTION : TAKE SHEAR REINFORCEMENT Av FROM ETABS IN (in^2/in) UNITS FOR USING THE TIES SPACING FORMULA PROVIDED IN THE VIDEO.
    RCC column design using etabs - SMRF using ACI code - Special moment resiting frame design building frame system

  • @EngineerHassanTahir
    @EngineerHassanTahir 11 месяцев назад

    Man, You are just amazing

  • @structurefreek1713
    @structurefreek1713 5 лет назад +3

    Awesome work... Please make a video on design and detailing of the shear wall including assigning pier labels, boundary elements check, types of methods available in ETABS. When designing lift core please explain all walls in lift should be assigned the same pier labels or different. Please explain in that video.. Thank you bro

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  5 лет назад +3

      Yes before shear wall i had to go through many practice problems and code limitations and modeling techniques to provide authentic tutorial with code references and detaiking preferences so that understanding is easy with strong code supports .

    • @structurefreek1713
      @structurefreek1713 5 лет назад

      @@EngineeringLearningPlatform I appreciate your work brother... Keep going

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  5 лет назад

      @@structurefreek1713 please share with others too :)

    • @structurefreek1713
      @structurefreek1713 5 лет назад

      @@EngineeringLearningPlatform I share with my friends all the time.

  • @sharmarkeabdirahman7323
    @sharmarkeabdirahman7323 Год назад

    The tie legs you used to calculate spacing is 4 legs, but the detailing you used 6 legs,

  • @mushasm007
    @mushasm007 5 лет назад +2

    Dear highly appreciate ur effort.
    Pls correct the shear rebar size calculation. It Should have been rebar area required ( as evaluated by Etabs) divided by the product of no of rebar legs and bar spacing.

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  5 лет назад

      Yes the etabs output should have been in in2/in rest is okay . Just did the mistake in units

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  5 лет назад

      I have added correction in video's description

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  5 лет назад

      Just see the units
      Spacing (in) = [#Legs × Area ties (in^2) / [ Av by etabs (in^2/in) ]
      in^2 cancels in^2 leaving 1÷(1/in) OR simply "in" which is unit of spacing required .

    • @mushasm007
      @mushasm007 5 лет назад

      Still the formula for Av bar spacing should be inverse.
      It should be Av required ( from Etabs) divided by Av (proposed)

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  5 лет назад

      Spacing = Providing bars / Required bars

  • @mohammadasif-jg3wz
    @mohammadasif-jg3wz Год назад

    Sir I want to take classes to learn etabs completely which plate is best for it, and want to learn it with ACI codes

  • @sadiqgillpakistan7251
    @sadiqgillpakistan7251 5 лет назад +1

    Bro #5 Bar is too dificult to bend at site...WE usually use #3 stirrups

  • @civilengineeringplatform1368
    @civilengineeringplatform1368 5 лет назад +2

    much appreciated

  • @engrgep
    @engrgep Год назад

    Hi sir. I set column to be DESIGN after the analysis all column pass showing all Longitudinal rebar area but when i check the column by right clicking it, the rebar areas on each case and each part appears, the area appear is NOT THE MAXIMUM there are value higher than what appear. What u think is the problem? Any experience? Thanks and more powers.

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  Год назад

      Which Etabs version are you using

    • @engrgep
      @engrgep Год назад

      @@EngineeringLearningPlatform 2016

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  Год назад

      @@engrgep this seems to be a problem with your cracked version. It's not normal

    • @engrgep
      @engrgep Год назад

      @@EngineeringLearningPlatform thanks. I see some write up in the internet that for column DESIGN we need really to check one by one after the analysis and design to ensure all columns are safe.

  • @sadiqgillpakistan7251
    @sadiqgillpakistan7251 5 лет назад

    Bro why haven't you selected beams alongwith columns while selecting SMRF in design preferences? Moment resisting frame resists lateral loading by flexural actions of columns and beams....I think if you have selected only columns then software will design and detail columns for ductility only but beams should also be selected while assigning SMRF or IMRF....Please reply

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  5 лет назад

      Since the concern is to design column . And selecting beam for smrf will not change the beam's strength but will change steel in beam which is not our concern here

  • @sadiqgillpakistan7251
    @sadiqgillpakistan7251 5 лет назад

    Bro you haven't uploaded the video on shear wall design yet..How much time will it take?

  • @s-esmail
    @s-esmail 5 лет назад

    appreciate it.. but I want to ask there is no design for beam - column joint ( stirrups)??

    • @s-esmail
      @s-esmail 5 лет назад

      and want to ask about sum moment of resistance of column should be higher than the sum of beams by 1.2
      the moment of resistance of beams depend on the reinforcement for beams so it should be designed on etabs and not increase it any more??

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  5 лет назад +1

      @@s-esmail yes this check is know as strong column weak beam check which is already applied in this video at 26:00 . Yes the joint details should be done . Which is in other words stirrups and tie spacing at supports . That is what we calculate . However we may increase spacing of stirrups and ties in mid spans/Height respectively

    • @s-esmail
      @s-esmail 5 лет назад

      @@EngineeringLearningPlatform what I understand that the stirrups you calculate only at h/6 above and below the joint (h :height of the floor) as i think
      but what about the joint it self??

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  5 лет назад +1

      Yes the joint detailing will also follow this .

  • @markcanicula
    @markcanicula 4 года назад

    Hi bro. i have a question, you design the column in accordance to the SMRF requirements by ACI and you leave the beam design, is there a need also for a design of beam reinforcement and ties in accordance to SMRF req.? If yes, do you have video for it? Also in designing a residential house is it still required to design it using SMRF if the location in on zone 4? its a 3storey residential house. Please reply and thanks for the video!

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  4 года назад +1

      Yes there are special requirements of beams as well refer to chapter 21 of ACI 318 . Yes SMRF is used in zone 3 and 4 .

    • @markcanicula
      @markcanicula 4 года назад

      @@EngineeringLearningPlatform do you video for it bro? Meaning etabs will not provide us detailing of steel reinforcement in the software using SMRF? Thanks for the reply. Also on safe do i need to use meshing if i have strap foundation? As i know it can detail the foundation using strip method and will provide correct values for reinforcement and no need for special detailing like this on SMRF right?

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  4 года назад

      @@markcanicula Yes etabs doesn't, no its similar to IMRF beam on which i have made video already, you can see in etabs playlist, but the main difference is only of the numbers betweem smrf and imrf, else method is same, no auto mesh us more than enough in safe . No special seismic requirements . Just check pressure if foundation using SMRF service combos

    • @markcanicula
      @markcanicula 4 года назад

      @@EngineeringLearningPlatform yeah your correct there is no need for SMRF in foundation. Just soil pressure. Is punching shear a serviceablity requirements or strength? So i need to use slab mesh on SAFE or no need? Thanks!

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  4 года назад

      @@markcanicula Its a strength requirement .

  • @abbas2294
    @abbas2294 5 лет назад

    You said the nominal capacity of the beam x 1.2 should be less than column flexural strength. But here u r checking in Dcon10. Where is the nominal capacity without any factor?

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  5 лет назад +1

      The etaba option already checks that itself using space frame criterion and shows O/S if 1.2x of beams flexural capacity exceed columns flexural capacity at a joint

  • @farhaankhan5868
    @farhaankhan5868 5 лет назад +1

    Waiting 😄

  • @mdtariqulislam2795
    @mdtariqulislam2795 4 года назад

    great

  • @abbas2294
    @abbas2294 5 лет назад

    can u provide a link for these smrf detailing requirements?